Ubiquiti Inc.

Application Details

Equipment Class
6ID - 15E 6 GHz Low Power Indoor Access Point
Date of Grant
Nov 24, 2025
Application Purpose
Original Equipment
Equipment Note
Digital Transmission Radio
Frequency Range
5955.00000000 - 7115.00000000
Company
Ubiquiti Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

Maximum Permissible Exposure FCC Part 2 Sections §2.1091 and §2.1093 Test Requirement(s): §15.407(f): U-NII devices are subject to the radio frequency radiation exposure requirements specified in §1.1307(b), §2.1091 and §2.1093 of this chapter, as appropriate. All equipment shall be considered to operate in a “general population/uncontrolled” environment. RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit: EUT’s operating frequencies @ WiFi 2412 – 2462 MHz; UNII-1 5180 – 5240 MHz; UNII-2a 5260 – 5320 MHZ; UNII-2c 5500 – 5720 MHz; UNII-3 5745 – 5825 MHz; UNII-5 5955 – 6415; UNII-6 6435 – 6515; UNII-7 6535 – 6885; UNII-8 6895 – 7115 Limit for Uncontrolled exposure: 1 mW/cm 2 or 10 W/m 2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R 2 or R = √(PG / 4S) where, S = Power Density (mW/cm 2 ) P = Power Input to antenna (mW) G = Antenna Gain (numeric value) R = Distance (cm) Test Results: FCC Frequency (MHz) Con. Pwr. (dBm) Con. Pwr. (mW) Ant. Gain (dBi) Ant. Gain numeric Pwr. Density (mW/cm 2 ) Limit (mW/cm 2 ) Margin Distance (cm) Result 2437* 29.67 926.83 4 2.51 0.30 1.0 -0.70 25 Pass 5240 27.34 542.00 6 3.98 0.28 1.0 -0.72 25 Pass 5320 23.87 243.78 6 3.98 0.12 1.0 -0.88 25 Pass 5500 23.83 241.55 6 3.98 0.12 1.0 -0.88 25 Pass 5745* 27.77 598.41 6 3.98 0.30 1.0 -0.70 25 Pass 6585* 23.32 214.78 6 3.98 0.11 1.0 -0.89 25 Pass *Simultaneous Transmission (Worse case): 0.71 1.0 -0.29 25 Pass The safe distance for SWX-U7PROXW where Power Density is less than the MPE Limit listed above was found to be 25 cm. This device does not perform power tune-ups, therefore the maximum power is used for this analysis. All chains were measured and summed under the guidance of KDB 789033 Section II. E.2. and KDB 662911 D01.

Test Report

U7-Pro-Wall-XG Antenna Datasheet Authorized by: Sony Chayadi Outline •AUT Environment −Instrument Information −Test Method •Antenna Performance −2G Antenna Performances −5G Antenna Performances −6G Antenna Performances AUT Environment Instrument Information Instrument ListModelCalibration DateCalibration Due Date Transfer SwitchingMVG2024/11/132025/11/12 TX AmplificationMVG2024/11/132025/11/12 RX AmplificationMVG2024/11/132025/11/12 Active SwitchingMVG2024/11/132025/11/12 Network AnalyzerR&S ZNB2024/11/132025/11/12 Radiocom TesterAnritsu MT88212024/11/132025/11/12 Full SystemSG24-Standard2024/11/132025/11/12 Calibration Record •Full system calibration, including each instrument, will proceed once per year. •Regular calibration, including efficiency/peak gain consistency check, will proceed with bi-monthly. Test Method Measurement Standard •To fix device on the turntable, and laser positioning the height level in the center of the probe. •Align the chamber coordinate and UI coordinate. •Sampling the antenna pattern according to Phi increment 5º / Theta increment 5º. •Finished 3D data collection along with Theta-175º~Theta175º and Phi0º~Phi180º •Frequency resolution setup depends on the different bands. X Y Z Antenna Performance [U7-Pro-Wall XG] Antenna Performance 2G Working frequency 2400 – 2480 MHz Antenna typePIFA Gain4 dBi Model117-06395 Drawing [U7-Pro-Wall XG] Antenna Performance 5G Working frequency 5150 – 5850 MHz Antenna typePIFA Gain6 dBi Model117-06395 Drawing [U7-Pro-Wall XG] Antenna Performance 6G Working frequency 5925 – 7125 MHz Antenna typePIFA Gain6 dBi Model117-06395 Drawing Manufacturer: Ubiquiti Inc. Address: 685 3 rd Avenue Floor New York, NY 10017 United States

Test Report

427 West 12800 South Draper, UT 84020 Test Report Certification FCC ID SWX-U7PROXW ISED ID 6545A-U7PROXW Equipment Under Test U7-Pro-XG-Wall Test Report Serial Number TR10521_03 Date of Test(s) 18, 22 August; 7 - 8 September; 2, 6 October; 6, 18 November 2025 Report Issue Date 19 November 2025 Test Specification Applicant 47 CFR FCC Part 15, Subpart E RSS-248, Issue 3 (October 2024) Ubiquiti Inc. 685 Third Avenue New York, NY 10017 U.S.A. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR10521_U7-Pro-XG-Wall_FCC_15.407_UNII-5_03 Page 2 of 43 PROPRIETARY Certification of Engineering Report This report has been prepared by Unified Compliance Laboratory (UCL) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart E and RSS-248, Issue 3 (October 2024). This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested with the specifications provided by the manufacturer. Applicant Ubiquiti Inc. Manufacturer Ubiquiti Inc. Brand Name UBIQUITI Model Number U7-Pro-XG-Wall FCC ID SWX-U7PROXW ISED ID 6545A-U7PROXW On this 19 th day of November 2025, I individually and for Unified Compliance Laboratory certify that the statements made in this engineering report are true, complete, and correct to the best of my knowledge and are made in good faith. Unified Compliance laboratory is not responsible for incorrect information provided by the manufacturer. Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government. Unified Compliance Laboratory Written By: Joseph W. Jackson Reviewed By: Kimberly DeBole 427 West 12800 South, Draper, UT 84020 TR10521_U7-Pro-XG-Wall_FCC_15.407_UNII-5_03 Page 3 of 43 PROPRIETARY Revision History Revision Description Date 01 Original Report Release 11/19/2025 02 Added Spurious Plots in Section 5.5 11/20/2025 03 Added FCC’s Registration Number in Section 3.5 11/21/2025 427 West 12800 South, Draper, UT 84020 TR10521_U7-Pro-XG-Wall_FCC_15.407_UNII-5_03 Page 4 of 43 PROPRIETARY Table of Contents 1 Client Information ................................................................................................................................. 5 1.1 Applicant ....................................................................................................................................... 5 1.2 Manufacturer ................................................................................................................................. 5 2 Equipment Under Test (EUT) ............................................................................................................... 6 2.1 Identification of EUT .................................................................................................................... 6 2.2 Description of EUT ....................................................................................................................... 6 2.3 EUT and Support Equipment ........................................................................................................ 7 2.4 Interface Ports on EUT ................................................................................................................. 7 2.5 Operating Environment ................................................................................................................. 8 2.6 Operating Modes ........................................................................................................................... 8 2.7 EUT Exercise Software ................................................................................................................. 8 2.8 Block Diagram of Test Configuration .......................................................................................... 9 2.9 Modification Incorporated/Special Accessories on EUT .............................................................. 9 2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard .................... 9 3 Test Specification, Method and Procedures .......................................................................................... 9 3.1 Test Specification .......................................................................................................................... 9 3.2 Methods & Procedures ................................................................................................................ 10 3.3 FCC Part 15, Subpart E ............................................................................................................... 10 3.4 Results ......................................................................................................................................... 10 3.5 Test Location .............................................................................................................................. 11 4 Test Equipment ................................................................................................................................... 12 4.1 Conducted Emissions at Mains Ports .......................................................................................... 12 4.2 Direct Connect at the Antenna Port Tests ................................................................................... 12 4.3 Radiated Emissions ..................................................................................................................... 13 4.4 Contention Base Protocol Tests .................................................................................................. 14 4.5 Equipment Calibration ................................................................................................................ 14 …

Text truncated - open the document above for the full version.

Test Report

427 West 12800 South Draper, UT 84020 Test Report Attachment FCC ID SWX-U7PROXW ISED ID 6545A-U7PROXW Equipment Under Test U7-Pro-XG-Wall Test Report Serial Number TR10521_01 Date of Tests 7 - 8 September; 6 November 2025 Report Issue Date 19 November 2025 Test Personnel Testing performed by Evan Hartzell Test Location Testing was performed at the Unified Compliance Laboratory located at 427 West 12800 South, Draper, UT 84020. Unified Compliance Laboratory is accredited by National Voluntary Laboratory Accreditation Program (NVLAP); NVLAP Code 600241-0 which is effective until 30 June 2026. This site has also been registered with Innovations, Science and Economic Development (ISED) department as was accepted under Appendix B, Phase 1 procedures of the APEC Tel MRA for Canadian recognition. ISED No.: 25346, effective until 30 June 2026. Unified Compliance Laboratory has been assigned Conformity Assessment Number US0223 by ISED and MRA US5037. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR10521_U7-Pro-XG-Wall_FCC_15.407_UNII-5_Annex Page 2 of 100 PROPRIETARY 1 RF Conducted UNII-5 NOTE: The first channel contains the equipment setting table(s), if subsequent channels do not have an equipment setting table(s) then the equipment setting table(s) is the same as the first channel. 1.1 EHT Mode 1.1.1 Summary Test Frequency (MHz) Nominal Bandwidth (MHz) Result Emission Bandwidth 26 dB 5955.000 20.000000 PASS RF output power 5955.000 20.000000 PASS In-Band Emissions 5955.000 20.000000 PASS Occupied Channel Bandwidth 99% 5955.000 20.000000 PASS Frequency Stability 5955.000 20.000000 PASS Emission Bandwidth 26 dB 6195.000 20.000000 PASS In-Band Emissions 6195.000 20.000000 PASS Occupied Channel Bandwidth 99% 6195.000 20.000000 PASS Emission Bandwidth 26 dB 6415.000 20.000000 PASS In-Band Emissions 6415.000 20.000000 PASS Occupied Channel Bandwidth 99% 6415.000 20.000000 PASS Emission Bandwidth 26 dB 5965.000 40.000000 PASS In-Band Emissions 5965.000 40.000000 PASS Occupied Channel Bandwidth 99% 5965.000 40.000000 PASS Emission Bandwidth 26 dB 6205.000 40.000000 PASS In-Band Emissions 6205.000 40.000000 PASS Occupied Channel Bandwidth 99% 6205.000 40.000000 PASS Emission Bandwidth 26 dB 6405.000 40.000000 PASS In-Band Emissions 6405.000 40.000000 PASS Occupied Channel Bandwidth 99% 6405.000 40.000000 PASS Emission Bandwidth 26 dB 5985.000 80.000000 PASS In-Band Emissions 5985.000 80.000000 PASS Occupied Channel Bandwidth 99% 5985.000 80.000000 PASS Emission Bandwidth 26 dB 6225.000 80.000000 PASS In-Band Emissions 6225.000 80.000000 PASS Occupied Channel Bandwidth 99% 6225.000 80.000000 PASS Emission Bandwidth 26 dB 6385.000 80.000000 PASS In-Band Emissions 6385.000 80.000000 PASS Occupied Channel Bandwidth 99% 6385.000 80.000000 PASS Emission Bandwidth 26 dB 6025.000 160.000000 PASS In-Band Emissions 6025.000 160.000000 PASS Occupied Channel Bandwidth 99% 6025.000 160.000000 PASS Tx Spurious Emission 6025.000 160.000000 PASS Emissions in restricted frequency bands (Average) 6025.000 160.000000 PASS Emissions in restricted frequency bands (Peak) 6025.000 160.000000 PASS Emission Bandwidth 26 dB 6185.000 160.000000 PASS In-Band Emissions 6185.000 160.000000 PASS Occupied Channel Bandwidth 99% 6185.000 160.000000 PASS Tx Spurious Emission 6185.000 160.000000 PASS Emissions in restricted frequency bands (Average) 6185.000 160.000000 PASS Emissions in restricted frequency bands (Peak) 6185.000 160.000000 PASS Emission Bandwidth 26 dB 6325.000 160.000000 PASS In-Band Emissions 6325.000 160.000000 PASS Occupied Channel Bandwidth 99% 6325.000 160.000000 PASS 427 West 12800 South, Draper, UT 84020 TR10521_U7-Pro-XG-Wall_FCC_15.407_UNII-5_Annex Page 3 of 100 PROPRIETARY Tx Spurious Emission 6325.000 160.000000 PASS Emissions in restricted frequency bands (Average) 6325.000 160.000000 PASS Emissions in restricted frequency bands (Peak) 6325.000 160.000000 PASS In-Band Emissions 6265.000 320.000000 PASS Occupied Channel Bandwidth 99% 6265.000 320.000000 PASS Tx Spurious Emission 6265.000 320.000000 PASS Emissions in restricted frequency bands (Average) 6265.000 320.000000 PASS Emissions in restricted frequency bands (Peak) 6265.000 320.000000 PASS Emission Bandwidth 26 dB (5955 MHz; 24.000 dBm; 20 MHz) 26 dB Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Limit Min BE L (MHz) 5955.000000 23.300000 --- 320.000000 5943.550000 --- DUT Frequency (MHz) Band Edge Right (MHz) Limit Max BE R (MHz) Max Level (dBm) Result 5955.000000 5966.850000 --- -5.8 PASS Bandwidth Le ve l in d Bm 427 West 12800 South, Draper, UT 84020 TR10521_U7-Pro-XG-Wall_FCC_15.407_UNII-5_Annex Page 4 of 100 PROPRIETARY Measurement Setting Instrument Value Target Value Start Frequency 5.92500 GHz 5.92500 GHz Stop Frequency 5.98500 GHz 5.98500 GHz Span 60.000 MHz 60.000 MHz RBW 200.000 kHz ~ 200.000 kHz VBW 1.000 MHz >= 600.000 kHz SweepPoints 600 ~ 600 Sweeptime 37.969 μs AUTO Reference Level 10.000 dBm 10.000 dBm Attenuation 30.000 dB AUTO Detector MaxPeak MaxPeak SweepCount 200 200 Filter 3 dB 3 dB Trace Mode Max Hold Max Hold Sweeptype FFT AUTO Preamp off off RF output power (5955 MHz; 24.000 dBm; 20 MHz) Result DUT Frequency (MHz) Gated EIRP (dBm) Limit Max (dBm) Gated RMS (dBm) DutyCycle (%) Result 5955.000000 10.7 24.0 10.7 99.721 PASS OSP PowerMeter settings Setting Instrument Value Target Value Measurement Time 1.000 s 1.000 s Points 1000000 1000000 Time resolution 1.000 μs 1.000 μs 427 West 12800 South, Draper, UT 84020 TR10521_U7-Pro-XG-Wall_FCC_15.407_UNII-5_Annex Page 5 of 100 PROPRIETARY In-Band Emissions (5955 MHz; 24.000 dBm; 20 MHz) Result DUT Frequency (MHz) Result 5955.000000 PASS Inband Peak Frequency (MHz) Level (dBm) 5963.650000 -6.7 Measurements Frequency (MHz) Level (dBm) Margin (dB) Limit (dBm) Result 5963.650000 -6.7 0.0 -6.7 PASS 5963.750000 -6.7 0.0 -6.7 PASS 5963.050000 -6.8 0.1 -6.7 PASS 5962.950000 -6.8 0.1 -6.7 PASS 5963.550000 -6.9 0.2 -6.7 PASS …

Text truncated - open the document above for the full version.

Test Report

427 West 12800 South Draper, UT 84020 Test Report Certification FCC ID SWX-U7PROXW ISED ID 6545A-U7PROXW Equipment Under Test U7-Pro-XG-Wall Test Report Serial Number TR10522_03 Date of Test(s) 18, 22 August; 8 September; 7 - 8 October; 6, 18 November 2025 Report Issue Date 19 November 2025 Test Specification Applicant 47 CFR FCC Part 15, Subpart E RSS-248, Issue 3 (October 2024) Ubiquiti Inc. 685 Third Avenue New York, NY 10017 U.S.A. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR10522_U7-Pro-XG-Wall_FCC_15.407_UNII-6_03 Page 2 of 39 PROPRIETARY Certification of Engineering Report This report has been prepared by Unified Compliance Laboratory (UCL) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart E and RSS-248, Issue 3 (October 2024). This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested with the specifications provided by the manufacturer. Applicant Ubiquiti Inc. Manufacturer Ubiquiti Inc. Brand Name UBIQUITI Model Number U7-Pro-XG-Wall FCC ID SWX-U7PROXW ISED ID 6545A-U7PROXW On this 19 th day of Novemebr 2025, I individually and for Unified Compliance Laboratory certify that the statements made in this engineering report are true, complete, and correct to the best of my knowledge and are made in good faith. Unified Compliance laboratory is not responsible for incorrect information provided by the manufacturer. Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government. Unified Compliance Laboratory Written By: Joseph W. Jackson Reviewed By: Kimberly DeBole 427 West 12800 South, Draper, UT 84020 TR10522_U7-Pro-XG-Wall_FCC_15.407_UNII-6_03 Page 3 of 39 PROPRIETARY Revision History Revision Description Date 01 Original Report Release 11/19/2025 02 Added Spurious Plots in Section 5.5 11/20/2025 03 Added FCC’s Registration Number in Section 3.5 11/21/2025 427 West 12800 South, Draper, UT 84020 TR10522_U7-Pro-XG-Wall_FCC_15.407_UNII-6_03 Page 4 of 39 PROPRIETARY Table of Contents 1 Client Information ................................................................................................................................. 5 1.1 Applicant ....................................................................................................................................... 5 1.2 Manufacturer ................................................................................................................................. 5 2 Equipment Under Test (EUT) ............................................................................................................... 6 2.1 Identification of EUT .................................................................................................................... 6 2.2 Description of EUT ....................................................................................................................... 6 2.3 EUT and Support Equipment ........................................................................................................ 7 2.4 Interface Ports on EUT ................................................................................................................. 7 2.5 Operating Environment ................................................................................................................. 7 2.6 Operating Modes ........................................................................................................................... 8 2.7 EUT Exercise Software ................................................................................................................. 8 2.8 Block Diagram of Test Configuration .......................................................................................... 8 2.9 Modification Incorporated/Special Accessories on EUT .............................................................. 8 2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard .................... 8 3 Test Specification, Method and Procedures .......................................................................................... 9 3.1 Test Specification .......................................................................................................................... 9 3.2 Methods & Procedures .................................................................................................................. 9 3.3 FCC Part 15, Subpart E ................................................................................................................. 9 3.4 Results ........................................................................................................................................... 9 3.5 Test Location .............................................................................................................................. 10 4 Test Equipment ................................................................................................................................... 11 4.1 Conducted Emissions at Mains Ports .......................................................................................... 11 4.2 Direct Connect at the Antenna Port Tests ................................................................................... 11 4.3 Radiated Emissions ..................................................................................................................... 12 4.4 Contention Base Protocol Tests .................................................................................................. 13 4.5 Equipment Calibration ................................................................................................................ 13 …

Text truncated - open the document above for the full version.

