FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Innovative Wireless Technologies, Inc./
  3. SP8-IXU1-ASY1168

SP8-IXU1-ASY1168ISM 902-928 MHz Transceiver for Mesh Networking

Innovative Wireless Technologies, Inc.
ISM 902-928 MHz Transceiver for Mesh Networking - FCC ID SP8-IXU1-ASY1168 - Innovative Wireless Technologies, Inc.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Oct 15, 2006
Application Purpose
Original Equipment
Date of Application
Oct 11, 2006
Equipment Note
ISM 902-928 MHz Transceiver for Mesh Networking
Frequency Range
903.00000000 - 927.00000000
Company
Innovative Wireless Technologies, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 45 of 52 Appendix I: Manual Please refer to the following pages. © 2006 Copyright Innovative Wireless Technologies P1b mProm™ 900MHz Module USER MANUAL © 2006 Copyright Innovative Wireless Technologies R1 IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Under normal operating conditions, the antenna is designed to maintain a separation distance of 20 cm from all persons. Changes or modifications to this unit not expressly approved by Innovative Wireless Technologies, Inc. could void the user’s authority to operate this equipment. Innovative Wireless Technologies, Inc. 1047 Vista Park Drive, Suite A Forest, Virginia 24551 1-434-316-5230 (United States) www.iwtwireless.com (United States) mProm™, mPros™ and mProv™ are registered in the US Patent & Trademark Office by Innovative Wireless Technologies, Inc. © 2006 Innovative Wireless Technologies, Inc This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. FCC ID: SP8-IXU1-ASY1168 © 2006 Copyright Innovative Wireless Technologies R1 mProm™ 900MHz Mesh Networking Module User Manual Overview IWT’s mProm™ Module is a 900 MHz ISM transceiver module that offers an embedded microprocessor. The mProm module is designed for easy integration into systems needing connectivity or wire replacement. The mProm™ module utilizes the 902- 928MHz ISM band and is FCC certified for most integrated applications. The modules are pre-programmed with IWT’s mProm™ mesh networking protocol including a RTOS and user API supporting customization for a wide range of applications. The mProm™ 900 MHz Module is compatible with IWT’s mProv™ suite of mesh network management, control, and data aggregation tools. Applications: ∑ M2M ∑ Full or Partial Mesh Networking ∑ Wireless Sensor Networks ∑ Two-way Remote Keyless Entry ∑ Automatic Meter Reading Figure 1 – mProm™ Module © 2006 Copyright Innovative Wireless Technologies R1 FCC Statement for OEM Integrators mProm™ Module Use for maintaining RF exposure This device is intended only for OEM integrators under the following conditions: 1. Connection to the mProm™ Module should always be made through the 26 pin header. Connection to the mProm™ Module any other way not expressed in this documentation or approved by Innovative Wireless Technologies, Inc. will void the user’s ability to operate this device under the FCC certification. The header on the mProm ™ Module is a SAMTEC FTMH-113-02-L-DV, and mate connection is CLM-113-02-L-D. 2. The mProm™ Module may not be co-located with any other transmitter or antenna. 3. The mProm™ Module is approved using the FCC “Unlicensed modular transmitter approval” method. Therefore the mProm™ Module must only be used with the originally approved antenna(s). As long as the 3 conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). IMPORTANT NOTE: In the event that these conditions can not be met (for example certain, co- location with another transmitter, or different antenna), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. OEM End Product Labeling The mProm™ module is to be installed in a OEM product without alteration. During installation, do not remove the FCC ID information on the module. The final end product that has integrated the mProm™ Module must be labeled in a visible area with the following: Contains TX FCC ID: SP8-IXU1-ASY1168 IMPORTANT NOTE TO OEM The end user of the OEM’s product, with incorporated mProm™ Module, should NOT be provided any instructions on how to remove or install the mProm™ Module. © 2006 Copyright Innovative Wireless Technologies R1 The mProm™ Module Interface (Getting Started) Voltage must be supplied to the mProm™ Module via pins 19 and 20 on the interface header. The mProm™ Module regulates its voltage on board, but must be supplied a voltage between 3.5-14 Volts. The table below outlines the 26 pin interface to the mProm™ Module. The mechanical diagram that follows indicates where pin-1 starts. Pin # Pin Name Pin Type Description 1 CNVss Digital Input 2 BUSY/UART_CS Digital I/O Pin set to function as UART 3 GDO2_CC1100 Digital I/O 4 3.3V Power (RF/Dig.) 3.3V regulated output voltage 5 CE Digital I/O Chip enable 6 DfromMicro_UART Digital Input Data sent from microprocessor 7 P_SCLK Digital I/O Programming clock 8 DfromPC_UART Digital Input Data sent from computer 9 GND SIGNAL Ground (Digital) / RF Digital ground connection 10 GPIO6 Digital I/O PWM GPIO 11 RESET Digital Input Resets the microprocessor 12 GPIO7 Digital I/O PWM GPIO 13 UART_CLK Digital I/O CLK pin for configurable UART 14 GPIO3 Digital I/O Interruptible GPIO 15 GPIO5 Digital I/O Interruptible GPIO 16 GPIO4 Digital I/O Interruptible GPIO 17 A0 Digital I/O-Analog In A/D converter 18 3.3V Power (RF/Dig.) 3.3V regulated output voltage 19 GND SIGNAL Ground (Digital) / RF Digital ground connection 20 V unreg 3.6V Battery Connection 3.4V-12V battery/power connection (absolute max 14 V) 21 A1 Digital I/O-Analog In A/D converter 2…

Text truncated - open the document above for the full version.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 38 of 52 Appendix B: Agency Authorization Letter Please refer to the following page. IWT Confidential Revision P3 October 8, 2006 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Please be advised that Innovative Wireless Technologies, Inc. authorizes Rhein Tech Laboratories, Inc. to act on our behalf, until otherwise notified, for applications submitted to the Federal Communications Commission and/or American Telecommunications Certification Body, Inc.. We certify that we are not subject to denial of federal benefits, which includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862. Further, no party to the application, as defined in 47 CFR 1.2002(b), is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Sincerely, Gary L. Raulerson, Jr. Engineering Programs Manager, ARI Innovative Wireless Technologies, Inc.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 39 of 52 Appendix C: Confidentiality Request Letter Please refer to the following page. IWT Confidential Revision P3 October 8, 2006 American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: The following information is to be held confidential pursuant of 47 CFR Part 0 §0.459 and Section 552(b)(4) of the Freedom of Information Act, because the information provided contains trade secrets and is proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. ∑ Schematics ∑ Technical Product Description ∑ Block Diagram Sincerely, Gary L. Raulerson, Jr. Engineering Program Manager, ARI Innovative Wireless Technologies, Inc.

Cover Letter(s)

Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 40 of 52 Appendix D: Modular Approval Request Please refer to the following page. IWT Confidential Revision R1 October 8, 2006 Federal Communications Commission To Whom It May Concern: Please be advised that Innovative Wireless Technologies, Inc. is requesting Part 15 Unlicensed Modular approval for its mProm™ 900 MHz Module, FCC ID: SP8-IXU1-ASY1168. The below statements outline Innovative Wireless Technologies’ responses to DA00-1407 concerning Modular approval. 1. The mProm™ 900 MHz Module has shielding placed around the transceiver ASIC and its applicable passive components. 2. The mProm™ 900 MHz Module has buffered modulation/data inputs in the transceiver ASIC and the microcontroller located on the module. All user available external inputs go through the microcontroller before being passed to the transceiver section. 3. The mProm™ 900 MHz Module contains its own power regulatory circuitry. 4. The antenna on the AXON™ Module is permanently attached. The antenna is a chip antenna, P/N 0920AT50A080, from Johanson Technology. 5. The mProm™ 900 MHz Module has been tested by Rhein Tech Laboratories for Part 15 emissions compliance. The module was tested as a stand-alone transmitter complying with §15.247. 6. The mProm™ 900 MHz Module will have its own FCC ID label located on top of the shielding. Because of the module size only the words “FCC ID: SP8-IXU1-ASY1168” can be used on the module label. 7. The users manual for the mProm™ 900 MHz Module outline the proper usage for the module and will be submitted with the application for equipment authorization. 8. The mProm™ 900 MHz Module is a low radiated power device, 10mW, and will not be operated in a manner as described by Table 1 of §1.1307(b)(1) that would expose the public to energy levels in excess of the Commision’s guidelines. Innovative Wireless Technologies, Inc. certifies that the above statements are true to the best of our knowledge. Thank you for your attention to this matter. Sincerely, Gary L. Raulerson, Jr. Engineering Programs Manager Innovative Wireless Technologies, Inc.

Cover Letter(s)

American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 October 12, 2006 RE: Innovative Wireless Technologies, Inc. FCC ID: SP8-IXU1-ASY1168 I have a few comments on this Application. 1.) The RF Exposure exhibit states 20 cm distance mobile. The user’s manual dose not contain the 20cm statement under the “Important Note” header, please revise user manual to include this statement. Response: Please refer to the revised manual exhibit uploaded with this response. Douglas E. Noble Examining Engineer mailto: [email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.

External Photos

Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 50 of 52 Appendix K: External Photographs Photograph 5: Top of PCB Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 51 of 52 Photograph 6: Bottom of PCB with Shield Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 52 of 52 Photograph 7: Bottom of PCB without Shield

ID Label/Location Info

Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 41 of 52 Appendix E: Label and Label Location Please refer to the following page for a sample of the label and location. Microcontroller regulator Microcontroller SideTransceiver Side 1200 1950 2 125 26 Bottom Side 1200 1950 192 320 592 FCC ID LABEL FIXED TO Transceiver Shield FCC ID: SP8-IXU1-ASY1168 FCC ID: SP8-IXU1-ASY1168 FCC ID Label Dimensions 310 500 All Dimensions in mils (1/1000 ") ANT 310 DRAWN BY Gary Raulerson, IWT Inc. DATE 9-Oct-2006 DESCRIPTION mProm label dimensions for FCC certification filing. IWT, Inc. CONFIDENTIAL REVISED 9-Oct-2006

Internal Photos

Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 50 of 52 Appendix K: External Photographs Photograph 5: Top of PCB Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 51 of 52 Photograph 6: Bottom of PCB with Shield Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 52 of 52 Photograph 7: Bottom of PCB without Shield

RF Exposure Info

Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 37 of 52 Appendix A: FCC Part 1.1307, 1.1310, 2.1091, 2.1093; IC RSS-Gen: RF Exposure From FCC 1.1310 Table 1A, the maximum permissible RF exposure for an uncontrolled environment is f/1500 or 0.61 mW/cm 2 . The electric field generated for a 1 mW/cm 2 exposure (S) is calculated as follows: )4/()( 2 dGPS×××=π where: S = Power density P = Transmitter conducted power in watts G = Numeric gain d = distance to radiation center Fundamental Operating Frequency: 903–927 MHz Measured Maximum Output Power: 0.009 Watts (9 mW) Antenna Gain = -0.7 dBi; Numeric Gain = 0.85 S = (9 x 0.85)/(4 x Pi x 20 2 ) = 0.002 mW/cm 2 Under normal operating conditions, the antenna is designed to maintain a separation distance of 20 cm from all persons. The EUT is mobile and fixed. Calculated Power Density Antenna Gain = -0.7 dBi Conducted Power (milli-Watt) = 9 Separation Distance = 20 cm FCC Power Density Limit Calculated Power Density at 20 cm Distance 0.61 mW/cm 2 0.002 mW/cm 2

Test Report

Engineering and Testing for EMC and Safety Compliance 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Tel: 703-689-0368 Fax: 703-689-2056 Certification Application Report FCC Part 15.247 Test Lab: Rhein Tech Laboratories, Inc. Tel: 703-689-0368 360 Herndon Parkway Fax: 703-689-2056 Suite 1400 Herndon, VA 20170 E-Mail: [email protected] Web: http://www.rheintech.com Applicant: Innovative Wireless Technologies, Inc. 1047 Vista Park Drive Phone: 434-316-5230 x14 Suite A Fax: 434-316-5232 Forest, VA 24551 Contact: Gary Raulerson, Jr. Email: [email protected] FCC ID: SP8-IXU1-ASY1168 Test Report Date: July 25, 2006 Platform: N/A RTL Work Order #: 2006098 Model Name/ Model Number: mProm TM 900 MHz Module/ IXU1-ASY1168 RTL Quote #: QRTL06-265 American National Standard Institute: ANSI C63.4-2003: Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz FCC Classification: DSS – Part 15 Spread Spectrum Transmitter FCC Rule Part(s): FCC Rules Part 15.247: Operation within the bands 920-928 MHz, 2400-2483.5 MHz and 5725-5850 MHz Direct Sequence System October 1, 2005 Digital Interface Information Digital Interface was found to be compliant Frequency Range (MHz) Output Power (W) Frequency Tolerance Emission Designator 903–927 0.009 N/A 127KFXD I, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified standard(s) as described in this test report. No modifications were made to the equipment during testing in order to achieve compliance with these standards. Furthermore, there was no deviation from, additions to, or exclusions from, the applicable parts of FCC Part 2, FCC Part 15, FCC 97-114, and ANSI C63.4. Signature: Date: July 25, 2006 Typed/Printed Name: Desmond A. Fraser Position: President This report may not be reproduced, except in full, without the written approval of Rhein Tech Laboratories, Inc. The test results relate only to the item(s) tested. Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 2 of 52 Table of Contents 1 General Information...............................................................................................................................................5 1.1 Scope...........................................................................................................................................................5 1.2 Description of EUT........................................................................................................................................5 1.3 Test Facility..................................................................................................................................................5 1.4 Related Submittal(s)/Grant(s).......................................................................................................................5 1.5 Modifications.................................................................................................................................................5 2 Test Information.....................................................................................................................................................6 2.1 Description of Test Modes............................................................................................................................6 2.2 Exercising the EUT.......................................................................................................................................6 2.3 Test Result Summary...................................................................................................................................6 2.4 Test System Details......................................................................................................................................7 2.5 Configuration of Tested System...................................................................................................................7 3 Peak Output Power - §15.247(b)(2).......................................................................................................................8 3.1 Power Output Test Procedure......................................................................................................................8 3.2 Power Output Test Data...............................................................................................................................8 4 Compliance With the Band Edge – FCC §15.247(d)..............................................................................................9 4.1 Band Edge Test Procedure..........................................................................................................................9 4.2 Band Edge Test Results...............................................................................................................................9 4.2.1 Calculation of Lower Band Edge....................................................................................................................................9 4.2.2 Conducted Lower Band Edge Plots .............................................................................................................................10 4.2.3 Calculation of Upper Band Edge..................................................................................................................................12 4.2.4 Conducted Upper Band Edge Plots .............................................................................................................................12 5 Antenna Conducted Spurious Emissions - §15.247(d).........................................................................................14 5.1 Antenna Conducted Spurious Emissions Test Proced…

Text truncated - open the document above for the full version.

Test Setup Photos

Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 46 of 52 Appendix J: Test Photographs Photograph 1: Radiated Testing – Front View Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 47 of 52 Photograph 2: Radiated Testing – Back View Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 48 of 52 Photograph 3: Conducted Emissions Testing – Front View Rhein Tech Laboratories, Inc. Client: Innovative Wireless Technologies, Inc. 360 Herndon Parkway Model #: IXU1-ASY1168 Suite 1400 Standards: FCC 15.247 FCC ID: SP8-IXU1-ASY1168 Herndon, VA 20170 http://www.rheintech.com Report #: 2006098 Page 49 of 52 Photograph 4: Conducted Emissions Testing – Back View

Contact Information

Applicant

Gary L Raulerson, Jr.(New Products Introduction Manager)
[email protected]4343165230Fax: 4343165232

Technical Contact

Rhein TechRichard McMurray
[email protected]703-689-0368

360 Herndon Parkway Suite 1400 · Herndon, Virginia · United States

Test Firm

Rhein Tech Laboratories, Inc.Rick McMurray
[email protected]703-689-0368Fax: 703-689-2056

Technical Specifications

#Rule PartsFrequency RangePower Output
115C903 MHz - 927 MHz9.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Modular Approval Power Output listed is conducted. Approval is limited to OEM installation only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device.

Other Applications from Innovative Wireless Technologies, Inc.

Portable repeater or router for use in an ad-hoc wireless communications network - FCC ID SP8-FAP4215-050 - Innovative Wireless Technologies, Inc.
SP8-FAP4215-050

Portable repeater or router for use in an ad-hoc wireless communications network

Jan 27, 2013

Equipment Class

DTS - Digital Transmission System
Battery powered radio used in a mesh network of unattended sensors - FCC ID SP8-SBB0100-010-1 - Innovative Wireless Technologies, Inc.
SP8-SBB0100-010-1

Battery powered radio used in a mesh network of unattended sensors

Dec 13, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
903-927MHz Transmit Becon for Tracking System - FCC ID SP8-FAP5015-050 - Innovative Wireless Technologies, Inc.
SP8-FAP5015-050

903-927MHz Transmit Becon for Tracking System

Dec 22, 2011

Equipment Class

DTS - Digital Transmission System
Handheld mesh radio for underground/hazardous environments - FCC ID SP8-FAP6210001 - Innovative Wireless Technologies, Inc.
SP8-FAP6210001

Handheld mesh radio for underground/hazardous environments

May 08, 2011

Equipment Class

DTS - Digital Transmission System
802.15.4 Transceiver - FCC ID SP8-IWTBB1142 - Innovative Wireless Technologies, Inc.
SP8-IWTBB1142

802.15.4 Transceiver

Mar 05, 2005

Equipment Class

DTS - Digital Transmission System