FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sensus Metering Systems Inc./
  3. SDBTGB20

SDBTGB20BASE STATION TRANSCEIVER

Sensus Metering Systems Inc.
BASE STATION TRANSCEIVER - FCC ID SDBTGB20 - Sensus Metering Systems Inc.
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Oct 30, 2011
Application Purpose
Original Equipment
Date of Application
Oct 27, 2011
Equipment Note
BASE STATION TRANSCEIVER
Frequency Range
959.85000000 - 960.00000000
Company
Sensus Metering Systems Inc.
Country
United States

Documents & Files

Select a file to view

Cover Letter(s)

β†—
β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

RF Exposure Info

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

400 Perimeter Park Drive T: 919-379-1951 Suite K F: 919-463-7706 Morrisville, NC 27560 USA www.sensus.com 1 of 3 Sensus Non Sensus NonSensus Non Sensus Non- -- -Disclosure Disclosure Disclosure Disclosure Memorandum MemorandumMemorandum Memorandum July 20, 2011 Sensus OEMs: This memorandum serves as an additional agreement between Sensus and its OEMs stating that the OEMs will use the Sensus TGB20 (See Appendix 1) in accordance with the FCC. The Sensus TGB20 Transceiver is professionally installed. The regulatory label will be located on the rear of the enclosure and will display both the FCC ID of the TGB20. Confidentiality of the internal photos and the technical manual is being requested because this is a non-consumer device which is not accessible by the general public (See Appendix 2), which is professionally installed, and is only serviceable by Sensus, or designated technicians. When installed, the Sensus TGB20 cannot be accessed by anyone other than Sensus staff or designated technicians simply because the product is located within and enclosure that is key-locked within a utility or Sensus owned and access controlled area. Please feel free to contact me directly should there be any questions regarding this matter . Respectfully, Al Servais | Reliability and Compliance Program Manager 400 Perimeter Park | Suite K | Morrisville, NC 27560 USA T: 919-379-1951 | C: 919-208-8983 | [email protected] | www.sensus.com 2 of 3 Sensus Non Sensus NonSensus Non Sensus Non- -- -Disclosure Memorandum Disclosure MemorandumDisclosure Memorandum Disclosure Memorandum Appendix 1 Appendix 1Appendix 1 Appendix 1 3 of 3 Sensus Non Sensus NonSensus Non Sensus Non- -- -Disclosure Memorandum Disclosure MemorandumDisclosure Memorandum Disclosure Memorandum Appendix 2 Appendix 2Appendix 2 Appendix 2 Example Enclosure of the TGB20

Cover Letter(s)

5015 B. U. Bowman Dr. Buford, GA 30518 September 8, 2011 ACS TCB 5015 B.U. Bowman Drive Buford, GA 30518 Re: FCC ID: SDBTGB20 To Whom It May Concern: The following application is submitted on behalf of our client, Sensus Metering Systems, for evaluation of their model TGB20 for certification under FCC Part 24 Subpart D and Part 101 Subpart C. The TGB20 is a base station for the Sensus Metering Systems meters. The device receives telemetry transmission from multiple system end point units used mostly for utility metering. The TGB20 sends also command information to the end point units. The TGB20 transceiver is housed in a rack mountable enclosure and is powered by 24 VDC. Sincerely, Sam Wismer Vice President, Technology Advanced Compliance Solutions, Inc.

Cover Letter(s)

400 Perimeter Park Drive T: 919-379-1951 Suite K F: 919-463-7706 Morrisville, NC 27560 USA www.sensus.com LETTER OF AUTHORIZATION 8/23/2011 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: I hereby appoint Sam Wismer of Advanced Compliance Solutions, Inc. to act as our agent in the preparation of an application for equipment authorization of the SDBTGB20 to the FCC Rules and Regulations. I certify that all exhibits contained within this filing properly describe the device or system for which authorization is sought. I further certify that appropriate arrangements have been made to assure that production units of this equipment bearing the name TGB20 and FCC IDENTIFIER SDBTGB20 listed in this application will continue to comply with the Commission's requirements. I further certify by signature below that no party (per 47 CFR 1.2002(b)) to the application is subject to a denial of Federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This appointment also includes the authority to complete FCC Form 731 on our behalf and sign the application as an authorized agent. This authorization is valid for TGB20 ONLY, and shall not be utilized for any other matters on the behalf of Sensus. Sincerely, Al Servais | Reliability and Compliance Program Manager 400 Perimeter Park Drive | Suite K | Raleigh, NC 27560 USA T: 919-379-1951 | C: 919-208-8983 | [email protected] | www.sensus.com

Cover Letter(s)

400 Perimeter Park Drive T: 919-379-1951 Suite K F: 919-463-7706 Morrisville, NC 27560 USA www.sensus.com August 29, 2011 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: SDBTGB20 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Justification Schematic 11-2071 – Schematics.pdf Proprietary Information and Trade Secret Parts List/BOM 11-2071 – Parts List_BOM.pdf Proprietary Information and Trade Secret Theory Of Operation 11-2071 – Theory of Operation.pdf Proprietary Information and Trade Secret Manual 11-2071 – Manual.pdf Proprietary Information and Trade Secret Internal Photos 11-2071 – Internal Photos.pdf Proprietary Information and Trade Secret Tune-Up Procedure 11-2071 – Tune-up Procedure.pdf Proprietary Information and Trade Secret Block Diagram 11-2071 – Block Diagram.pdf Proprietary Information and Trade Secret Confidentiality of the Internal Photos is being requested because this is a non-consumer device which is not accessible by the general public and is only serviceable by the applicant or designated technicians. The Manual is technical and is not provided to the consumer because the consumer cannot service or install the device. Therefore confidentiality of the Manual is also requested. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The product covered by this Confidentiality Request maybe sold to an OEM and is only installed in Sensus Products by Sensus Employees or Sensus Contractors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Al Servais | Reliability and Compliance Program Manager 400 Perimeter Park Drive | Suite K | Raleigh, NC 27560 USA T: 919-379-1951 | C: 919-208-8983 | [email protected] | www.sensus.com

External Photos

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Exhibit FCC ID: SDBTGB20 FCC Rule Part: 24 and 101 ACS Project: 11-2071 Manufacturer: Sensus Metering Systems, Inc. Model: TGB20 External Photos Model: TGB20 FCC ID: SDBTGB20 Figure 1: TGB20 – Front View ACS Project: 11-2071 Advanced Compliance Solutions Page 2 Model: TGB20 FCC ID: SDBTGB20 Figure 2: TGB20 – Rear View ACS Project: 11-2071 Advanced Compliance Solutions Page 3 Model: TGB20 FCC ID: SDBTGB20 Figure 3: TGB20 – Top View ACS Project: 11-2071 Advanced Compliance Solutions Page 4 Model: TGB20 FCC ID: SDBTGB20 Figure 4: TGB20 – Bottom View ACS Project: 11-2071 Advanced Compliance Solutions Page 5 Model: TGB20 FCC ID: SDBTGB20 Figure 5: TGB20 – Left Side View ACS Project: 11-2071 Advanced Compliance Solutions Page 6 Model: TGB20 FCC ID: SDBTGB20 Figure 6: TGB20 – Right Side View ACS Project: 11-2071 Advanced Compliance Solutions Page 7

ID Label/Location Info

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Exhibit FCC ID: SDBTGB20 FCC Rule Part: 24 and 101 ACS Project: 11-2071 Manufacturer: Sensus Metering System, Inc. Model: TGB20 Label Information Model TGB20 FCC ID: SDBTGB20

RF Exposure Info

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Exhibit FCC ID: SDBTGB20 FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101 Subpart C ACS Project Number: 11-2071 Manufacturer: Sensus Metering Systems, Inc. Model: TGB20 RF Exposure Model: TGB20 FCC ID: SDBTGB20 General Information: Applicant: Sensus Metering System, Inc. ACS Project: 11-2071 Device Category: Fixed Environment: General Population/Uncontrolled Exposure Technical Information: Antenna Type: Monopole Antenna Antenna Gain: 12.15 dBi Maximum Transmitter Conducted Power: 46.52 dBm Maximum System EIRP: 58.67 dBm Exposure Conditions: Greater than 310 centimeters MPE Calculation The Power Density (mW/cm 2 ) is calculated as follows: Where: S = power density (in appropriate units, e.g. mW/cm2) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) MPE Calculator for Mobile Equipment Limits for General Population/Uncontrolled Exposure* 930.546.520.6244874.5412.1516.406 3100.610 Power De nsity (mW/cm^2) Dista nce (cm) Transmit Frequency (MHz) Radio Power (dBm) Power Density Limit (mW/Cm2) Radio Power (mW) Ante nna Gain (dBi) Ante nna Gain (mW eq.) Installation Guidelines The installation manual should contain text similar to the following advising how to install the equipment to maintain compliance with the FCC RF exposure requirements: RF Exposure In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 310 centimeters will be maintained. Conclusion This device complies with the MPE requirements by providing adequate separation between the device, any radiating structure and the general population. ACS Project: 11-2071 Advanced Compliance Solutions Page 2

Test Report

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Test Report FCC ID: SDBTGB20 FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101 Subpart C ACS Report Number: 11-2071.W03.11.A This report contains data that is not covered by the scope of accreditation Applicant: Sensus Metering Systems, Inc. Model: TGB20 Test Begin Date: August 15, 2011 Test End Date: August 26, 2011 Report Issue Date: September 14, 2011 FOR THE SCOPE OF ACCREDITATION UNDER CERTIFICATE NUMBER AT-1533 This report must not be used by the client to claim product certification, approval, or endorsement by ACLASS, ANSI, or any agency of the Federal Government. Project Manager: Reviewed by: Thierry Jean-Charles Kirby Munroe EMC Engineer Director, Wireless Certifications Advanced Compliance Solutions, Inc. Advanced Compliance Solutions, Inc. This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this report are representative of the sample(s) submitted for evaluation. This report contains 27 pages ACS Report: 11-2071.W03.11.A Advanced Compliance Solutions Page 2 of 27 Table of Content 1.0 GENERAL----------------------------------------------------------------------------------------------------------------------3 1.1 PURPOSE---------------------------------------------------------------------------------------------------------------------3 1.2 PRODUCT DESCRIPTION----------------------------------------------------------------------------------------------------3 1.3 TEST METHODOLOGY-------------------------------------------------------------------------------------------------------3 1.3.1 CONFIGURATIONS AND JUSTIFICATION----------------------------------------------------------------------------3 1.4 EMISSION DESIGNATORS---------------------------------------------------------------------------------------------------4 2.0 TEST FACILITIES-----------------------------------------------------------------------------------------------------------5 2.1 LOCATION---------------------------------------------------------------------------------------------------------------------5 2.2 LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS-------------------------------------------------5 2.3 RADIATED & CONDUCTED EMISSIONS TEST SITE DESCRIPTION-----------------------------------------------------6 3.0 APPLICABLE STANDARD REFERENCES--------------------------------------------------------------------------7 4.0 LIST OF TEST EQUIPMENT----------------------------------------------------------------------------------------------8 6.0 EQUIPMENT UNDER TEST SETUP AND BLOCK DIAGRAM--------------------------------------------------9 7.0 SUMMARY OF TESTS--------------------------------------------------------------------------------------------------- 10 7.1 RF POWER OUTPUT------------------------------------------------------------------------------------------------------ 10 7.2 OCCUPIED BANDWIDTH (EMISSION LIMITS)--------------------------------------------------------------------------- 13 7.3 SPURIOUS EMISSIONS AT ANTENNA TERMINALS--------------------------------------------------------------------- 17 7.4 FIELD STRENGTH OF SPURIOUS EMISSIONS-------------------------------------------------------------------------- 22 7.5 FREQUENCY STABILITY--------------------------------------------------------------------------------------------------- 24 8.0 CONCLUSION-------------------------------------------------------------------------------------------------------------- 27 Model: TGB20 FCC ID: SDBTGB20 ACS Report: 11-2071.W03.11.A Advanced Compliance Solutions Page 3 of 27 1.0 GENERAL 1.1 Purpose The purpose of this report is to demonstrate compliance with Part 2 Subpart J, Part 24 Subpart D and Part 101 Subpart C of the FCC’s Code of Federal Regulations. 1.2 Product Description The TGB20 is a base station for the Sensus Metering Systems meters. The device receives telemetry transmission from multiple system end point units used mostly for utility metering. The TGB20 sends also command information to the end point units. The TGB20 transceiver is housed in a rack mountable enclosure and is powered by 24 VDC. Manufacturer Information: Sensus Metering Systems, Inc. 400 Perimeter Park Drive, Suite K Morrisville, NC 27560 Test Sample Serial Numbers: 2078 Test Sample Condition: TheTGB20 was in good physical condition with no noticeable damages. 1.3 Test Methodology 1.3.1 Configurations and Justification The TGB20 was evaluated for compliance to the radiated and RF conducted emissions requirements. The radiated spurious emissions were evaluated up to the 10 th harmonic. The EUT was tested in the MPass (5k) mode. Compliance to the radiated and power line conducted emissions requirements are documented separately in a Verification Report. 1.3.2 In-Band Testing Methodology The EUT is designed to operate in multiple bands under the requirements of CFR 47 Parts 24 and 101. The following is a list of the frequency bands of operation sorted based on the FCC rule parts in which the band is associated. CFR Title 47 Rule Part Frequency Band of Operation (MHz) 24D 930.0 - 931.0 24D 940.0 - 941.0 101 941.0 - 941.5 101 959.85 - 960.0 Based on the requirements set forth in accordance 47 CFR 2.1046-2.1057 as stated above, the methodology in selecting the places to test in the available bands of operation is outlined in the following table. Model: TGB20 FCC ID: SDBTGB20 ACS Report: 11-2071.W03.11.A Advanced Compliance Solutions Page 4 of 27 CFR Title 47 Rule Part Frequency Band of Operation (MHz) Location in the Range of Operation Approx. Test Freq. 24D 930.0 - 931.0 Middle 930.5 24D 940.0 - 941.0 940.0125 101 941.0 - 941.5 1 near top and 1 near bottom 941.4875 101 959.85 - 960.0 Middle 959.925 1.4 Emission Designators The TGB20 transmitter produces 1 distinct modulation format. The emissions designators for the modulatio…

Text truncated - open the document above for the full version.

Test Setup Photos

3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587 Certification Exhibit FCC ID: SDBTGB20 FCC Rule Part: 24 and 101 ACS Project: 11-2071 Manufacturer: Sensus Metering Systems, Inc. Model: TGB20 Test Setup Photos Model: TGB20 FCC ID: SDBTGB20 Figure 1: Radiated Emissions – Front View ACS Project: 11-2071 Advanced Compliance Solutions Page 2 Model: TGB20 FCC ID: SDBTGB20 Figure 2: Radiated Emissions – Back View ACS Project: 11-2071 Advanced Compliance Solutions Page 3 Model: TGB20 FCC ID: SDBTGB20 Figure 3: RF Conducted Emissions (Set Up 1) ACS Project: 11-2071 Advanced Compliance Solutions Page 4 Model: TGB20 FCC ID: SDBTGB20 Figure 4: RF Conducted Emissions (Set Up 2) ACS Project: 11-2071 Advanced Compliance Solutions Page 5 Model: TGB20 FCC ID: SDBTGB20 Figure 5: RF Conducted Emissions (Set Up 3) ACS Project: 11-2071 Advanced Compliance Solutions Page 6

Contact Information

Applicant

Ray Britt(Senior Director, Global System Test)
[email protected]919-665-7878Fax: 919-317-6210

Test Firm

Advanced Compliance Solutions, Inc.Sam Wismer
[email protected]561-961-5585

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
4101C959.85 MHz - 960 MHz32.36 W5K90F1D1.5 ppm
Confidentiality
Long Term
Grant Notes
Power listed is conducted. Device is limited to mobile and fixed applications only. The transmitter must be installed to provide a separation distance of at least 310 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Sensus Metering Systems Inc.

Command Link II Wireless Interface - FCC ID SDBCL202 - Sensus Metering Systems Inc.
SDBCL202

Command Link II Wireless Interface

Mar 09, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Remote Telemetry Module - FCC ID SDBWFL3 - Sensus Metering Systems Inc.
SDBWFL3

Remote Telemetry Module

Mar 04, 2026

Equipment Class

DTS - Digital Transmission System
SDBIDTB007

Stratus IQ+ Radio Module

Sep 28, 2023

Equipment Class

PCB - PCS Licensed Transmitter
Base Station Transceiver - FCC ID SDBM420V01 - Sensus Metering Systems Inc.