About this Manual P/N: 01.54.456527 MPN: 01.54.456527011 Release Date: January 2015 © Copyright EDAN INSTRUMENTS, INC. 2014-2015. All rights reserved. Statement This manual will help you understand the operation and maintenance of the product better. It is reminded that the product shall be used strictly complying with this manual. User’s operation failing to comply with this manual may result in malfunction or accident for which EDAN INSTRUMENTS, INC. (hereinafter called EDAN) can not be held liable. EDAN owns the copyrights of this manual. Without prior written consent of EDAN, any materials contained in this manual shall not be photocopied, reproduced or translated into other languages. Materials protected by the copyright law, including but not limited to confidential information such as technical information and patent information are contained in this manual, the user shall not disclose such information to any irrelevant third party. The user shall understand that nothing in this manual grants him, expressly or implicitly, any right or license to use any of the intellectual properties of EDAN. EDAN holds the rights to modify, update, and ultimately explain this manual. Responsibility of the Manufacturer EDAN only considers itself responsible for any effect on safety, reliability and performance of the equipment if: Assembly operations, extensions, re-adjustments, modifications or repairs are carried out by persons authorized by EDAN, and The electrical installation of the relevant room complies with national standards, and The instrument is used in accordance with the instructions for use. Upon request, EDAN may provide, with compensation, necessary circuit diagrams, and other information to help qualified technician to maintain and repair some parts, which EDAN may I define as user serviceable. Terms Used in this Manual This guide is designed to give key concepts on safety precautions. WARNING A WARNING label advises against certain actions or situations that could result in personal injury or death. CAUTION A CAUTION label advises against actions or situations that could damage equipment, produce inaccurate data, or invalidate a procedure. NOTE A NOTE provides useful information regarding a function or a procedure. II Table of Contents Chapter 1 Intended Use and Safety Guidance ............................................................................ 1 1.1 Intended Use/Indications for Use ........................................................................................ 1 1.2 Safety Guidance .................................................................................................................. 1 1.3 Explanation of Symbols on the Telemetry transmitter ........................................................ 6 Chapter 2 Overview ....................................................................................................................... 8 2.1 System Introduction ............................................................................................................ 8 2.2 Display Screen of Telemetry Transmitter............................................................................ 8 2.2.1 Default Interface........................................................................................................ 8 2.2.2 Main Interface ........................................................................................................... 9 2.2.3 Setting Interface ...................................................................................................... 12 2.3 Appearance of Telemetry Transmitter ............................................................................... 12 2.3.1 Front View ............................................................................................................... 12 2.3.2 Rear View ................................................................................................................ 14 2.3.3 Left Side View ......................................................................................................... 15 2.3.4 Right Side View ...................................................................................................... 15 2.3.5 Top View ................................................................................................................. 16 2.3.6 Bottom View ........................................................................................................... 16 2.4 Configuration .................................................................................................................... 16 2.5 Display Screens of the MFM-CMS................................................................................... 17 2.5.1 Overview ................................................................................................................. 17 2.5.2 Main Screen ............................................................................................................ 17 2.5.3 Auxiliary Screen ...................................................................................................... 20 2.5.4 Large Font Display .................................................................................................. 22 2.5.5 Layout of Patient Sectors ........................................................................................ 23 Chapter 3 Installation of Telemetry Monitoring System .......................................................... 24 3.1 Initial Inspection................................................................................................................ 24 3.2 Installation Environment ................................................................................................... 24 3.3 Power Supply Requirement............................................................................................... 24 3.4 Wireless Network ....................................................................................…
Text truncated - open the document above for the full version.
2015-03-27 TUV SUD BABT TCB Octagon House, Segensworth Road, Fareham, Hampshire, PO15 5RL Confidentiality Request FCC ID: SMQIT20EDAN Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, (EDAN INSTRUMENTS,INC.) hereby requests permanent confidential treatment of information accompanying this application as outlined below: << List of Exhibits either by name or type e.g. “Schematics” [exhibit type] or “Design Drawings” [description of data which must be uploaded ] >> [Common exhibits for which confidentiality is requested are: Schematics Block Diagrams Theory of Operation] (EDAN INSTRUMENTS,INC.) also hereby requests short-term confidential treatment of information accompanying this application as outlined below for a period of (180) days: << List of Exhibits either by name or type e.g. “Internal Photos” [exhibit type]>> [Common exhibits for which short-term confidentiality is requested are: Internal Photos External Photos User Manual Test Set-up Photographs The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Company Officer: Xiahuanhuan (signed by FCC listed Grantee contact) Telephone Number: 0755-26682547 Email: [email protected]
APPENDIX B – External of EUT Page 1 of 4 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052 APPENDIX B – External of EUT Page 2 of 4 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052 APPENDIX B – External of EUT Page 3 of 4 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052 APPENDIX B – External of EUT Page 4 of 4 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052
2 6 . 4 6 深圳市理邦精密仪器股份有限公司 43.06 2.00 iT20后壳(英文、已丝印) PC+ABS(SABIC LEXAN C2950) 1.1 FCC ID:SMQIT20EDAN FCC ID:SMQIT20EDAN
APPENDIX C – Internal of EUT Page 1 of 5 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052 WIFI Antenna APPENDIX C – Internal of EUT Page 2 of 5 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052 APPENDIX C – Internal of EUT Page 3 of 5 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052 APPENDIX C – Internal of EUT Page 4 of 5 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052 Antenna Connector APPENDIX C – Internal of EUT Page 5 of 5 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052
12 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China RF exposure Estimation for iT20 1. Introduction EUT is a Telemetry Transmitter, which contain WIFI function inside. 2. Limit and Guidelines on Exposure to Electromagnetic Fields According to§15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. According to KDB 447498 D01 Mobile Portable RF Exposure v05r02, no SAR required if power is lower than the flowing threshold: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where • f(GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation25 • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. 3. Calculation method [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 Conducted Power + tune up tolerance = 9.33mW (9.7dBm) Distance = 5 mm f = 2.4 GHz TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China [9.33/5] * SQRT(2.412) =2.90 2.90 ≤ 3.0 Therefore, excluded from SAR testing. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Reviewed by: Prepared By: John Zhi/ EMC Project Manager Alan Xiong/EMC Project Engineer Date: 2015-04-13 Date: 2015-04-13
Report Number: 68.960.15.026.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 37 FCC/IC - TEST REPORT Report Number : 68.960.15.026.01 Date of Issue: March 27, 2015 Model : iT20 Product Type : Telemetry Transmitter Applicant : EDAN INSTRUMENTS,INC. Address : 3/F-B, Nanshan Medical Equipment Park, Nanhai Rd 1019#, Shekou, Nanshan Shenzhen, 518067 P.R. CHINA Production Facility : EDAN INSTRUMENTS,INC. Address : 3/F-B, Nanshan Medical Equipment Park, Nanhai Rd 1019#, Shekou, Nanshan Shenzhen, 518067 P.R. CHINA Test Result : Positive Negative Total pages including Appendices : 39 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval Report Number: 68.960.15.026.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 37 1 Table of Contents 1 Table of Contents .................................................................................................................. 2 2 Details about the Test Laboratory ......................................................................................... 3 3 Description of the Equipment Under Test .............................................................................. 4 4 Summary of Test Standards .................................................................................................. 5 5 Summary of Test Results ...................................................................................................... 6 6 General Remarks .................................................................................................................. 7 7 Test Setups ........................................................................................................................... 8 8 Systems test configuration .................................................................................................... 9 9 Technical Requirement ....................................................................................................... 10 9.1 Conducted peak output power ...................................................................................... 10 9.2 6dB bandwidth .............................................................................................................. 12 9.3 Power spectral density .................................................................................................. 18 9.4 Spurious RF conducted emissions ............................................................................... 19 9.5 Band edge testing ......................................................................................................... 29 9.6 Spurious radiated emissions for transmitter and receiver ............................................. 33 10 Test Equipment List ............................................................................................................ 36 11 System Measurement Uncertainty ...................................................................................... 37 Report Number: 68.960.15.026.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 37 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China FCC Registration Number: 502708 Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Report Number: 68.960.15.026.01 EMC_SZ_FR_21.00 FCC Release 2014-03-20 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 37 3 Description of the Equipment Under Test Product: Telemetry Transmitter Model no.: iT20 FCC ID: SMQIT20EDAN Brand Name: EDAN Options and accessories: NIL Rating: DC 3.0V By 2*AA Batteries RF Transmission Frequency: 2412-2462MHz No. of Operated Channel: 11 Modulation: DSSS, OFDM Antenna Type: Internal Antenna Gain: 3.0dBi Description of the EUT: The Equipment Under Test (EUT) is …
Text truncated - open the document above for the full version.
APPENDIX A – Photos of Test Setup Page 1 of 1 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Shenzhen, China, 518052 Radio Emission (30MHz-1GHz) Radio Emission (Above 1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 9.00 mW |

Bluetooth module
Equipment Class
DTS - Digital Transmission System
Telemetry Monitor
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterShenzhen CTL Testing Technology Co., Ltd.
Equipment Class
NII - Unlicensed National Information Infrastructure TX
WIFI module
Equipment Class
DTS - Digital Transmission System
Nano Series Diagnostic Ultrasound Systen
Equipment Class
NII - Unlicensed National Information Infrastructure TX