FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Woodstream Corporation/
  3. SNA-M1

SNA-M1WiFi Mousetrap

Woodstream Corporation
WiFi Mousetrap - FCC ID SNA-M1 - Woodstream Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 10, 2020
Application Purpose
Original Equipment
Date of Application
May 06, 2020
Equipment Note
WiFi Mousetrap
Frequency Range
2412.00000000 - 2462.00000000
Company
Woodstream Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

69 N. Locust Street Lititz, PA 17543 (800) 800-1819 www.woodstreamcorp.com 5/11/2020 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Permanent Confidentiality To whom it may concern: In accordance with 47CFR Section 0.457 and Section 0.459 pertaining to confidential material, we hereby request to hold permanently confidential all information contained within the below identified exhibits/document categories submitted pursuant to radio equipment certification requirements for FCC ID: SNA-M1 1. Block Diagram 2. Schematics 3. Parts List / Tune-Up Procedure 4. Operational Description The above material contains trade secrets and proprietary information as specified by 47CFR 0.457(d) and technical data, which would customarily be guarded from competitors. The public disclosure of this information might be harmful to our company and provide unjustified benefits to our competitors. Sincerely, Dwayne Arrighy Electronic Product Compliance Engineer Woodstream Corporation

External Photos

F2P21756C Page 1 of 3 Jan. 23, 2020 PHOTOGRAPHS: EXTERNAL Applicant - Woodstream Corporation - Model M1 Order Number: F2P21756C Client: Woodstream Corporation Model: M1 F2P21756C Page 2 of 3 Jan. 23, 2020 Order Number: F2P21756C Client: Woodstream Corporation Model: M1 F2P21756C Page 3 of 3 Jan. 23, 2020

RF Exposure Info

042216 Report Number: F2P21756C-05E Page 1 of 8 Issue Date: Apr. 29, 2020 F2 Labs 16740 Peters Road Middlefield, Ohio 44062 United States of America www.f2labs.com CERTIFICATION TEST REPORT Manufacturer: Woodstream Corporation 69 North Locust Street Lititz, Pennsylvania 17543 USA Applicant: Same As Above Product Name: Victor WiFi Mouse Trap Product Description: WiFi enabled electronic mouse trap which detects a rodent and then shocks it in order to kill it. The trap can then connect to WiFi in order to send notifications to the user's phone via an app. Runs on 4 AA batteries. Operating Voltage/Frequency: Battery-Operated (4 AA Batteries) Model: M1 FCC ID: SNA-M1 Testing Commenced: Oct. 29, 2019 Testing Ended: Jan. 23, 2020 Test Results: In Compliance, with Modifications The EUT complies with the EMC requirements when manufactured identically as the unit tested in this report, including any required modifications. Any changes to the design or build of this unit subsequent to this testing may deem it non-compliant. Standards: • KDB447498 Order Number: F2P21756C Client: Woodstream Corporation Model: M1 042216 Report Number: F2P21756C-05E Page 2 of 8 Issue Date: Apr. 29, 2020 Evaluation Conducted by: Julius Chiller, EMC/Wireless Engineer Report Reviewed by: Ken Littell, Director of EMC & Wireless Operations F2 Labs F2 Labs F2 Labs 26501 Ridge Road 16740 Peters Road 8583 Zionsville Road Damascus, MD 20872 Middlefield, OH 44062 Indianapolis, IN 46268 Ph 301.253.4500 Ph 440.632.5541 Ph 317.610.0611 This test report may be reproduced in full; partial reproduction only may be made with the written consent of F2 Labs. The results in this report apply only to the equipment tested. Order Number: F2P21756C Client: Woodstream Corporation Model: M1 042216 Report Number: F2P21756C-05E Page 3 of 8 Issue Date: Apr. 29, 2020 TABLE OF CONTENTS Section Title Page 1 ADMINISTRATIVE INFORMATION 4 2 SUMMARY OF TEST RESULTS/MODIFICATIONS 5 3 ENGINEERING STATEMENT 6 4 EUT INFORMATION AND DATA 7 5 RF EXPOSURE FOR DEVICE >20cm FROM HUMAN 8 Order Number: F2P21756C Client: Woodstream Corporation Model: M1 042216 Report Number: F2P21756C-05E Page 4 of 8 Issue Date: Apr. 29, 2020 1 ADMINISTRATIVE INFORMATION 1.1 Measurement Location: F2 Labs in Middlefield, Ohio. Site description and attenuation data are on file with the FCC's Sampling and Measurement Branch at the FCC Laboratory in Columbia, MD. 1.2 Measurement Procedure: All measurements were performed according to KDB558074. 1.4 Document History Document Number Description Issue Date Approved By F2P21756C-05E First Issue Apr. 29, 2020 K. Littell Order Number: F2P21756C Client: Woodstream Corporation Model: M1 042216 Report Number: F2P21756C-05E Page 5 of 8 Issue Date: Apr. 29, 2020 2 SUMMARY OF TEST RESULTS Test Name Standard(s) Results RF Exposure for Device >20cm from Human KDB447498 Complies Modifications Made to the Equipment None Order Number: F2P21756C Client: Woodstream Corporation Model: M1 042216 Report Number: F2P21756C-05E Page 6 of 8 Issue Date: Apr. 29, 2020 3 ENGINEERING STATEMENT This report has been prepared on behalf of Woodstream Corporation to provide documentation for the testing described herein. This equipment has been tested and found to comply with KDB447498. The test results found in this test report relate only to the item(s) tested. Order Number: F2P21756C Client: Woodstream Corporation Model: M1 042216 Report Number: F2P21756C-05E Page 7 of 8 Issue Date: Apr. 29, 2020 4 EUT INFORMATION AND DATA 4.1 Equipment Under Test: Product: Victor WiFi Mouse Trap Model: M1 Serial No.: None Specified FCC ID: SNA-M1 4.2 Trade Name: Woodstream Corporation 4.3 Power Supply: Battery-Operated 4.4 Applicable Rules: • KDB447498 4.5 Equipment Category: Radio Transmitter-DTS 4.6 Antenna: Integral, 1.443dBi Gain 4.7 Accessories: (4) Procell AA Batteries 4.8 Test Item Condition: The equipment to be tested was received in good condition. Order Number: F2P21756C Client: Woodstream Corporation Model: M1 042216 Report Number: F2P21756C-05E Page 8 of 8 Issue Date: Apr. 29, 2020 5. RF EXPOSURE FOR DEVICE >20cm FROM HUMAN 5.1 Requirements: Distance used is 20cm Limit: 1mW/cm 2 Formula used for result: E.I.R.P. 4 π R 2 Results: E.I.R.P. = 64.9mW 64.9mW at the 2437 MHz Mid Channel which is the highest. 64.9mW = 64.9mW = 0.013mW/cm2 4 π R 2 5026.55

Test Report

051816 Report Number: F2P21756C-01E Page 1 of 106 Issue Date: Jan. 23, 2020 F2 Labs 16740 Peters Road Middlefield, Ohio 44062 United States of America www.f2labs.com CERTIFICATION TEST REPORT Manufacturer: Woodstream Corporation 69 North Locust Street Lititz, Pennsylvania 17543 USA Applicant: Same As Above Product Name: Victor WiFi Mouse Trap Product Description: WiFi enabled electronic mouse trap which detects a rodent and then shocks it in order to kill it. The trap can then connect to WiFi in order to send notifications to the user's phone via an app. Runs on 4 AA batteries. Operating Voltage/Frequency: Battery-Operated (4 AA Batteries) Model: M1 FCC ID: SNA-M1 Testing Commenced: Oct. 29, 2019 Testing Ended: Jan. 23, 2020 Summary of Test Results: In Compliance, with Modifications The EUT complies with the EMC requirements when manufactured identically as the unit tested in this report, including any required modifications and/or manufacturer’s statement. Any changes to the design or build of this unit subsequent to this testing may deem it non-compliant. Standards: • FCC Part 15 Subpart C, Section 15.247 • FCC Part 15.31(e) • ANSI C63.10:2013 Order Number: F2P21756C Applicant: Woodstream Corporation Model: M1 051816 Report Number: F2P21756C-01E Page 2 of 106 Issue Date: Jan. 23, 2020 Evaluation Conducted by: Julius Chiller, EMC/Wireless Engineer Report Reviewed by: Ken Littell, Director of EMC & Wireless Operations F2 Labs F2 Labs F2 Labs 26501 Ridge Road 16740 Peters Road 8583 Zionsville Road Damascus, MD 20872 Middlefield, OH 44062 Indianapolis, IN 46268 Ph 301.253.4500 Ph 440.632.5541 Ph 317.610.0611 This test report may be reproduced in full; partial reproduction only may be made with the written consent of F2 Labs. The results in this report apply only to the equipment tested. Order Number: F2P21756C Applicant: Woodstream Corporation Model: M1 051816 Report Number: F2P21756C-01E Page 3 of 106 Issue Date: Jan. 23, 2020 TABLE OF CONTENTS Section Title Page 1 ADMINISTRATIVE INFORMATION 4 2 SUMMARY OF TEST RESULTS/MODIFICATIONS 5 3 TABLE OF MEASURED RESULTS 6 4 ENGINEERING STATEMENT 7 5 EUT INFORMATION AND DATA 8 6 LIST OF MEASUREMENT INSTRUMENTATION 9 7 OCCUPIED BANDWIDTH 10 8 CONDUCTED OUTPUT POWER 20 9 CONDUCTED SPURIOUS EMISSIONS 30 10 RADIATED SPURIOUS EMISSIONS 79 11 PEAK POWER SPECTRAL DENSITY (PSD) 94 12 PHOTOGRAPHS 104 Order Number: F2P21756C Applicant: Woodstream Corporation Model: M1 051816 Report Number: F2P21756C-01E Page 4 of 106 Issue Date: Jan. 23, 2020 1 ADMINISTRATIVE INFORMATION 1.1 Measurement Location: F2 Labs in Middlefield, Ohio. Site description and attenuation data are on file with the FCC's Sampling and Measurement Branch at the FCC Laboratory in Columbia, MD. 1.2 Measurement Procedure: All measurements were performed according to the 2013 version of ANSI C63.10 and recommended FCC procedure of measurement of DTS operating under Section 15.247 and in KDB558074. A list of the measurement equipment can be found in Section 6. 1.3 Uncertainty Budget: The uncertainty in EMC measurements arises from several factors which affect the results, some associated with environmental conditions in the measurement room, the test equipment being used and the measurement techniques adopted. The measurement uncertainty budgets detailed below are calculated from the test and calibration data, and are expressed with a 95% confidence factor. Note: Only measurements listed below which relate to tests included in this Test Report are applicable to it. This Uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. 1.4 Document History Document Number Description Issue Date Approved By F2P22041A-01E First Issue Jan. 23, 2020 K. Littell Measurement Range Expanded Uncertainty Combined Uncertainly Radiated Emissions <1 GHz @ 3m ±5.07dB ±2.54 Radiated Emissions <1 GHz @ 10m ±5.09dB ±2.55 Radiated Emissions 1 GHz to 2.7 GHz ±3.62dB ±1.81 Radiated Emissions 2.7 GHz to 18 GHz ±3.10dB ±1.55 AC Power Line Conducted Emissions, 150kHz to 30 MHz ±2.76dB ±1.38 Order Number: F2P21756C Applicant: Woodstream Corporation Model: M1 051816 Report Number: F2P21756C-01E Page 5 of 106 Issue Date: Jan. 23, 2020 2 SUMMARY OF TEST RESULTS Test Name Standard(s) Results Occupied Bandwidth CFR 47 Part 15.247(a)(2) / KDB558074 Complies Conducted Output Power CFR 47 Part 15.247(b)(3) / KDB558074 Complies Voltage Variations CFR 47 Part 15.31(e) Complies* Conducted Spurious Emissions CFR 47 Part 15.247(d) / Part 15.207 / KDB558074 Complies Radiated Spurious Emission with 1.443dBi Integral Antenna CFR 47 Part 15.247(d) / Part 15.209 / KDB558074 Complies Peak Power Spectral Density CFR 47 Part 15.247(e) / KDB558074 Complies *Requirements of 15.31 were met by using new batteries. Modifications Made to the Equipment Power attenuation was adjusted to -6dB. Order Number: F2P21756C Applicant: Woodstream Corporation Model: M1 051816 Report Number: F2P21756C-01E Page 6 of 106 Issue Date: Jan. 23, 2020 3 TABLE OF MEASURED RESULTS Test Low Channel 2.412 GHz Mid Channel 2.437 GHz High Channel 2.462 GHz Conducted Output Power 11b CCK 15.26dBm 15.53dBm 15.24dBm 11g 54 Mbps OFDM 16.18dBm 16.68dBm 16.22dBm 11n MCS7 14.62dBm 14.84dBm 14.65dBm Conducted Output Power Limit 1 Watt, 30dBm 1 Watt, 30dBm 1 Watt, 30dBm Peak Power Spectral Density 11b CCK -12.39dBm -11.52dBm -11.96dBm 11g 54 Mbps OFDM -16.48dBm -15.70dBm -16.44dBm 11n MCS7 -12.48dBm -12.01dBm -12.61dBm Peak Power Spectral Density Limit 8dBm 8dBm 8dBm -6dB Occupied Bandwidth 11b CCK 8.079 MHz 8.066 MHz 8.066 MHz 11g 54 Mbps OFDM 16.466 MHz 16.464 MHz 16.457 MHz 11n MCS7 17.561 MHz 17.543 MHz 17.55 MHz -6dB Occupied Bandwidth Limit ≥ 500KHz ≥ 500KHz ≥ 500KHz Order Number: F2P21756C Applicant: Woodstream Corporation Model: M1 051816 Report Number: F2P21756C-01E Page 7 of 106 Issue Date: Jan. 23, 2020 4 ENGINEERING STATEMENT This report has been prepared on behalf of Woodstream Corporation to provide docu…

Text truncated - open the document above for the full version.

Test Setup Photos

F2P21756C Page 1 of 3 Jan. 23, 2020 PHOTOGRAPHS: TEST SETUP Applicant - Woodstream Corporation - Model M1 Conducted Output Power, Peak Power Spectral Density, Occupied Bandwidth, and Conducted Spurious Emissions Order Number: F2P21756C Client: Woodstream Corporation Model: M1 F2P21756C Page 2 of 3 Jan. 23, 2020 Radiated Spurious Emissions, Less than 30 MHz Radiated Spurious Emissions, 30 MHz to 1000 MHz Order Number: F2P21756C Client: Woodstream Corporation Model: M1 F2P21756C Page 3 of 3 Jan. 23, 2020 Radiated Spurious Emissions 1 GHz to 18 GHz Radiated Spurious Emissions 18 GHz to 26 GHz

Contact Information

Applicant

Dwayne Arrighy
[email protected]7177404600Fax: (717) 626-1912

Test Firm

F2 LabsWendy Fuster
[email protected]301-253-4500Fax: 301-253-5179

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz47.00 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Woodstream Corporation

SNA-V430B

V430B Rodent Snap Trap

Apr 14, 2024

Equipment Class

DTS - Digital Transmission System
Bait Box Rodent Trap with LoRa Radio - FCC ID SNA-V440 - Woodstream Corporation
SNA-V440

Bait Box Rodent Trap with LoRa Radio

Dec 07, 2022

Equipment Class

DTS - Digital Transmission System
WiFi Rat Trap - FCC ID SNA-M2 - Woodstream Corporation
SNA-M2

WiFi Rat Trap

May 10, 2020

Equipment Class

DTS - Digital Transmission System
LoRa Radio Connected Rodent Trap - FCC ID SNA-V400MR1 - Woodstream Corporation
SNA-V400MR1

LoRa Radio Connected Rodent Trap

Mar 11, 2020

Equipment Class

DTS - Digital Transmission System
Wireless Electronic Rat Trap - FCC ID SNA-M240RF - Woodstream Corporation
SNA-M240RF

Wireless Electronic Rat Trap

Nov 05, 2012

Equipment Class

DTS - Digital Transmission System