FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Building Automation Products, Inc./
  3. T4F060811TEMP

T4F060811TEMPTemperature Sensor

Building Automation Products, Inc.
Temperature Sensor - FCC ID T4F060811TEMP - Building Automation Products, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 29, 2007
Application Purpose
Original Equipment
Date of Application
Mar 29, 2007
Equipment Note
Temperature Sensor
Frequency Range
418.00000000 - 418.00000000
Company
Building Automation Products, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

750 North Royal Avenue, Gays Mills, WI 54631 USA Tel: +1-608-735-4800 • Fax: +1-608-735-4804 • E-mail:[email protected] • www.bapihvac.com Building Automation Products, Inc. Upgrade to BAPI. 100% Compatible. Guaranteed. Sensors for HVAC/R — Temperature • Humidity • Pressure • Air Quality FCC ID: T4F060811TEMP Installation and Operation Instructions for the Wireless Temperature Sensor. Building Automation Products, Inc. Wireless Temperature Sensor Installation and Operation Instructions Description The Building Automation Products, Inc. Wireless Temperature Sensor, Model BA/WT-D-BB is a battery operated, surface mounted sensor with a 418 MHz radio transmitter. The BA/WT-D-BB is designed to require very little energy; the two internal 3.6 Volt Lithium batteries will operate the sensor for 5 to 8 years in normal operation The BA/WT-D-BB enclosure is designed to mount directly onto a ventilation duct surface or outside wall with the sensing probe being mounted out the back [duct] or out the bottom [outdoor]. The enclosure is supplied with a ‘foam-back’ to minimize vibration and air leakage from a duct or electrical conduit. The enclosure is also provided with additional screws to lock the cover and base together to prevent tampering. The BA/WT-D-BB has one internal push-button which allows for easy training and identification of the transmitter. The push-button is used when linking the transmitter to any Analog Output Module. See BAPI’s INS/OPS for details. The BA/WT-D-BB also has an internally mounted LED. The LED will flash briefly when the sensor transmits a data packet using the 418 MHz radio. This happens roughly about once every 10 seconds orshortly after the use of the push-button. 750 North Royal Avenue, Gays Mills, WI 54631 USA Tel: +1-608-735-4800 • Fax: +1-608-735-4804 • E-mail:[email protected] • www.bapihvac.com Building Automation Products, Inc. Upgrade to BAPI. 100% Compatible. Guaranteed. Sensors for HVAC/R — Temperature • Humidity • Pressure • Air Quality NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. FCC ID: T4F060811TEMP MADE IN USA THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES, OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESERED OPERATION WARNING: Changes or modifications not expressly approved by the manufacturer for compliance could void the user’s authority to operate the equipment.

Cover Letter(s)

Yunus Faziloglu/USA/VERITAS 03/30/2007 11:05 AM To Kathlene McQuaid/USA/VERITAS cc bcc Subject Please PDF CS02578 - Fw: Building Automation Products TCB Questions ----- Forwarded by Yunus Faziloglu/USA/VERITAS on 03/30/2007 11:03 AM ----- "john" <[email protected]> 03/30/2007 10:51 AM To Yunus Faziloglu/USA/VERITAS@VERITAS cc Subject RE: Building Automation Products TCB Questions Yunus, Please find attached the updated files requested and the response to your question 2 below from John Barnes at dbi. "John, What I called the "DC power cable" in the BAPI units is the short cable connecting the card with the battery holders to the main printed circuit board (PCB). Thanks! John Barnes KS4GL, PE, NCE, NCT, ESDC Eng, ESDC Tech, PSE, SM IEEE dBi Corporation 216 Hillsboro Ave Lexington, KY 40511-2105 (859)253-1178 phone (859)252-6128 fax [email protected] http://www.dbicorporation.com/" -----Original Message----- From: [email protected] [mailto:[email protected]] Sent: Thursday, March 29, 2007 10:01 AM To: [email protected] Subject: Building Automation Products TCB Questions Hi John, Please address the following issues for these applications, 1. Labels are missing "ID" after "FCC". Please supply corrected label samples. 2. Pages 7 and 8 of the report mentions DC power cable. If these devices are battery powered please clarify what is referred to as DC power cable. 3. Please supply signed copies of the confidentiality requests by Mr. Novak. 4. Please also supply signed copies of Form 731's. Best Regards, Yunus Faziloglu Curtis-Straus LLC

External Photos

BA/WT-D-BB Exterior Photos top right bottom left BA/WT-D-BB Exterior Photos Front Back

ID Label/Location Info

BA/WT-D-BB Label

Internal Photos

BA/WT-D-BB interiorPhotos Interior top Interior bottom Antenna Interior top under antenna Battery Board Top Interior assembly Battery Board Bottom

Internal Photos

BA/WT-D-BB Antenna

Test Report

dBi Corporation FCC Certification Test Report BAPI BA/WT-D-BB, BA/WTH-D-BB, and BA/BS2-WTH-SO Wireless Sensors Report Number 07dBi001a (this test report replaces test report 07dBi001) Testing Certificate #1985.01 dBi Corporation 07dBi001a Page 2 of 28 ADMINISTRATIVE INFORMATION Historical record: Because dBi Corporation is a testing entity, and not a manufacturer, this original test report of the BA/WT-D-BB, BA/WTH-D-BB, and BA/BS2-WTH-SO wireless sensors is being transmitted to the manufacturer, Building Automation Products, Inc. dBi will keep a copy for its historical records and to satisfy A2LA-Audit requirements. We strongly recommend archiving the units that we tested, to facilitate answering future inquiries regarding these products. Retention of records: The FCC requires the records for a Class A or Class B product to be retained by the responsible party for at least two years after the manufacture of said product has been permanently discontinued. These records should include the original certification or verification test report, quality audit data, and the test procedures used. The European Union requires the Declaration of Conformity (DoC) and all supporting data for a product bearing the CE Marking to be retained, and available for inspection by enforcement authorities, for 10 years after placing the product on the market. Australia and New Zealand require the Declaration of Conformity, test reports, a description of the product, documentation that clearly identifies the product, and paperwork showing the product’s brand name, model number, etc. to be kept for at least five years after the product ceases to be supplied to Australia or New Zealand. Measurement uncertainties: The Lexmark Electromagnetic Compatibility Laboratory (EMC Lab) has a documented calculation of the measurement uncertainties associated with tests performed at the Lexmark site. Ongoing compliance: This report applies only to the samples tested. The manufacturer is responsibility for ensuring that the production models of these wireless sensors comply with the FCC and CE Marking requirements, and continue to comply throughout their manufacturing life. The manufacturer should check any changes to the products that could change their interference profiles. A2LA approval: dBi Corporation has been accredited by the American Association for Laboratory Accreditation (A2LA) for Radiated Emissions and Conducted Emissions, Electromagnetic Interference, and Electrostatic Discharge testing. Copies of our Accreditation Certificate and Scope of Accreditation follow. The Federal Communications Commission (FCC) recognized the Lexmark site as meeting the requirements of section 2.948 of the FCC Rules in a letter dated December 10, 2001. This information is on file with the FCC under Registration No. 949691. Please note: This report may be copied as needed, as long as it is copied in its entirety. dBi Corporation 07dBi001a Page 3 of 28 dBi Corporation 07dBi001a Page 4 of 28 dBi Corporation 07dBi001a Page 5 of 28 dBi Corporation 07dBi001a Page 6 of 28 ADMINISTRATIVE DATA Manufacturer: Building Automation Products, Inc. 750 North Royal Avenue Gays Mills, WI 54631 Appliance/Product: temperature sensor Model/Type Number: BA/WT-D-BB FCC ID: xxxxxxxxxx Rating: 3.6Vdc (Lithium batteries) Appliance/Product: temperature/humidity sensor Model/Type Number: BA/WTH-D-BB FCC ID: xxxxxxxxxx Rating: 3.6Vdc (Lithium batteries) Appliance/Product: temperature/humidity sensor Model/Type Number: BA/BS2-WTH-SO FCC ID: xxxxxxxxxx Rating: 3.6Vdc (Lithium batteries) Suppression Components: see attached sheets. Measurement Equipment used: see attached sheets. Measurements According to, and Sample Units Comply with: FCC 47 CFR Part 15-2006 Report Prepared By: John R. Barnes KS4GL, PE, NCE, NCT, ESDC Eng, ESDC Tech, PSE, SM IEEE Testing Performed by: dBi Corporation 216 Hillsboro Avenue Lexington, KY 40511-2105, USA Testing Performed on: January 19-25, 2007 and March 8, 2007 at: Lexmark International, Inc. Development Lab. Lexington, KY 40550, USA Reviewed and Approved by: John R. Barnes KS4GL, PE, NCE, NCT, ESDC Eng, ESDC Tech, PSE, SM IEEE SIGNED_______________________________DATE__March 8, 2007__ John R. Barnes, PRESIDENT dBi Corp. dBi Corporation 07dBi001a Page 7 of 28 INFORMATION RELATING TO PRODUCT RF INTERFERENCE Appliance/Product: temperature sensor Model/Type Number: BA/WT-D-BB FCC ID: xxxxxxxxxx Rating: 3.6Vdc (Lithium batteries) Suppression Components: Steward 28A0392-0A0 snap-on ferrite on sensor cable. Steward 28A0392-0A0 snap-on ferrite on DC power cable. Clock Frequencies: 8MHz, and 418MHz Cables: none. Electronic Printed Circuit Boards: Transmitter boardP/N 18550 AntennaP/N SM060209 Battery boardP/N SM060811C Size of Product: 127mm x 102mm x 76mm high, with a 290mm x 6mm diameter probe Weight of Product: 450g dBi Corporation 07dBi001a Page 8 of 28 INFORMATION RELATING TO PRODUCT RF INTERFERENCE (cont.) Appliance/Product: temperature/humidity sensor Model/Type Number: BA/WTH-D-BB FCC ID: xxxxxxxxxx Rating: 3.6Vdc (Lithium batteries) Suppression Components: Steward 28A0392-0A0 snap-on ferrite on sensor cable. Steward 28A0392-0A0 snap-on ferrite on DC power cable. Clock Frequencies: 8MHz, and 418MHz Cables: none. Electronic Printed Circuit Boards: Transmitter boardP/N 18550 AntennaP/N SM060209 Battery boardP/N SM060811C Size of Product: 127mm x 102mm x 76mm high, with a 146mm x 20mm diameter probe Weight of Product: 450g dBi Corporation 07dBi001a Page 9 of 28 INFORMATION RELATING TO PRODUCT RF INTERFERENCE (cont.) Appliance/Product: temperature/humidity sensor Model/Type Number: BA/BS2-WTH-SO FCC ID: xxxxxxxxxx Rating: 3.6Vdc (Lithium batteries) Suppression Components: none. Clock Frequencies: 8MHz, and 418MHz Cables: none. Electronic Printed Circuit Boards: Transmitter boardP/N SM061213 AntennaP/N SM060209 Size of Product: 70mm x 25mm x 114mm high Weight of Product: 150g dBi Corporation 07dBi001a Page 10 of 28 Radiated Emissions 30-4,18…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC RADIATED-EMISSIONS & BANDWIDTH TEST CONFIGURATION BA/WT-D-BB, BA/WTH-D-BB, & BA/BS2-WTH-SO 5m SEMIANECHOIC CHAMBER LEXMARK INTERNATIONAL, LEXINGTON KY.

Contact Information

Applicant

Justin P Tracey(Engineering Manager)
[email protected](608)735-4800Fax: (608)735-4804

Test Firm

dBi CorporationJohn Barnes
[email protected]859-253-1178Fax: 859 252 6128

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)418 MHz - 418 MHz-
Confidentiality
Long Term

Other Applications from Building Automation Products, Inc.

2.4 GHz Wi-Fi and BLE Wireless Gateway - FCC ID T4FSM211221 - Building Automation Products, Inc.
T4FSM211221

2.4 GHz Wi-Fi and BLE Wireless Gateway

Jul 10, 2024

Equipment Class

DTS - Digital Transmission System
Temperature sensor for food applications - FCC ID T4FSM061025 - Building Automation Products, Inc.
T4FSM061025

Temperature sensor for food applications

May 03, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Temperature and Relative Humidity Sensor - FCC ID T4F060811RH - Building Automation Products, Inc.
T4F060811RH

Temperature and Relative Humidity Sensor

Mar 29, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Temperature and Relative Humidity Sensor - FCC ID T4F061213RSO - Building Automation Products, Inc.
T4F061213RSO

Temperature and Relative Humidity Sensor

Mar 29, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Temperature and Relative Humidity Sensor - FCC ID T4F16963N16964 - Building Automation Products, Inc.
T4F16963N16964

Temperature and Relative Humidity Sensor

Apr 24, 2006

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter