FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Cellon Communications Technology (Shenzhen) Co.,Ltd./
  3. T38PCD1650

T38PCD1650GSM/GPRS + Bluetooth + WLAN Mobile phone

Cellon Communications Technology (Shenzhen) Co.,Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 22, 2012
Application Purpose
Original Equipment
Date of Application
Jul 22, 2012
Equipment Note
GSM/GPRS + Bluetooth + WLAN Mobile phone
Frequency Range
2412.00000000 - 2462.00000000
Company
Cellon Communications Technology (Shenzhen) Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

External Photos

ID Label/Location Info

Internal Photos

RF Exposure Info

↗

Test Report

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

IAC Report No.:20120629SAR Page : 1 of 69 Version:1.0 SAR Test Report Product Name : GSM 850/1900 GPRS\W IF I\BT Mobile Phone Model No. : A1650 FCC ID : T38PCD1650 Prepared By: : Inventec Appliances(Pudong) Corporation Address: : No.789 Pu Xing Road,Shanghai,PRC Date of Receipt : 2012.06.29 Date of Test : 2012.06.29-2012.07.04 Report No. : 20120629SAR IAC Report No.:20120629SAR Page : 2 of 69 Version:1.0 Test Report Certification Date of Issue : Jul .10.2012 Report No. : 20120629SAR Product Name : GSM 850/1900 GPRS\W IF I\BT Mobile Phone Model No. : A1650 Trade Name : Claro; PCD Applicant : Cellon Communications Technology (Shenzhen) Co.,Ltd. Address : 13/F, Skyworth C Building, Gaoxin S.Ave1, Hi-Tech Industrial Park, Nanshan District, Standard : FCC 47 CFR Part2 (2.1093) IEEE C95.1-1999 IEEE 1528-2003 FCC OET Bulletin 65 supplement C FCC KDB 648474 D01 v01r05 FCC KDB 941225 D01 v02,FCC KDB 941225 D03 v01 FCC KDB 941225 D04 v01 Test Result : Head: 1.317W/kg(1g); 0.870W/kg(10g) Body: 1.055W/kg(1g); 0.679W/kg(10g) The Test Results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of Inventec Appliances(Pudong) Corporation Documented By : , Jul.10.2012 Judy Ge/Engineer Tested By : , Jul.10.2012 Alice Lee/Engineer Approved By : , Jul.10.2012 Jeff Huang/Director of Operations IAC Report No.:20120629SAR Page : 3 of 69 Version:1.0 TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION ........................................................................................................................................ 4 1.1. APPLICANT ............................................................................................................................................................... 4 1.2. MANUFACTURER ...................................................................................................................................................... 4 1.3. TEST ENVIRONMENT ................................................................................................................................................ 4 2. SAR MEASUREMENT SYSTEM................................................................................................................................ 5 2.1. ALS AS-10U SYSTEM DESC RIPT ION ........................................................................................................................ 5 2.2. ISOTROPIC E-FIE LD PRO BE....................................................................................................................................... 7 2.3. BOUNDARY DETECTION UNIT AND PROBE MOUNTING DEVICE ................................................................................ 8 2.4. DAQ-PAQ (ANALOG TO DIG ITA L ELECTRONICS)....................................................................................................... 9 2.5. AXIS ARTICULATED ROBOT ...................................................................................................................................... 9 2.6. ALS AS UNIVERSAL WO R KS TAT IO N ....................................................................................................................... 10 2.7. UNIVERSAL DEVICE POS IT ION ER............................................................................................................................ 10 2.8. PHONTOM TYPES .................................................................................................................................................... 11 3. TISSUE SIMULATING LIQUID ............................................................................................................................... 12 3.1. THE COMPOSITION OF THE TISSUE SIMULATING LIQ UID .......................................................................................... 12 3.2. TISSUE CALIBRATION RE S U LT ................................................................................................................................ 13 3.3. TISSUE DIELECTRIC PARA METERS FO R HEAD AND BODY PHANTOMS .................................................................... 15 4. SAR MEASUREMENT PROCEDURE ..................................................................................................................... 16 4.1. SAR SYSTEM VA LIDAT ION ..................................................................................................................................... 16 4.2. ARRANGEMENT ASSESSMENT SETUP...................................................................................................................... 25 4.3. SAR MEASUREMENT PROCEDURE ......................................................................................................................... 28 5. SAR EXPOSURE LIMITS.......................................................................................................................................... 29 6. TEST EQUIPMENT LIST .......................................................................................................................................... 30 7. MEASUREMENT UNCERTAINTY .......................................................................................................................... 31 8. TEST RESULTS ........................................................................................................................................................... 33 8.1. SAR TEST RESULT S SUMMA RY .............................................................................................................................. 33 8.2. CONDUCTED POWER(UN IT:DBM) ........................................................................................................................... 37 8.3. SIMULTANEOUS MU LT I-BAND TRANSMISSION ........................................................................................................ 40 8.4. SAR MEASUREMENT DATA .............................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

maggie xu(TA manager)
[email protected]+86-755-86365704Fax: +86-755-86365686

Test Firm

Inventec Appliances(Pudong) CorporationJeff Huang
[email protected]021-54336899Fax: 021-54315010

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz38.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation distance between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory and simultaneous transmission are < 0.10 W/kg, 0.10 W/Kg and 1.33 W/Kg. respectively.

Other Applications from Cellon Communications Technology (Shenzhen) Co.,Ltd.

GSM quad band mobile phone - FCC ID T38C1037 - Cellon Communications Technology (Shenzhen) Co.,Ltd.
T38C1037

GSM quad band mobile phone

Aug 22, 2013

Equipment Class

PCE - PCS Licensed Transmitter held to ear
GSM850/1900 Moblie Phone - FCC ID T38C1021ECL - Cellon Communications Technology (Shenzhen) Co.,Ltd.
T38C1021ECL

GSM850/1900 Moblie Phone

Jul 28, 2013

Equipment Class

PCE - PCS Licensed Transmitter held to ear
GSM/GPRS/WCDMA/BT/WIFI/GPS Mobile Phone - FCC ID T38C8666GP - Cellon Communications Technology (Shenzhen) Co.,Ltd.
T38C8666GP

GSM/GPRS/WCDMA/BT/WIFI/GPS Mobile Phone

Apr 18, 2013

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
WCDMA mobile phone - FCC ID T38C8680EK - Cellon Communications Technology (Shenzhen) Co.,Ltd.
T38C8680EK

WCDMA mobile phone

Mar 26, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
WCDMA mobile phone - FCC ID T38C8680GP - Cellon Communications Technology (Shenzhen) Co.,Ltd.
T38C8680GP

WCDMA mobile phone

Jan 27, 2013

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral