SDBGFL2RMRemote Telemetry Module

Sensus Metering Systems Inc.

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Apr 19, 2012
Application Purpose
Original Equipment
Date of Application
Apr 19, 2012
Equipment Note
Remote Telemetry Module
Frequency Range
959.85000000 - 960.00000000
Company
Sensus Metering Systems Inc.
Country
United States

Documents & Files

Select a file to view

Cover Letter(s)

β†—
β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

RF Exposure Info

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Reliability and Compliance T: 919-317-6351 639 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com LETTER OF AUTHORIZATION Friday, March 09, 2012 To whom it may concern: I hereby appoint Sam Wismer of Advanced Compliance Solutions, Inc. to act as our agent in the preparation of an application for equipment authorization of the GFL2RM to the FCC Rules and Regulations. I certify that all exhibits contained within this filing properly describe the device or system for which authorization is sought. I further certify that appropriate arrangements have been made to assure that production units of this equipment bearing the name GFL2RM and FCC IDENTIFIER SDBGFL2RM listed in this application will continue to comply with the Commission's requirements. I further certify by signature below that no party (per 47 CFR 1.2002(b)) to the application is subject to a denial of Federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This appointment also includes the authority to complete FCC Form 731 on our behalf and sign the application as an authorized agent. This authorization is valid for GFL2RM ONLY, and shall not be utilized for any other matters on the behalf of Sensus. Sincerely, Al Servais | Reliability and Compliance Program Manager 639 Davis Drive | Morrisville, NC 27560 USA T: 919-317-6351 | C: 919-208-8983 | [email protected] | www.sensus.com

Cover Letter(s)

5015 B. U. Bowman Dr. Buford, GA 30518 April 12, 2012 ACS TCB 5015 B.U. Bowman Drive Buford, GA 30518 Re: FCC ID: SDBGFL2RM To Whom It May Concern: The following application is submitted on behalf of our client, Sensus Metering Systems, Inc., for evaluation of their model GFL2RM for certification under FCC Part 24 Subpart D and Part 101 Subpart C. The purpose of this application is to modular approve the GFL2RM transceiver. The GFL2RM is a stand- alone module consisting of a single printed circuit board which is designed to be integrated into specific host devices. The FCC ID: SDBGFL2RM was tested standalone and the radiated measurements were performed in the orientation of typical installation. The GFL2RM was tested in full to the requirements of the aforementioned rules and was found to be in compliance. Sincerely, Sam Wismer Vice President, Technology Advanced Compliance Solutions, Inc.

Cover Letter(s)

Reliability and Compliance T: 919-317-6351 639 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com 1 of 3 Sensus Non Sensus NonSensus Non Sensus Non- -- -Disclosure Disclosure Disclosure Disclosure Memorandum MemorandumMemorandum Memorandum March 9, 2012 Sensus OEMs: This memorandum serves as an additional agreement between Sensus and its OEMs stating that the OEMs will use the Sensus GFL2RM module (See Appendix 1) in accordance with the FCC rules on modular approved devices. The Sensus GFL2RM Transceiver is professionally installed inside various Sensus meters (See Appendix 2). The module label will be located either on the side of the host meter or on the front of the host meter and will display both the FCC and IC IDs of the GFL2RM module. Confidentiality of the internal photos and the technical manual is being requested because this is a non-consumer device which is not accessible by the general public, professionally installed, and is only serviceable by Sensus, or designated technicians. Please feel free to contact me directly should there be any questions regarding this matter . Respectfully, Al Servais | Reliability and Compliance Program Manager 400 Perimeter Park | Suite K | Morrisville, NC 27560 USA T: 919-379-1951 | C: 919-208-8983 | [email protected] | www.sensus.com 2 of 3 Sensus Non Sensus NonSensus Non Sensus Non- -- -Disclosure Memorandum Disclosure MemorandumDisclosure Memorandum Disclosure Memorandum Appendix 1 Appendix 1Appendix 1 Appendix 1 3 of 3 Sensus Non Sensus NonSensus Non Sensus Non- -- -Disclosure Memorandum Disclosure MemorandumDisclosure Memorandum Disclosure Memorandum Appendix 2 Appendix 2Appendix 2 Appendix 2

Cover Letter(s)