Test Report

427 West 12800 South Draper, UT 84020 Test Report Attachment FCC ID SWX-U7PROXW ISED ID 6545A-U7PROXW Equipment Under Test U7-Pro-XG-Wall Test Report Serial Number TR10522_01 Date of Tests 8 September; 6 November 2025 Report Issue Date 19 November 2025 Test Personnel Testing performed by Evan Hartzell Test Location Testing was performed at the Unified Compliance Laboratory located at 427 West 12800 South, Draper, UT 84020. Unified Compliance Laboratory is accredited by National Voluntary Laboratory Accreditation Program (NVLAP); NVLAP Code 600241-0 which is effective until 30 June 2026. This site has also been registered with Innovations, Science and Economic Development (ISED) department as was accepted under Appendix B, Phase 1 procedures of the APEC Tel MRA for Canadian recognition. ISED No.: 25346, effective until 30 June 2026. Unified Compliance Laboratory has been assigned Conformity Assessment Number US0223 by ISED and MRA US5037. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR10522_U7-Pro-XG-Wall_FCC_15.407_UNII-6_Annex Page 2 of 53 PROPRIETARY 1 RF Conducted UNII-6 NOTE: The first channel contains the equipment setting table(s), if subsequent channels do not have an equipment setting table(s) then the equipment setting table(s) is the same as the first channel. 1.1 EHT Mode 1.1.1 Summary Test Frequency (MHz) Nominal Bandwidth (MHz) Result Emission Bandwidth 26 dB 6435.000 20.000000 PASS RF output power 6435.000 20.000000 PASS In-Band Emissions 6435.000 20.000000 PASS Occupied Channel Bandwidth 99% 6435.000 20.000000 PASS Frequency Stability 6435.000 20.000000 PASS Emission Bandwidth 26 dB 6475.000 20.000000 PASS In-Band Emissions 6475.000 20.000000 PASS Occupied Channel Bandwidth 99% 6475.000 20.000000 PASS Emission Bandwidth 26 dB 6515.000 20.000000 PASS In-Band Emissions 6515.000 20.000000 PASS Occupied Channel Bandwidth 99% 6515.000 20.000000 PASS Emission Bandwidth 26 dB 6445.000 40.000000 PASS In-Band Emissions 6445.000 40.000000 PASS Occupied Channel Bandwidth 99% 6445.000 40.000000 PASS Emission Bandwidth 26 dB 6485.000 40.000000 PASS In-Band Emissions 6485.000 40.000000 PASS Occupied Channel Bandwidth 99% 6485.000 40.000000 PASS Emission Bandwidth 26 dB 6465.000 80.000000 PASS In-Band Emissions 6465.000 80.000000 PASS Occupied Channel Bandwidth 99% 6465.000 80.000000 PASS Emission Bandwidth 26 dB 6505.000 160.000000 PASS In-Band Emissions 6505.000 160.000000 PASS Occupied Channel Bandwidth 99% 6505.000 160.000000 PASS Tx Spurious Emission 6505.000 160.000000 PASS Emissions in restricted frequency bands (Average) 6505.000 160.000000 PASS Emissions in restricted frequency bands (Peak) 6505.000 160.000000 PASS Emission Bandwidth 26 dB (6435 MHz; 24.000 dBm; 20 MHz) 26 dB Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Limit Min BE L (MHz) 6435.000000 23.300000 --- 320.000000 6423.450000 --- DUT Frequency (MHz) Band Edge Right (MHz) Limit Max BE R (MHz) Max Level (dBm) Result 6435.000000 6446.750000 --- -4.8 PASS 427 West 12800 South, Draper, UT 84020 TR10522_U7-Pro-XG-Wall_FCC_15.407_UNII-6_Annex Page 3 of 53 PROPRIETARY Bandwidth Measurement Setting Instrument Value Target Value Start Frequency 6.40500 GHz 6.40500 GHz Stop Frequency 6.46500 GHz 6.46500 GHz Span 60.000 MHz 60.000 MHz RBW 200.000 kHz ~ 200.000 kHz VBW 1.000 MHz >= 600.000 kHz SweepPoints 600 ~ 600 Sweeptime 37.969 μs AUTO Reference Level 10.000 dBm 10.000 dBm Le ve l in d Bm 427 West 12800 South, Draper, UT 84020 TR10522_U7-Pro-XG-Wall_FCC_15.407_UNII-6_Annex Page 4 of 53 PROPRIETARY Attenuation 30.000 dB AUTO Detector MaxPeak MaxPeak SweepCount 200 200 Filter 3 dB 3 dB Trace Mode Max Hold Max Hold Sweeptype FFT AUTO Preamp off off RF output power (6435 MHz; 24.000 dBm; 20 MHz) Result DUT Frequency (MHz) Gated EIRP (dBm) Limit Max (dBm) Gated RMS (dBm) DutyCycle (%) Result 6435.000000 12.4 24.0 12.4 99.721 PASS OSP PowerMeter settings Setting Instrument Value Target Value Measurement Time 1.000 s 1.000 s Points 1000000 1000000 Time resolution 1.000 μs 1.000 μs In-Band Emissions (6435 MHz; 24.000 dBm; 20 MHz) Result DUT Frequency (MHz) Result 6435.000000 PASS Inband Peak Frequency (MHz) Level (dBm) 6427.250000 -7.0 Measurements Frequency (MHz) Level (dBm) Margin (dB) Limit (dBm) Result 6427.650000 -7.1 0.0 -7.0 PASS 6431.150000 -7.1 0.0 -7.0 PASS 6427.550000 -7.1 0.1 -7.0 PASS 6426.350000 -7.2 0.1 -7.0 PASS 6430.750000 -7.2 0.2 -7.0 PASS 6430.450000 -7.3 0.2 -7.0 PASS 6429.250000 -7.3 0.2 -7.0 PASS 6436.750000 -7.3 0.2 -7.0 PASS 6428.450000 -7.3 0.2 -7.0 PASS 6436.650000 -7.3 0.2 -7.0 PASS 6428.350000 -7.3 0.3 -7.0 PASS 6438.250000 -7.3 0.3 -7.0 PASS 6427.950000 -7.4 0.3 -7.0 PASS 6429.150000 -7.4 0.3 -7.0 PASS 6431.650000 -7.4 0.4 -7.0 PASS 427 West 12800 South, Draper, UT 84020 TR10522_U7-Pro-XG-Wall_FCC_15.407_UNII-6_Annex Page 5 of 53 PROPRIETARY Measurement 1 Setting Instrument Value Target Value Start Frequency 6.38500 GHz 6.38500 GHz Stop Frequency 6.48500 GHz 6.48500 GHz Span 100.000 MHz 100.000 MHz RBW 200.000 kHz ~ 200.000 kHz VBW 500.000 kHz ~ 600.000 kHz SweepPoints 1000 ~ 1000 Sweeptime 1.050 ms AUTO Reference Level 0.000 dBm 0.000 dBm Attenuation 20.000 dB 20.000 dB Detector RMS RMS SweepCount 100 100 Filter 3 dB 3 dB Trace Mode Average Power Average Power Sweeptype Sweep Sweep Preamp off off Occupied Channel Bandwidth 99% (6435 MHz; 24.000 dBm; 20 MHz) 99 % Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Limit Min BE L (MHz) 6435.000000 19.250000 --- 320.000000 6425.375000 5925.000000 DUT Frequency (MHz) Band Edge Right (MHz) Limit Max BE R (MHz) Result 6435.000000 6444.625000 7125.000000 PASS Le ve l in d Bm 427 West 12800 South, Draper, UT 84020 TR10522_U7-Pro-XG-Wall_FCC_15.407_UNII-6_Annex Page 6 of 53 PROPRIETARY Bandwidth Measurement Setting Instrument Value Target Value Start Frequency 6.41500 GHz 6.41500 GHz Stop Frequency 6.45500 GHz 6.45500 GHz Span 40.000 MHz 40.000…

Text truncated - open the document above for the full version.

Test Report

427 West 12800 South Draper, UT 84020 Test Report Certification FCC ID SWX-U7PROXW ISED ID 6545A-U7PROXW Equipment Under Test U7-Pro-XG-Wall Test Report Serial Number TR10523_03 Date of Test(s) 19, 22 August; 8 September; 8 October; 6, 18 November 2025 Report Issue Date 19 November 2025 Test Specification Applicant 47 CFR FCC Part 15, Subpart E RSS-248, Issue 3 (October 2024) Ubiquiti Inc. 685 Third Avenue New York, NY 10017 U.S.A. NVLAP LAB CODE 600241-0 427 West 12800 South, Draper, UT 84020 TR10523_U7-Pro-XG-Wall_FCC_15.407_UNII-7_03 Page 2 of 41 PROPRIETARY Certification of Engineering Report This report has been prepared by Unified Compliance Laboratory (UCL) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart E and RSS-248, Issue 3 (October 2024). This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested with the specifications provided by the manufacturer. Applicant Ubiquiti Inc. Manufacturer Ubiquiti Inc. Brand Name UBIQUITI Model Number U7-Pro-XG-Wall FCC ID SWX-U7PROXW ISED ID 6545A-U7PROXW On this 19 th day of November 2025, I individually and for Unified Compliance Laboratory certify that the statements made in this engineering report are true, complete and correct to the best of my knowledge and are made in good faith. Unified Compliance laboratory is not responsible for incorrect information provided by the manufacturer. Although NVLAP has accredited the Unified Compliance Laboratory testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government. Unified Compliance Laboratory Written By: Joseph W. Jackson Reviewed By: Kimberly DeBole 427 West 12800 South, Draper, UT 84020 TR10523_U7-Pro-XG-Wall_…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alex Macon
[email protected]Fax: 408-904-7556

Test Firm

Unified Compliance LaboratoryClay Allred
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.96 GHz - 7.12 GHz855.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is in eirp. This device must be installed and operated so as to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20 , 40, 80, 160 and 320 MHz modes. The operation of this device will not be allowed on oil platforms, cars, trains, boats, and aircraft, except that this device's operation is permitted in large aircraft while flying above 10,000 feet. Prohibited for control of or communications with unmanned aircraft systems, including drones. Indoor operation only.

Other Applications from Ubiquiti Inc.

SWX-U7ID

Digital Transmission Radio

Aug 28, 2026

Equipment Class

DTS - Digital Transmission System
SWX-USLGGH

SuperLink Gateway HA

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
SWX-UTRLR

Digital Transmission Radio

Aug 19, 2026

Equipment Class

DTS - Digital Transmission System
SWX-USLER

Recessed Entry Sensor

Aug 12, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SWX-UVCG6ED

G6 Edge Dome

Jul 07, 2026

Equipment Class

DTS - Digital Transmission System