FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Qixiang Electron Science& Technology Co., Ltd/
  3. T4K-D278U

T4K-D278UDigital DMR and Analog UHF Two Way Radio

Qixiang Electron Science& Technology Co., Ltd
Digital DMR and Analog UHF Two Way Radio - FCC ID T4K-D278U - Qixiang Electron Science& Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Date of Grant
Apr 11, 2023
Application Purpose
Original Equipment
Date of Application
Apr 11, 2023
Equipment Note
Digital DMR and Analog UHF Two Way Radio
Frequency Range
406.12500000 - 479.97500000
Company
Qixiang Electron Science& Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

A1.230325 www.anytone.net AT-D278 Operating Manual Digital DMR and Analog Two Way Radio DMR DIGITAL MOBILE RADIO ASSOCIATION THANK YOU! Thank you very much for choosing our Digital DMR and Analog two way radio. This radio adopts the latest advances in technology, providing reliable communication in today’s demanding communication environment. This radio offers both DMR digital and analog communication, introduces innovative DMR digital processing system to achieve high-audio quality and digital encryption. It offers great stability, and reliability, together with long distance communication as well as fashionable design and compact exterior lines. AT-D278 has Recording, Voice Message, Digital Encryption, Emergency Alarm, Man Down Alarm, Work Alone, Vibration, Analog DTMF, 2TONE, 5TONE, CTCSS/DCS encode/decode functions. » When programming the radio, start by reading the factory software data, and then rewrite this data with your frequency etc., to a new saved code plug, otherwise errors may occur. » You can use the programming cable with a PC to program the frequency, channel type, power etc. your programming must comply with your FCC (or other country) license certification. CONTENTS 1.UNPACKING AND CHECKING THE EQUIPMENT ........................1 1.1 Supplied Accessories .................................................................1 1.2 Standard Accessories ................................................................2 1.3 Optional Accessories .................................................................2 2.BATTERY INFORMATION ..............................................................3 2.1 Charging the Battery Pack .........................................................3 2.2 Charger Supplied .......................................................................3 2.3 Use Caution with the Li-ion Battery ............................................3 2.4 How to Charge ...........................................................................4 2.5 Normal Charging Tips ................................................................5 2.6 How to Store the Battery ............................................................6 3. PREPARATION ..............................................................................7 3.1 Installing / Removing the Battery ...............................................7 3.2 Installing / Removing the Antenna .............................................7 3.3 Installing / Removing the Belt Clip .............................................8 3.4 Installing the Additional Speaker/Microphone (Optional) ...........8 4. Radio Overview.............................................................................9 4.1 Status Indications .....................................................................10 5.BASIC OPERATIONS ....................................................................11 5.1 Power on the Radio ..................................................................11 5.2 Adjust Volume ...........................................................................11 5.3 Select a Zone ............................................................................11 5.4 Select a Channel .......................................................................11 5.5 Receiving and Responding to a Radio Call ..............................11 5.6 Making a Call ............................................................................11 5.7 Monitor ......................................................................................11 5.8 Emergency Alarm .....................................................................12 5.9 Man Down Alarm ......................................................................12 5.10 Battery Voltage Test ...............................................................12 6. PROGRAMMABLE FUNCTIONS ................................................13 7.RESET...........................................................................................17 8.TROUBLE SHOOTING GUIDE .....................................................18 9.ON-LINE SERVICE AND SUPPORT ............................................19 SAFETY ...........................................................................................20 EU DECLARATION OF CONFORMITY ..........................................22 10.TECHNICAL SPECIFICATIONS .................................................23 1 AT-D278 Digital DMR and Analog Two Way Radio 1. UNPACKING AND CHECKING THE EQUIPMENT Unpack the radio carefully. We recommend that you identify the items listed in the following table before discarding the packing materials. If any items are missing or have been damaged during shipment, please contact the carrier or the dealers immediately. 1.1 Supplied Accessories ItemNumberQuantity Antenna1 Li-ion Battery Pack1 Battery Charger 1 AC Adaptor1 Belt Clip1 Hand Strap 1 Instruction Manual 1 2 AT-D278 Digital DMR and Analog Two Way Radio 1. UNPACKING AND CHECKING THE EQUIPMENT 1.2 Standard Accessories Antenna* 1 Li-ion Battery Pack QB-55HL (2600mAh) or QB-55L (1800mAh) Charger QBC-55L AC Adaptor QPS-17 Belt Clip BC-05 Wrist strapInstruction Manual * Note: For frequency band of antenna, please refer to label indicated in the bottom of the antenna. * Note: Car Charger and QBC-55L Charger should be used together. Li-ion Battery Pack QB-55HL (2600mAh) or QB-55L (1800mAh) 1.3 Optional Accessories TYPE C program cable Earphone EJX-023 Car Charger CPL-01 Battery Eliminator CPL-02 Speaker Microphone QHM-024 3 AT-D278 Digital DMR and Analog Two Way Radio 2.2 Charger Supplied 2.3 Use Caution with the Li-ion Battery The Li-ion battery pack is not charged at the factory; please charge it before use. Charging the battery pack for the first time after purchase or extended storage (more than 2 months) may not bring the battery pack to its normal maximum operating capacity. Best operation will require fully charging/ discharging the battery two or three times before the operating capac…

Text truncated - open the document above for the full version.

Cover Letter(s)

Qixiang Electron Science & Technology Co., Ltd. Qixiang Building, Tangxi Industrial Zone, Luojiang, Quanzhou, Fujian, 362011 China Apr.07, 2023 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Explanation of differences between product types FCC ID : T4K-D278U Model Number: AT-D278, T-D278EX, AT-D278U, AT-D278II, AT-D278 PLUS, AT-D279, AT-D279EX, AT-D279U, AT-D279II, DT1000 To Whom It May Concern: We, The Qixiang Electron Science & Technology Co., Ltd. hereby declare that the models are identical except the below: AT-D278 series only model name is different, AT-D279 series only model name is different. AT-D278 series & AT-D279 series both brand name is Anytone, the brand name of D1000 is RADIOCOM. AT-D278 series & D1000 have different cover line design from AT-D279 series. Except for the different above, no other modification is performed. Sincerely, Signature: Contact person: Ken Xu

Cover Letter(s)

Qixiang Electron Science & Technology Co., Ltd. Agent Authorization Company: Qixiang Electron Science & Technology Co., Ltd. Address: Qixiang Building, Tangxi Industrial Zone, Luojiang District, Quanzhou, Fujian, China Product Name: Digital DMR and Analog UHF Two Way Radio Model Number(s): AT-D278, T-D278EX, AT-D278U, AT-D278II, AT-D278 PLUS, AT- D279, AT-D279EX, AT-D279U, AT-D279II, DT1000 Product Description: Digital DMR and Analog UHF Two Way Radio We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2023-03-31 Name: Ken Xu Company: Qixiang Electron Science & Technology Co., Ltd.

Cover Letter(s)

Qixiang Electron Science & Technology Co., Ltd. Qixiang Building, Tangxi Industrial Zone, Luojiang, Quanzhou, Fujian, 362011 China ________________________________________________________________________________ Mar. 30, 2023 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division Subject: Extended Frequencies Justification for Certification of Transmitter with FCC ID: T4K-D278U Dear Sir/Madam, This transmitter was designed to operate in following frequency ranges: 400-480MHz To aid equipment authorization in other countries which accept the United States FCC Grant for Certification, Qixiang Electron Science & Technology Co., Ltd. is requesting that the FCC lists the frequencies 400-480MHz, under FCC Rule Parts 90 on the FCC Grant. Qixiang Electron Science & Technology Co., Ltd. attests that the Digital DMR and Analog UHF Two Way Radio will not be marketed to USA users with the frequency band which is not allowed by the rule part 90. Per the FCC’s KDB634817 guidance, as an alternative to listing the exact frequencies, we acknowledge that it’s a violation of the FCC Rules if this device operates on unauthorized frequencies. Also, equipment programming is the responsibility of Authorized Service Personnel, the Digital DMR and Analog UHF Two Way Radio is complies with 47 CFR Part 90.203(e), in that the operator cannot directly program the transmit frequencies using the normally accessible external controls. Please contact me if you require any additional information. Sincerely Yours, Signature: __________________ (Applicant signature) Ken Xu Frequency Range (MHz) FCC Rule Part 400-406 For Federal 406.1-450 FCC Part 90 450-454 FCC Part 90 456-460 FCC Part 90 460-462.5375 FCC Part 90 462.7375-467.5375 FCC Part 90 467.7375-470 FCC Part 90 470-480 FCC Part 90

Cover Letter(s)

Qixiang Electron Science & Technology Co., Ltd. Qixiang Building, Tangxi Industrial Zone, Luojiang, Quanzhou, Fujian, 362011 China Date: 2023-03-30 FCC Part 90 Letter FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: FCC ID: T4K-D278U Dear Sir/Madam, We, Qixiang Electron Science & Technology Co., Ltd., acknowledge that this device will not be marketed to USA users with the frequency band which is not allowed by rule part 90.and it is a violation of FCC rules if this device is operated on unauthorized frequencies inside the U.S.A. This equipment meets the requirements of the FCC Rules, Parts 90.203(e) and (g), as applicable. Programming of this products transmit frequencies can be performed ONLY by the manufacturer or by service or by maintenance personal. The operator can’t program transmit frequencies using the equipment’s external operation controls. This is to certify that the requirements of 47 CFR Part 90.203(j)(4) and (5) spectrum efficiency are met by the Qixiang Electron Science & Technology Co., Ltd. demonstrated by the tests conducted on the sample radio provided. The tests show that the 4FSK data rate is in accordance with ETSI TS 102 361-1, that is 9600 bits per second in a 12.5 kHz bandwidth to satisfy the data rate requirement of 4800 bits per second per 6.25 kHz of channel bandwidth (7K60F1D emissions). Additionally the radio uses the AMBE+2 half-rate vocoder to compress 60 ms of normal bursts are sent in alternate 30 ms TDMA slots and so comply with the equivalence of one voice channel per 6.25 kHz bandwidth (7K60F1W emission). Additionally the radio also meets the requirement of one voice channel per 12.5 kHz of channel bandwidth for analogue speech (11k0F3E emission). Sincerely Yours, Signature: __________________ (Applicant signature) Ken Xu

External Photos

Report No.: AGC01284221006AP01 Page 1 of 5 EXTERNAL PHOTOS D278 SERIES APPEARANCE D279 SERIES APPEARANCE Report No.: AGC01284221006AP01 Page 2 of 5 All VIEW OF EUT TOP VIEW OF EUT DMR Antenna Report No.: AGC01284221006AP01 Page 3 of 5 BOTTOM VIEW OF EUT FRONT VIEW OF EUT Report No.: AGC01284221006AP01 Page 4 of 5 BACK VIEW OF EUT LEFT VIEW OF EUT Report No.: AGC01284221006AP01 Page 5 of 5 RIGHT VIEW OF EUT ****************************************End of Report*************************************

ID Label/Location Info

FCC ID Label Location 30mm&50mm FCC ID: T4K-D278U

Internal Photos

Report No.: AGC01284221006AP02 Page 1 of 10 INTERNAL PHOTOS OPEN VIEW OF EUT(FIGURE 1) OPEN VIEW OF EUT(FIGURE 2) BT Antenna Report No.: AGC01284221006AP02 Page 2 of 10 OPEN VIEW OF EUT(FIGURE 3) INTERNAL VIEW OF EUT(FIGURE 1) Report No.: AGC01284221006AP02 Page 3 of 10 INTERNAL VIEW OF EUT(FIGURE 2) INTERNAL VIEW OF EUT(FIGURE 3) Report No.: AGC01284221006AP02 Page 4 of 10 INTERNAL VIEW OF EUT(FIGURE 4) INTERNAL VIEW OF EUT(FIGURE 5) Report No.: AGC01284221006AP02 Page 5 of 10 INTERNAL VIEW OF EUT(FIGURE 6) INTERNAL VIEW OF EUT(FIGURE 7) Report No.: AGC01284221006AP02 Page 6 of 10 INTERNAL VIEW OF EUT(FIGURE 8) INTERNAL VIEW OF EUT(FIGURE 9) Report No.: AGC01284221006AP02 Page 7 of 10 INTERNAL VIEW OF EUT(FIGURE 10) INTERNAL VIEW OF EUT(FIGURE 11) Report No.: AGC01284221006AP02 Page 8 of 10 INTERNAL VIEW OF EUT(FIGURE 12) INTERNAL VIEW OF EUT(FIGURE 13) Report No.: AGC01284221006AP02 Page 9 of 10 INTERNAL VIEW OF EUT(FIGURE 14) INTERNAL VIEW OF EUT(FIGURE 15) Report No.: AGC01284221006AP02 Page 10 of 10 INTERNAL VIEW OF EUT(FIGURE 16) ****************************************End of Report*************************************

RF Exposure Info

Page 1 of 47 SAR Test Report Report No.: AGC01284221006FH01 FCC ID : T4K-D278U PRODUCT DESIGNATION : Digital DMR and Analog UHF Two Way Radio BRAND NAME : Anytone, RADIOCOM MODEL NAME : AT-D278, AT-D278EX, AT-D278U, AT-D278II, AT-D278 PLUS, AT-D279, AT-D279EX, AT-D279U, AT-D279II, DT1000 APPLICANT : Qixiang Electron Science & Technology Co., Ltd. DATE OF ISSUE : Feb. 08, 2023 STANDARD(S) : IEEE Std. 1528:2013 FCC 47 CFR Part 2§2.1093 IEEE Std C95.1 ™-2005 IEC 62209-1: 2016 REPORT VERSION : V1.0 Attestation of Global Compliance(Shenzhen) Co., Ltd. Report No.: AGC01284221006FH01 Page 2 of 47 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Feb. 08, 2023 Valid Initial Release Report No.: AGC01284221006FH01 Page 3 of 47 Test Report Applicant Name Qixiang Electron Science & Technology Co., Ltd. Applicant Address Qixiang Building, Tangxi Industrial Zone, Luojiang, Quanzhou, Fujian, 362011 China Manufacturer Name Qixiang Electron Science & Technology Co., Ltd. Manufacturer Address Qixiang Building, Tangxi Industrial Zone, Luojiang, Quanzhou, Fujian, 362011 China Factory Name Qixiang Electron Science & Technology Co., Ltd. Factory Address Qixiang Building, Tangxi Industrial Zone, Luojiang, Quanzhou, Fujian, 362011 China Product Designation Digital DMR and Analog UHF Two Way Radio Brand Name Anytone, RADIOCOM Model Name AT-D278 Series Model AT-D278EX, AT-D278U, AT-D278II, AT-D278 PLUS, AT-D279, AT-D279EX, AT-D279U, AT-D279II, DT1000 Different Description AT-D278 series only model name is different, AT-D279 series only model name is different. AT-D278 series & AT-D279 series both brand name is Anytone, the brand name of D1000 is RADIOCOM. AT-D278 series & D1000 have different cover line design from AT-D279 series. EUT Voltage DC7.4 V Applicable Standard IEEE Std. 1528:2013 FCC 47 CFR Part 2§2.1093 IEEE Std C95.1 ™-2005 IEC 62209-1: 2016 Date of receipt of test item Oct. 18, 2022 Test Date Oct. 24, 2022 Report Template AGCRT- US -PTT/SAR (2021-04-20) Note: The results of testing in this report apply to the product/system which was tested only. Prepared By Thea Huang (Project Engineer) Feb. 08, 2023 Reviewed By Calvin Liu (Reviewer) Feb. 08, 2023 Approved By Max Zhang (Authorized Officer) Feb. 08, 2023 Report No.: AGC01284221006FH01 Page 4 of 47 TABLE OF CONTENTS 1. SUMMARY OF MAXIMUM SAR VALUE ......................................................................................................... 5 2. GENERAL INFORMATION ............................................................................................................................... 6 2.1. EUT DESCRIPTION......................................................................................................................................... 6 3. SAR MEASUREMENT SYSTEM ........................................................................................................................ 7 3.1. THE DASY5 SYSTEM USED FOR PERFORMING COMPLIANCE TESTS CONSISTS OF FOLLOWING ITEMS .................... 7 3.2. DASY5 E-FIELD PROBE ................................................................................................................................. 8 3.3. DATA ACQUISITION ELECTRONICS DESCRIPTION ............................................................................................... 8 3.4. ROBOT .......................................................................................................................................................... 9 3.5. LIGHT BEAM UNIT .......................................................................................................................................... 9 3.6. DEVICE HOLDER .......................................................................................................................................... 10 3.7. MEASUREMENT SERVER ............................................................................................................................... 10 3.8. PHANTOM ................................................................................................................................................. 11 4. SAR MEASUREMENT PROCEDURE ............................................................................................................ 12 4.1. SPECIFIC ABSORPTION RATE (SAR) .............................................................................................................. 12 4.2. SAR MEASUREMENT PROCEDURE ................................................................................................................ 13 5. TISSUE SIMULATING LIQUID ....................................................................................................................... 15 5.1. THE COMPOSITION OF THE TISSUE SIMULATING LIQUID..................................................................................... 15 5.2. TISSUE DIELECTRIC PARAMETERS FOR HEAD AND BODY PHANTOMS ............................................................... 15 5.3. TISSUE CALIBRATION RESULT ....................................................................................................................... 16 6. SAR SYSTEM CHECK PROCEDURE ........................................................................................................... 17 6.1. SAR SYSTEM CHECK PROCEDURES ............................................................................................................. 17 7. EUT TEST POSITION ...................................................................................................................................... 19 7.1. BODY WORN POSITION ................................................................................................................................ 19 8. SAR EXPOSURE LIMITS ............................................................................................................................... 20 9. TEST FACILITY ................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 18 CALIBRATION DATA PROBE CALIBRATION DATA Page 2 of 18 Page 3 of 18 Page 4 of 18 Page 5 of 18 Page 6 of 18 Page 7 of 18 Page 8 of 18 Page 9 of 18 Page 10 of 18 DAE CALIBRATION DATA Page 11 of 18 Page 12 of 18 Page 13 of 18 DIPOLE CALIBRATION DATA Page 14 of 18 Page 15 of 18 Page 16 of 18 Page 17 of 18 Page 18 of 18

Test Report

Page 1 of 60 FCC Test Report Report No.: AGC01284221006FE10 FCC ID : T4K-D278U APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Digital DMR and Analog UHF Two Way Radio BRAND NAME : Anytone, RADIOCOM MODEL NAME : AT-D278, T-D278EX, AT-D278U, AT-D278II, AT-D278 PLUS, AT-D279, AT-D279EX, AT-D279U, AT-D279II, DT1000 APPLICANT : Qixiang Electron Science & Technology Co., Ltd. DATE OF ISSUE : Feb. 08, 2023 STANDARD(S) : FCC Part 90 Rules REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC01284221006FE10 Page 2 of 60 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Feb. 08, 2023 Valid Initial Release Report No.: AGC01284221006FE10 Page 3 of 60 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 5 2. PRODUCT INFORMATION .............................................................................................................................. 6 2.1 PRODUCT TECHNICAL DESCRIPTION ................................................................................................ 6 2.2 TEST FREQUENCY LIST ........................................................................................................................ 7 2.3 RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................. 8 2.4 TEST METHODOLOGY .......................................................................................................................... 8 2.5 CALCULATION OF EMISSION INDICATORS ........................................................................................ 8 2.6 SPECIAL ACCESSORIES ....................................................................................................................... 8 2.7 EQUIPMENT MODIFICATIONS .............................................................................................................. 8 3. TEST ENVIRONMENT ..................................................................................................................................... 9 3.1 ADDRESS OF THE TEST LABORATORY .............................................................................................. 9 3.2 TEST FACILITY ....................................................................................................................................... 9 3.3 ENVIRONMENTAL CONDITIONS........................................................................................................... 9 3.4 MEASUREMENT UNCERTAINTY ........................................................................................................ 10 3.5 LIST OF EQUIPMENTS USED ............................................................................................................. 11 4.SYSTEM TEST CONFIGURATION ................................................................................................................. 12 4.1 EUT CONFIGURATION ......................................................................................................................... 12 4.2 EUT EXERCISE ..................................................................................................................................... 12 4.3 CONFIGURATION OF TESTED SYSTEM ............................................................................................ 12 4.4 EQUIPMENT USED IN TESTED SYSTEM........................................................................................... 12 4.5 SUMMARY OF TEST RESULTS ........................................................................................................... 13 5.DESCRIPTION OF TEST MODES .................................................................................................................. 14 6.FREQUENCY TOLERANCE ........................................................................................................................... 15 6.1 PROVISIONS APPLICABLE .................................................................................................................. 15 6.2 MEASUREMENT PROCEDURE ........................................................................................................... 15 6.3 MEASUREMENT SETUP ...................................................................................................................... 15 6.4 MEASUREMENT RESULTS.................................................................................................................. 16 7. EMISSION BANDWIDTH ............................................................................................................................... 18 7.1 PROVISIONS APPLICABLE .................................................................................................................. 18 7.2 MEASUREMENT PROCEDURE ........................................................................................................... 18 7.3 MEASUREMENT SETUP ...................................................................................................................... 18 7.4 MEASUREMENT RESULTS.................................................................................................................. 19 8. SPURIOUS RATIATED EMISSION ................................................................................................................. 23 8.1 PROVISIONS APPLICABLE .................................................................................................................. 23 8.2 MEASUREMENT PROCEDURE ........................................................................................................... 23 Report No.: AGC01284221006FE10 Page 4 of 60 8.3 MEASUREMENT SETUP ...................................................................................................................... 24 8.4 MEASUREMENT RESULTS....................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: AGC01284221006FE10 Page 36 of 60 Emission Mask [email protected] Emission Mask [email protected] Emission Mask [email protected] Emission Mask [email protected] Emission Mask [email protected] Emission Mask [email protected] Report No.: AGC01284221006FE10 Page 37 of 60 Emission Mask [email protected] Emission Mask [email protected] Emission Mask [email protected] Emission Mask [email protected] Report No.: AGC01284221006FE10 Page 38 of 60 9.MODULATION CHARACTERISTICS 9.1 PROVISIONS APPLICABLE According to FCC§2.1047 and §90.207, for Voice Modulation Communication Equipment, the frequency response of the audio modulation circuit over a range of 100 to 5000Hz shall be measured. 9.2 MEASUREMENT METHOD 9.2.1 Modulation Limit (1). Configure the EUT as shown in figure 1, adjust the audio input for 60% of rated system deviation at 1kHz using this level as a reference (0dB) and vary the input level from –20 to +20dB. Record the frequency deviation obtained as a function of the input level. (2). Repeat step 1 with input frequency changing to 300, 1000, 1500 and 3000Hz in sequence. 9.2.2 Audio Frequency Response (1). Configure the EUT as shown in figure 1. (2). Adjust the audio input for 20% of rated system deviation at 1 kHz using this level as a reference (0 dB). (3). Vary the Audio frequency from 100 Hz to 10 kHz and record the frequency deviation. (4). Audio Frequency Response = 20log10 (Deviation of test frequency/Deviation of 1 kHz reference). 9.3 MEASUREMENT SETUP Report No.: AGC01284221006FE10 Page 39 of 60 9.4 MEASUREMENT RESULTS (A). MODULATION LIMIT: 12.5kHz, Analog modulation, Assigned Frequency:406.125MHz-5W Modulation Level (dB) Peak Freq. Deviation At 300 Hz (kHz) Peak Freq. Deviation At 1000 Hz (kHz) Peak Freq. Deviation At 1500 Hz (kHz) Peak Freq. Deviation At 3000 Hz (kHz) -20 0.19 0.39 0.65 0.86 -15 0.42 0.59 0.77 1.13 -10 0.55 0.66 0.95 1.28 -5 0.57 0.69 1.12 1.36 0 0.62 0.75 1.15 1.46 +5 0.61 0.88 1.21 1.57 +10 0.69 0.85 1.25 1.58 +15 0.71 0.95 1.27 1.78 +20 0.63 0.91 1.28 1.71 Note: All the modes had been tested, but only the worst data recorded in the report. Report No.: AGC01284221006FE10 Page 40 of 60 (B). AUDIO FREQUENCY RESPONSE: Note: All the modes had been tested, but only the worst data recorded in the report. 12.5kHz, Analog modulation, Assigned Frequency:406.125MHz-5W Frequency (Hz) Deviation (kHz) Audio Frequency Response(dB) 100 -- -- 200 -- -- 300 0.16 -13.65 400 0.27 -9.10 500 0.34 -7.10 600 0.42 -5.26 700 0.46 -4.47 800 0.57 -2.61 900 0.61 -2.02 1000 0.77 0.00 1200 0.82 0.55 1400 0.96 1.92 1600 1.03 2.53 1800 1.21 3.93 2000 1.35 4.88 2400 1.46 5.56 2500 1.61 6.41 2800 1.63 6.51 3000 1.83 7.52 Report No.: AGC01284221006FE10 Page 41 of 60 10. MAXIMUMN TRANSMITTER POWER 10.1 PROVISIONS APPLICABLE Per FCC §2.1046. § 90.205: Maximum ERP is dependent upon the station’s antenna HAAT and required service area. 10.2 MEASUREMENT METHOD The RF output of Two-way Radio was conducted to a spectrum analyzer through an appropriate attenuator. In the semi-anechoic chamber, setup as illustrated above the DUT placed on the 0.8m height of Turn Table, rotated the table 45 degree each interval to search the maximum radiation power and receiver antenna shall be rotated vertical and horizontal polarization and moved height from 1m to 4m to find the maximum polar radiated power for each degree interval. The “Read Value” is the spectrum reading of maximum power value. The substitution antenna is substituted for DUT at the same position and signals generator (S.G) export the CW signal to the substitution antenna via a TX cable. The receiver antenna shall be rotated vertical and horizontal polarization and moved height from 1m to 4m to find the maximum radiation power. Record the power level of maximum radiation power from spectrum. So, the Measured substitution value = Ref level of S.G + TX cables loss – Substituted Antenna Gain. EIRP = “Read Value” + Measured substitution value + 2.15. 10.3 MEASUREMENT METHOD Conducted Output Power: Report No.: AGC01284221006FE10 Page 42 of 60 Effective Radiated Power: Radiated Below 1GHz Radiated Above 1 GHz Report No.: AGC01284221006FE10 Page 43 of 60 10.4 MEASUREMENT RESULTS Conducted Power Measurement Results Mode Channel Separati…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ken Xu
[email protected]86-592-22652998Fax: 86-595-22656927

Technical Contact

Qixiang Electron Science & Technology Co., Ltd.
[email protected]

China

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]+86-755-25234088

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
39406.125 MHz - 479.975 MHz4.8753 W7K79F1W1.071 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is rated conducted. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum of 2 inches between the device, including its antenna, and the user's face. The highest reported SAR values for Face held, Body-worn and simultaneous accessory are 5.58W/kg?6.46 W/kg and 6.67 W/kg respectively when operating at 50% duty cycle.

Other Applications from Qixiang Electron Science& Technology Co., Ltd

10 METER AMATEUR RADIO - FCC ID T4K-AT5100 - Qixiang Electron Science& Technology Co., Ltd
T4K-AT5100

10 METER AMATEUR RADIO

Jul 28, 2026

Equipment Class

DTS - Digital Transmission System
HANDHELD TRANSCEIVER - FCC ID T4K-UA1 - Qixiang Electron Science& Technology Co., Ltd
T4K-UA1

HANDHELD TRANSCEIVER

Apr 07, 2026

Equipment Class

CSR - Scanning Receiver
DUAL BAND HANDHELD TRANSCEIVER - FCC ID T4K-UVA1 - Qixiang Electron Science& Technology Co., Ltd
T4K-UVA1

DUAL BAND HANDHELD TRANSCEIVER

Mar 30, 2026

Equipment Class

CSR - Scanning Receiver
CB Radio - FCC ID T4K-AT-505 - Qixiang Electron Science& Technology Co., Ltd
T4K-AT-505

CB Radio

Jan 19, 2026

Equipment Class

JAV - Other Non-Digital SDoC Devices
Multi-Protocol Digital+Analog Handheld Radio - FCC ID T4K-D890UV - Qixiang Electron Science& Technology Co., Ltd
T4K-D890UV

Multi-Protocol Digital+Analog Handheld Radio

Jan 07, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter