Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MANGA Point User’s Manual (Last updated: 2004-06-14) Copyright Notice Copyright  2004 by PePLink Ltd. Address: 4606-10, 46/F., China Resources Building, 26 Harbour Road, Wanchai, Hong Kong This document contains proprietary and confidential information of PePLink Ltd. The contents of this document may not be disclosed to third parties. Copies and duplicated in any form, in whole or in part, without prior written permission of PePLink Ltd is forbidden. This publication is subject to change without notice. The MANGA Point name and logo are registered trademarks of PePLink Ltd. FCC NOTICE INFORMATION FOR THE USER This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1) Reorient or relocate the receiving antenna. 2) Increase the separation between the equipment and receiver. 3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4) Consult the dealer or an experienced radio/TV technician for help. The user may find the following publication prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems" (Stock Number 004-000-00345-4). Available exclusively from the Superintendent of Documents, Government Printing Office, Washington, DC 20402 (telephone 202-512-1800). FCC WARNING 1. FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. 2. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 3. Changes or modifications not expressly approved by the party responsible for compliance to Part 15 of the FCC Rules could void the user's authority to operate the equipment. CAUTION (1) Connections between peripherals of this equipment may be made with low voltage non-shielded computer data cables. (2) Network connections may consist of non-shielded CAT 5 cable. (3) Use only PepLink approved wall adapter to supply 9 VDC to system. (4) Indoor use only. CONTENTS 1 INTRODUCTION..........................................................................................1 1.1 What is MANGA Point?..............................................................................................1 2 INSTALLATION............................................................................................2 2.1 Connecting Your Computer and Your MANGA Point........................................2 2.2 Turning on Your MANGA Point................................................................................2 2.3 Login to MANGA Point...............................................................................................3 3 CONFIGURATION........................................................................................5 3.1 Connect..........................................................................................................................5 3.2 CPE Setup.....................................................................................................................6 3.3 Port Forward.................................................................................................................9 3.4 Incoming Traffic Filter..............................................................................................10 3.5 Outgoing Traffic Filter..............................................................................................11 3.6 Specification...............................................................................................................12 4 TROUBLESHOOTING...............................................................................13 INTRODUCTION 1 1 INTRODUCTION 1.1 What is MANGA Point? MANGA Point is a network device for one or more PCs on a LAN to simultaneously access secure wireless broadband Internet service. With integrated 4 Ethernet switching ports and user-friendly web-based network administration features, MANGA Point can connect 4 PCs to the Internet without installing any wireless LAN adapter or configuring tedious wireless network settings on the PCs. MANGA Point supports DHCP, NAT, DMZ and port forwarding functions. It can also be configured to filter incoming and outgoing traffic. So users could get online by just having to connect the PC and the MANGA Point with an Ethernet cable. INSTALLATION 2 2 INSTALLATION 2.1 Connecting Your Computer and Your MANGA Point For the initial configuration of your MANGA Point, connect your local computer LAN port to MANGA Point LAN port using straight-through Ethernet or crossover Ethernet cables. 2.2 Turning on Your MANGA Point After you’ve made the connections, connect the power cable to a power supply and look at the front panel LED. The LAN LED turns on if it is properly connected. INSTALLATION 3 2.3 Login to MANGA Point 1. Make sure your MANGA Point hardware is properly connected (refer to instructions in the hardware installation chapter 2.1). 2. Launch your web browser. You should be redirected to MANGA Point web administration page. If you are not being redirected to web administration page, enter “192.168.1.1” as the web…
Text truncated - open the document above for the full version.
Y1 25 MHz Multi-Port Ga teway WAN and LAN Input Power Y2 25 MHz Y3 25 MHz WLANWAN WAN USB JT AG/ICE UAR T MCU Flash SDRAM Status Led Ethernet IEEE 802.3 1 1 MTL2015 Block Dia gram Q540501.01.GEN A LJP LJP LAB LAB 08Sep04 08Sep04 08Sep04 08Sep04
1 Subject:FW: PePLink Ltd., FCC ID: SAN5405X, Assessment NO.: AN04T4084, Notice#1 Importance:High Hi, Mike Kuo, Thank you for the comments and questions. We have provided all answers with the attachments in PDF: 1.0 Q540502We.02.DWG.pdf Revamped RF report with photos, descriptions, and calibration dates. 2.0 FCC MTL2015sch2.0_A.pdf Schematics with block diagram incorporating Y1, Y2, and Y3 clocks. Deleted future wishful thinking of engineers on project and merely showed the system shipped today. 3.0 MANGA Point User Manual FCC. Pdf Operator's Manual for device (unchanged) 4.0 SPLI25We.GEN.pdf Definition of acceptable Electronic Signature and Pulver Laboratories Inc. Policy to protect employees and associates from ID theft and yet continue to sign electronic documents. Answers to your questions shown in e-mail below. This project is super hot for the client; please, please expedite. Lee -----Original Message----- From: Compliance Certification Services [mailto:[email protected]] Sent: Friday, July 30, 2004 9:50 PM To: [email protected] Subject: PePLink Ltd., FCC ID: SAN5405X, Assessment NO.: AN04T4084, Notice#1 Question #1: No conducted emission test setup photo found. Please provide. [Reply from Lee Pulver 18 Aug 2004] In Q540502We.02.DWG.pdf, see Figure 4, page 24 of 50. New conducted data and new graphs begin on page 45 of 50. Question#2: EUT is powered from an external AC adapter per test report/user manual stated, please provide this adapter¡¦s internal and external photos. [Reply from Lee Pulver 18 Aug 2004] In Q540502We.02.DWG.pdf, see photographs of wall adapter power supply, internal and external, Figures 11, 12, 13, and 14 on pages 31, 32, 33, and 34. Also not description on pages 31 and 40. Question#3 : Per ANSI C64.3 section 10.1.4, all test equipment used shall be 2 included with the test report with the date of last calibration and calibration interval. Please provide. [Reply from Lee Pulver 18 Aug 2004] In Q540502We.02.DWG.pdf please note that we have revamped the Laboratory Test Equipment table, on pages 14 and 15 of 50 per your request. This report continues to contain paragraph 1.5 on page 13 of 50 which states: “Equipment used during measurements calibrated according to internationally acceptable laboratory procedures. Calibration data along with Certificates of conformance and traceability are on file at the testing facility. Each calibrated equipment item is individually labeled with date calibrated; due date for next calibration; initials of person who calibrated the equipment; and the name of the organization that performed the calibration service.” Question#4 : Block diagram should include the clock oscillators¡¦ rate if available. Based on the information of test report, EUT has a 25MHz oscillator on. So please revise the block diagram to include it. [Reply from Lee Pulver 18 Aug 2004] FCC MTL2015sch2.0_A.pdf presents revised block diagram with associated schematics. (Question#5 : Based on the user manual, this device has incorporated a 802.11b/g WLAN card inside, yet according to the block diagram, this device may have possible to incorporate a Bluetooth module. Please explain.) [Reply from Lee Pulver 18 Aug 2004] FCC MTL2015sch2.0_A.pdf revised block diagram eliminates this option. No Bluetooth option available on this product. Best Regards, Mike Kuo The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 30 days of the original e-mail date may result in application dismissal and forfeiture of the filing fee. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e-mail address listed below the name of the sender. Submitted 16Aug04.zip
PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 24 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 1: PLI Photograph Number 5405C2734SJ-04 illustrates the front view of the EUT. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 25 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 2: PLI Photograph Number 5405C2734SJ-05 illustrates the rear view of the EUT. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 31 of 50 DRAWING: Q540502W.02.DWG.doc Issued: 17 Jul 2004 Re-Issued: 11 Aug 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 11: PLI Photograph Number 5405C2734LG-21 illustrates the top cover with label surface and 9.0 VDC output connector of the wall adapter power supply, which provides power for the EUT. Product :External Power Supply for EUT (100-240 VAC input; 9 VDC output) Model Number :NSA-0181S09US2 Serial Number :PLI 5405C2734-03 FCC ID Number :None Manufacturer :NAZ Technology, Co., Ltd.Emachines PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 32 of 50 DRAWING: Q540502W.02.DWG.doc Issued: 17 Jul 2004 Re-Issued: 11 Aug 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 12: PLI Photograph Number 5405C2734LG-23 illustrates the input power side of the wall adapter power supply, which provides power for the EUT.
PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 20 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver 2.0 Mandatory Labeling and Operators' Manual Information and Shipping Documents 2.1 Label The illustration on the next page shows the actual FCC label with the appropriate wording. Note the letters "EMI" on the label, which abbreviate "Electromagnetic Interference". Organizations like the Federal Communications Commission and their respective limits are listed on the label. Also notice the letters "NRTL", which abbreviate "Nationally Recognized Testing Laboratory" as recommended by OSHA and the National Electrical Code for the United States. For Pulver Laboratories product Certification labels used for safety Certification, the phrase "SAFETY" appears on the label. Safety Certifying organizations like Pulver Laboratories are listed on the label adjacent to the testing standards used during equipment evaluation. A rough sketch of the label location is shown below. Bottom Panel of EUT Label PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 21 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver Label Illustration (RFI Controls Company part number S540501.01) OR Alternative label PePLink Ltd. FCC ID: SAN5405X This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Contains an approved RF module FCC ID: Q72WLG This Product Certified to meet the Standards in the categories listed on this label by Pulver Laboratories Inc. Control Number 5405X NRTL Information Technology Equipment EMI: 47 CFR Parts 1, 2, and 15 for FCC Class B
PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 28 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 5: PLI Photograph Number 5405C2734SJ-06 illustrates the top view of the EUT with the top cover removed. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 29 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 6: PLI Photograph Number 5405C2734SJ-07 illustrates the top and bottom chassis with the main board removed. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 30 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 7: PLI Photograph Number 5405C2734SJ-08 illustrates the component side of the motherboard printed circuit assembly, MANGA v2.0. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 31 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 8: PLI Photograph Number 5405C2734LG-06 illustrates the information label removed from the transceiver printed circuit assembly installed on component side of the motherboard printed circuit assembly, MANGA v2.0. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 32 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 9: PLI Photograph Number 5405C2734LG-07 illustrates the circuit side of the transceiver printed circuit assembly uninstalled from the motherboard printed circuit assembly, MANGA v2.0. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 33 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 10: PLI Photograph Number 5405C2734SJ-08 illustrates the component side of the motherboard printed circuit assembly, MANGA v2.0 directly under the transceiver printed circuit assembly after removing the transceiver. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 33 of 50 DRAWING: Q540502W.02.DWG.doc Issued: 17 Jul 2004 Re-Issued: 11 Aug 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 13: PLI Photograph Number 5405C2734LG-25 shows the top cover removed, exposing the circuit side of the Printed Circuit Assembly for the Wall adapter power supply assembly. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 34 of 50 DRAWING: Q540502W.02.DWG.doc Issued: 17 Jul 2004 Re-Issued: 11 Aug 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 14: PLI Photograph Number 5405C2734LGLG-26 shows the EUT wall adapter with the enclosure removed from the printed circuit board. This view emphasizes the components on the Neutral side of the Printed Circuit Assembly. The Line and Neutral connections routed individually from the Printed Circuit Assembly to the contacts on the chassis.
PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 1 of 50 DRAWING: Q540502W.02.DWG.doc Issued: 17 Jul 2004 Re-Issued: 11 Aug 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver This drawing consists of pages issued or re-issued on dates shown in the following list. Italic underlined words indicate content changes or additions on revised pages. PAGE ISSUED 1 - 48 17 Jul 2004 PAGE REISSUED 1 - 50 11 Aug 2004 COMPANY CONFIDENTIAL This report is the property of Pulver Laboratories Inc. The information contained in this report can only be divulged to persons authorized by Pulver Laboratories Inc. Portions of this report contain information proprietary to MetroFi Inc.; other portions of this report contain information proprietary to Pulver Laboratories and the RFI Controls Company. Except for agencies like the Federal Communications Commission, companies must sign Non-Use and Non-Disclosure Agreements before authorized to read this report. All rights reserved. No part of this report may be reproduced or transmitted in any form or by any means without permission in writing from Pulver Laboratories Inc. Copyright 1983 - 2004 Pulver Laboratories Inc. PLI223F11W.FRMx70 Q540502W.DWG PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 2 of 50 DRAWING: Q540502W.02.DWG.doc Issued: 17 Jul 2004 Re-Issued: 11 Aug 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver Disclaimer Statement THIS REPORT IS PROVIDED "AS IS" WITH NO WARRANTIES WHATSOEVER, INCLUDING ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY WARRANTY OTHERWISE ARISING OUT OF ANY PROPOSAL, SPECIFICATION OR SAMPLE. “COMPANIES” shall refer to Pulver Laboratories Inc. and RFI Controls Company. Information in this document may be provided in connection with Pulver Laboratories Inc. and RFI Controls Company products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by the sale of COMPANIES’ products. Except as provided in COMPANIES’ Terms and Conditions of Sale for such products, the COMPANIES assume no liability whatsoever and the COMPANIES disclaim any express or implied warranty, relating to sale and/or use of COMPANIES’ products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. COMPANIES’ products are not intended for use in medical, life saving, or life sustaining applications. COMPANIES retain the right to make changes to their test procedures and design specifications at any time, without notice. The Applicant designated in this report remains solely responsible for the design, sale, and functionality of its product, including any liability arising from product design, product infringement, or product warranty. Trademarks All trademarks and registered trademarks mentioned in this Pulver Laboratories Inc. Product Evaluation Report belong to their respective holders. Other product and corporate names may be trademarks of other companies and are used only for explanation and to the owners' benefit, without intent to infringe. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 3 of 50 DRAWING: Q540502W.02.DWG.doc Issued: 17 Jul 2004 Re-Issued: 11 Aug 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver TABLE OF CONTENTS Page Section Description 1 0.0 Drawing; Client; Product; Standards 7 1.0 Engineering Considerations 1.1 General Engineering Considerations 1.1.1 23 April 2004 FCC Conformance Statement 8 1.2 Specific Engineering Considerations 1.3 Product Description and Intended Use 11 1.4 Abbreviated List of Photographs 12 1.5 Equipment Used During Measurements 17 2.0 Mandatory Labeling, Manual Information, and Shipping Documents 2.1 FCC Label 18 Label Illustration 19 2.2 Operators’ Manual Information 19 2.3 FCC User Information 20 2.4 Industry Canada 21 Photographs 36 Oscillator Frequencies 37 EUT Orientation 38 3.0 Radiated Electromagnetic Interference - Test Configuration 41 4.0 Radiated EMI – Results 45 5.0 Conducted EMI -Test Configuration 45 6.0 Conducted EMI - Results 49 FCC Conducted Graphs 50 Last Page of Report Certificate of Conformance PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 4 of 50 DRAWING: Q540502W.02.DWG.doc Issued: 17 Jul 2004 Re-Issued: 11 Aug 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver Pulver Laboratories Inc. (PLI) File Number: 5405 Pulver Laboratories Inc. (PLI) Project Number: C2734 Product Names: (1) Indoor Wireless Broadband Internet Access Gateway (EUT) (EUT = Equipment Under Test) Model Numbers: (1) MANGA Point Serial Numbers: (1) None Pulver Laboratories Sample ID: (1) 5405C2734-01 Applicant: PePLink Ltd. 4606-10, 46/F., China Resources Building 26 Harbour Road, Wanchai Hong Kong Telephone: +852-2990-7657 Facsimile: +852-2304-2280 Contact: Michael Chan E-mail: [email protected] Location Certified: PePLink Ltd. 4606-10, 46/F., China Resources Building 26 Harbour Road, Wanchai Hong Kong Telephone: +852-2990-7657 Facsimile: +852-2304-2280 Contact: Michael Chan E-mail: [email protected] Manufacturing Location: PePLink Ltd. 4606-10, 46/F., China Resources Building 26 Harbour Road, Wanchai Hong Kong Telephone: +852-2990-7657 Facsimile: +852-2304-2280 Contact…
Text truncated - open the document above for the full version.
PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 26 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 3: PLI Photograph Number 5405C2734SJ-01 illustrates the front view of the Equipment Under Test in Radiated Electromagnetic Interference Test Configuration #1. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 27 of 48 DRAWING: Q540502W.DWG Issued: 17 Jul 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 4: PLI Photograph Number 5405C2734SJ-03 the rear view of the Equipment Under Test in Conducted Electromagnetic Interference Test Configuration #1. PULVER LABORATORIES INC. ELECTROMAGNETIC SHIELDS Celebrating 25 th year www.PulverLabs.com Fax 408.399.7001 Los Gatos, California 95030-7243 Voice 408.399.7000 S TITLE: PLI Evaluation Report (RFI) FCC ID: SAN5405X Page 24 of 50 DRAWING: Q540502W.02.DWG.doc Issued: 17 Jul 2004 Re-Issued: 11 Aug 2004 BY: Laura Bramschreiber and Clyde Pineda Approved: Lee Pulver FIGURE 4: PLI Photograph Number 5405C2734SJR-01 the rear view of the Equipment Under Test in Conducted Electromagnetic Interference Test Configuration #1.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

PePLink Surf 200BG/200BG-AP
Equipment Class
DTS - Digital Transmission System
PePLink Surf 200BG / -AP
Equipment Class
DTS - Digital Transmission System
PePLink PolePoint Outdoor 400BG
Equipment Class
DTS - Digital Transmission System
PePLink Surf 200BG
Equipment Class
DTS - Digital Transmission System
Intenet Access Router
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral