Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
GmbH Max-Eyth-Straße 16 Telefon: +49 7931 597-0 Kontakt: 97980 Bad Mergentheim Telefax: +49 7931 597-183 [email protected] Deutschland GmbH Max-Eyth-Straße 16 Phone: +49 7931 597-0 Contact: 97980 Bad Mergentheim Fax: +49 7931 597-183 [email protected] Deutschland Appendix B: Supplement for User Manual UL Class I Division 1 UL Classes I, II, III Division 1 Mobile Computer MC 9090 ex RFID / LF MC 9090 ex RFID / HF MC 9090 ex RFID / UHF Type 17(A129(R.../H....... Version 1.00 Document no. 11-A119-7D0001_Supplement Status: 01 October 2009 Technical data subject to change without notice! Table of Contents 2 1 Product Description........................................................................................................................................................4 2 Safety Instructions..........................................................................................................................................................5 2.1 Electromagnetic Fields.....................................................................................................................................5 2.1.1 International ....................................................................................................................................................5 2.1.2 US and Canada...............................................................................................................................................5 2.2 Warnings for Use of Wireless Devices.............................................................................................................6 2.2.1 Radio Frequency Interference Requirements - FCC.......................................................................................6 2.2.2 Radio Frequency Interference Requirements - Canada..................................................................................6 3 Technical Data.................................................................................................................................................................7 3.1 RFID / LF Internal Module................................................................................................................................7 3.1.1 Explosion Protection .......................................................................................................................................7 3.1.2 General Data...................................................................................................................................................7 3.1.3 Radio Data Transmission RFID / LF Internal Module......................................................................................7 3.1.4 Standards Supported by Firmware..................................................................................................................8 3.2 RFID / LF External Module...............................................................................................................................9 3.2.1 Explosion Protection .......................................................................................................................................9 3.2.2 General Data...................................................................................................................................................9 3.2.3 Radio Data Transmission RFID / LF External Module.....................................................................................9 3.2.4 Standards Supported by Software ................................................................................................................10 3.3 RFID / HF External Module............................................................................................................................10 3.3.1 Explosion Protection .....................................................................................................................................10 3.3.2 General Data.................................................................................................................................................10 3.3.3 Radio Data Transmission RFID / HF External Module..................................................................................11 3.3.4 Standards Supported by Firmware................................................................................................................11 3.4 RFID / UHF External Modul............................................................................................................................12 3.4.1 Explosion Protection .....................................................................................................................................12 3.4.2 General Data.................................................................................................................................................12 3.4.3 Radio Data Transmission RFID / UHF External Module ...............................................................................12 3.5 RFID / UHF External Module + External Antenna..........................................................................................13 3.5.1 Explosion Protection .....................................................................................................................................13 3.5.2 General Data.................................................................................................................................................13 3.5.3 Radio Data Transmission RFID / UHF External Module + External Antenna................................................13 3.6 Notes re. Directives and Standards, Marking and In-Process Inspections.....................................................14 3.6.1 Product Marking Mobile Computer MC 9090 ex RFID / LF internal (UL Class I Division 1).............................14 3.6.2 Product Marking Mobile Computer MC 9090 ex RFID / LF / HF / UHF external…
Text truncated - open the document above for the full version.
Request for Confidentiality PHOENIX TESTLAB GmbH Date: June 24, 2010 Product Certification Königswinkel 10 D 32825 Blomberg RE: Certification Application FCC ID: TBURFID-LF Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: • Schematics • Block Diagram • Parts List • Technical Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application. Thank you for your attention in this matter. Applicant’s Company : TÜV SÜD SENTON GmbH address : Auessere Fruehlingstrasse 45, D-94315 Straubing Signature : Johann Roidt Job Title and Dept. : Technical Director
Attn: Reviewing Engineer RE: PART 15 UNLICENSED MODULAR TRANSMITTER APPROVAL To Whom It May Concern: We, Bartec GmbH , hereby request part 15 limited unlicensed modular transmitter approval for our device: Brand name: BARTEC Model name: MC9090 RFID-LF extern FCC ID: TBURFID-LF In FCC Public Notice DA 00-1407 released June 26, 2000 there are eight numbered requirements: that our device complies as stated below: 1. The modular transmitter must have its own shielding. Not c ompliant, the R FID t ransceiver m odule do es n ot ha ve a n o wn s hielding; but t his m odule will only be integrated into dedicated host devices under the control of the Grantee himself, s o that compliance to the Part 15 emission limits is always assured. 2. The modular transmitter must have buffered modulation/data inputs Compliant; please refer to schematics (U2 / MSP430F1232). 3. The modular transmitter must have its own power supply regulation Compliant; please refer to schematics (U3, U5, U10 / LT1962). 4. The modular transmitter must comply with the antenna requirements of Section 15.203 and 15.204c Compliant, this RFID transceiver module is equipped with a fixed connected loop antenna that will be placed inside the dedicated host devices. 5. The modular transmitter must be tested in a stand-alone configuration Not compliant; due to the fact that this RFID transceiver does not have an own shielding, this module is tested inside the dedicated host device as documented in this filing. 6. The modular transmitter must be labelled with its own FCC ID number Compliant, t his R FID t ransceiver i s l abled with i ts o wn F CC I D as doc umented w ith t he l able location info exhibit. I n addition, t he host de vice, into which this m odule i s i ntegrated i s labled with t he a uxillary l able “Contains TX FCC ID: TBURFID-LF” 7. The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. Compliant, this RFID transceiver module complies with the appropriate FCC regulations as documented in the test report(s) 8. The modular transmitter must comply with any applicable RF exposure requirements. N/A, this RFID transceiver module subject to §15.209 is exempted from the RF Exposure requirements. Johann Roidt TÜV SÜD SENTON GmbH
TBURFIDLF TBURFIDLF
TBURFIDLF
TBURFIDLF TBURFIDLF
Amendment to Test Report No. 70751-00483-1 Applicant: TECTUS Transponder Technology GmbH Type of equipment: Handheld RFID Reader Type designation: MC 9090 RFID LF extern Test standards: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205, 15.207, 15.209 Industry Canada Radio Standards Specifications RSS-Gen Issue 2, Section 7.2.2 and RSS-210 Issue 7, Sections 2.2, 2.6 (Category I Equipment) July 5, 2010 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 2 of 16 Page(s) EUT flat on table (P1) TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 3 of 16 Page(s) EUT flat on table (P1) Horizontal Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 4 of 16 Page(s) EUT flat on table (P1) Vertical Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 5 of 16 Page(s) EUT on long side (P2) TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 6 of 16 Page(s) EUT on long side (P2) Horizontal Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 7 of 16 Page(s) EUT on long side (P2) Vertical Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 8 of 16 Page(s) EUT in upright position (P3) TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 9 of 16 Page(s) EUT in upright position (P3) Horizontal Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 10 of 16 Page(s) EUT in upright position (P3) Vertical Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 11 of 16 Page(s) WLAN + Bluetooth -Horizontal Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 12 of 16 Page(s) WLAN + Bluetooth – Vertical Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 13 of 16 Page(s) WLAN + Bluetooth – Horizontal Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 14 of 16 Page(s) # WLAN + Bluetooth – Vertical Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 15 of 16 Page(s) WLAN + Bluetooth – Horizontal Polarisation TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Amendment to Test Report No. 70751-00483-1 Page 16 of 16 Page(s) WLAN + Bluetooth – Vertical Polarisation
Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 70751-00483-1 (Edition 3) Page 1 of 55 Pages Prüfbericht / Test Report Nr. / No. 70751-00483-1 (Edition 3) Applicant: TECTUS Transponder Technology GmbH Type of equipment: Handheld RFID Reader Type designation: MC 9090 RFID LF extern Order No.: --- Test standards: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205, 15.207 and 15.209 Industry Canada Radio Standards Specifications RSS-Gen Issue 2, Section 7.2.2 and RSS-210 Issue 7, Sections 2.2, 2.6 (Category I Equipment) 13 January 2010 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 3) Page 2 of 55 Pages Table of Contents 1 Description of the Equipment Under Test (EUT)............................................................ 3 2 Administrative Data ........................................................................................................ 4 3 Identification of the Test Laboratory............................................................................... 5 4 Summary........................................................................................................................6 5 Operation Mode and Configuration of EUT .................................................................... 7 6 Measurement Procedures .............................................................................................. 8 6.1 Bandwidth Measurements ....................................................................................... 8 6.2 Radiated Emission Measurement 9 kHz to 30 MHz................................................. 9 6.3 Radiated Emission in Fully or Semi Anechoic Room ............................................. 11 6.4 Radiated Emission at Open Field Test Site ........................................................... 13 7 Photographs Taken During Testing.............................................................................. 15 8 Test Results ................................................................................................................. 22 8.1 Occupied Bandwidth .............................................................................................. 24 8.2 Bandwidth of the Emission..................................................................................... 30 8.3 Designation of Emissions....................................................................................... 33 8.4 Restricted Bands of Operation............................................................................... 34 8.5 Radiated Emission Measurement 9 kHz to 30 MHz.............................................. 37 8.6 Radiated Emission Measurement 30 MHz to 1 GHz............................................. 40 8.7 Exposure of Humans to RF Fields ......................................................................... 41 9 Referenced Regulations............................................................................................... 43 10 Revision History ........................................................................................................... 45 11 Charts taken during testing .......................................................................................... 46 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 3) Page 3 of 55 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : MC 9090 RFID LF extern Parts 2 : Serial number(s): 0001 Manufacturer: TECTUS Transponder Technology GmbH Type of equipment: Handheld RFID Reader Version: As received FCC ID: --- Additional parts/accessories: Technical data of EUT Application frequency range: 125 - 134.2 kHz Frequency range: 125 kHz, 134.2 kHz Operating frequency: 125 kHz 134.2 kHz Type of modulation: ASK Pulse train: --- Pulse width: --- Number of RF-channels: 2 Channel spacing: --- Designation of emissions 3 : 10K0A1D Type of antenna: Integrated loop Size/length of antenna: 3.5 x 1.5 cm Connection of antenna: detachable not detachable Type of power supply: Battery supply Specifications for power supply: nominal voltage: 5 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 3) Page 4 of 55 Pages 2 Administrative Data Application details Applicant (full address): TECTUS Transponder Technology GmbH Eurotecring 39 47445 Moers Deutschland Contact person: Herr Frank Scheuermann Order number: --- Receipt of EUT: June 17, 2009 Date(s) of test: June 2009 Note(s): Mr. Volker Söhlke representing TECTUS Transponder Technology GmbH and Mr. Sebastian Kuhn representing Bartec GmbH attended all testings. Report details Report number: 70751-00483-1 Edition: 3 Issue date: November 6, 2009 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 3) Page 5 of 55 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: TÜV SÜD SENTON GmbH Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory accreditation: DAR-Registration No. DAT-P-171/94-02 FCC test site registration number 90926 Industry Canada test site registration: 3050A-1 Contact person: Mr. Johann Roidt Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 TÜV SÜD SENTON Gm…
Text truncated - open the document above for the full version.
Test Equipment List with Calibration Data Page 1 of 2 Test report number(s): Date of test: 70751-00483-1/-2 06/2009 Date of Calibration Type Inv.-No. Type Designation Serial Number Manufacturer Calibration Organization Last Next Test receiver 1025 ESVP 881120/024 Rohde & Schwarz Rohde & Schwarz 03/2008 09/2009 Test receiver 1028 ESHS10 860043/016 Rohde & Schwarz Rohde & Schwarz 10/2008 04/2010 EMI Test receiver 1569 ESMI 839379/013 Rohde & Schwarz Rohde & Schwarz 04/2007 10/2009 EMI test receiver 1711 ESPI7 836914/0002 Rohde & Schwarz Rohde & Schwarz 10/2008 04/2010 EMI test receiver 1863 ESCI 1166.5950K03 100008 Rohde & Schwarz Rohde & Schwarz 06/2008 12/2009 Test receiver 2031 ESVP 891846/003 Rohde & Schwarz Rohde & Schwarz 10/2007 10/2009 Spectrum analyser 1666 FSP30 100063 Rohde & Schwarz Rohde & Schwarz 10/2007 10/2009 Preamplifier 1142 R14601 13120026 Advantest Senton 04/2008 04/2010 Preamplifier 1484 ACO/180-3530 32641 CTT Senton 05/2008 11/2009 Preamplifier 1651 CPA9231A 3393 Schaffner Electrotest Senton 05/2008 11/2009 Preamplifier 1684 AFS3-00100800-32-LN 847743 MITEQ Senton 05/2008 11/2009 V-network 1059 ESH3-Z5 894785/005 Rohde & Schwarz Rohde & Schwarz 05/2009 05/2012 V-network 1060 ESH3-Z5 862770/021 Rohde & Schwarz Rohde & Schwarz 01/2007 01/2010 V-network 1218 ESH3-Z5 830952/025 Rohde & Schwarz Rohde & Schwarz 07/2008 07/2011 Loop antenna 1016 HFH2-Z2 882964/0001 Rohde & Schwarz Rohde & Schwarz 12/2007 06/2009 Double ridged waveguide horn antenna 1516 3115 9508-4553 EMCO Elektronik ARC 05/2008 05/2011 Biconical Antenna 1518 HK116 842204/01 Rohde & Schwarz Rohde & Schwarz 06/2008 12/2009 Logarithmic-periodic antenna 1519 HL223 841516/23 Rohde & Schwarz Rohde & Schwarz 06/2008 12/2009 TRILOG broadband antenna 1722 VULB 9163 9163-188 Schwarzbeck Schwarzbeck 04/2008 10/2009 TRILOG Broadband Antenna 1802 VULB 9163 9163-214 Schwarzbeck Schwarzbeck 03/2008 09/2009 Multimeter 1653 21 III 76530546 Fluke ZMK 05/2008 02/2011 Note: Date of next calibration contains maximum tolerance if applicable. Test Equipment List with Calibration Data Page 2 of 2 Test report number(s): Date of test: 70751-00483-1/-2 06/2009 Date of Calibration Type Inv.-No. Type Designation Serial Number Manufacturer Calibration Organization Last Next Multimeter 1654 21 III 76381229 Fluke ZMK 03/2008 12/2010 Multimeter 1975 Fluke 77 III 92370108 Fluke ZMK 09/2008 06/2011 Multimeter 1976 Fluke 77 IV 93090238 Fluke ZMK 09/2008 06/2011 Digital multimeter 2025 Fluke 177 96720024 Fluke ZMK 09/2008 06/2011 Digital multimeter 2026 Fluke 177 96720025 Fluke ZMK 09/2008 06/2011 Note: Date of next calibration contains maximum tolerance if applicable.
TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 2) Page 16 of 55 Pages Test setup for radiated emission measurement 9 kHz – 30 MHz TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 2) Page 17 of 55 Pages Test setup for radiated emission measurement 9 kHz – 30 MHz - continued - TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 2) Page 18 of 55 Pages Test setup for radiated emission measurement (fully anechoic room) TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 2) Page 19 of 55 Pages Test setup for radiated emission measurement (fully anechoic room) - continued - TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 2) Page 20 of 55 Pages Test setup for radiated emission measurement (open field test site) TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 70751-00483-1 (Edition 2) Page 21 of 55 Pages Test setup for radiated emission measurement (open field test site) - continued -
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 0.1342 MHz - 0.1342 MHz | - |

RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
LF-Reader Module
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
RFID Reader
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
RFID Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
RFID Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter