Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 21, 2009
Application Purpose
Original Equipment
Date of Application
Dec 21, 2009
Equipment Note
802.11 n radio
Frequency Range
5745.00000000 - 5825.00000000
Company
Ubiquiti Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

M5G OEM Users Guide TECH SPECS DataRateAvg. TXToleranceDataRateSensitivityTolerance 1-24Mbps20 dBm+/-2dB1-24Mbps-97 dBm min.+/-2dB 36Mbps19 dBm+/-2dB36Mbps-80 dBm+/-2dB 48Mbps18 dBm+/-2dB48Mbps-77 dBm+/-2dB 54Mbps16 dBm+/-2dB54Mbps-75 dBm+/-2dB MCS020 dBm+/-2dBMCS0-96 dBm+/-2dB MCS120 dBm+/-2dBMCS1-95 dBm+/-2dB MCS220 dBm+/-2dBMCS2-92 dBm+/-2dB MCS320 dBm+/-2dBMCS3-90 dBm+/-2dB MCS419 dBm+/-2dBMCS4-86 dBm+/-2dB MCS517 dBm+/-2dBMCS5-83 dBm+/-2dB MCS616 dBm+/-2dBMCS6-77 dBm+/-2dB MCS715 dBm+/-2dBMCS7-74 dBm+/-2dB 5GHz 11n 5GHz 11n Shock and VibrationETSI300-019-1.4 Power MethodPassive Power over Ethernet (pairs 4,5+; 7,8 return) Operating Temperature -30C to 75C Operating Humidity5 to 95% Condensing Mounting KitPole Mounting Kit included Max Power Consumption3.5 Watts Power Supply5V USP+POE Adapter Included Weight0.5 kg Enclosure CharacteristicsOutdoor UV Stabalized Plastic PHYSICAL / ELECTRICAL / ENVIRONMENTAL Enclosure Size16cm length x 8cm width x 3cm height OPERATING FREQUENCY 5745MHz-5825MHz 5GHz TX POWER SPECIFICATIONS5GHz RX SPECIFICATIONS 11a 11a REGULATORY / COMPLIANCE INFORMATION Wireless ApprovalsFCC Part 15.247, IC RS210, CE RoHS ComplianceYES SYSTEM INFORMATION Processor SpecsAtheros MIPS 24KC, 400MHz Memory Information32MB SDRAM, 8MB Flash Networking Interface1 X 10/100 BASE-TX (Cat. 5, RJ-45) Ethernet Interface COMPLIANCE INFORMATION FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pro-vide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The antennas used for this transmitter must be installed to provide a separation distance of at least following distance from all persons and must not be located or operating in conjunction with any other antenna or transmitter. 68.6cm distance for the Dish Antenna 136.9cm distance for the Grid Antenna INDUSTRY CANADA This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. The device has been designed to operate with the antennas listed below and having a maximum gain of 28dBi. Antennas not included in this list or having a gain greater than 28dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms This device must be professionally installed and is designed strictly for for outdoor point- to-point wireless links.

Cover Letter(s)

Ubiquiti Networks, Inc. 91 E. Tasman San Jose, CA 95134 12/13/09 Attn: MET laboratories 914 West Patapsco Ave. Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR M5G (FCC ID: SWX-M5G, IC: 6545A-M5G) To Whom It May Concern: This letter serves as an official request for confidentiality under FCC Rule Section 0.457 & 0.459. We have requested that the schematics, block diagrams, theory of operation, and internal photos required to be submitted with this application be withheld from public review. These documents contain proprietary information that would sacrifice our competitive advantage in the marketplace if made public. Additionally, the mechanical enclosure locking is proprietary and not possible to open by general public Please contact me if there is any information you may need. Sincerely, Robert J. Pera Senior RF Engineer

Cover Letter(s)

Jennifer Sanchez From: Jennifer Sanchez Sent: Monday, December 21, 2009 7:54 PM To: 'Dusmantha Tennakoon' Cc: Jenn Warnell; Shawn McMillen; Jennifer Sanchez Subject: RE: Technical Review Request: 81790B Ubiquiti Networks - FCC/IC TCB (M5G Model) Importance: High Attachments: 81790 Ubiquiti Networks - IC Package_M5G_Rev1.doc; EMCS81790B-FCC247_Rev1.pdf; M5G user guide_Rev1.pdf 12/21/2009 HI Dusmantha, Please see response below and revised report, IC package and manual attached. FCC: 1. The user manual should include a statement that installation should only be for point-to-point. Please see revised manual 2. There appears to be a typo in the radiated emissions section of the test report. The raw amplitude is stated as being measured at 3m but there is also a distance correction factor. Please correct this typo. Measurements were taken at 1m meter. The typo has been corrected, please see revised report. IC: 1.The SA settings for the 6dB and 99% Occupied bandwidth are incorrect. The 6 dB bandwidth needs to be measured with a RBW that is close to 1% of the emissions bandwidth. The 99% bandwidth needs to be measured with a RBW that is close to 1% of the selected span without being below 1%. Corrected, please see revised report. 2.Please clarify how the receiver spurs measurements were performed (i.e. conducted or radiated)? It appears to have been performed radiated. Were the antenna correction factors and cable loss taken into consideration? The limits stated in the standard are in terms of field strength at 3m. However, the SA units are in terms of dBm. Please clarify how the determination was made that the emissions seen pass the field strength limits. There is also what appears to be a limit line on the plots. Please clarify what this line is. Corrected, please see revised report. 3.The RF evaluation in Annex A of the Technical Brief Cover Sheet should state General Public Use. The standard used for evaluation is also incorrect. The RF value should also state 1 mW/cm2. Corrected, please see revised annex A. 4.Reference source not found error on page 15 of 84 of the test report. Corrected, please see revised report. 5. Page 15 of 84 also states that the emissions met class B. However, the tabulated data seems to show class A limits. Please update the test report. Corrected, please see revised report.

ID Label/Location Info

M5G FCC ID: SWX-M5G IC: 6545A-M5G Ubiquiti Networks This device complies with Part15 of FCC rules. Operation is subject to the following two conditions: 1.) This device may not cause harmful interference and, 2.) This device must accept any interference received, including interference that maay cause undesired operation www.ubnt.com

RF Exposure Info

5 GHz Antenna List M5G 1. 28dBi Grid Antenna 2. 22dBi Dish Antenna Ubiquiti AG-5G-28 Gain: 28dBi Dimensions: 15.7 x 23.6 inches (400 x 600 mm) 1. AzimuthElevation 2. Ubiquiti D-5G-22 Gain: 22dBi Dimensions: 12 inches diameter

RF Exposure Info

Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS81790B-FCC247 © 2009, MET Laboratories, Inc. Page 36 of 84 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria for Intentional Radiators § 15.247(b) RF Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit Calculation: EUT’s operating frequencies @ 5745-5825 MHz ; highest conducted power = 25.72dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 22 dBi Dish Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √PG / 4S where, S = Power Density (1 mW/cm 2 ) P = Power Input to antenna (373.25mW) G = Antenna Gain (158.49 numeric) R = (373.25*158.49/ 4*3.14*1.0) 1/2 = (59156.1 / 12.56) 1/2 = 68.6cm MPE Limit Calculation: EUT’s operating frequencies @ 5745-5825 MHz ; highest conducted power = 25.72dBm (peak) therefore, Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 EUT maximum antenna gain = 28 dBi Grid where, S = Power Density (1 mW/cm 2 ) P = Power Input to antenna (373.25mW) G = Antenna Gain (630.9numeric) R = (373.25*630.9/ 4*3.14*1.0) 1/2 = (235504.9 / 12.56) 1/2 = 136.9cm

Test Report

MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 The Nation’s First Licensed Nationally Recognized Testing Laboratory December 22, 2009 Ubiquiti Networks 91 E. Tasman San Jose, CA 95134 Dear Robert Pera, Enclosed is the EMC Wireless test report for compliance testing of the Ubiquiti Networks, M5G as tested to the requirements of Title 47 of the CFR, Ch . 1 (10-1-06 ed.), Part 15, Subpart B, ICES-003, Issue 4 February 2004 for a Class B Digital Device and FCC Part 15 Subpart C, RSS-210, Issue 7, June 2007 for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Sanchez Documentation Department Reference: (\Ubiquiti Networks\EMCS81790B-FCC247_Rev2) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. Electromagnetic Compatibility Ubiquiti Networks Cover Page M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS81790B-FCC247_Rev2 © 2009, MET Laboratories, Inc. Page ii of ix DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Ubiquiti Networks M5G Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class B Digital Devices & 15.247 Subpart C & RSS-210, Issue 7, June 2007 for Intentional Radiators MET Report: EMCS81790B-FCC247_Rev2 December 22, 2009 Prepared For: Ubiquiti Networks 91 E. Tasman San Jose, CA 95134 Prepared By: MET Laboratories, Inc. 3162 Belick St. Santa Clara, CA 95054 Electromagnetic Compatibility Ubiquiti Networks Cover Page M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS81790B-FCC247_Rev2 © 2009, MET Laboratories, Inc. Page iii of ix DOC-EMC702 6/18/2009 Electromagnetic Compatibility Criteria Test Report for the Ubiquiti Networks M5G Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B & ICES-003 for Class B Digital Devices & 15.247 Subpart C & RSS-210, Issue 7, June 2007 for Intentional Radiators Anderson Soungpanya, Project Engineer Jennifer Sanchez Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of oper ation in accord ance with the requirements of th e FCC Rules Parts 15B, 15.247 and Ind ustry Can ada standards ICES-003, Issue 4 Februar y 2004, R SS-210, Issue 7 , June 2007 un der normal use and maintenance. Shawn McMillen, Wireless Manager, Electromagnetic Compatibility Lab Electromagnetic Compatibility Ubiquiti Networks Report Status M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS81790B-FCC247_Rev2 © 2009, MET Laboratories, Inc. Page iv of ix DOC-EMC702 6/18/2009 Report Status Sheet Revision Report Date Reason for Revision  December 15, 2009 Initial Issue. 1 December 16, 2009 Final Issue 2 December 21, 2009 Revision 1 3 December 22, 2009 Revision 2 Electromagnetic Compatibility Ubiquiti Networks Table of Contents M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 MET Report: EMCS81790B-FCC247_Rev2 © 2009, MET Laboratories, Inc. Page v of ix DOC-EMC702 6/18/2009 Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview.............................................................................................................................................................4 B. References...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample.................................................................................................................................5 E. Equipment Configuration....................................................................................................................................8 F. Support Equipment .............................................................................................................................................8 G. Ports and Cabling Information............................................................................................................................8 H. Mode of Operation.....................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Electromagnetic Compatibility Ubiquiti Networks Unintentional Radiators M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Conducted Emission Limits Test Setup Photograph 1. Conducted Emissions, Test Setup MET Report: EMCS81790B-FCC247 © 2009, MET Laboratories, Inc. Page 14 of 84 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Unintentional Radiators M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Radiated Emission Limits Test Setup Photograph 2. Radiated Emission, Test Setup MET Report: EMCS81790B-FCC247 © 2009, MET Laboratories, Inc. Page 19 of 84 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Unintentional Radiators M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Radiated Emission Limits Test Setup Photograph 3. Radiated Emission, above 1GHz Test Setup MET Report: EMCS81790B-FCC247 © 2009, MET Laboratories, Inc. Page 20 of 84 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Conducted Emission Limits Test Setup Photograph 4. Conducted Emissions, 15.207, Test Setup MET Report: EMCS81790B-FCC247 © 2009, MET Laboratories, Inc. Page 26 of 84 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Radiated Spurious Test Setup Photographs Photograph 5. Radiated Spurious, Test Setup (Dish Antenna) MET Report: EMCS81790B-FCC247 © 2009, MET Laboratories, Inc. Page 52 of 84 DOC-EMC702 6/18/2009 Electromagnetic Compatibility Ubiquiti Networks Intentional Radiators M5G CFR Title 47, Part 15B, 15.247; RSS-210, Issue 7, June 2007 & ICES-003 Radiated Spurious Test Setup Photographs Photograph 6. Radiated Spurious, Test Setup (Grid Antenna) MET Report: EMCS81790B-FCC247 © 2009, MET Laboratories, Inc. Page 53 of 84 DOC-EMC702 6/18/2009

Contact Information

Applicant

Alex Macon
[email protected]385-200-1617Fax: 408-904-7556

Non-Technical Contact

MET LaboratoriesJennifer Sanchez
[email protected]4082074785

Test Firm

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INCGreg Kovolenko
[email protected]4108444071Fax: 4439299462

Technical Specifications

#Rule PartsFrequency RangePower Output
115C5.75 GHz - 5.83 GHz373.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 136.9 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The 22dBi dish antenna and 28dBi grid antenna are for point-to-point applications only.

Other Applications from Ubiquiti Inc.

SWX-U7ID

Digital Transmission Radio

Aug 28, 2026

Equipment Class

DTS - Digital Transmission System
SWX-USLGGH

SuperLink Gateway HA

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UTRLR

Digital Transmission Radio

Aug 19, 2026

Equipment Class

DTS - Digital Transmission System
SWX-USLER

Recessed Entry Sensor

Aug 12, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SWX-UVCG6ED

G6 Edge Dome

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System