Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User guide BLUE: Autonomous logger 2 x 4-20 mA inputs, Modbus input/output and 2 digital inputs Ijinus user manual User manual K0J00121 IJINUS - 25 ZA de Kervidanou 3, 29300 MELLAC - France - – Customer Service: +33 2 98 09 03 32 / [email protected] 2 CONTENTS 1. Introduction .................................................................................................................................................................... 4 2. Document Information .................................................................................................................................................... 5 3. Safety Instructions ........................................................................................................................................................... 6 4. Equipment Description .................................................................................................................................................... 7 4.1. Turning on the logger .............................................................................................................................................. 7 4.2. Mounting the logger ............................................................................................................................................... 8 4.3. Connecting the sensors ........................................................................................................................................... 8 5. BLUE logger: analog, Modbus and digital inputs ............................................................................................................. 9 5.1. Description .............................................................................................................................................................. 9 5.2. Applications available with Avelour ...................................................................................................................... 11 6. External battery and mains power supply ..................................................................................................................... 12 6.1. In the case of an external battery ......................................................................................................................... 12 6.2. In the case of a mains power supply ..................................................................................................................... 12 7. Setting up a logger with Avelour software .................................................................................................................... 13 7.1. Equipment required .............................................................................................................................................. 13 7.2. Run Avelour and connect to the logger to be configured ..................................................................................... 14 7.3. General Information and Logger Name ................................................................................................................. 16 8. Applications available with a Blue logger: ..................................................................................................................... 18 8.1. Application: B&C Sensor ........................................................................................................................................ 18 8.2. Application: Modbus Output ................................................................................................................................. 23 8.3. Application: ModBus Flowmeter ........................................................................................................................... 26 8.4. Application: DI Input ............................................................................................................................................. 31 8.5. Application: 100 Hz counter .................................................................................................................................. 33 8.6. Application: 4-20mA measure ............................................................................................................................... 36 9. System Options: ............................................................................................................................................................ 44 9.1. Time zone .............................................................................................................................................................. 44 9.2. Power Management .............................................................................................................................................. 45 10. Pair a device .................................................................................................................................................................. 49 11. Data transmission .......................................................................................................................................................... 52 11.1. Modem Settings ................................................................................................................................................ 53 11.2. Modem diagnosis .............................................................................................................................................. 54 11.3. Alarm Settings ................................................................................................................................................... 56 11.4. Data transmission by SMS ................................................................................................................................. 56 11.5. Data transmission by internet ...................................................................................................................…
Text truncated - open the document above for the full version.
Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: February 29, 2024 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: SE6H001 IJINUS (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Link: List of Equipment and Services Covered By Section 2 of The Secure Networks Act Sincerely, IJINUS Marc MOREAU (COO Claire Connect) Signature: Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: February 29, 2024 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: SE6H001 IJINUS (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Link: List of Equipment and Services Covered By Section 2 of The Secure Networks Act Sincerely, IJINUS Marc MOREAU (COO Claire Connect) Signature:
V02072023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: May 31, 2024 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: SE6H001 IJINUS certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. IJINUS accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance consulting, LLC dba iCertifi FCC FRN: 0033399411 Address: 2445 NE Division Street, Suite 202 Bend, OR 97703 United States Contact Person: Paul Preston Tel: 866-885-4575 Email: [email protected] Sincerely, IJINUS FRN : 0020163960 Americas Compliance Consulting LLC dba iCertifi Marc MOREAU , COO Claire Connect Paul Preston
Letter of Agency February 29, 2024 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046-1609 Timco Engineering, Inc. 13146 NW 86th Drive, Suite 400 Alachua, FL 32615- United States We, the undersigned IJINUS hereby authorizes Majid MOURZAGH, LCIE SUD EST, to act on our behalf in all matters relating to all processes required for FCC certification of our devices. Any and all acts carried out by the above agent on our behalf shall have the same effects as acts of our own. This authorization is valid until: June 30th , 2024 If you have any questions regarding this authorization, let us know please. Sincerely, Marc MOREAU Signature:
COVER LETTER IJINUS – H0102 FCC ID: SE6H001 February 29, 2024 This report concerns: File : Original Grant SubPart: SubPart 15B Equipment type : Autonomous logger Request issue of grant : __ Immediately upon completion of review ___ Defer grant per 47 CFR 0.457(d)(1)(ii) until ____ date _____. Company Name agrees to notify the Commission by _____date_____ of the intended date of announcement of the product so that the grant can be issued on that date. Confidentiality of grant : __ Applicant requests the existence of this grant to be kept confidential until ____date____. The announcement of this product before this date via freedom of information would be detrimental to Company Name, and therefore must be considered a business secret. Public announcement of this product will not be made prior to this date. (Max. 60 days after grant issued). Limits used : (check one) CISPR 22: ______ Part15: ______ Measurement procedure used is ANSI C63.4-2014 / C63.10-2013 unless another is specified. Other test procedure : ____________________________________________________ Application for verification Applicant for this device Prepared by : Majid MOURZAGH LCIE Sud-Est ZI Centr’Alp – 170, rue de Chatagnon 38430 MOIRANS - France Ph. : 33 4 76 07 36 36 Fax : 33 4 76 55 90 88 e-mail : [email protected] FRN : 0005-0971-18 Marc MOREAU IJINUS 25 ZA de Kervidanou 3 29300 - MELLAC - France Ph. : +33 +33298090330 Fax : +33 +33298962901 e-mail: [email protected] FRN : 0020163960 Signature : Signature : *Not to be filed with Equipment Authorization Branch of FCC unless requested Report format prepared by the Information Technology Industry Council (ITI) ESC-5 and reviewed by FCC staff in 1994
CONFIDENTIALITY REQUEST To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046-1609 Cc: Timco Engineering, Inc. 13146 NW 86th Drive, Suite 400 Alachua, FL 32615- United States February 29, 2024 Subject: Confidentiality request FCC ID: SE6H001 IJINUS requests, pursuant to 47CFR 0.457 and 0.459, post grant confidentiality for portions of the material contained in this application. The following document regarding this submission for FCC ID: SE6H001 shall be kept confidential: LONG-TERM CONFIDENTIALITY: 1. Block Diagram description of the equipment (file: Block Diagram - SE6H001.pdf) 2. Operational description of the equipment (file: Operational Description -SE6H001.pdf) 3. Schematic Diagram of the equipment (file: Schematic -SE6H001.pdf) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Responsible party: Marc MOREAU Title: COO Claire Connect Signature:
Technical Documentation External Photos FCC ID : SE6H001 IC ID : 10983A-A002 Publication History Version Date Modification description 01 June 10, 2024 Creation of the document Technical Documentation External Photos Version : 01 Page 2/8 BLUE LOGGER BLUE-LP LOGGER (With integrated pressure sensor) Front View Technical Documentation External Photos Version : 01 Page 3/8 BLUE LOGGER BLUE-LP LOGGER Rear View Technical Documentation External Photos Version : 01 Page 4/8 BLUE LOGGER & BLUE-LP LOGGER Right side View Technical Documentation External Photos Version : 01 Page 5/8 BLUE LOGGER & BLUE-LP LOGGER Left side View Technical Documentation External Photos Version : 01 Page 6/8 BLUE LOGGER & BLUE-LP LOGGER Top View Technical Documentation External Photos Version : 01 Page 7/8 BLUE LOGGER BLUE-LP LOGGER Bottom View Technical Documentation External Photos Version : 01 Page 8/8 Antenna for optional commination daughter board use Accessories
Technical Documentation Label Location FCC ID : SE6H001 IC ID : 10983A-H001 Publication History Version Date Modification description 01 February 16, 2024 Creation of the document Technical Documentation Label Location Version : 01 Page 2/2 Label Location View
Technical Documentation Label FCC ID : SE6H001 IC ID : 10983A-H001 Publication History Version Date Modification description 01 February 16, 2024 Creation of the document Technical Documentation Label Version : 01 Page 2/3 H001 – FCC/IC FRONT LABEL – 89 x 55mm BLUE LOGGER - FRONT LABBEL BLUE-LP LOGGER - FRONT LABBEL Technical Documentation Label Version : 01 Page 3/3 H001 – FCC/IC BACK LABEL – 89 x 55mm Device without communication daughter board Device with Quectel BG95 based communication daughter board Device with UBLOX R422 based communication daughter board Device with Nemeus MM002XUS based communication daughter board Label View (1)
Technical Documentation Internal Photos FCC ID : SE6H001 IC ID : 10983A-A002 Publication History Version Date Modification description 01 June 10, 2024 Creation of the document Technical Documentation Internal Photos Version : 01 Page 2/4 Device without communication Device equipped with a communication daughter board daughter board Device Open View Technical Documentation Internal Photos Version : 01 Page 3/4 MB_129 : mother board (card integrated in all products) DB_164 : optional communication daughter board (Modem : Quectel BG95) DB_130-1 : optional communication daughter board (Modem : UBLOX SARA U201) DB_130-2 : optional communication daughter board (Modem : UBLOX SARA R422) DB_132 : optional communication daughter board (Modem : NEMEUS MM002-xx-US) DB_Connector : connector used to assemble daughter board to mother board Electronic Card Recto View (1) Technical Documentation Internal Photos Version : 01 Page 4/4 Electronic Card Recto View (1)
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE FCCID: SE6H001 Equation from page 18 of OET Bulletin 65, Edition 97-01 where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Prediction Frequency MHz Conducted Output Power dBm Max Antenna Gain dBi Distance cm Power Density mW/cm2 Limit mW/cm2 915 9.59 1.8 20 0.0027 0.61 Conclusion: Therefore our device complies with FCC’s RF radiation exposure limits for general population without SAR evaluation with at least 20cm separation from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Template : March 5 th , 2024 Reproduction of this document is only authorized in its complete form. Any partial reproduction or any insertion of results in an accompanying text with a view to their distribution must receive prior and formal agreement from LCIE. This document results from tests carried out on a specimen, sample or test piece. It does not prejudge the conformity of all the products manufactured to the object tested. Unless otherwise indicated or rule specified by the test method, the decision of conformity does not take into account measurement uncertainty. It in no way prejudges a certification decision. The accreditation of the COFRAC Testing Section attests to the technical competence of the laboratories for the tests covered by the accreditation only. If certain tests mentioned in this report were carried out outside the framework of COFRAC accreditation, they are identified by the symbol . LCIE Laboratoire Central des Industries Electriques Une société Bureau Veritas Z.I Centr'alp 170, Rue de Chatagnon 38430 Moirans FRANCE Tél. + 33 4 76 07 36 36 [email protected] www.lcie.fr SAS au capital de 15 745 984€ / RCS Nanterre B 408 363 174 / N° TVA intracommunautaire FR01 408 363 174 / N°SIRET 408 363 174 00017 Accreditation N°1-1633 Scope available on www.cofrac.fr TEST REPORT N°: 20585321-795321-A (FILE #7369122) VERSION: 01 Subject Radio spectrum tests according to the standards: FCC CFR 47 Part 15.247 & ANSI C63.10 RSS-247 & RSS-Gen Issued to IJINUS 25 ZA de Kervidanou 3 29300 – MELLAC FRANCE Apparatus under test Product DATALOGGER & PRESSURE RECORDER Trade mark IJINUS Manufacturer IJINUS Model under test H0102 Serial number IJH0102-0000 0122 FCCID SE6H001 IC 10983-H001 Conclusion See Test Program chapter Test date April 15, 2024 to April 17, 2024 Test location LCIE Grenoble FCC Test site FR0008 - 918017 (MOI) ISED Test site 6500A (MOI) Sample receipt date April 10, 2024 Composition of document 51 pages Document issued on May 27, 2024 Written by : Approved by : Majid MOURZAGH Anthony MERLIN Tests operator Technical manager TEST REPORT N°20585321-795321-A Version : 01 Page 2/51 PUBLICATION HISTORY Version Date Author Modification 01 May 27, 2024 Majid MOURZAGH Creation of the document Each new edition of this test report replaces and cancels the previous edition. The control of the old editions of report is under responsibility of client. TEST REPORT N°20585321-795321-A Version : 01 Page 3/51 SUMMARY 1. TEST PROGRAM ............................................................................................................................. 4 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) .............................. 5 3. DUTY CYCLE ................................................................................................................................. 10 4. OCCUPIED BANDWIDTH ............................................................................................................... 13 5. 6DB BANDWIDTH .......................................................................................................................... 16 6. MAXIMUM CONDUCTED OUTPUT POWER ................................................................................. 19 7. POWER SPECTRAL DENSITY ...................................................................................................... 22 8. UNWANTED EMISSIONS IN NON-RESTRICTED FREQUENCY BANDS ..................................... 26 9. UNWANTED EMISSIONS IN RESTRICTED FREQUENCY BANDS .............................................. 30 10. UNCERTAINTIES CHART .............................................................................................................. 51 TEST REPORT N°20585321-795321-A Version : 01 Page 4/51 1. TEST PROGRAM References ➢ 47 CFR Part 15.247 (2023) ➢ RSS 247 Issue 3 ➢ RSS Gen Issue 5 ➢ KDB 558074 D01 DTS Meas Guidance v05r02 ➢ KDB 662911 D01 Multiple Transmitter Output v02r01 ➢ ANSI C63.10 (2013) Radio requirement: Clause - Test Description Test result - Comments Occupied Bandwidth ISED PASS 6dB Bandwidth FCC & ISED PASS Duty Cycle FCC & ISED PASS Maximum Conducted Output Power FCC & ISED PASS Power Spectral Density FCC & ISED PASS Unwanted Emissions in Non-Restricted Frequency Bands FCC & ISED PASS Unwanted Emissions in Restricted Frequency Bands FCC & ISED PASS Receiver Radiated Emissions ISED PASS(2) This table is a summary of test report, see conclusion of each clause of this test report for detail. (1) Limited program (2) Testing covered the receive mode, and receiver spurious emissions are considered to be the same as transmitter. PASS: EUT complies with standard’s requirement FAIL: EUT does not comply with standard’s requirement NA: Not Applicable NP: Test Not Performed TEST REPORT N°20585321-795321-A Version : 01 Page 5/51 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) 2.1. INFORMATIONS -Tests are performed on the most complete product IJINUS, SN: IJH0102-0000 0122. See Table below for difference between products. We, IJINUS, declare that all the following products (PMNs) are based on the same electronics card and same mechanical basis. The products are electrically based on a mother board shared by all the A0102 products. This mother board manages the global control, the memory, and the ISM radio short range communication. Depending on the needed functionalities different peripherals can be added to the common basis. Below are listed the specific features of all the PMNs: PMN Features BLUEV4-LP Data logger with internal pressure sensor BLUEV4 Data logger without internal pressure sensor TEST REPORT N°20585321-795321-A Version : 01 Page 6/51 2.2. HARDWARE IDENTIFICATION (EUT AND AUXILIARIES): Equipment under test (EUT): Model under test: H0102 Serial Number: IJH0102-0000 0122 Dimensions: 116cm x 52cm x 220cm (Length x Width x Height) Type: Table-Top Power supply: Name Type Rating Reference / Sn Comments Supply1 Battery 3.6V FANSO ER34615H-2+10…
Text truncated - open the document above for the full version.
LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 1/2 CONDUCTED AND RADIATED MEASUREMENT PHOTO FCCID: SE6H001 1.1 Radiated emissions Photo of Unwanted Emissions in Restricted Frequency Bands on FAR LCIE SUD EST Laboratoire de Moirans Z.I. Centr’Alp 170, Rue de Chatagnon 38430 MOIRANS - FRANCE Page 2/2
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 915 MHz - 915 MHz | 9.10 mW |

ACCESS POINT 915MHz (US) / LAN
Equipment Class
DTS - Digital Transmission System
TEMPERATURE DATA LOGGER LT2
Equipment Class
DTS - Digital Transmission System
TEMPERATURE DATA LOGGER LT7
Equipment Class
DTS - Digital Transmission System
Access Point
Equipment Class
DTS - Digital Transmission System
Wiji Wireless sensor/logger
Equipment Class
DTS - Digital Transmission System