Reliability and Compliance T: 919-317-6351 639 Davis Drive F: 919-317-6210 Morrisville, NC 27560 USA www.sensus.com Friday, March 09, 2012 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: SDBGFL2RM Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Justification Schematic 11-2095 - Schematics.pdf Proprietary Information and Trade Secret Parts List 11-2095 - BOM_Parts List.pdf Proprietary Information and Trade Secret Theory Of Operation 11-2095 - Theory of Operation.pdf Proprietary Information and Trade Secret Manual 11-2095 - User Manual.pdf Proprietary Information and Trade Secret Internal Photos 11-2095 - Internal Photos.pdf Proprietary Information and Trade Secret Tune-Up Procedure 11-2095 - Tune-Up Procedure.pdf Proprietary Information and Trade Secret Block Diagram 11-2095 - Block Diagram.pdf Proprietary Information and Trade Secret Confidentiality of the Internal Photos is being requested because this is a non-consumer device which is not accessible by the general public and is only serviceable by the applicant or designated technicians. The Manual is technical and is not provided to the consumer because the consumer cannot service or install the device. Therefore confidentiality of the Manual is also requested. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The product covered by this Confidentiality Request may or may not be sold to any OEM and is only installed in Sensus Products by Sensus Employees or Contractors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Al Servais | Reliability and Compliance Program Manager 639 Davis Drive | Morrisville, NC 27560 USA T: 919-317-6351 | C: 919-208-8983 | [email protected] | www.sensus.com

External Photos

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Exhibit FCC ID: SDBGFL2RM IC: 2220A-GFL2RM FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101 Subpart C IC Radio Standards Specification: RSS 119, RSS 134 ACS Project: 11-2095 Manufacturer: Sensus Metering Systems, Inc. Model: GFL2RM External Photos Model: GFL2RM FCC ID: SDBGFL2RM IC: 2220A-GFL2RM The GFL2RM is a modular device in which internal photos have been held confidential. There are no associated external photographs considering the modular classification. ACS Project: 11-2095 Advanced Compliance Solutions Page 2

ID Label/Location Info

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Exhibit FCC ID: SDBGFL2RM IC: 2220A-GFL2RM FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101 Subpart C IC Radio Standards Specification: RSS 119, RSS 134 ACS Project: 11-2095 Manufacturer: Sensus Metering Systems, Inc. Model: GFL2RM Label Information Model: GFL2RM FCC ID: SDBGFL2RM IC: 2220A-GFL2RM Figure 1: Sample Label/Location (Top PCB) ACS Project: 11-2095 Advanced Compliance Solutions Page 2 Model: GFL2RM FCC ID: SDBGFL2RM IC: 2220A-GFL2RM Figure 2: Sample Label/Location (Bottom PCB) ACS Project: 11-2095 Advanced Compliance Solutions Page 3 Model: GFL2RM FCC ID: SDBGFL2RM IC: 2220A-GFL2RM Figure 3: Sample Host Label ACS Project: 11-2095 Advanced Compliance Solutions Page 4

RF Exposure Info

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Exhibit FCC ID: SDBGFL2RM IC: 2220A-GFL2RM FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101 Subpart C IC Radio Standards Specification: RSS 119, RSS 134 ACS Project Number: 11-2095 Manufacturer: Sensus Metering Systems, Inc. Model: GFL2RM RF Exposure Model: GFL2RM FCC ID: SDBGFL2RM IC: 2220A-GFL2RM ACS Project: 11-2095 Advanced Compliance Solutions Page 2 General Information: Applicant: Sensus Metering Systems, Inc. ACS Project: 11-2095 Device Category: Mobile Environment: General Population/Uncontrolled Exposure Technical Information: Antenna Type: Printed Dipole Antenna Gain: 0 dBi Maximum Transmitter Conducted Power: 28.47 dBm Maximum System EIRP: 28.47 dBm, 703.07 mW Exposure Conditions: Greater than 20 centimeters MPE Calculation The Power Density (mW/cm 2 ) is calculated as follows: S = 2 4R PG Ο€ Where: S = power density (in appropriate units, e.g. mW/cm2) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) 959.92528.470.64703.0701.000 200.140 Power Densit y (mW/cm^2) Distance (cm) Transmit Frequency (MHz) Radio Power (dBm) Power Density Limit (mW/Cm2) Radio Power (mW) Antenna Gain (dBi) Antenna Gain (mW eq.) Installation Guidelines The installation manual should contain text similar to the following advising how to install the equipment to maintain compliance with the FCC RF exposure requirements: RF Exposure In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 centimeters will be maintained. Conclusion This device complies with the MPE requirements by providing adequate separation between the device, any radiating structure and the general population.

Test Report

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Test Report FCC ID: SDBGFL2RM IC: 2220A-GFL2RM FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101 Subpart C IC Radio Standards Specification: RSS 119, RSS 134 ACS Report Number: 11-2095.W06.1A Applicant: Sensus Metering Systems, Inc. Model: GFL2RM Test Begin Date: March 7, 2012 Test End Date: March 29, 2012 Report Issue Date: April 10, 2012 For The Scope of Accreditation Under Certificate Number AT-1533 For The Scope of Accreditation Under Lab Code 200612-0 This report must not be used by the client to claim product certification, approval, or endorsement by ACLASS, NVLAP, ANSI, or any agency of the Federal Government. Project Manager: Reviewed by: Thierry Jean-Charles Kirby Munroe EMC Engineer Director, Wireless Certifications Advanced Compliance Solutions, Inc. Advanced Compliance Solutions, Inc. This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this report are representative of the sample(s) submitted for evaluation. This report contains 46 pages ACS Report: 11-2095.W06.1A Advanced Compliance Solutions Page 2 of 46 Table of Content 1.0 GENERAL----------------------------------------------------------------------------------------------------------------------3 1.1 PURPOSE---------------------------------------------------------------------------------------------------------------------3 1.2 PRODUCT DESCRIPTION----------------------------------------------------------------------------------------------------3 1.3 TEST METHODOLOGY-------------------------------------------------------------------------------------------------------3 1.4 EMISSION DESIGNATORS---------------------------------------------------------------------------------------------------4 2.0 TEST FACILITIES-----------------------------------------------------------------------------------------------------------5 2.1 LOCATION---------------------------------------------------------------------------------------------------------------------5 2.2 LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS-------------------------------------------------5 2.3 RADIATED & CONDUCTED EMISSIONS TEST SITE DESCRIPTION-----------------------------------------------------6 3.0 APPLICABLE STANDARD REFERENCES--------------------------------------------------------------------------8 4.0 LIST OF TEST EQUIPMENT----------------------------------------------------------------------------------------------9 6.0 EQUIPMENT UNDER TEST SETUP AND BLOCK DIAGRAM------------------------------------------------ 10 7.0 SUMMARY OF TESTS--------------------------------------------------------------------------------------------------- 11 7.1 RF POWER OUTPUT------------------------------------------------------------------------------------------------------ 11 7.2 OCCUPIED BANDWIDTH (EMISSION LIMITS)--------------------------------------------------------------------------- 16 7.3 SPURIOUS EMISSIONS AT ANTENNA TERMINALS--------------------------------------------------------------------- 31 7.4 FIELD STRENGTH OF SPURIOUS EMISSIONS-------------------------------------------------------------------------- 38 7.5 FREQUENCY STABILITY--------------------------------------------------------------------------------------------------- 42 8.0 CONCLUSION-------------------------------------------------------------------------------------------------------------- 46 Model: GFL2RM FCC ID: SDBGFL2RM IC:2220A-GFL2RM ACS Report: 11-2095.W06.1A Advanced Compliance Solutions Page 3 of 46 1.0 GENERAL 1.1 Purpose The purpose of this report is to demonstrate compliance with Part 2 Subpart J, Part 24 Subpart D and Part 101 Subpart C of the FCC’s Code of Federal Regulations, and Industry Canada Radio Standards Specifications RSS-119 and RSS-134 for a modular approval. 1.2 Product Description The Sensus GFL2RM Smartpoint is a battery operated 900 MHz wireless module. The unit is designed so that it can be remotely connected to 2 separate gas meters. Manufacturer Information: Sensus Metering Systems, Inc. 639 Davis Drive Morrisville, NC 27560 Test Sample Serial Numbers: 024400026 (Radiated), 024000238 (RF Conducted) Test Sample Condition: The unit was in good operating conditions with no physical damages. 1.3 Test Methodology 1.3.1 Configurations and Justification The GFL2RM was evaluated for radiated emissions and RF conducted measurements. The radiated emissions investigation was performed up to the 10th harmonic with the EUT standalone while set in the orientation of typical operation. A unit with a temporary SMA connector was provided for the RF evaluation at the antenna port. The evaluation for unintentional emission is documented separately in a verification report. Model: GFL2RM FCC ID: SDBGFL2RM IC:2220A-GFL2RM ACS Report: 11-2095.W06.1A Advanced Compliance Solutions Page 4 of 46 1.3.2 In-Band Testing Methodology The EUT is designed to operate in multiple bands under the requirements of CFR 47 Parts 24 and 101. The following is a list of the frequency bands of operation sorted based on the FCC rule parts in which the band is associated. CFR Title 47 Rule Part Frequency Band of Operation (MHz) 24D 901.0 - 902.0 24D 930.0 - 931.0 24D 940.0 - 941.0 101 928.85 - 929.0 101 932.0 - 932.5 101 941.0 - 941.5 101 959.85 - 960.0 Based on the requirements set forth in accordance 47 CFR 2.1046-2.1057 as stated above, the methodology in selecting the places to test in the available bands of operation is outlined in the following table. CFR Title 47 Rule Part Frequency Band of Operation (MHz) Location in the Range of Operation Approx. Test Freq. 24D 901.0 - 902.0 Middle 901.5000 101 928.85 - 929.0 Middle 928.9250 24D 930.0 - 931.0 Middle 930.5000 101 932.0 - 932.5 Middle 932.2500 24D 940.0 - 941.0 940.0125 101 941.0 - 941.5 1 near top and 1 near bottom 941.4875 101 959.85 – 960.0 M…

Text truncated - open the document above for the full version.

Test Setup Photos

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Exhibit FCC ID: SDBGFL2RM IC: 2220A-GFL2RM FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101 Subpart C IC Radio Standards Specification: RSS 119, RSS 134 ACS Project: 11-2095 Manufacturer: Sensus Metering Systems, Inc. Model: GFL2RM Test Setup Photos Model: GFL2RM FCC ID: SDBGFL2RM IC: 2220A-GFL2RM Figure 1: Radiated Emissions – Front View ACS Project: 11-2095 Advanced Compliance Solutions Page 2 Model: GFL2RM FCC ID: SDBGFL2RM IC: 2220A-GFL2RM Figure 2: Radiated Emissions – Back View ACS Project: 11-2095 Advanced Compliance Solutions Page 3 Model: GFL2RM FCC ID: SDBGFL2RM IC: 2220A-GFL2RM Figure 3: RF Conducted Emissions ACS Project: 11-2095 Advanced Compliance Solutions Page 4

Contact Information

Applicant

Ray Britt(Senior Director, Global System Test)
[email protected]919-665-7878Fax: 919-317-6210

Test Firm

Advanced Compliance Solutions, Inc.Sam Wismer
[email protected]561-961-5585

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
17101C959.85 MHz - 960 MHz703.00 mW11K8F1D1.5 ppm
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Modular Approval. Power listed is conducted. This Modular Approval is limited to installation for mobile and fixed applications only. This grant is valid only when the device is installed by the grantee or contractors employed by the grantee who are instructed to ensure that the end-user has no manual instructions to remove or install the device. The transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Sensus Metering Systems Inc.

Command Link II Wireless Interface - FCC ID SDBCL202 - Sensus Metering Systems Inc.
SDBCL202

Command Link II Wireless Interface

Mar 09, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Remote Telemetry Module - FCC ID SDBWFL3 - Sensus Metering Systems Inc.
SDBWFL3

Remote Telemetry Module

Mar 04, 2026

Equipment Class

DTS - Digital Transmission System
SDBIDTB007

Stratus IQ+ Radio Module

Sep 28, 2023

Equipment Class

PCB - PCS Licensed Transmitter
Base Station Transceiver - FCC ID SDBM420V01 - Sensus Metering Systems Inc.
SDBM420V01

Base Station Transceiver

Jan 05, 2023

Equipment Class

PCB - PCS Licensed Transmitter
Base Station Transceiver - FCC ID SDBM420V00 - Sensus Metering Systems Inc.
SDBM420V00

Base Station Transceiver

Jan 05, 2023

Equipment Class

PCB - PCS Licensed Transmitter