TEB-HUNTSS762Transmitter for Watt-Hour Meter

Landis+Gyr Technologies, LLC
Transmitter for Watt-Hour Meter - FCC ID TEB-HUNTSS762 - Landis+Gyr Technologies, LLC
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jul 10, 2008
Application Purpose
Original Equipment
Date of Application
May 14, 2008
Equipment Note
Transmitter for Watt-Hour Meter
Frequency Range
904.00000000 - 927.50000000
Company
Landis+Gyr Technologies, LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Block Diagram

↗

Cover Letter(s)

External Photos

↗

ID Label/Location Info

Operational Description

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

6436 County Rd. 11 Pequot Lakes, MN 56472 218.562.4877 800.828.4055 Fax 218.562.4878 www.hunttechnologies.com May-14-08 Federal Communications Commission 445 12th Street, SW Washington, DC 20554 Re: Meter Manufacturer Manual, TEB-HUNTSS762 The STATSignal Focus Module (FASY-0762-XXXX) is installed in Landis + Gyr’s electric meters as original equipment. It is a single PCB that contains both the Focus metrology PCB as well as the Hunt Technologies’ STATSignal PCB. We do not supply a manual with the unit but we do notify the meter manufacturer of the required statements that must be placed in the meter manual, meeting the requirements of the Federal Communications Commission CFR 47, Part 15, Paragraph 15.19(a)(3) and Industry Canada RSS-210, Paragraph 5.11. A ‘Ship-Sheet’ is sent along with the final product to the end user; in this the 15.19 requirements are also stated. See Exhibit D Ship Sheet. Sincerely, Hunt Technologies, LLC 6436 County Road 11 Pequot Lakes, MN 56472 www.hunttechnologies.com

Users Manual

Data SheetPUBS-0762-0001 Rev A1 FOCUS Universal RF Endpoint Data Sheet General The Cellnet+Hunt FOCUS Universal RF endpoint is designed to accommodate Landis+Gyr FOCUS meters for use in residential and light industrial services. The FOCUS Universal RF module directly reads kWh usage data from the meter register and sends this information to a data collection device utilizing RF transmission. The collector forwards this information to Cellnet+Hunts’ Command Center software. Figure 1. The Cellnet+Hunt FOCUS Universal RF Endpoint Module and Landis+Gyr FOCUS Meter FCC Compliance Information Model: FASY-0762 FCCID: TEB-HUNTSS762 IC: 5931A-HUNTSS762 FOCUS Universal RF Endpoint Data SheetCellnet+Hunt 2PUBS-0762-0001 Rev AData Sheet Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1.This device may not cause harmful interference, and 2.This device must accept any interference received, including interference that may cause undesired operation. Endpoint Location To comply with FCC’s RF exposure limits for general population/uncontrolled exposure, the antenna(e) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Endpoint Usage The FOCUS Universal RF endpoint will be used: •for residential and commercial metering applications. •at homes and businesses. The FOCUS Universal RF endpoint requires professional installation by qualified personnel. RF Interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the meter off, the user is encouraged to try to correct the interference by one or more of the following measures: •Re-orient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Consult Cellnet+Hunt or an experienced radio/TC technician for help. Changes or modifications not expressly approved by Cellnet+Hunt for compliance could void the user’s authority to operate the equipment. Cellnet+HuntFOCUS Universal RF Endpoint Data Sheet Data SheetPUBS-0762-0001 Rev A3 Specifications Table 1. FOCUS Universal RF Endpoint Specifications CategorySpecificationValue or Range Compatible Meters Meter TypeLandis+Gyr FOCUS AL Supported Meter Forms 120V FASY-0762-0001240V FASY-0762-0002 For m Clas s L+G Part NumberFor m Clas s L+G Part Number 1S100EA0000T0- QQQQ* 2S200EA1100T0- QQQQ* 3S20EA0G00T0- QQQQ* 2SE320EA1400T0- QQQQ* 12S200EA01C0T0- QQQQ* 2K480EA1600T0- QQQQ* 25S200 EA0A00T0- QQQQ* 3S20EA0H00T0- QQQQ* 4S20EA0J00T0-QQQQ* NOTE:The last four digits of the Landis+Gyr part number identify a specific customer feature set including custom name plate, programming and RKAs. Electrical Voltage120/240V (depending on meter form) Power Max: 2.2W (1.2W meter, 1W transceiver) Typical: 1.2W (.7W meter, .5W transceiver) RF Output Power+26 dBm +/-2 dBm Adjacent Channel Power+50 dBc Nominal Transmit Frequency902 to 928 MHz ISM unlicensed (FCC Part 15) Communication ProtocolStat RF MESH Protocol Receive Sensitivity -108 dBm minimum Standards Compliance FCC Title 47 CFR Part 15Radiated and Conducted Emissions (incl. intentional radiators) IEC 61000 4-2,3,4,5,11,12Electromagnetic Compatibility ANSI C12.19Compatible with Utility Industry End Device Tables ANSI C12.20National Standard for Electricity Meters - 0.2 and 0.5 Accuracy Classes ANSI C12.21Code for Electricity Metering ANSI C37.90.1 (1989)Standard Surge Withstand Capability (SWC) Tests FOCUS Universal RF Endpoint Data SheetCellnet+Hunt 4PUBS-0762-0001 Rev AData Sheet Environmental General EnvironmentalOutdoor, rain-protected, sunlight-exposed Operating Temperature Range -40 to +70 C (under meter glass) Humidity0 to 95% relative humidity, non-condensing Mechanical Size4 H x 4.8125 W x 1.25 D inches, typical Weight5 ounces (142 g), typical Table 1. FOCUS Universal RF Endpoint Specifications CategorySpecificationValue or Range Contact Information: Technical Support: 1-888-390-5733 Internet: www.cellnethunt.com Fax 1-218-562-5530 E-mail: [email protected]

Block Diagram

TEB-HUNTSS762: BLOCK DIAGRAM 120/240 VAC 9VAC Transformer Fullbridge Unregulated 12VDC 3.3VDC Regulator AC LINE CURENT CT POWER FAIL (VSENSE) TERIDIAN 16K ROM 71M6521 LCD DISPLAY 3.3V Emulator Header AC LINE VOLTAGE SENSOR OPTICAL TRANSCEIVER SERIAL IIC 32Kb E 2 PSEM INTERFACE (UART) 32K OSC Tubular RENESAS M30626FHPGP#U7 384K FLASH 31K RAM SERIAL IIC 512Kb E 2 (Load Profile) SERIAL IIC 4Mb FLASH (F/W Swap) Watchdog Supervisor (2.93V trip) 3.3 VDC Test Switch Diagnostic LEDs Test Interface (UART) CHIPCON RF ASIC TRANSCIEVER 915MHz CC 1020 14.7456 MHz TCXO RF Power Amplifier LNA SAW FILTER RF SWITCH LOW PASS FILTER ANTENNA (Etched in to PCB) LDO Regulator 3.3VDC Buck/Boost Regulator 3.6VDC SuperCap 3F (5VDC) SuperCap Charger 4.5VDC 3.3 VDC Programming Header Temperature Sensor

External Photos

Exhibit A: Exterior Photos FCC ID: TEB-HUNTSS762 Front of Meter The end use will not be able to see our module, the only visual clue that there is an Cellnet+Hunt product in the meter will be the label on the meter shell stating the unit’s serial number and FCC ID of the module located inside. (Exhibit C-Exterior Label) The other label on the meter shell is produced by Landis + Gyr, and is a standard Watt- Hour meter label stating such things as: Meter ID, Class, Voltage, etc. Location of External Label: Exhibit C

Operational Description

TEB-HUNTSS762 Operational Statement: This device is an integration of two existing products, 1) Landis + Gyr metrology circuit board and 2) Hunt Technologies Focus Module circuit board. The RF module will read the data from the metrology portion. The RF transmitter Gaussian Frequency Shift Keying (GFSK) signals to compatible receivers. It’s transmit frequency is based on a table of at least 50 preset pseudo-random frequencies, stored in EEPROM. This table ensures that each of the frequencies are used the same number of times. The frequency synthesizer uses a crystal oscillator circuit as its reference to produce a frequency between 904 and 927.9, which is turned on and off by the modulator to produce a GFSK signal.

Test Report

Exhibit O: Radiated Setup FCC ID: TEB-HUNTSS762 Hunt Technologies, LLC 5-14-08 6436 County Rd. 11 Pequot Lakes, MN 56472

Test Report

Test Report FCC ID: TEB-HUNTSS762 Page 1 of 19 Hunt Technologies, Inc. 5/16/2008 6436 County Rd. 11 Pequot Lakes, MN 56472 FCC Part 15.247 Transmitter Certification Frequency Hopping Spread Spectrum Transmitter Test Report FCC ID: TEB-HUNTSS762 FCC Rule Part: 15.247 Test Begin Date: 4/18/2008 Test End Date: 5/10/08 Report Issue Date: 5/14/08 Test Report FCC ID: TEB-HUNTSS762 Page 2 of 19 Hunt Technologies, Inc. 5/16/2008 6436 County Rd. 11 Pequot Lakes, MN 56472 Table of Contents 1.0 GENERAL .............................................................................................................................................. 3 1.1 PURPOSE ............................................................................................................................................ 3 1.2 PRODUCT DESCRIPTION ................................................................................................................... 3 1.2.1 General .................................................................................................................................... 3 1.2.2 Intended Use ........................................................................................................................ 3 2.0 STATEMENT OF COMPLIANCE ...................................................................................................... 3 3.0 APPLICABLE STANDARD REFERENCES ..................................................................................... 5 4.0 LIST OF TEST EQUIPMENT ............................................................................................................ 5 5.0 EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ............................................................ 6 6.0 SUMMARY OF TESTS........................................................................................................................ 6 6.1 FREQUENCIES TO BE EXAMINED [§15.31(M)] .............................................................................. 6 6.2 ANTENNA REQUIREMENT [§15.203] ............................................................................................. 6 6.3 ANTENNA CHARACTERISTICS [§15.204] ....................................................................................... 6 6.3.1 Antenna Type ........................................................................................................................ 6 6.3.2 Antenna Manufacturer ...................................................................................................... 6 6.3.3 Antenna Gain ........................................................................................................................ 6 6.4 POWER LINE CONDUCTED EMISSIONS [§15.207] ....................................................................... 7 6.4.1 Test Methodology................................................................................................................ 7 6.4.2 Test Results ........................................................................................................................... 7 6.5 RADIATED EMISSIONS [§15.109] AND RADIATED SPURIOUS EMISSIONS (RESTRICTED BANDS) [§15.205] ................................................................................................................................. 7 6.5.1 Test Methodology................................................................................................................ 7 6.5.2 Calculation of allowed limit for Radiated Spurious Emissions ........................... 7 6.5.3 Test Results ........................................................................................................................... 7 6.6 PEAK OUTPUT POWER – [§15.247(B)(2)] .................................................................................. 7 6.6.1 Test Methodology (Conducted Method) ..................................................................... 7 6.6.2 Test Results ........................................................................................................................... 7 6.6.3 De Facto EIRP Limit ........................................................................................................... 9 6.6.4 RF Exposure Compliance Requirements ..................................................................... 9 6.7 CHANNEL USAGE REQUIREMENTS [§15.247(A) (1)] .................................................................. 9 6.7.1 Carrier Frequency Separation ......................................................................................... 9 6.7.1.1 Test Methodology ........................................................................................................................ 9 6.7.1.2 Test Results ................................................................................................................................. 10 6.7.2 Number of Hopping Channels ........................................................................................10 6.7.3 Channel Dwell Time...........................................................................................................12 6.7.3.1 Test Methodology ...................................................................................................................... 12 6.7.3.2 Test Results ................................................................................................................................. 13 6.7.4 20dB Bandwidth .................................................................................................................13 6.7.4.1 Test Methodology ...................................................................................................................... 13 6.7.4.2 Test Results ................................................................................................................................. 13 6.8 BAND-EDGE COMPLIANCE AND SPURIOUS EMISSIONS [§15.247(C)] ......................................15 6.8.1 Band-Edge Compliance of RF Conducted…

Text truncated - open the document above for the full version.

Test Report

Test Report FCC ID: TEB-HUNTSS762 Page 1 of 20 Hunt Technologies, Inc. 5/16/2008 6436 County Rd. 11 Pequot Lakes, MN 56472 FCC Part 15.247 Transmitter Certification Frequency Hopping Spread Spectrum Transmitter Test Report FCC ID: TEB-HUNTSS762 FCC Rule Part: 15.247 Test Begin Date: 4/18/2008 Test End Date: 5/10/08 Report Issue Date: 5/14/08 Test Report FCC ID: TEB-HUNTSS762 Page 2 of 20 Hunt Technologies, Inc. 5/16/2008 6436 County Rd. 11 Pequot Lakes, MN 56472 Table of Contents 1.0 GENERAL .............................................................................................................................................. 3 1.1 PURPOSE ............................................................................................................................................ 3 1.2 PRODUCT DESCRIPTION ................................................................................................................... 3 1.2.1 General .................................................................................................................................... 3 1.2.2 Intended Use ........................................................................................................................ 3 2.0 STATEMENT OF COMPLIANCE ...................................................................................................... 3 3.0 APPLICABLE STANDARD REFERENCES ..................................................................................... 5 4.0 LIST OF TEST EQUIPMENT ............................................................................................................ 5 5.0 EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ............................................................ 6 6.0 SUMMARY OF TESTS........................................................................................................................ 6 6.1 FREQUENCIES TO BE EXAMINED [§15.31(M)] .............................................................................. 6 6.2 ANTENNA REQUIREMENT [§15.203] ............................................................................................. 6 6.3 ANTENNA CHARACTERISTICS [§15.204] ....................................................................................... 6 6.3.1 Antenna Type ........................................................................................................................ 6 6.3.2 Antenna Manufacturer ...................................................................................................... 6 6.3.3 Antenna Gain ........................................................................................................................ 6 6.4 POWER LINE CONDUCTED EMISSIONS [§15.207] ....................................................................... 7 6.4.1 Test Methodology................................................................................................................ 7 6.4.2 Test Results ........................................................................................................................... 7 6.5 RADIATED EMISSIONS [§15.109] AND RADIATED SPURIOUS EMISSIONS (RESTRICTED BANDS) [§15.205] ................................................................................................................................. 7 6.5.1 Test Methodology................................................................................................................ 7 6.5.2 Calculation of allowed limit for Radiated Spurious Emissions ........................... 7 6.5.3 Test Results ........................................................................................................................... 7 6.6 PEAK OUTPUT POWER – [§15.247(B)(2)] .................................................................................. 7 6.6.1 Test Methodology (Conducted Method) ..................................................................... 7 6.6.2 Test Results ........................................................................................................................... 7 6.6.3 De Facto EIRP Limit ........................................................................................................... 9 6.6.4 RF Exposure Compliance Requirements ..................................................................... 9 6.7 CHANNEL USAGE REQUIREMENTS [§15.247(A) (1)] .................................................................. 9 6.7.1 Carrier Frequency Separation ......................................................................................... 9 6.7.1.1 Test Methodology ........................................................................................................................ 9 6.7.1.2 Test Results ................................................................................................................................. 10 6.7.2 Number of Hopping Channels ........................................................................................10 6.7.3 Channel Dwell Time...........................................................................................................12 6.7.3.1 Test Methodology ...................................................................................................................... 13 6.7.3.2 Test Results ................................................................................................................................. 13 6.7.4 20dB Bandwidth .................................................................................................................13 6.7.4.1 Test Methodology ...................................................................................................................... 13 6.7.4.2 Test Results ................................................................................................................................. 13 6.8 BAND-EDGE COMPLIANCE AND SPURIOUS EMISSIONS [§15.247(C)] ......................................16 6.8.1 Band-Edge Compliance of RF Conducted…

Text truncated - open the document above for the full version.

Test Setup Photos

Internal Photos Front: Back:

Contact Information

Applicant

Carl W Jacobi(Hardware Test Engineer)
[email protected]218-562-5125Fax: 218-562-4878

Test Firm

TUV SUD America - Product ServiceJoel Schneider
[email protected]651-604-4582Fax: 651-638-0298

Technical Specifications

#Rule PartsFrequency RangePower Output
115C904 MHz - 927.5 MHz631.00 mW
Confidentiality
Long Term

Other Applications from Landis+Gyr Technologies, LLC

Utility Meter Transceiver Module - FCC ID TEB-HUNTGS10122 - Landis+Gyr Technologies, LLC
TEB-HUNTGS10122

Utility Meter Transceiver Module

Dec 06, 2011

Equipment Class

DTS - Digital Transmission System
FOCUS AX Modular Gridstream - FCC ID TEB-HUNTSU864 - Landis+Gyr Technologies, LLC
TEB-HUNTSU864

FOCUS AX Modular Gridstream

May 12, 2010

Equipment Class

DTS - Digital Transmission System
3G S4e Gridstream - FCC ID TEB-HUNTSU825 - Landis+Gyr Technologies, LLC
TEB-HUNTSU825

3G S4e Gridstream

Mar 07, 2010

Equipment Class

DTS - Digital Transmission System
TEB-HUNTTS764

TS2 Focus AX

Sep 15, 2009

Equipment Class

DTS - Digital Transmission System
TEB-HUNTSS710

Multi-Utility Residential Endpoint

May 01, 2008

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter