FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. RAE Systems, Inc/
  3. SU3PGM6810

SU3PGM6810ModRAE

RAE Systems, Inc
ModRAE - FCC ID SU3PGM6810 - RAE Systems, Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 17, 2026
Application Purpose
Original Equipment
Equipment Note
ModRAE
Frequency Range
2402.00000000 - 2480.00000000
Company
RAE Systems, Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 | Page USER MANUAL Modular Portable Multi-Gas Detector with Internal Pump 2 | Page Contents Ch 1. Introduction ........................................................................................................................................................ 5 1.1. Product Registration ........................................................................................................................................... 5 1.1.1. Standards and Certifications ........................................................................................................................ 5 1.1.2. IMPORTANT! BUMP TEST THE MONITOR BEFORE EACH DAY’S USE ................................................................. 7 1.1.3. Special Notes .............................................................................................................................................. 7 Ch 2. General Information ............................................................................................................................................ 7 2.1. Key Features ...................................................................................................................................................... 8 2.2. Physical Description ........................................................................................................................................... 8 Ch 3. Charging the device ............................................................................................................................................. 8 3.1. The Battery Pack ................................................................................................................................................ 8 3.2. Charging Mode Selection .................................................................................................................................... 9 3.3. Normal Charging Mode ....................................................................................................................................... 9 3.4. Green Charging Mode ....................................................................................................................................... 10 3.5. Measuring Charging Mode ................................................................................................................................ 10 3.6. Real Time Clock Battery .................................................................................................................................... 10 3.7. Data Protection while power is off. .................................................................................................................... 11 Ch 4. Basic Operations ............................................................................................................................................... 12 4.1. Turning the instrument ON ................................................................................................................................ 12 4.2. Turning the instrument OFF ............................................................................................................................... 12 4.3. Alarm Check .................................................................................................................................................... 12 4.4. IntelliFlash™ and Comfort Beep ......................................................................................................................... 13 4.5. User ID and Login ............................................................................................................................................. 13 4.5.1. Guest Access ............................................................................................................................................ 13 4.5.2. Login Requirement ..................................................................................................................................... 14 4.5.3. Login Methods ........................................................................................................................................... 14 Ch 5. User Interface ................................................................................................................................................... 15 5.1. Status Bar ........................................................................................................................................................ 15 5.1.1. Battery Status Icons ................................................................................................................................... 15 5.1.2. Data logging Status Icons ........................................................................................................................... 16 5.1.3. Pump Status Icons ..................................................................................................................................... 16 5.1.4. Man-Down Alarm Icons .............................................................................................................................. 16 5.1.5. Panic Alarm or SOS alarm Icons. ................................................................................................................. 16 5.1.6. BLE Status Icons ........................................................................................................................................ 16 5.1.7. Wireless Module Status Icons ..................................................................................................................... 17 5.1.8. GNSS Status Icons ..................................................................................................................................... 17 5.1.9. Other Status Icons ..................................................................................................................................... 17 3 | Page 5…

Text truncated - open the document above for the full version.

Attestation Statements

092723-17 rev 10 Certification Application Attestation Statements D ate: June 10, 2026 A merican Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 T o Whom It May Concern: S tatement for 47 CFR section 2.911(d)(5)(i) RAE Systems, Inc certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. I f the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. Additional Explanation: <N/A> S tatement for 47 CFR section 2.911(d)(5)(ii) RAE Systems, Inc (“the applicant”) certifies that, as of the date of the filing of this application, the applicant ☐ - is /  - is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates – see KDB 986446 Question 5) as an entity producing “covered” equipment. T he applicant also certifies that the device does not have cybersecurity and/or anti-virus software produced by Kaspersky Lab, Inc or any of its successors and assignees identified on the covered list installed on the device, nor will it be installed by the applicant at any time after certification. T hank you, By : __________________________ Saxinger Bonnie ___________ (Signature 2 ) (Print name) T itle: Sr Advanced Regulatory Engineer C ompany: RAE System, Inc Telephone: +18479554040 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . 2 - Letters must be placed on appropriate letterhead.

Attestation Statements

U.S. Agent Designation for Service of Process (Applicant is Both Grantee and U.S. Agent) TO : American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 ATTENTION: FCC Certification – Section 2.911(d)(7) Information This letter is to co nfirm that the Applicant will also serve as the U.S. Agent for Service of Process as required by 47 CFR 2.911(d)(7). The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The Applicant further acknowledges their responsibility to i nform the FCC whenever the Designated U.S. Agent information changes. Applicant Company name: RAE Systems, Inc FRN #: 0012436135 Grantee Code: SU3 Contact Name: Bonnie Saxinger Street Address: 12220 Rojas Drive City/Province/Zip: EI Paso, Texas, 79936. United states Telephone No: +18479554040 Email: [email protected] Applicant Signature 1 : Date: June 11, 2026 Signed by (Printed Name/Title): Bonnie Saxinger 1 - Letters must be placed on appropriate letterhead.

Cover Letter(s)

050222-17 Authority to Act as Agent Date : June 10, 2026 Ame rican Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern: Int ertek Testing Services (Shanghai FTZ) Co., Ltd. is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: _____06/07/2027 By: __________________________ Saxinger Bonnie (Signature 1 ) (Print name) Title: ____ Sr. Advanced Regulatory Engineer__ On behalf of: RAE Systems Inc. (Company Name) Telephone: +18479554040 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.

Cover Letter(s)

050222-17 R equest for Confidentiality D ate: June 10, 2026 Subject: Confidentiality Request for: FCC ID: SU3PGM6810/ IC: 20969-PGM6810 P ursuant to FCC 47 CFR 0.457(d) and 0.459 and/or IC RSP-100, Section 12.4, the applicant requests that a part of the subject application(s) be held confidential. Type of Confidentiality Requested Exhibit ☐Short Term☒PermanentBlock Diagrams ☐Short Term--------------------------- External Photos ☐Short Term☐Permanent * 1 Internal Photos ☐Short Term☒PermanentOperation Description/Theory of Operation ☐Short Term☐PermanentParts List & Placement/BOM ☐Short Term☐PermanentTune-Up Procedure ☐Short Term☒PermanentSchematics ☐Short Term--------------------------- Test Setup Photos ☐Short Term☐Permanent * 1 User’s Manual RAE Systems, Inc has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. P ermanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Sho rt -Term Confidentiality for FCC Applications: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of __ (specify number of days not to exceed 180) 2 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Short Term Confidentiality for Industry Canada Applications: Starting May 2022, ISED will recognize short term confidentiality on certain exhibits until the intended date of marketing. The applicant requests the exhibits selected above as short term confidential be withheld from public view until: (specify ISED expiration date / date of marketing) . S incerely, B y: __________________________ ________________________ (Signature/Title 3 ) Sr Advanced Regulatory Engineer (Print name): Saxinger Bonnie 1 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 - Please refer to https://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on approriate letterhead.

External Photos

FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810

ID Label/Location Info

Label content: size 46mm X 41mm E-label would be used for wireless regulatory compliance information. The way to read E-label as below: Step 1: Press power on button and “R” button together to enter into Glance mode. Step 2: In Glance mode, press “R” button to move highlight to “certificate” item. Step 3: Press power on button to enter into “certificate” item, the regulatory compliance information can be reviewed in this interface.

Internal Photos

FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810

RF Exposure Info

RAE Systems, Inc MPE ASSESSMENT REPORT Report Type: FCC MPE assessment report Model: PGM-6810 REPORT NUMBER: 2604B0416SHA-003 ISSUE DATE: June 5, 2026 DOCUMENT CONTROL NUMBER: TTRFFCCMPE-01_V1 © 2018 Intertek Intertek Testing Services (Shanghai FTZ) Co., Ltd Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRFFCCMPE-01_V1© 2018 Intertek Page 2 of 8 Report no.: 2604B0416SHA-003 Applicant: RAE Systems, Inc 12220 Rojas Drive, EI Paso, Texas, 79936. United states Manufacturer: RAE Systems, Inc 12220 Rojas Drive, EI Paso, Texas, 79936. United states Factory: Honeywell Sensing and Control (China) Co Ltd. No. 1668 Tianyin Road Nanjing Science Park Jiangning District Nanjing 211100 China Product Name (PMN): ModRAE Type/Model (HVIN): PGM-6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: KDB447498 D01 General RF Exposure Guidance v06 FCC Part2.1093 FCC Part1.1307(b) PREPARED BY: REVIEWED BY: Project Engineer Alexander Li Reviewer Wakeyou Wang Report No.: 2604B0416SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 3 of 8 Revision History Report No. Version Description Issued Date 2604B0416SHA-003 Rev. 01 Initial issue of report June 5, 2026 Report No.: 2604B0416SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 4 of 8 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test (EUT) Product name: ModRAE Model name: PGM-6810 Description of EUT: The EUT is a gas detector with NFC and BLE function. Rating: AC100-240V, 50/60Hz for adapter DC 3.7V by battery Brand Name: Honeywell Category of EUT: Class A EUT type: Table top Floor standing Software Version: / Hardware Version: / Sample Identification No.: A260417-24-001 Sample received date: April 17, 2026 Date of test: April 17, 2026 to June 5, 2026 1.2 Technical Specification Frequency Range: 13.56 MHz ~ 13.56 MHz Modulation: ASK Antenna: PIFA antenna Frequency Band: 2402MHz to 2480MHz Support Standards: Bluetooth Low Energy Type of Modulation: GFSK Channel Number: 40 Data Rate 1Mbps Channel Separation: 2MHz Antenna Information: Chip Antenna, 2.1dBi Report No.: 2604B0416SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 5 of 8 1.3 Description of Test Facility Name: Intertek Testing Services (Shanghai FTZ) Co., Ltd Address: Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone: 86 21 61278200 Telefax: 86 21 54262353 The test facility is recognized, certified, or accredited by these organizations: CNAS Accreditation Lab Registration No. CNAS L21189 FCC Accredited Lab Designation Number: CN0175 IC Registration Lab CAB identifier.: CN0014 VCCI Registration Lab Registration No.: R-14243, G-10845, C-14723, T-12252 A2LA Accreditation Lab Certificate Number: 3309.02 Report No.: 2604B0416SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 6 of 8 2 MPE Assessment Test result: Pass 2.1 MPE Assessment Limit 100 MHz – 6 GHz and ≤ 50 mm Report No.: 2604B0416SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 7 of 8 100 MHz – 6 GHz and > 50 mm < 100 MHz and < 200 mm Report No.: 2604B0416SHA-003 TEST REPORT TTRFFCCMPE-01_V1© 2018 Intertek Page 8 of 8 2.2 Assessment Results Seen from the test report 2604B0416SHA-001: Field Strength EIRP EIRP Limit dBuV/m dBm mW mW 66.7 -28.5 0.0014 39 Note: EIRP= E-95.2 where: E=electric field strength in dBuV/m, EIRP= equivalent isotropic radiated power in dBm Seen from the test report 2604B0416SHA-002: Conducted Power Antenna Gain EIRP EIRP Limit dBm dBi dBm mW mW 1.53 2.1 3.63 2.31 10 Considering NFC and BLE transmitting simultaneously: 0.0014/39+2.31/10<1. Therefore, the SAR requirement is deemed to be satisfied without test. ******************************************* END ************************************

Test Report

2.45 GHz wide band, small form factor SMD chip antennaP/N 2450AT43F0100 Detail Specification: Page 1 of 5 Part Number Explanation Mechanical Dimensions L±± W±± T+ 0.1 / -0.2 a±± Want the layout file of the above? Send us a message at: www.johansontechnology.com/ask-a-question www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2014 Johanson Technology, Inc. All Rights Reserved It is recommended that the designer leave available slots for a "pi" (or shunt-series-shunt) network. The antenna matching network values above are used when antenna is mounted on Johanson's evaluation board. The matching values on client’s PCB will be different. Go to: www.johansontechnology.com/tuning.html and see how to obtain the new values. Want us to do the tuning and characterization for you? Go to: www.johansontechnology.com/ipc-antenna-services Leave space for a "pi" matching network Mounting Considerations 0.0120.0200.500.30 General Specifications 1.20 Power Capacity2W max. (CW) 0.008 Packing Style Evaluation Board eg. 2450AT43F0100E -40 to +85°C 2,000 pcs P/N Suffix 0.079 50 Ω 2450AT43F0100-EB1SMA (with female SMA connector) Operating Temperature Reel Quanity +5 ~ +35 o C, Humidity 45~75%RH 12 months 1.0 dBi typ. 2450AT43F0100 2400 - 2500 Mhz 2.1 dBi typ. 0.047+.004 / -.008 2 Suffix = S Suffix = E Bulk 0.20 + 0.1 / -0.2 0.236 0.20 eg. 2450AT43F0100S eg. 2450AT43F0100 (E or S) 0.008 100% TinSuffix = E or S Average Gain (XZ-total) Part Number Operating Frequency (MHz) Peak Gain (XZ-total) Impedance Recommended Storage Conditions Ver 2.0 4/22/2016 "High Frequency Ceramic Solutions" 1 NC Function No. Feeding Point Terminal Configuration mm 6.00 2.00 In Bulk T & R L W a T 1 2 Mount these devices with brown mark facing up. Units: mm *Line width should be designed to provide 50 Ω impedance matching characteristics. * 2.2 4.8 7.0 1.0 0.8pF GND Plane 5.6nH GND Plane 2.45 GHz wide band, small form factor SMD chip antennaP/N 2450AT43F0100 Detail Specification: Page 2 of 5 www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2014 Johanson Technology, Inc. All Rights Reserved Ver 2.0 We offer 2 free layout reviews as well as antenna tuning and characterization services (lab fee may apply). Go to: www.johansontechnology.com/ipc-antenna-services and delivery conditions when placing your order. All sales are subject to Johanson Technology, Inc. terms and conditions. Mounting Considerations "High Frequency Ceramic Solutions" Johanson Technology, Inc. reserves the right to make design changes without notice. Please confirm the specifications 4/22/2016 Want the layout file of the above? Send us a message at: www.johansontechnology.com/ask-a-question To order the EVB above for preliminary testing free (pre-tuned 50Ω EVB with a female SMA connector) Click here: www.johansontechnology.com/request-a-sample Reference p/n: 2450AT43F0100-EB1SMA Mount these devices with brown mark facing up. Units: mm *Line width should be designed to provide 50 Ω impedance matching characteristics. With Matching Circuit 2.45 GHz wide band, small form factor SMD chip antennaP/N 2450AT43F0100 Detail Specification: Page 3 of 5 www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2014 Johanson Technology, Inc. All Rights Reserved Ver 2.0 "High Frequency Ceramic Solutions" Mounting Considerations Johanson Technology, Inc. reserves the right to make design changes without notice. Please confirm the specifications and delivery conditions when placing your order. All sales are subject to Johanson Technology, Inc. terms and conditions. 4/22/2016 2.45 GHz wide band, small form factor SMD chip antennaP/N 2450AT43F0100 Detail Specification: Page 4 of 5 www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2014 Johanson Technology, Inc. All Rights Reserved Ver 2.0 "High Frequency Ceramic Solutions" Typical Electrical Characteristics (T=25°C) Johanson Technology, Inc. reserves the right to make design changes without notice. Please confirm the specifications and delivery conditions when placing your order. All sales are subject to Johanson Technology, Inc. terms and conditions. 4/22/2016 2.45 GHz wide band, small form factor SMD chip antennaP/N 2450AT43F0100 Detail Specification: Page 5 of 5 www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 2014 Johanson Technology, Inc. All Rights Reserved Ver 2.0 www.johansontechnology.com/tape-reel-packaging Soldering Information www.johansontechnology.com/ipcsoldering-profile Antenna layout and tuning techniques (How to obtain the new antenna matching values) "High Frequency Ceramic Solutions" 4/22/2016 Packaging information Johanson Technology, Inc. reserves the right to make design changes without notice. Please confirm the specifications and delivery conditions when placing your order. All sales are subject to Johanson Technology, Inc. terms and conditions. http://www.johansontechnology.com/msl-rating P/N Explanation and Breakdown www.johansontechnology.com/ipc-pn-explained More SMD Chip Antennas at: www.johansontechnology.com/antennas www.johansontechnology.com/tuning.html Antenna layout review, tuning, and characterization services http://www.johansontechnology.com/ipc-antenna-services RoHS Compliance www.johansontechnology.com/rohs-compliance MSL Info

Test Report

RAE Systems, Inc RF TEST REPORT Report Type: FCC Part 15.247 & ISED RSS-247 RF report Model: PGM-6810 REPORT NUMBER: 2604B0416SHA-002 ISSUE DATE: June 5, 2026 DOCUMENT CONTROL NUMBER: TTRF15.247-02_V1 © 2018 Intertek Intertek Testing Services (Shanghai FTZ) Co., Ltd. Building No.86, 1198 Qinzhou Road (North) Caohejing Development Zone Shanghai 200233, China Telephone: 86 21 6127 8200 www.intertek.com TEST REPORT This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. TTRF15.247-02_V1 © 2018 Intertek Page 2 of 33 Report no.: 2604B0416SHA-002 Applicant: RAE Systems, Inc 12220 Rojas Drive, EI Paso, Texas, 79936. United states Manufacturer: RAE Systems, Inc 12220 Rojas Drive, EI Paso, Texas, 79936. United states Factory: Honeywell Sensing and Control (China) Co Ltd. No. 1668 Tianyin Road Nanjing Science Park Jiangning District Nanjing 211100 China Product Name (PMN): ModRAE Type/Model (HVIN): PGM-6810 FCC ID: SU3PGM6810 IC: 20969-PGM6810 SUMMARY: The equipment complies with the requirements according to the following standard(s) or Specification: 47CFR Part 15 (2024): Radio Frequency Devices (Subpart C) ANSI C63.10 (2020) +Cor.1(2023) +C63.10a (2024) +Errata to C63.10a(2024): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices RSS-247 Issue 4 (July 2025): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence- Exempt Local Area Network (LE-LAN) Devices RSS-Gen Issue 5 (February 2021) Amendment 2: General Requirements for Compliance of Radio Apparatus PREPARED BY: REVIEWED BY: Project Engineer Alexander Li Reviewer Wakeyou Wang Report No.: 2604B0416SHA-002 TEST REPORT TTRF15.247-02_V1 © 2018 Intertek Page 3 of 33 Content REVISION HISTORY................................................................................................................................................ 5 MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6 1 GENERAL INFORMATION ............................................................................................................................. 7 1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 7 1.2 TECHNICAL SPECIFICATION .................................................................................................................................... 7 1.3 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 8 2 TEST SPECIFICATIONS ................................................................................................................................... 9 2.1 STANDARDS OR SPECIFICATION ............................................................................................................................... 9 2.2 MODE OF OPERATION DURING THE TEST ................................................................................................................... 9 2.3 TEST SOFTWARE LIST .......................................................................................................................................... 10 2.4 TEST PERIPHERALS LIST ....................................................................................................................................... 10 2.5 TEST ENVIRONMENT CONDITION: .......................................................................................................................... 10 2.6 INSTRUMENT LIST .............................................................................................................................................. 11 2.7 MEASUREMENT UNCERTAINTY ............................................................................................................................. 12 3 MINIMUM 6DB BANDWIDTH .................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Bonnie Saxinger
[email protected]Fax: +18473933546

Technical Contact

RAE Systems, IncBonnie Saxinger
[email protected]

12220 Rojas Drive, EI Paso, Texas, 79936 · EI Paso, 79936 · United States

Test Firm

Intertek Testing Services (Shanghai FTZ) Co., Ltd.Leah Xu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.50 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device contains a NFC transmitter.

Other Applications from RAE Systems, Inc

ModRAE LoRa - FCC ID SU3RM6800 - RAE Systems, Inc
SU3RM6800

ModRAE LoRa

Jun 26, 2026

Equipment Class

DTS - Digital Transmission System
PGM-2602 - FCC ID SU3-2602 - RAE Systems, Inc
SU3-2602

PGM-2602

Jan 25, 2016

Equipment Class

DTS - Digital Transmission System
PGM-2600 - FCC ID SU3-2600 - RAE Systems, Inc
SU3-2600

PGM-2600

Jan 24, 2016

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RAE Mesh Module - FCC ID SU3RM2400 - RAE Systems, Inc
SU3RM2400

RAE Mesh Module

Apr 02, 2015

Equipment Class

DTS - Digital Transmission System
RAE WIFI Module - FCC ID SU3RMWIFI - RAE Systems, Inc
SU3RMWIFI

RAE WIFI Module

Apr 02, 2015

Equipment Class

DTS - Digital Transmission System