Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
www.ui.com Date: 26 July 2024 Federal Communications Commission (the “Commission” or “FCC”) Authorization and Evaluation Division 7435 Oakland Mills Rd. Columbia, MD 21046 USA RE: Attestation Statements Part 2.911(d)(5)(i) Filing – FCC ID: SWX-E7 Ubiquiti Inc. (“the applicant”) certifies that, as of the date of the application, the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Alex Macon Ubiquiti lnc. Compliance Officer
www.ui.com Date: 26 July 2024 Federal Communications Commission (the “Commission” or “FCC”) Authorization and Evaluation Division 7435 Oakland Mills Rd. Columbia, MD 21046 USA RE: Attestation Statements Part 2.911(d)(5)(ii) Filing – FCC ID: SWX-E7 Ubiquiti Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List 1 (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Alex Macon Ubiquiti lnc. Compliance Officer 1 https://www.fcc.gov/supplychain/coveredlist
www.ui.com Date: 17 February 2023 Federal Communications Commission (the “Commission” or “FCC”) Authorization and Evaluation Division 7435 Oakland Mills Rd. Columbia, MD 21046 RE: Attestation Statement Part 2.911(d)(7) – FCC: SWX Ubiquiti Inc. (“the Applicant”, FRN: 0012268215) certifies that, as of the date of this letter agreement, C T Corporation System is the Applicant’s designated U.S. agent for service of process for the above referenced grantee code. Applicant agrees to maintain an agent for no less than one year after (i) the Applicant has terminated all marketing and importation or (ii) the conclusion of any Commission-related proceeding involving the equipment certified by the FCC. C T Corporation System accepts, as of the date hereof, the obligation of the designated U.S. agent for service of process for the above referenced grantee code. Designated U.S. Agent Information: Name: C T Corporation System Address: 1015 15th Street N.W., Suite 1000, Washington, D.C., 20005 Email: [email protected] U.S. Agent FRN: The agent for service of process does no other business with the FCC and does not have an FRN. Sincerely, Ubiquiti Inc. C T Corporation System Alex Macon Denise Bell, Assistant Secretary By:
www.ui.com Date: 3 October 2024 Federal Communications Commission 7435 Oakland Mills Rd. Columbia, MD 21046 RE: Request for Confidentiality In reference to the application under FCC ID: SWX-E7, and pursuant to Sections 0.457(d)1(ii) and 0.459 of the Commission’s Rules, Ubiquiti Networks hereby requests permanent confidential treatment of the accompanying information as outlined below: Block Diagram Schematics Theory of Operation Software Security 80-70178-5_AB_Qualcomm 3D Building Elevation PIA Confidential Information 80-70178-11_AB_Qualcomm Wi-Fi Location PIA Confidential Information 80-70178-18_AB_Qualcomm Geolocation Feature Regulatory Certification Procedure MH80-70178-13_AA-Qualcomm 3D Building Elevation FCC PIA Inquiry Correspondence_COVER MH80-70178_AA-Qualcomm Wi-Fi Location FCC PIA Inquiry Correspondence_COVER Qualcomm 3D Building Elevation PIA Inquiry Correspondence Qualcomm Wi-Fi Location FCC PIA Inquiry Correspondence The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to Ubiquiti Networks and provide unjustified benefits to its competitors. In addition to the above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the important rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short term confidentiality on the following attachments until 180 days from grant date. External Photos Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondence during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Ubiquiti Networks understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. www.ui.com Sincerely, Alex Macon Ubiquiti lnc. Compliance Manager
685 3 RD AVE. • NEW Y0RK, NY 10071 • www.ui.com Date: 26 July 2024 Federal Communications Commission 7435 Oakland Mills Rd. Columbia, MD 21046 RE: Request for Original Equipment Certification – FCC: SWX-E7 It is hereby requested that Ubiquiti Inc. obtain FCC Original Equipment Certification of a radio apparatus on the Ubiquiti Inc. product E7. The associated FCC: number is listed above. The E7 is a WiFi 7 access point with (1) 10GbE PoE port and (1) 1GbE PoE port. The E7 transmits in the 2.4 GHz, 5 GHz, and 6 GHz frequency bands using integral antennas and is powered by an 802.3at PoE power adapter. Sincerely, Alex Macon Ubiquiti lnc. Compliance
M/N: E7 IPX6 IC:6545A-E7 FCC ID: SWX-E7 Ubiquiti Inc. 685 Third Avenue, New York, NY 10017 USA xxxxyy xxxxxxxxxXXX xxxxxx Label Location on Back of DUT
M/N: E7 IPX6 Indoor Use Only IC:6545A-E7 FCC ID: SWX-E7 Ubiquiti Inc. 685 Third Avenue, New York, NY 10017 USA xxxxyy xxxxxxxxxXXX xxxxxx Label Location on Back of DUT
Maximum Permissible Exposure FCC Part 2 Sections §2.1091 and §2.1093 Test Requirement(s): §15.407(f): U-NII devices are subject to the radio frequency radiation exposure requirements specified in §1.1307(b), §2.1091 and §2.1093 of this chapter, as appropriate. All equipment shall be considered to operate in a “general population/uncontrolled” environment. RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit: EUT’s operating frequencies @ WiFi 2412 – 2462 MHz; UNII-1 5180 – 5240 MHz; UNII-2a 5260 – 5320 MHZ; UNII-2c 5500 – 5720 MHz; UNII-3 5745 – 5825 MHz; UNII-5 5955 – 6415; UNII-6 6435 – 6515; UNII-7 6535 – 6885; UNII-8 6895 – 7115; Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √(PG / 4S) where, S = Power Density (mW/cm 2 ) P = Power Input to antenna (mW) G = Antenna Gain (numeric value) R = Distance (cm) Test Results: FCC Frequency (MHz) Con. Pwr. (dBm) Con. Pwr. (mW) Ant. Gain (dBi) Ant. Gain numeric Pwr. Density (mW/cm 2 ) Limit (mW/cm 2 ) Margin Distance (cm) Result 2457* 29.16 824.14 5 3.16 0.23 1.0 -0.77 30 Pass 5240* 29.78 950.60 6 3.98 0.34 1.0 -0.66 30 Pass 5250 23.84 242.10 6 3.98 0.09 1.0 -0.91 30 Pass 5530 23.80 239.88 6 3.98 0.08 1.0 -0.92 30 Pass 5775 29.71 935.41 6 3.98 0.33 1.0 -0.67 30 Pass 6825* 23.82 240.99 6 3.98 0.08 1.0 -0.66 30 Pass *Simultaneous Transmission (Worse case): 0.65 1.0 -0.35 30 Pass The safe distance for SWX-E7 where Power Density is less than the MPE Limit listed above was found to be 30 cm. This device does not perform power tune-ups, therefore the maximum power is used for this analysis.
427 West 12800 South Draper, UT 84020 Test Report Certification FCC ID SWX-E7 ISED ID 6545A-E7 Equipment Under Test E7 Test Report Serial Number TR9005_04 Date of Test(s) 20-21, 23 February and 9, 16 April 2024 Report Issue Date 9 May 2024 Test Specification Applicant 47 CFR FCC Part 15, Subpart E Ubiquiti Inc. 685 Third Avenue New York, NY 10017 U.S.A. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_04 Page 2 of 32 PROPRIETARY Certification of Engineering Report This report has been prepared by Unified Compliance Laboratory (UCL) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart E. This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. Applicant Ubiquiti Inc. Manufacturer Ubiquiti Inc. Brand Name UBIQUITI Model Number E7 FCC ID SWX-E7 ISED ID 6545A-E7 On this 9 th day of May 2024, I individually and for Unified Compliance Laboratory certify that the statements made in this engineering report are true, complete, and correct to the best of my knowledge and are made in good faith. Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government. Unified Compliance Laboratory Written By: Evan J. Hartzell Reviewed By: Richard L. Winter 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_04 Page 3 of 32 PROPRIETARY Revision History Revision Description Date 01 Original Report Release 9 May 2024 02 Add Canada Power Table in Section 5.4 21 September 2024 03 Amended KDB Reference in Sections 5.3, 5.4 and 5.6, and PSD section to account for directional gain reduction. 30 September 2024 04 Added Canada Limit in Section 5.4 28 October 2024 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_04 Page 4 of 32 PROPRIETARY Table of Contents 1 Client Information ................................................................................................................................. 5 1.1 Applicant ....................................................................................................................................... 5 1.2 Manufacturer ................................................................................................................................. 5 2 Equipment Under Test (EUT) ............................................................................................................... 6 2.1 Identification of EUT .................................................................................................................... 6 2.2 Description of EUT ....................................................................................................................... 6 2.3 EUT and Support Equipment ........................................................................................................ 6 2.4 Interface Ports on EUT ................................................................................................................. 7 2.5 Operating Environment ................................................................................................................. 7 2.6 Operating Modes ........................................................................................................................... 7 2.7 EUT Exercise Software ................................................................................................................. 7 2.8 Block Diagram of Test Configuration .......................................................................................... 8 2.9 Modification Incorporated/Special Accessories on EUT .............................................................. 8 2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard .................... 8 3 Test Specification, Method and Procedures .......................................................................................... 9 3.1 Test Specification .......................................................................................................................... 9 3.2 Methods & Procedures .................................................................................................................. 9 3.3 FCC Part 15, Subpart E ................................................................................................................. 9 3.4 Results ........................................................................................................................................... 9 3.5 Test Location .............................................................................................................................. 10 4 Test Equipment ................................................................................................................................... 11 4.1 Conducted Emissions at Mains Ports .......................................................................................... 11 4.2 Direct Connect at the Antenna Port Tests ................................................................................... 11 4.3 Radiated Emissions ..................................................................................................................... 12 4.4 Equipment Calibration ................................................................................................................ 13 4.5 Measurement Uncertainty ........................................................................................................... 13 5 Test Results ......................................................................................................................................... 14 5.1 §15.203 Antenna Requirements ....................…
Text truncated - open the document above for the full version.
427 West 12800 South Draper, UT 84020 Test Report Attachment FCC ID SWX-E7 ISED ID 6545A-E7 Equipment Under Test E7 Test Report Serial Number TR9005_02 Date of Test(s) 20-21, 23 February and 9, 16 April 2024 Report Issue Date 30 September 2024 Test Personnel Testing performed by Evan J. Hartzell Test Location Testing was performed at the Unified Compliance Laboratory located at 427 West 12800 South, Draper, UT 84020. Unified Compliance Laboratory is accredited by National Voluntary Laboratory Accreditation Program (NVLAP); NVLAP Code 600241-0 which is effective until 30 June 2024. This site has also been registered with Innovations, Science and Economic Development (ISED) department as was accepted under Appendix B, Phase 1 procedures of the APEC Tel MRA for Canadian recognition. ISED No.: 25346, effective until 30 June 2024. Unified Compliance Laboratory has been assigned Conformity Assessment Number US0223 by ISED and MRA US5037. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 2 of 41 PROPRIETARY Revision History Revision Description Date 01 Original Report Release 9 May 2024 02 Updated to include PSD test settings 30 September 2024 1 UNII-1 Band Table 1: Summary Test Frequency Nominal Power Nominal Bandwidth Result MHz dBm MHz Emission Bandwidth 26 dB 5180.000 24.0 20.000000 PASS RF output power 5180.000 24.0 20.000000 PASS Power Spectral Density 5180.000 24.0 20.000000 PASS Occupied Channel Bandwidth 99% 5180.000 24.0 20.000000 PASS Emission Bandwidth 26 dB 5210.000 24.0 20.000000 PASS Power Spectral Density 5210.000 24.0 20.000000 PASS Occupied Channel Bandwidth 99% 5210.000 24.0 20.000000 PASS Emission Bandwidth 26 dB 5240.000 24.0 20.000000 PASS Power Spectral Density 5240.000 24.0 20.000000 PASS Occupied Channel Bandwidth 99% 5240.000 24.0 20.000000 PASS Emission Bandwidth 26 dB 5190.000 24.0 40.000000 PASS Power Spectral Density 5190.000 24.0 40.000000 PASS Occupied Channel Bandwidth 99% 5190.000 24.0 40.000000 PASS Emission Bandwidth 26 dB 5230.000 24.0 40.000000 PASS Power Spectral Density 5230.000 24.0 40.000000 PASS Occupied Channel Bandwidth 99% 5230.000 24.0 40.000000 PASS Emission Bandwidth 26 dB 5210.000 24.0 80.000000 PASS Power Spectral Density 5210.000 24.0 80.000000 PASS Occupied Channel Bandwidth 99% 5210.000 24.0 80.000000 PASS 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 3 of 41 PROPRIETARY 2 Testcases 2.1 Emission Bandwidth 26 dB (5180 MHz, 20 MHz, 24.000 dBm) Customized settings. Table 2: 26 dB Bandwidth DUT Frequency Bandwidth Limit Min Limit Max Band Edge Left Band Edge Right Max Level Result MHz MHz MHz MHz MHz MHz dBm 5180.000000 23.200000 --- --- 5168.350000 5191.550000 3.7 PASS Figure 1: 26 dB Bandwidth Level in dBm 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 4 of 41 PROPRIETARY Table 3: Measurement Setting Instrument Value Target Value Start Frequency 5.15000 GHz 5.15000 GHz Stop Frequency 5.21000 GHz 5.21000 GHz Span 60.000 MHz 60.000 MHz RBW 200.000 kHz ~ 200.000 kHz VBW 1.000 MHz >= 600.000 kHz SweepPoints 600 ~ 600 Sweeptime 37.969 μs AUTO Reference Level 20.000 dBm 20.000 dBm Attenuation 40.000 dB AUTO Detector MaxPeak MaxPeak SweepCount 200 200 Filter 3 dB 3 dB Trace Mode Max Hold Max Hold Sweeptype FFT AUTO Preamp off off 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 5 of 41 PROPRIETARY 2.2 RF output power (5180 MHz, 20 MHz, 24.000 dBm) Customized settings. Table 4: Result DUT Frequency Gated RMS Limit Max Gated EIRP DutyCycle Result MHz dBm dBm dBm % 5180.000000 25.5 30.0 25.5 99.718 PASS Table 5: OSP PowerMeter settings Setting Instrument Value Target Value Measurement Time 1.000 s 1.000 s Points 1000000 1000000 Time resolution 1.000 μs 1.000 μs 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 6 of 41 PROPRIETARY 2.3 Power Spectral Density (5180 MHz, 20 MHz, 24.000 dBm) Customized settings. Table 6: Result DUT Frequency Frequency PSD Limit Max Result MHz MHz dBm dBm 5180.000000 5188.316832 9.869 17.0 PASS Table 7: Ports Port State 1 used 2 used 3 used 4 used Figure 2: Power Spectral Density Level in dBm 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 7 of 41 PROPRIETARY Table 8: Measurement Setting Instrument Value Target Value Start Frequency 5.17000 GHz 5.17000 GHz Stop Frequency 5.19000 GHz 5.19000 GHz Span 20.000 MHz 20.000 MHz RBW 1.000 MHz <= 1.000 MHz VBW 3.000 MHz >= 3.000 MHz SweepPoints 101 ~ 40 Sweeptime 2.020 ms 2.020 ms Reference Level 20.000 dBm 20.000 dBm Attenuation 40.000 dB AUTO Detector RMS RMS SweepCount 100 100 Filter 3 dB 3 dB Trace Mode Average Power Average Power Sweeptype FFT AUTO Preamp off off 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 8 of 41 PROPRIETARY 2.4 Occupied Channel Bandwidth 99% (5180 MHz, 20 MHz, 24.000 dBm) Customized settings. Table 9: 99 % Bandwidth DUT Frequency Bandwidth Limit Min Limit Max Band Edge Left Band Edge Right Result MHz MHz MHz MHz MHz MHz 5180.000000 19.500000 --- --- 5170.375000 5189.875000 PASS Figure 3: 99 % Bandwidth Level in dBm 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 9 of 41 PROPRIETARY Table 10: Measurement Setting Instrument Value Target Value Start Frequency 5.16000 GHz 5.16000 GHz Stop Frequency 5.20000 GHz 5.20000 GHz Span 40.000 MHz 40.000 MHz RBW 500.000 kHz >= 500.000 kHz VBW 2.000 MHz >= 1.500 MHz SweepPoints 160 ~ 160 Sweeptime 11.344 μs AUTO Reference Level 20.000 dBm 20.000 dBm Attenuation 40.000 dB AUTO Detector MaxPeak MaxPeak SweepCount 200 200 Filter 3 dB 3 dB Trace Mode Max Hold Max Hold Sweeptype FFT AUTO Preamp off off 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 10 of 41 PROPRIETARY 427 West 12800 South, Draper, UT 84020 TR9005_E7_FCC_15.407_UNII-1_Annex_02 Page 11 of 41 PROPRIETARY 2.5 Emission Bandwidth 26 dB (5210 MHz, 20 M…
Text truncated - open the document above for the full version.
427 West 12800 South Draper, UT 84020 Test Report Certification FCC ID SWX-E7 ISED ID 6545A-E7 Equipment Under Test E7 Test Report Serial Number TR9009_02 Date of Test(s) 22, 23 February and 11, 16, 25 April 2024 Report Issue Date 9 May 2024 Test Specification Applicant 47 CFR FCC Part 15, Subpart E Ubiquiti Inc. 685 Third Avenue New York, NY 10017 U.S.A. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR9009_E7_15.407_UNII-3_02 Page 2 of 25 PROPRIETARY Certification of Engineering Report This report has been prepared by Unified Compliance Laboratory (UCL) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart E. This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. Applicant Ubiquiti Inc. Manufacturer Ubiquiti Inc. Brand Name UBIQUITI Model Number E7 FCC ID SWX-E7 ISED ID 6545A-E7 On this 9 th day of May 2024, I individually and for Unified Compliance Laboratory certify that the statements made in this engineering report are true, complete and correct to the best of my knowledge and are made in good faith. Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government. Unified Compliance Laboratory Written By: Evan J. Hartzell Reviewed By: Richard L. Winter 427 West 12800 South, Draper, UT 84020 TR9009_E7_15.407_UNII-3_02 Page 3 of 25 PROPRIETARY Revision History Revision Description Date 01 Original Report Release 9 May 2024 02 Amended KDB Reference in Sections 5.3, 5.4 and 5.6 27 September 2024 427 West 12800 South, Draper, UT 84020 TR9009_E7_15.407_UNII-3_02 Page 4 of 25 PROPRIETARY Table of Contents 1 Client Information ................................................................................................................................. 5 1.1 Applicant ....................................................................................................................................... 5 1.2 Manufacturer ................................................................................................................................. 5 2 Equipment Under Test (EUT) ............................................................................................................... 6 2.1 Identification of EUT .................................................................................................................... 6 2.2 Description of EUT ....................................................................................................................... 6 2.3 EUT and Support Equipment ........................................................................................................ 6 2.4 Interface Ports on EUT ................................................................................................................. 7 2.5 Operating Environment ................................................................................................................. 7 2.6 Operating Modes ........................................................................................................................... 7 2.7 EUT Exercise Software ................................................................................................................. 7 2.8 Block Diagram of Test Configuration .......................................................................................... 8 2.9 Modification Incorporated/Special Accessories on EUT .............................................................. 8 2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard .................... 8 3 Test Specification, Method and Procedures .......................................................................................... 9 3.1 Test Specification .......................................................................................................................... 9 3.2 Methods & Procedures .................................................................................................................. 9 3.3 FCC Part 15, Subpart E ................................................................................................................. 9 3.4 Results ........................................................................................................................................... 9 3.5 Test Location .............................................................................................................................. 10 4 Test Equipment ................................................................................................................................... 11 4.1 Conducted Emissions at Mains Ports .......................................................................................... 11 4.2 Direct Connect at the Antenna Port Tests ................................................................................... 11 4.3 Radiated Emissions ..................................................................................................................... 12 4.4 Equipment Calibration ................................................................................................................ 13 4.5 Measurement Uncertainty ........................................................................................................... 13 5 Test Results ......................................................................................................................................... 14 5.1 §15.203 Antenna Requirements .................................................................................................. 14 5.2 Conducted Emissions at Mains Ports Data .........................................................…
Text truncated - open the document above for the full version.
427 West 12800 South Draper, UT 84020 Test Report Attachment FCC ID SWX-E7 ISED ID 6545A-E7 Equipment Under Test E7 Test Report Serial Number TR1234_02 Date of Test(s) 22, 23 February and 11, 16, 25 April 2024 Report Issue Date 30 September 2024 Test Personnel Testing performed by Evan J. Hartzell Test Location Testing was performed at the Unified Compliance Laboratory located at 427 West 12800 South, Draper, UT 84020. Unified Compliance Laboratory is accredited by National Voluntary Laboratory Accreditation Program (NVLAP); NVLAP Code 600241-0 which is effective until 30 June 2024. This site has also been registered with Innovations, Science and Economic Development (ISED) department as was accepted under Appendix B, Phase 1 procedures of the APEC Tel MRA for Canadian recognition. ISED No.: 25346, effective until 30 June 2024. Unified Compliance Laboratory has been assigned Conformity Assessment Number US0223 by ISED and MRA US5037. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR9009_E7_FCC_15.407_UNII-3_Annex_02 Page 2 of 82 PROPRIETARY Revision History Revision Description Date 01 Original Report Release 9 May 2024 02 Added test settings for PSD. 30 September 2024 1 UNII-3 Band Table 1: Summary Test Frequency Nominal Power Nominal Bandwidth Result MHz dBm MHz Emission Bandwidth 26 dB 5745.000 24.0 20.000000 PASS RF output power 5745.000 24.0 20.000000 PASS Power Spectral Density 5745.000 24.0 20.000000 PASS Minimum Emission Bandwidth 6 dB 5745.000 24.0 20.000000 PASS Occupied Channel Bandwidth 99% 5745.000 24.0 20.000000 PASS Tx Spurious Emission 5745.000 24.0 20.000000 PASS Emission Bandwidth 26 dB 5775.000 24.0 20.000000 PASS Power Spectral Density 5775.000 24.0 20.000000 PASS Minimum Emission Bandwidth 6 dB 5775.000 24.0 20.000000 PASS Occupied Channel Bandwidth 99% 5775.000 24.0 20.000000 PASS Tx Spurious Emission 5775.000 24.0 20.000000 PASS Emission Bandwidth 26 dB 5825.000 24.0 20.000000 PASS Power Spectral Density 5825.000 24.0 20.000000 PASS Minimum Emission Bandwidth 6 dB 5825.000 24.0 20.000000 PASS Occupied Channel Bandwidth 99% 5825.000 24.0 20.000000 PASS Tx Spurious Emission 5825.000 24.0 20.000000 PASS Emission Bandwidth 26 dB 5755.000 24.0 40.000000 PASS Power Spectral Density 5755.000 24.0 40.000000 PASS Minimum Emission Bandwidth 6 dB 5755.000 24.0 40.000000 PASS Occupied Channel Bandwidth 99% 5755.000 24.0 40.000000 PASS Tx Spurious Emission 5755.000 24.0 40.000000 PASS Emission Bandwidth 26 dB 5775.000 24.0 40.000000 PASS Power Spectral Density 5775.000 24.0 40.000000 PASS Minimum Emission Bandwidth 6 dB 5775.000 24.0 40.000000 PASS Occupied Channel Bandwidth 99% 5775.000 24.0 40.000000 PASS Tx Spurious Emission 5775.000 24.0 40.000000 PASS Emission Bandwidth 26 dB 5795.000 24.0 40.000000 PASS Power Spectral Density 5795.000 24.0 40.000000 PASS Minimum Emission Bandwidth 6 dB 5795.000 24.0 40.000000 PASS Occupied Channel Bandwidth 99% 5795.000 24.0 40.000000 PASS Tx Spurious Emission 5795.000 24.0 40.000000 PASS 427 West 12800 South, Draper, UT 84020 TR9009_E7_FCC_15.407_UNII-3_Annex_02 Page 3 of 82 PROPRIETARY Test Frequency Nominal Power Nominal Bandwidth Result MHz dBm MHz Emission Bandwidth 26 dB 5775.000 24.0 80.000000 PASS Power Spectral Density 5775.000 24.0 80.000000 PASS Minimum Emission Bandwidth 6 dB 5775.000 24.0 80.000000 PASS Occupied Channel Bandwidth 99% 5775.000 24.0 80.000000 PASS Tx Spurious Emission 5775.000 24.0 80.000000 PASS 427 West 12800 South, Draper, UT 84020 TR9009_E7_FCC_15.407_UNII-3_Annex_02 Page 4 of 82 PROPRIETARY 2 Testcases 2.1 Emission Bandwidth 26 dB (5745 MHz, 20 MHz, 24.000 dBm) Customized settings. Table 2: 26 dB Bandwidth DUT Frequency Bandwidth Limit Min Limit Max Band Edge Left Band Edge Right Max Level Result MHz MHz MHz MHz MHz MHz dBm 5745.000000 47.400000 --- --- 5721.150000 5768.550000 8.7 PASS Figure 1: 26 dB Bandwidth Level in dBm 427 West 12800 South, Draper, UT 84020 TR9009_E7_FCC_15.407_UNII-3_Annex_02 Page 5 of 82 PROPRIETARY Table 3: Measurement Setting Instrument Value Target Value Start Frequency 5.71500 GHz 5.71500 GHz Stop Frequency 5.775…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 4 | 15E | 5.75 GHz - 5.83 GHz | 935.00 mW |
SuperLink Gateway HA
Equipment Class
DTS - Digital Transmission SystemDigital Transmission Radio
Equipment Class
DTS - Digital Transmission SystemRecessed Entry Sensor
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterG6 Edge Dome
Equipment Class
DTS - Digital Transmission SystemG6 Edge Turret