FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Qixiang Electron Science& Technology Co., Ltd/
  3. T4K-QZQX289G

T4K-QZQX289GTWO-WAY RADIO

Qixiang Electron Science& Technology Co., Ltd
TWO-WAY RADIO - FCC ID T4K-QZQX289G - Qixiang Electron Science& Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
Date of Grant
Dec 11, 2010
Application Purpose
Original Equipment
Date of Application
Dec 11, 2010
Equipment Note
TWO-WAY RADIO
Frequency Range
400.00000000 - 480.00000000
Company
Qixiang Electron Science& Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

THANK YOU! Thank you very much for choosing our transceiver. transceiver provides you with reliable, clear and efficient communication service. The transceiver introduces innovative DSP (Digital Signal Processing) baseband processing system to achieve high-fidelity voice processing and encryption. It boasts novelty, best stability, great reliability, nice timbre and long distance communication as well as fashionable design and smooth exterior lines. ST-289G is a cost-effective and multi-functional professional transceiver which meets needs of every walk of life. It is convinced that you will be satisfied with this transceiver’s quality and functions. For your full comprehension of the various excellent functions and maintenance, please read the user manual before use. NOTE: When programming the transceiver, read the factory initial data first, then rewrite the frequency and signaling etc., otherwise errors may occur because of different frequency band etc. User Manual Applied to: 289G UHF FM Transceiver VHF FM Transceiver Programming Software: QPS289 SAFETY INFORMATION FOR USER transceiver is excellently designed with advanced technology. Please observe the following precautions to perform your obligation, prevent personal injury and ensure the safety of transceiver usage. Keep the transceiver and accessories away from children.1. Please do not try to open or modify the transceiver without permission, non-professionals process 2. may also cause damage. Please use assorted battery and charger to avoid damage.3. Please use assorted antenna to ensure the communication distance.4. Please do not expose the transceiver to long period of direct sunlight, nor place it close to heat 5. appliances. Please do not put the transceiver in excessively dusty or humid areas.6. Do not use harsh chemicals, cleaning solvents to clean the transceiver.7. Do not transmit without antenna.8. When using this transceiver, we recommend transmitting for 1 minute then receiving for 4 minutes. 9. Continuous transmitting for long time or working in high power will heat the back of the transceiver. Do not place the transceiver’s hot back close to any surface of plastic. If any abnormal odor or smoke detected coming from the transceiver, turn off the power and take 11 . off the battery pack and its case. Then contact local dealers. ATTENTION: All tips above apply to accessories of your transceiver. If any device can not work normally, please contact local dealers. If you use any accessories made by other companies, Company does not guarantee the operability and safety of the transceiver. Professional FM Transceiver I UNPACKING .......................................................................................................................1 Supplied Accessories .........................................................................................................................1 STANDARD ACCESSORIES/OPTIONAL ACCESSORIES ...............................................2 Standard Accessories .........................................................................................................................2 Optional Accessories ..........................................................................................................................2 BATTERY INFORMATION ..................................................................................................3 Charging Operation .............................................................................................................................3 Charger Applied ..................................................................................................................................3 Notice for Charging Battery .................................................................................................................3 How to Charge ....................................................................................................................................4 Normal Charging Tips .........................................................................................................................6 How to Store the Battery .....................................................................................................................6 PREPARATION ...................................................................................................................8 Installing / Removing the Battery ........................................................................................................8 Installing / Removing the Antenna ......................................................................................................8 Installing / Removing the Belt Clip ......................................................................................................9 Installing the Additional Speaker/ Microphone (Optional) ..................................................................9 Installing/ Removing the Hand Strap (Optional) ..................................................................................11 CONTENTS Professional FM Transceiver II GETTING ACQUAINTED ....................................................................................................11 Indicator Status and Beep ..................................................................................................................13 [PF1] & [PF2] Key Default ...................................................................................................................13 BASIC OPERATIONS .........................................................................................................14 Switch on / off Transceiver ..................................................................................................................14 Adjusting Volume ................................................................................................................................14 Channel Selection ................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 2.0 2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Revised wording (current) 1.0 2.0 Sept–25-2007 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 2.0 Qixiang Electron Science & Technology Co.,Ltd November4,2010 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, Qixiang Electron Science & Technology Co.,Ltd.hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): two-way radio(289G,289,289P,3317) , FCC ID: T4K-QZQX289G We affirm t hat between SIEMIC and Qixiang Electron Science & Technology Co.,Ltd, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Client’s signature Client’s name / title: Ken Xu Contact information / address: 0086-595-22652998 /Qixiang Building, Tangxi Industrial Zone, Luojiang District, QuanZhou 362011,Fujian Province,China

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 2.0 2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 1.0 2.0 August – 11 - 2008 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 2.0 Qixiang Electron Science & Technology Co.,Ltd. (2010-12-10) To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: T4K- QZQX289G We hereby request confidential treatment of information accompanying this application as outlined below: - Schematics - Operational Description - Block Diagram - Part List - Tune Up Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature: Client’s name / title: Ken Xu Contact information / address: 0086-595-22652998 /Qixiang Building, Tangxi Industrial Zone, Luojiang, QuanZhou 362011,Fujian Province,China

External Photos

Model: 289G Model: 289G Model: 289G Model: 289 Model: 289 Model: 289P Model: 3317

ID Label/Location Info

Mark location

Internal Photos

Model: 289G Model: 289 Model: 289P Model: 3317

RF Exposure Info

Report No.: RZA2010-0812 TESTING No. L2264 TEST REPORT Product Name Two-Way Radio Model 289G FCC ID T4K-QZQX289G Client Qixiang Electron Science & Technology Co.,Ltd. TA Technology (Shanghai) Co., Ltd. GENERAL SUMMARY Product Name Two-Way Radio Model 289G FCC ID T4K-QZQX289G Report No. RZA2010-0812 Client Qixiang Electron Science & Technology Co.,Ltd. Manufacturer Qixiang Electron Science & Technology Co.,Ltd. Reference Standard(s) IEEE Std C95.1, 1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 KHz to 300 GHz. SUPPLEMENT C Edition 01-01 to OET BULLETIN 65 Edition 97-01 June 2001 including DA 02-1438 June 19, 2002: Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Additional Information for Evaluation Compliance of Mobile and Portable Devices with FCC Limits for Human Exposure to Radiofrequency Emissions. IEEE Std 1528™-2003: IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques. Conclusion This portable wireless equipment has been measured in all cases requested by the relevant standards. Test results in Chapter 7 of this test report are below limits specified in the relevant standards. General Judgment: Pass (Stamp) Date of issue: Nov 26 th , 2010 Comment The test result only responds to the measured sample. Approved by Yang Weizhong Revised by Ling Minbao Performed by Wang Lu TA Technology (Shanghai) Co., Ltd. Test Report Report No. RZA2010-0812 Page 3of 59 TABLE OF CONTENT 1.General Information ..................................................................................................................... 4 1.1.Notes of the test report .........................................................................................................4 1.2.Testing laboratory.................................................................................................................4 1.3.Applicant Information ............................................................................................................5 1.4.Manufacturer Information ......................................................................................................5 1.5.Information of EUT................................................................................................................6 1.6.Test Date ..............................................................................................................................6 2.Operational Conditions during Test .............................................................................................. 7 3.SAR Measurements System Configuration.................................................................................. 8 3.1.SAR Measurement Set-up ....................................................................................................8 3.2.DASY5 E-field Probe System ...............................................................................................9 3.2.1.ET3DV6 Probe Specification .........................................................................................9 3.2.2.E-field Probe Calibration ..............................................................................................10 3.3.Other Test Equipment .........................................................................................................10 3.3.1.Device Holder for Transmitters ....................................................................................10 3.3.2.Phantom...................................................................................................................... 11 3.4.Scanning procedure............................................................................................................ 11 3.5.Data Storage and Evaluation..............................................................................................13 3.5.1.Data Storage................................................................................................................13 3.5.2.Data Evaluation by SEMCAD ......................................................................................13 3.6.System check......................................................................................................................16 3.7.Equivalent Tissues ..............................................................................................................17 4.Laboratory Environment............................................................................................................. 17 5.Charcteristics of the Test ............................................................................................................ 18 5.1.Applicable Limit Regulations...............................................................................................18 5.2.Applicable Measurement Standards...................................................................................18 6.Conducted Output Power Measurement.................................................................................... 19 6.1.Conducted Power Results ..................................................................................................19 7.Test Results ............................................................................................................................... 20 7.1.Dielectric Performance........................................................................................................20 7.2.System Check Results ........................................................................................................20 7.3.Summary of Measurement Results.....................................................................................21 7.4.Conclusion ......................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

ISO/IEC17025Accredited Lab. Report No: FCC 1011040 File reference No: 2010-12-02 Applicant: Qixiang Electron Science & Technology Co.,Ltd. Product: two-way radio Model No: 289G Trademark: N/A Test Standards: FCC Part 90 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4 and FCC Part 90, regulations for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: Dec 02, 2010 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD 5/F,Block 4, Anhua Industrial Zone.,No.8 TaiRan Rd.CheGongMiao,FuTian District, Shenzhen,CHINA. Tel (755) 83448688 Fax (755) 83442996 Report No: 1011040 Page 2 of 55 Date: 2010-12-02 TEST REPORT The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAL. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAL-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAL/AC01:2002 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:1999 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 899988. IC- Registration No.: IC5205A-01 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration IC No.: 5205A-01. Report No: 1011040 Page 3 of 55 Date: 2010-12-02 TEST REPORT The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 4 1.5 Test Duration.................................................................................................... 4 1.6 Test Uncertainty.................................................................................................5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 5 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification............................................................................................. 7 5.0 Power Line Conducted Emission Test...................................................................... 8 6.0 Frequency Tolerance..........................................................................................13 7.0 Emission Bandwidth and Mask............................................................................. 17 8.0 Unwanted Radiation.......................................................................................... 20 9.0 Modualtion Characteristics................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted test View-- Radiated emission test view

Contact Information

Applicant

Ken Xu
[email protected]86-592-22652998Fax: 86-595-22656927

Test Firm

Shenzhen Timeway Testing LaboratoriesJack Chung
[email protected]0755-83448688Fax: 86-755-83442996

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
29400 MHz - 480 MHz5.5 W8K92F3E1.42 ppm
Confidentiality
Long Term
Grant Notes
Listed Output Power is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. Body-worn compliance is limited to the specific belt-clip tested for this device with appropriate spacing as indicated in the filing. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are � Held to face: 5.55 W/kg; Body: 5.589 W/kg accounting for a 50% duty cycle..

Other Applications from Qixiang Electron Science& Technology Co., Ltd

10 METER AMATEUR RADIO - FCC ID T4K-AT5100 - Qixiang Electron Science& Technology Co., Ltd
T4K-AT5100

10 METER AMATEUR RADIO

Jul 28, 2026

Equipment Class

DTS - Digital Transmission System
HANDHELD TRANSCEIVER - FCC ID T4K-UA1 - Qixiang Electron Science& Technology Co., Ltd
T4K-UA1

HANDHELD TRANSCEIVER

Apr 07, 2026

Equipment Class

CSR - Scanning Receiver
DUAL BAND HANDHELD TRANSCEIVER - FCC ID T4K-UVA1 - Qixiang Electron Science& Technology Co., Ltd
T4K-UVA1

DUAL BAND HANDHELD TRANSCEIVER

Mar 30, 2026

Equipment Class

CSR - Scanning Receiver
CB Radio - FCC ID T4K-AT-505 - Qixiang Electron Science& Technology Co., Ltd
T4K-AT-505

CB Radio

Jan 19, 2026

Equipment Class

JAV - Other Non-Digital SDoC Devices
Multi-Protocol Digital+Analog Handheld Radio - FCC ID T4K-D890UV - Qixiang Electron Science& Technology Co., Ltd
T4K-D890UV

Multi-Protocol Digital+Analog Handheld Radio

Jan 07, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter