FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zalman Tech Co., Ltd./
  3. SAOZM600-HP

SAOZM600-HPPower supply unit

Zalman Tech Co., Ltd.
Power supply unit - FCC ID SAOZM600-HP - Zalman Tech Co., Ltd.
Click to zoom

Application Details

Equipment Class
JBC - Part 15 Class B Computing Device/Personal Computer
Date of Grant
Jan 01, 2007
Application Purpose
Original Equipment
Date of Application
Jan 01, 2007
Equipment Note
Power supply unit
Company
Zalman Tech Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1. Safety Precautions ▣ The following precautions and directions are measures against possible accidents and injuries. Please read them thoroughly before using this pro duct. Warning Neglecting the following may causeSerious injury or death. Caution Neglecting the following may cause minor injuries, degrade product conditions or cause malfuncion. 3. Notes on Installation *For more information on the pr oduct, please visit our website at www.zalman.co.kr . 2. Components 1) One Power Supply2) One Cable for CPU2 3) One Cable for PCI-E24) Three Cables for ODD/HDD5) Two Cables for S-ATA6) One Fan Dual-connector (ZM-DC1) (See page 4 for details) 7) One Power Cord for AC Power Source (Not included in some cou ntries) 8) One User ’ s Manual 9) Five Cable Ties ▶ Opening the cover of the product while the power cord is plugged into an outlet may cause electrocution or critical damage to the product. ▶ Handling the power cord with wet hands may cause in electrocution. ▶ Inserting fingers or metallic objects into the cooling fan may cause in injury or electrocution. ▶ Operating the product in an extremely cold or hot environment can degrade product performance and lifespan. ▶ Liquids that enter the product may cause malfunction. ▶ Operation in a humid or non-ventilated environment may reduce product lifespan. ▣ Plugging the main power connector P1 into the motherboard whil e the product is connected to the AC power source may result in damage to the motherboard. ▣ Make sure that the connectors are connected to their designate d locations, and that the connectors are not oriented in the wrong direction when connect ing the DC output connectors. ▣ If the Power on LED fails to light up when the main power butt on is pressed after completing the installation procedure, some devices may be connected incor rectly or the motherboard may be faulty. ※ To ensure a safe and easy installation, please read the safety precautions above and the following notes. 4. The Zalman Advantage Zalman ’ s CNPS products enable a noiseless computing environment, in accordance with our policy of developing people-friendly produc ts. This ultra-quiet power supply complies with ATX12V Version 2.2, and supports the Lastest dual-core CPUs(Intel Core2 series/AMD Athlon64-X2 series) , as well ass the Lastest dual graphic card systems(SLI/CrossFire). ▣ Heatpipe Installed for Maximum Cooling Performance and Ultra-Qu iet Operation A heatpipe with ultra-high cooling performance incorporated on t he power supply ’ s main Rectifiers enables high load operation even at low RPM for a dr amatic reduction in noise levels. ▣ Improved Power Factor & Reduced Harmonics through Active PFC By implementing Active PFC(Power Factor Correction), the Power F actor (PF) is improved from 75% (Passive PFC) up to 99% while harmful harmoni c frequencies are reduced to meet the line harmonic distortion requirements of I EC61000-3-2 Class D. ▣ High Efficiency Design This power supply is capable of reaching a maximum of 84% effic iency(230VAC, Full & Typical Load) through its of the use of high switching frequenc y and low power-loss circuitry. ▣ ATX20+4 Pin Main Connector ATX20+4 pin main connector broadens the range of motherboard co mpatibility. ▣ Supports ATX12V CPU 4-Pin and EPS12V CPU 8-Pin Two ATX12V CPU 2x2(4-Pin) power cables can be combined to form an E PS12V CPU 8-Pin power cable. ▣Dual PCI Express VGA Power 6-Pin Connector Supports Nvidia SLI and ATI CrossFire d ual graphic card systems. ▣ EZ Grip Connectors for ODDs & HDDs EZ Grip Connectors for easy removal of the plugs from ODDs & HDD s. ▣ Four Independent +12VDC Outputs Four +12VDC rails supply power independently to the CPU, VGA, m otherboard, and peripheral components for the highest level of stability and performance. ▣ Sleeved Cables All power cables are sleeved for easy cable management and impr oved air circulation inside the computer case. ▣ Ultra Quiet 120mm Fan Ultra quiet 2-Ball Bearing ADDA 120mm fan maximizes the airflow and minimizes the noise level enabling a noiseless computing environment with optimized cooling. ▣ Module Cables Module cables provide organized cable management and improved a ir circulation inside the computer case. ▣ Gold-Plated Terminals Gold-plating the terminals minimize power loss by reducing cont act resistance. ▣ WEEE & RoHS Complies to WEEE & RoHS Environm ental Directives of Europe. * WEEE : Waste Electrical a nd Electronic Regulations * RoHS : Restriction of Hazad ous Substances Regulations ▣ International Safety and EMC Certifications FCC IDENTIFIER : SAOZM600-HP E198072 ZMT-FC-ZP6HP(B) ▣ Multiple Safety Features Over-voltage Protection, Over-cu rrent Protection, Short-circuit Protection, Under-voltage Protection, Over-temperature Protection. ▣ Internal Blue LED Blue LEDs are installed inside the power supply for cool aesthet ics. * CNPS (Computer Noise Prevention System) refers to a system th at reduces a conventional computer ’ s noise lever (30dB or more) to an inaudible level (20dB or les s). Zalman ’ s silent/ultra-quiet computer s of the highest quality. ▣Output Power Cable Specifications Voltage Frequency AC Input Range 115VAC (Rated) 230VAC I min I max I peak PFC Type +3.3V 0.8A 24A Power Factor +5V 0.3A 24A Inrush Current Limit 115VAC +12V1 0A 16A (@ Cold start at 25°C) 230VAC +12V2 0A 16A Efficiency +12V3 1A 16A Vout +12V4 1A 16A +3.3VDC ±5% +3.14V ~ +3.47V -12V 0.0A 0.5A +5VDC ±5% +4.75V ~ +5.25V +5VSB 0.0A 2.5A 3.5A +12V1DC ±5% +11.4V ~ +12.6V+12V2DC ±5% +11.4V ~ +12.6V+12V3DC ±5% +11.4V ~ +12.6V+12V4DC ±5% +11.4V ~ +12.6V -12VDC ±10% -10.8V ~ -13.0V +5VSB ±5% +4.75V ~ +5.25V Vout +3.3VDC +5VDC +12V1DC+12V2DC+12V3DC+12V4DC -12VDC +5V SB DC Output Ripple & Noise DC Output Voltage Regulations Over-current Protection (OCP) Under-voltage Protection (UVP) Operation 0°C ~ +50°C Ambient Humidity Operation 5 %RH ~ 95 %RH Dimensions Specification 100mV At Full Load At Full Load Regulation Range 200mV200mV200mV100mV100mV Combined Power Protection Short…

Text truncated - open the document above for the full version.

Block Diagram

V in (DC) V out (DC) INPUT RFI FILTER AND SUGGE SUPPRESSION INPUT RECTIFIERS AND FILTERING TRANSFORMER RECTIFIERS AND FILTERS PROTECTION CIRCUITS V cc Protection START-UP Feedback Overrides IC SUPPLY POWER Drive Network & CONTROLLER DRIVE BIAS SWITCHES CIRCUIT Ground Ground TRANSFORMER RECTIFIERS AND FILTERS PROTECTION CIRCUITS +5Vsb POWER SWITCHES AND CONTROLLER Feedback Network Ground < ZM600-HP Block Diagram > +12V1DC +12V2DC +12V3DC +12V4DC +5VDC +3.3VDC -12VDC +5Vsb

External Photos

Appendix C. External Photographs Report no. ETLE061226.590, Page C1 of C1 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 Front view of EUT Rear view of EUT

ID Label/Location Info

Appendix A. FCC ID Label and Location Report no. ETLE061226.590, Page A1 of A1 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 Product Label Sample with FCC Label information Following is a sample copy of the label that will be placed on the rear cabinet of the product. The FCC ID Label and compliance statement are marked in the product label. ZALMAN TECH CO., LTD. Power Supply FCC ID : SAOZM600-HP Model No. : ZM600-HP Serial No. : N/A This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Manufacturer : SPI Electronics Co., Ltd. Made in Korea Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase.(Labeling requirements per 2.925) Label here

Internal Photos

Appendix D. Internal Photographs Report no. ETLE061226.590, Page D1 of D5 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 View of Inside Appendix D. Internal Photographs Report no. ETLE061226.590, Page D2 of D5 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 Top side view of main board Appendix D. Internal Photographs Report no. ETLE061226.590, Page D3 of D5 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 Bottom side view of main board Appendix D. Internal Photographs Report no. ETLE061226.590, Page D4 of D5 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 Top side view of sub board Appendix D. Internal Photographs Report no. ETLE061226.590, Page D5 of D5 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 Bottom side view of sub board

Operational Description

Operational Description Operational Description Operational Description Specification

Test Report

This report only responds to the tested sample and may not be reproduced, except in full, without written approval of the ETL Inc. www.etl.re.kr E-RAE Testing Laboratory Electromagnetic Emission FCC MEASUREMENT REPORT CERTIFICATION OF COMPLIANCE FCC Part 15 Certification Measurement This Power Supply, Model ZM600-HP has been tested in accordance with the measurement procedures specified in ANSI C63.4-2003 at the ETL EMC Test Laboratory and has been shown to be complied with the electromagnetic radiated emission limits specified in FCC Rule Part15 Subpart B: I attest to the accuracy of data. All measurement herein was performed by me or was made under my supervision and is correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. The results of testing in this report apply to the product/system which was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Chon Sik, Kim / Chief Engineer ETL Inc. #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 PRODUCT : Power Supply MODEL/TYPE NO : ZM600-HP FCC ID : SAOZM600-HP APPLICANT : ZALMAN TECH CO., LTD. #1007, Daeryung Techno Town III, 448 Gasan-dong, Gumchun-gu, Seoul, 153-803, Korea Attn.: Lee, Sang-Ju / Assistant manager MANUFACTURER : SPI Electronics Co., Ltd. No.22, Jianguo E., Taoyuan City Taiwan, R.O.C FCC CLASSIFICATION : Internal power supply used with Class B personal computers FCC RULE PART(S) : FCC Part 15 Subpart B FCC PROCEDURE : Certification TEST REPORT No. : ETLE061226.590 DATES OF TEST : December 27, 2006 REPORT ISSUE DATE : December 28, 2006 TEST LABORATORY : ETL Inc. ( FCC Registration Number : 95422) Report no. ETLE061226.590, Page 2 of 15 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 FCC TEST REPORT Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test Results 5.1 Summary of Test Results 5.2 Conducted Emissions Measurement 5.3 Radiated Emissions Measurement 5.4 Antenna Power Conduction Measurement 5.5 Picture Sensitivity 5.6 Noise figure measurement 6. Sample Calculation 7. List of test Equipment used for Measurement Appendix A. FCC ID Label and Location Appendix B. Test Setup Photographs Appendix C. External Photographs Appendix D. Internal Photographs Appendix E. Block Diagram Appendix F. User Manual Report no. ETLE061226.590, Page 3 of 15 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 FCC TEST REPORT FCC MEASUREMENT REPORT Scope – Measurement and determination of electromagnetic emission(EME) of radio frequency devices including intentional radiators and/or unintentional radiators for compliance with the technical rules and regulations of the U.S Federal Communications Commission(FCC) General Information z EUT Type : Power Supply z Model Number : ZM600-HP z FCC ID : SAOZM600-HP z S/N : N/A z FCC Rule Part(s) : FCC Part 15 Subpart B z Test Procedure : ANSI C63.4-2003 z FCC Classification : Internal power supply used with Class B personal computers z Dates of Tests : December 27, 2006 z Place of Tests : ETL Inc. Testing Lab. (FCC Registration Number : 95422) Radiated Emission test; #584, Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea Conducted Emission test; ETL Inc. Testing Lab. (FCC Registration Number : 95422) 371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea z Test Report No. : ETLE061226.590 Applicant Name : ZALMAN TECH CO., LTD. Address : #1007, Daeryung Techno Town III, 448 Gasan-dong, Gumchun-gu, Seoul, 153-803, Korea Attention : Lee, Sang-Ju / Assistant manager Report no. ETLE061226.590, Page 4 of 15 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 FCC TEST REPORT 1. INTRODUCTION The measurement test for radiated and conducted emission test were conducted at the ETL Inc. The site is constructed in conformance with the requirements of the ANSI C63.4-2003 and CISPR Publication 16. The ETL has site descriptions on file with the FCC for 3 m and 10 m site configurations. Detailed description of test facility was found to be in compliance with the requirements of Section 2.948 FCC Rules according to the ANSI C63.4-2003 and registered to the Federal Communications Commission (Registration Number : 95422 ). The measurement procedure described in American National Standard for Method of Measurement of Radio- Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (ANSI C63.4-2003) was used in determining radiated and conducted emissions from the ZALMAN TECH CO., LTD., Model: ZM600-HP. Report no. ETLE061226.590, Page 5 of 15 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 FCC TEST REPORT 2. PRODUCT INFORMATION 2.1 Equipment Description The Equipment Under Test (EUT) is the ZALMAN TECH CO., LTD., Model: ZM600-HP. 2.2 General Specification Voltage Frequency AC Input Range 115VAC (Rated) 230VACI min I max I peak PFC Type+3.3V 0.8A 24A Power Factor+5V 0.3A 24A Inrush Current Limit 115VAC+12V1 0A 16A (@ Cold start at 25°C) 230VAC+12V2 0A 16A Efficiency+12V3 1A 16A Vout+12V4 1A 16A +3.3VDC ±5% +3.14V ~ +3.47V-12V 0.0A 0.5A +5VDC ±5% +4.75V ~ +5.25V+5VSB 0.0A 2.5A 3.5A +12V1DC ±5% +11.4V ~ +12.6V +12V2DC ±5% +11…

Text truncated - open the document above for the full version.

Test Setup Photos

Appendix B. Test Setup Photographs Report no. ETLE061226.590, Page B1 of B2 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 Conducted Emission Test Setup Appendix B. Test Setup Photographs Report no. ETLE061226.590, Page B2 of B2 Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, 469-885, Korea ETLQP-21-F22-0 Radiated Emission Test Setup

Contact Information

Applicant

Sang Ju Lee(Technical Team / Assistant Manager)
[email protected]0082-2-2107-3134Fax: 0082-2-2107-3322

Test Firm

ETL IncKIM Chon Sik
[email protected]82-2-858-0786Fax: 82-2-858-0788

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--

Other Applications from Zalman Tech Co., Ltd.

WiFi Storage Device - FCC ID SAOZMWE450 - Zalman Tech Co., Ltd.
SAOZMWE450

WiFi Storage Device

Jan 16, 2014

Equipment Class

DTS - Digital Transmission System
Internal power supplies used with Class B PC - FCC ID SAOZM360B-APS - Zalman Tech Co., Ltd.
SAOZM360B-APS

Internal power supplies used with Class B PC

Jan 29, 2006

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Internal power supplies used with Class B PC - FCC ID SAOZM460B-APS - Zalman Tech Co., Ltd.
SAOZM460B-APS

Internal power supplies used with Class B PC

Jan 29, 2006

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
SMPS - FCC ID SAOTNN350APF-V1 - Zalman Tech Co., Ltd.
SAOTNN350APF-V1

SMPS

Jul 05, 2005

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Power Supply - FCC ID SAOZM460-APS - Zalman Tech Co., Ltd.
SAOZM460-APS

Power Supply

Apr 26, 2005

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral