S5751460078Industrial RTLS

Honeywell International Inc.
Industrial RTLS - FCC ID S5751460078 - Honeywell International Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 28, 2022
Application Purpose
Original Equipment
Date of Application
Apr 25, 2022
Equipment Note
Industrial RTLS
Frequency Range
2405.00000000 - 2480.00000000
Company
Honeywell International Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

IndustrialRTLS Release100.1 IndustrialRTLSTagUsersGuide EPDOC-X744-en-100A April2022 Disclaimer ThisdocumentcontainsHoneywellproprietaryinformation. Informationcontainedhereinistobeusedsolelyforthe purposesubmitted,andnopartofthisdocumentorits contentsshallbereproduced,published,ordisclosedtoa thirdpartywithouttheexpresspermissionofHoneywell InternationalSàrl. Whilethisinformationispresentedingoodfaithandbelieved tobeaccurate,Honeywelldisclaimstheimpliedwarrantiesof merchantabilityandfitnessforapurposeandmakesno expresswarrantiesexceptasmaybestatedinitswritten agreementwithandforitscustomer. InnoeventisHoneywellliabletoanyoneforanydirect, special,orconsequentialdamages.Theinformationand specificationsinthisdocumentaresubjecttochangewithout notice. Copyright2022-HoneywellInternationalSàrl 2 3 Contents Aboutthisguide6 Revisionhistory6 Intendedaudience6 Prerequisiteskills6 Howtousethisguide6 RequiredHoneywelldocum entation7 Acronym s7 IndustrialRTLSTagoverview8 RTLSTagO verview8 Overview8 Environm entalspecification9 Hardwarecom ponent10 Dim ensions10 Physicaldescription11 ExternalviewofpersonnelRTLSTag11 Com ponentdescriptionofpersonnelRTLSTag13 IDcard13 Configurationbutton13 Protectivefilter13 LEDindicator14 Alligatorclip14 SOSbutton14 Colorcodingandbarcodelabel14 RTLSTagconfiguration16 Prerequisites16 EstablishtheconnectionbetweenW DM andRTLSTag16 Initialsetupconfiguration:16 DescriptionoftheRTLSTagparam eters:18 M ounting27 PersonnelRTLSTagm ountingconsideration27 PersonnelRTLSTagMount27 AssetTagm ountingconsideration28 O peration29 PersonnelRTLSTagoperation29 PersonnelRTLSTagstatusandnotifications29 PersonnelRTLSTagsafetyalert30 M aintenance32 Inspection32 ProtectiveFilter32 Crack33 Batteryreplacem ent33 Removal33 lnstallation35 Storage38 Storagerack38 SafetyandSecurityinform ation39 SecurityChecklist39 UsersRolesforRTLS40 ReportsecurityVulnerability41 Howtoreportasecurityvulnerability41 Third-partylicenses41 Productcertifications42 RED(RadioEquipm entDirective)42 FCC(FederalCom m unicationCom m ission)42 IndustryCanada(IC)43 4 5 Déclarationsdeconformité43 RTLS-TagRadio44 W irelesscertification45 HazlocCertification46 LabelDrawing47 AppendixA48 6 CHAPTER 1 ABO UTTHISG UIDE Thisguidedescribestheprocedurestoconfigure,mount, operate,andmaintenanceoftheIndustrialRTLS(Real-Time LocationSolution)Tag.IndustrialRTLSTagisoneofthe componentsintheIndustrialRTLSforindustrialcontroland operationsacrosshazardousandsafeareas. Revisionhistory RevisionDateDescription AApril2022Initialreleaseofthedocument Intendedaudience Thisguideisintendedforpeoplewhoareresponsiblefor planning,administering,andoperatingtheIndustrialRTLS Tag.ThesepeopleincludePlantManagers,Process Engineers,andSystemAdministrators. Prerequisiteskills Itisassumedthatyouarefamiliarwiththeoperationof IndustrialRTLSTag.OneWirelesssystemsoftwareandthe plantprocesseswhichOneWirelesssystemcontrols, MicrosoftWindowsoperatingsystemsandnetwork administrationtasks. Howtousethisguide Thisguideprovidesguidanceon: nRTLSTagdescription nRTLSTagconfiguration nRTLSTagmounting nRTLSTagoperation nRTLSTagmaintenance 6 RequiredHoneywelldocum entation Thefollowingguidesandsourcescontainadditional informationrequiredfordeployingIndustrialRTLSTag.Itis recommendedtohavetheseguidesreadilyavailablefor reference. nIndustrialRTLSUsersGuide nOneWirelessWDMUsersGuide nOneWirelessFDAPUsersGuide nOneWirelessPCAPUsersGuide Acronym s Thefollowingaretheacronymsused: AcronymsExpansion IDIdentity RTLSReal-TimeLocationSolution WDMWirelessDeviceManager FDAPFieldDeviceAccessPoint PCAPProcessControlAccessPoint PPEPersonalProtectiveEquipment P/NPartNumber MMMillimeter LEDLight-EmittingDiode ISAIntelligentServiceArchitecture REDRadioEquipmentDirective FCCFederalCommunicationCommission ICIndustryCanada DSSSDirect-sequencespreadspectrum HAZLOCHazardousLocation 7 Aboutthisguide CHAPTER 2 INDUSTRIALRTLSTAG O VERVIEW RTLSTagO verview ThefollowingaretheoverviewandfeaturesofRTLSTag: O verview RTLSTagisapersonnelwearableIndustrialwirelessTag operatingat2.4GHzISMband.Itisacompact,light,and simplebattery-operateddevicethatwillbewearablehandily usingaclipaccessoryoralanyard.TheRTLSTag communicateswithFDAP32AnchorstoenableReal-time locationtracking.ItisanIntrinsicallysafeclass1/div1certified devicewithabatterylifelastingupto3years*.TheRTLSTag hasanIP65ratingandtheabilitytooperateinharsh environments.TheRTLSTagcanalsobemountedandused forassettracking. *-Dependsupontheoperatingconditions. 8 CHAPTER 3 ENVIRO NM ENTAL SPECIFICATIO N ThefollowingaretheEnvironmentalspecification: SpecificationDetails EnvironmentalRatingsIP65 OperatingTemperature-20to+60°C(IECEx,ATEX,CSA) OperatingHumidity0~95%non-condensing TransportationandStorage Humidity 0~95%non-condensing MechanicalShock5GOperational,15GNon- Operational 9 CHAPTER 4 HARDW ARECO M PO NENT ThefollowingaretheHardwarecomponentsoftheRTLS Tag: nTag nBattery nClip Dim ensions ThefollowingfigureandtablegivethedetailsoftheRTLS Tagdimensions: Specification Details Dimensions92mmheightx63.8mmlengthx21.0mmwidth. 10 Specification Details Weight100grams. DistanceDistancefromAntennatoEnclosure9.07mm. Separation Distance Separationdistancebetweentheuserandthe antennaoftheTagdeviceis20.93mm. Physicaldescription Thefollowingarethephysicaldescriptionofthepersonnel RTLSTag: ExternalviewofpersonnelRTLSTag ThefollowingaretheexternalviewsofthepersonnelRTLS Tag: FrontView RearView 11 Hardwarecomponent 12 Hardwarecomponent Com ponentdescriptionofpersonnel RTLSTag Thefollowingarethecomponentdescriptionofthepersonnel RTLSTag: IDcard RTLSTagismadeofplastic,withprovisiontoholdastandard IDcardinthefront. Configurationbutton Aconcealedconfigurationbuttonneedstobeoperatedwitha toolfortheinitialsetupconfigurationoftheTag. Protectivefilter Ablackprotectivefilterisusedforpressuresensing.Nextto theconfigurationbuttonthereisaventstamp. 13 Hardwarecomponent 14 LEDindicator TheLEDindicatoronthetoplightsupwhentheconfiguration andSOSbuttonsareoperatedgivingsecondaryfeedbackto theuser…

Text truncated - open the document above for the full version.

Cover Letter(s)

Date: 13-01-2022 Federal Communications Commission Authorization and Evaluation division Subject: Confidentiality Request for Field Device Access Point Gen3 FCC ID: S5751460078 Pursuant to 47 CRF 0.457(d) and 0.459, Honeywell Internal Inc. Industrial Measurement & Control requests that a part of the subject application be held confidential Type of Confidentiality requested Exhibit Type File name Long Term Operational Description Operational Description Tag Long Term Block Diagram Block Diagram RTSL Tag Long Term Bill of Material Bill of Material RTLS Tag Long Term Schematic Schematics RTLS Tag Short Term User Manual User Manual RTLS tag Short-term Internal Photos Internal Photos The above materials contain proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. Short term confidentiality period is 180days. Hand signed (not electronic) Prasad Samudrala Company Honeywell International Inc Address: 1860, W. Rose garden Lane, Phoenix, Arizona, US-85027 Phone: 917348936728

External Photos

Produkte Products www.tuv.com EUT External Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 1 von 4 Page 1 of 4 EUT External Photos Figure 1: Front view of the EUT Figure 2: Rear view of the EUT Produkte Products www.tuv.com EUT External Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 2 von 4 Page 2 of 4 Figure 3: Dimensional view of EUT Figure 4: Dimensional view of EUT Produkte Products www.tuv.com EUT External Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 3 von 4 Page 3 of 4 Figure 5: Right Side view of the EUT Figure 6: Left side view of the EUT Produkte Products www.tuv.com EUT External Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 4 von 4 Page 4 of 4 Figure 7: Top view of the EUT Figure 8: Bottom view of the EUT ****End of EUT External Photos****

Internal Photos

Produkte Products www.tuv.com EUT Internal Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 1 von 3 Page 1 of 3 EUT Internal Photos Figure 1: EUT with enclosure Figure 2: PCB o EUT with enclosure Produkte Products www.tuv.com EUT Internal Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 2 von 3 Page 2 of 3 Figure 3: Front view of the PCB Figure 4: Rear view of the PCB Produkte Products www.tuv.com EUT Internal Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 3 von 3 Page 3 of 3 Figure 5: Front view of the PCB with 3.6V Battery Figure 6: Rear view of the PCB with 3.6V Battery ****End of EUT Internal Photos****

RF Exposure Info

Produkte Products www.tuv.com RF Exposure Reference Test Report No: ULR- ULR-TC568822300000016F Seite 1 von 3 Page 1 of 3 RF Exposure Report Following FCC KDB 447498 D01 General SAR test exclusion guidelines The corresponding SAR exclusion threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation Distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g. Extremity SAR, where  f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation.  The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion(447498 D01 General RF Exposure Guidance v06) 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold Is determined according to the following  [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100 MHz to 1500 MHz  [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion,  The power threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm  The power threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test separation distances ≤ 50 mm  SAR measurement procedures are not established below 100 MHz When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be acceptable. Produkte Products www.tuv.com RF Exposure Reference Test Report No: ULR- ULR-TC568822300000016F Seite 2 von 3 Page 2 of 3 SAR Test Exclusion Thresholds Maximum Measured Transmitter Power: Exclusion calculation considering conducted power Antenna 1: Frequency (GHz) Max.Power (dBm) Tune- up value Max.Power Including Tune-up Tolarence (dBm) Max.Power Including Tune-up Tolarence (mW) Minimum test separation distance (mm) SAR Test Exclusion Calculation Values 1-g Extremity SAR Test exclusion Threshold 2.405 8.50 1 9.50 8.91 20.93 0.659964829 3 2.440 8.39 1 9.39 8.68 20.93 0.647590077 3 2.475 7.83 1 8.83 7.63 20.93 0.573320785 3 Exclusion calculation considering radiated E I R P Frequen cy (GHz) Max.Power (dBm) Tune- up value Antenn a gain (dBi) Max.Power Including Tune-up Tolarence & antenna gain (dBm) Max.Power Including Tune-up Tolarence & antenna gain (mW) Minimu m test separati on distance (mm) SAR Test Exclusion Calculation Values 1-g Extremity SAR Test exclusion Threshold 2.405 8.50 1 0.5 10.00 10.00 20.93 0.740701267 3 2.440 8.39 1 0.5 9.89 9.74 20.93 0.726673658 3 2.475 7.83 1 0.5 9.33 8.57 20.93 0.643952703 3 Antenna 2: Frequency (GHz) Max.Power (dBm) Tune- up value Max.Power Including Tune-up Tolarence (dBm) Max.Power Including Tune-up Tolarence (mW) Minimum test separation distance (mm) SAR Test Exclusion Calculation Values 1-g Extremity SAR Test exclusion Threshold 2.405 8.49 1 9.49 8.89 20.93 0.658483426 3 2.440 8.37 1 9.37 8.64 20.93 0.644605791 3 2.475 7.85 1 8.85 7.67 20.93 0.576326398 3 Exclusion calculation considering radiated E I R P Frequen cy (GHz) Max.Power (dBm) Tune- up value Antenn a gain (dBi) Max.Power Including Tune-up Tolarence & antenna gain (dBm) Max.Power Including Tune-up Tolarence & antenna gain (mW) Minimu m test separati on distance (mm) SAR Test Exclusion Calculation Values 1-g Extremity SAR Test exclusion Threshold 2.405 8.49 1 0.5 9.99 9.97 20.93 0.738479163 3 2.440 8.37 1 0.5 9.87 9.70 20.93 0.723689372 3 2.475 7.85 1 0.5 9.35 8.60 20.93 0.646206913 3 Produkte Products www.tuv.com RF Exposure Reference Test Report No: ULR- ULR-TC568822300000016F Seite 3 von 3 Page 3 of 3 From above table calculation the EUT is exempted from routine SAR evaluation Note: 1. SAR exclusion threshold is calculated using condition1 formulas. 2. Conducted power is taken from the RF test report ULR-TC568822300000016F 3. Antenna gian values are taken from Antenna data sheet. IC limit As per RSS102 Section 2.5.1 SAR evaluation is required if the separation distance between the user and/or bystander and the antenna and/or radiating element of the device is less than or equal to 20 cm, except when the device operates at or below the applicable output power level (adjusted for tune-up tolerance) for the specified separation distance defined in Below Table. Note: Max. e.i.r.p. is 10mW which is less than exemption limits 30mW for 20mm distance. ****END OF TEST REPORT*****

Test Report

Prüfbericht – Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: ULR-TC568822300000016F Auftrags-Nr.: Order no.: 146621230 010 Seite 1 von 71 Page 1 of 71 Kunden-Referenz-Nr.: Client reference no.: 2024735 Auftragsdatum: Order date: 2021-10-11 Auftraggeber: Client: 1. HONEYWELL INTERNATIONAL INC 1860W, ROSE GARDEN LANE, AZ75,M-16-7988, PHOENIX, ARIZON, UNITED STATES 2. Honeywell LTD 500 Brooksbank Avenue, North Vancouver, BC, V7J 3S4; Canada Prüfgegenstand: Test item: Industrial RTLS Bezeichnung Identification OW-RTLTG2 Serien -Nr.: Serial no.: 14W23C12345678912 Auftrags-Inhalt: Order content: Testing and issue of Test Report and Grant Certificate Prüfgrundlage: Test specification: FCC Part 15 Subpart C 15.247,15.205 & 15.209 RSS 247 Issue 2,RSS Gen Issue 5 Wareneingangsdatum: Date of sample receipt: 2021-12-16 Prüfmuster-Nr.: Test sample no: A003238199-001 Prüfzeitraum: Testing period: 2021-12-16 - 2021-12-30 Ort der Prüfung: Place of testing: Wireless laboratory, Bangalore Prüflaboratorium: Testing laboratory: TÜV Rheinland (India) Pvt. Ltd. 27/B,2nd cross road, Electronic city Phase1, Banglore-560100, India FCC Test Site Registration No: 496599 IC Test Site Registration Number: 3665-1 Prüfergebnis*: Test result*: Pass geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2021-12-16 Ausstellatum: Issue date: 2022-04-06 Stellung / Position: Yogesh V Engineer Stellung / Position: Lokesh Ramu Manager Sonstiges / Other: FCC ID: S5751460078 IC: 573W-51460078 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (India) Pvt. Ltd, Plot No.27/B, 2nd Cross, Electronic city, Industrial Area, Phase I, Hosur Road Bangalore-560 100, India Mail: [email protected] ∙ Web: www.ind.tuv.com Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: ULR-TC568822300000016F Seite 2 von 71 Page 2 of 71 TEST SUMMARY Test Item Applicable Standard Result FCC ISED Maximum conducted (average) output power FCC 15.247 (b)(3) RSS 247 Issue 2, Section 5.4 (d) Pass Maximum Power Spectral Density FCC 15.247(e) RSS 247 Issue 2, Section 5.2 (b) Pass DTS Bandwidth FCC 15.247(a)(2) RSS 247 Issue 2, Section 5.2 (a) Pass Emissions in non-restricted frequency bands FCC 15.247(d) RSS 247 Issue 2, Section 5.5 Pass Spurious Radiated Emissions and Restricted Bands of Operation FCC 15.209 / FCC 15.205 RSS-Gen Issue 5, Section 8.9 /8.10 Pass Product Category: Electronics Testing Test Discipline: EMC Test Facility Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: ULR-TC568822300000016F Seite 3 von 71 Page 3 of 71 REVISION HISTORY OF THIS REPORT Report Number Version Description Issue date ULR- TC568822300000016F 01 Initial issue of report 2022-04-06 Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: ULR-TC568822300000016F Seite 4 von 71 Page 4 of 71 Table of Contents 1 GENERAL REMARKS ........................................................................................................................................... 5 1.1 Attachments .................................................................................................................................................. 5 2 TEST SITES .......................................................................................................................................................... 6 2.1 Testing Facilities............................................................................................................................................ 6 2.2 List of Test and Measurement Instruments ................................................................................................... 6 3 GENERAL PRODUCT INFORMATION ................................................................................................................. 7 3.1 Product Function and Intended Use.............................................................................................................. 7 3.2 Ratings and System Details of Equipment under Test ................................................................................. 7 3.3 Measurement Uncertainty: ............................................................................................................................ 8 4 TEST SET-UP AND OPERATION MODE ............................................................................................................. 9 4.1 Principle of Configuration Selection .............................................................................................................. 9 4.2 Test Operation and Test Software ................................................................................................................ 9 4.3 Special Accessories and Auxiliary Equipment .............................................................................................. 9 4.4 Simultaneous Transmission .......................................................................................................................... 9 4.5 Countermeasures to achieve EMC Compliance ............…

Text truncated - open the document above for the full version.

Test Setup Photos

Produkte Products www.tuv.com Test Setup Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 1 von 6 Page 1 of 6 Frequency range: 9kHz-30MHz Polarization: Parallel Frequency range: 9kHz-30MHz Polarization: Perpendicular Produkte Products www.tuv.com Test Setup Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 2 von 6 Page 2 of 6 Frequency range: 30MHz-200MHz Polarization: Vertical Frequency range: 30MHz-200MHz Polarization: Horizontal Produkte Products www.tuv.com Test Setup Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 3 von 6 Page 3 of 6 Frequency range: 200MHz-1GHz Polarization: Vertical Frequency range: 200MHz-1GHz Polarization: Horizontal Produkte Products www.tuv.com Test Setup Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 4 von 6 Page 4 of 6 Frequency range: 1GHz-18GHz Polarization: Vertical Frequency range: 1GHz-18GHz Polarization: Horizontal Produkte Products www.tuv.com Test Setup Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 5 von 6 Page 5 of 6 Frequency range: 18GHz-40GHz Polarization: Vertical Frequency range: 18GHz-40GHz Polarization: Horizontal Produkte Products www.tuv.com Test Setup Photos Reference Test Report No: ULR- TC568822300000016F & 17F Seite 6 von 6 Page 6 of 6 Radiated Closeup Photo Conducted Test Setup ****End of Test Setup Photos****

Contact Information

Applicant

Richard Allen(Regulatory Compliance)
[email protected]215-641-3189Fax: 215-641-4447

Technical Contact

HONEYWELL TECHNOLOGY SOLUTIONSPRASAD SAMUDRALA
[email protected]+918026588360

DEVARABISANAHALLI VILLAGE · BANGALORE · India

Test Firm

TUV Rheinland (India) Pvt. Ltd.B R Guruprasad
[email protected]+91 8046498000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz7.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. This device contains a 2.4GHz Proprietary transmitter.

Other Applications from Honeywell International Inc.

Honeywell Versatilis Transmitter - FCC ID S5751490045 - Honeywell International Inc.
S5751490045

Honeywell Versatilis Transmitter

Feb 14, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Field Device Access Point Gen3 Anchor, Field Device Access Point Gen3 Plus Anchor - FCC ID S5751308987 - Honeywell International Inc.
S5751308987

Field Device Access Point Gen3 Anchor, Field Device Access Point Gen3 Plus Anchor

Jun 22, 2022

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Field device access point Gen3 - FCC ID S5751307990 - Honeywell International Inc.
S5751307990

Field device access point Gen3

Mar 15, 2021

Equipment Class

DTS - Digital Transmission System
LOW COST ISA 100 RADIO MODULE(51306799-001) - FCC ID S5751306799 - Honeywell International Inc.
S5751306799

LOW COST ISA 100 RADIO MODULE(51306799-001)

Jun 27, 2011

Equipment Class

DTS - Digital Transmission System
51306533 - FCC ID S57-51306533 - Honeywell International Inc.
S57-51306533

51306533

Jan 27, 2011

Equipment Class

DTS - Digital Transmission System