Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Landis+Gyr Confidential Information98-9103 Rev AA1 3G S4e Gridstream Endpoint with ZigBee Data Sheet General The 3G S4e Gridstream endpoint is designed to accommodate Landis+Gyr S4e poly-phase meters for use in commercial and light industrial services. The S4e Advanced Function meter is an Active Energy kWh/kW/TOU Meter. The meter features Digital Multiplication Measurement Technique, meets ANSI standards for performance and utilizes ANSI C12.19 protocol (between meter and AMR device). Can be deployed with or without ZigBee. Display Options •Energy Metrics: +kWh, -kWh, Net kWh, and added kWh (Security). Figure 1. The 3G S4e Gridstream Endpoint Module and the Landis+Gyr S4e Meter FCC Compliance Information Model: FASY-0825 FCCID: TEB-HUNTSU825 IC: 5931A-HUNTSU825 3G S4e Gridstream Endpoint with ZigBee Data SheetLandis+Gyr 298-9103 Rev AALandis+Gyr Confidential Information Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1.This device may not cause harmful interference, and 2.This device must accept any interference received, including interference that may cause undesired operation. Endpoint Location To comply with FCC’s RF exposure limits for general population/uncontrolled exposure, the antenna(e) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Endpoint Usage The 3G S4e Gridstream endpoint will be used: •for commercial and light industrial metering applications. •at homes and businesses. The 3G S4e Gridstream endpoint requires professional installation by qualified personnel. RF Interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the meter off, the user is encouraged to try to correct the interference by one or more of the following measures: •Re-orient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Consult Landis+Gyr or an experienced radio/TC technician for help. Changes or modifications not expressly approved by Landis+Gyr could void the user’s authority to operate the equipment. Landis+Gyr3G S4e Gridstream Endpoint with ZigBee Data Sheet Landis+Gyr Confidential Information98-9103 Rev AA3 Required Software To work with the endpoint, you need one of the following software tools: •Command Center ver. 4.1 or greater •RadioShop. •Network Configuration Manager. •Landis+Gyr 1132Prog application. •Endpoint Testing Manager. •Endpoint Implementation Manager. Specifications Table 1. 3G S4e Gridstream Endpoint Specifications CategorySpecificationValue or Range Compatible Meters Landis+Gyr S4e Supported Meter Forms FormClassFormClass 3S2016SE320 5S/45S2016/15K480 6S/36S20 9S/8S20 2S200 12S200 16S/15S200 25S200 12SE320 Electrical Voltage10.5-13.5V (from the meter’s power supply) Power Max: 2.5W Typical: 0.5W RF 900 MHz Output Power+26 dBm +/-1 dBm Adjacent Channel Power39 dBc Nominal Transmit Frequency902 to 928 MHz ISM unlicensed (FCC Part 15) Communication ProtocolGridstream Protocol for Command Center Receive Sensitivity -108 dBm minimum RF ZigBee Output Power+20 dBm +/-1 Adjacent Channel Power40 dBc Minimum Transmit Frequency2405-2480 MHz Communication ProtocolZigBee Protocol Receive Sensitivity-104 dBm minimum 3G S4e Gridstream Endpoint with ZigBee Data SheetLandis+Gyr 498-9103 Rev AALandis+Gyr Confidential Information Standards Compliance FCC Title 47 CFR Part 15Radiated and Conducted Emissions (incl. intentional radiators) IEC 61000 4-2,3,4,5,11,12Electromagnetic Compatibility ANSI C12.19Compatible with Utility Industry End Device Ta b l e s ANSI C12.20National Standard for Electricity Meters - 0.2 and 0.5 Accuracy Classes ANSI C12.21Code for Electricity Metering ANSI C37.90.1 (1989)Standard Surge Withstand Capability (SWC) Te s t s ANSI C12.22Transport of ANSI C12.19 Over Network Transmissions Environmental General EnvironmentalOutdoor, rain-protected, sunlight-exposed Operating Temperature Range-40 to +70 C (under meter glass) Humidity0 to 95% relative humidity, non-condensing Mechanical Size Weight Contact Information Technical Support: 1-888-390-5733 Internet: www.landisgyr.com Fax 1-218-562-5530 E-mail: [email protected] Table 1. 3G S4e Gridstream Endpoint Specifications CategorySpecificationValue or Range
Exhibit A: External Photo TEB-HUNTSU825 FCC/IC Label Location
2.8 .75 LAYOUT PROVIDED BY HUNT. R .05 (OPTIONAL). DO NOT PRINT BORDER. 6 78 4 A B 321 A B C D 4 C 32 D 1 ANGLE TOLERENCE DOES NOT APPLY TO IMPLIED 90 ANGLES TOLERENCES ON: DIMENSIONS ARE AFTER FINISH IS APPLIED 2 PL ± .02 AC REVISION: THIRD ANGLE PROJECTION LANDIS+GYR CONFIDENTIAL INFORMATION: THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO LANDIS + GYR FAMILY OF COMPANIES.(WHICH INCLUDES THE COMPANIES FORMERLY KNOWN AS HUNT AND CELLNET) ANY USE OR DISCLOSURE WITHOUT WRITTEN PERMISSION IS PROHIBITED. SHEET: 1 OF 1 23-0044 3 PL ± .005 SIZE: DATED: DATED: TITLE: DIMENSIONS ARE IN INCHES [MM] BREAK ALL SHARP EDGES. DRAWN BY: APPROVED BY: 1 PL ± .1 ± 1/64 ±1 DECIMAL FRACTION ANGLE UNLESS OTHERWISE SPECIFIED: MUST BE FREE FROM FLASH AND BURRS. ( ) DENOTES REFERENCE ONLY. DO NOT SCALE DRAWING DRAWING NO. T. HANNAH 01/06/10 01/06/10 S. O'BRYAN C LABEL, EXT BARCODE FCC IC RFID STAT + UTILINET NOTES: 1. MATERIAL: 2 MIL POLYMIDE, TYPE TS866. 2. THIS ASSEMBLY SHALL BE IN ACCORDANCE WITH DOCUMENT NUMBER 95-1062.SURFACES SHALL BE CONSIDERED "CLASS E" SURFACES, UNLESS OTHERWISE SPECIFIED. 3. THIS LABEL SHALL BE IN ACCORDANCE WITH DOUCMENT NUMBER 95-1067 (LABEL SPECIFICATION). 4. ARTWORK LAYOUT TO BE LOCATED AS SHOWN, AND TO BE APPROVED BY LANDIS + GYR ENGINEERING. 5. DIGITAL INKING SYSTEM FOR TEXT & BAR CODE TO BE PERMANENT BLACK, U.V. RESISTANT. 6. 8 DIGIT HEXIDECIMAL SERIAL NO. TO BE IMPRINTED IN HUMAN READABLE FORM BELOW THE 8 DIGIT SERIAL NUMBER. INFORMATION IN CODE 128C WITH NO SPACES. (BARCODE HEIGHT TO BE .150 MIN). THE BAR CODE CAN RUN OFF THE BOTTOM OF THE LABEL. 7. FCC I.D. NUMBER TO BE LISTED ACROSS THE TOP OF THE LABEL. 8. HUNT PRODUCT NAME LISTED AS SHOWN. 9. LABEL MANUFACTURER: WHEN EACH PURCHASE ORDER IS COMPLETED, PROVIDE THE VERIFIED RANGE & DATE COMPLETED TO HUNT TECHNOLOGIES MANUFACTURING ENGINEER OR PURCHASING. 10. NARROW BAR IS 10 MIL. 11. THIS LABEL SHALL BE PRINTED BY THE CONTRACT MANUFACTURER AS PART OF THE MODULE MANUFACTURING PROCESS. IT WILL BE INCLUDED WITH EACH MODULE WHEN SHIPPED TO THE METER MANUFACTURER FOR METER INTEGRATION. THIS LABEL WILL BE PLACED ON THE OUTSIDE OF THE METER HOUSING DURING METER ASSEMBLY. THE SERIAL NUMBER ON THIS LABEL MUST MATCH THAT OF THE LABEL OF THE MODULE INSTALLED IN THE METER.
Exhibit B: Internal Photos TEB-HUNTSU825 Front Back FCC/IC Compliance Information
Exhibit F: Operational Statement TEB-HUNTSU825 This device is a daughter board module, manufactured by Hunt Technologies, LLC, that plugs into a Landis+Gyr S4e metrology circuit board. The daughter board contains two separate radios: a 900 MHz ISM band frequency-hopping spread spectrum (FHSS) transceiver and a 2.4 GHz ISM band transceiver employing 802.15.4/ZigBee. The 900 MHz radio circuit reads data from the metrology circuit board and transmits Gaussian Frequency Shift Keying (GFSK) signals to compatible receivers. It’s transmit frequency is based on a table of fifty preset pseudo-random frequencies stored in EEPROM. This table ensures that each of the frequencies are used the same number of times. The frequency synthesizer uses a crystal oscillator circuit as its reference to produce a frequency between 902.1 and 927.9 MHz, which is turned on and off by the modulator to produce a GFSK signal. The 2.4 GHz radio circuit reads data from the metrology and 900 MHz radio circuits and transmits Offset Quadrature Phase Shift Keying (O-QPSK) signals, based on the 802.15.4/ZigBee standards, to various in- home ZigBee-enabled devices. The radio will also receive data from these devices. The radio employs sixteen channels between 2.405 and 2.480 GHz and utilizes Direct Sequence Spread Spectrum (DSSS) coding with a 2 Mchip/s rate in accordance with the 802.15.4/ZigBee standards. The 2.4 GHz radio also utilizes antenna diversity to increase the effective range of the device. Antenna diversity is achieved in this circuit via two identical etched PCB inverted-F antennas placed on opposite ends of the PCB, about five inches apart. One antenna is selected at any given time to transmit or receive from based on an algorithm designed to choose the best-performing antenna at that moment.
Exhibit P: RF Exposure TEB-HUNTSU825 General Information Applicant: Hunt Technologies, LLC FCC ID: TEB-HUNTSU825 Device Category: Mobile Environment: General Population/Uncontrolled Exposure Technical Information 900 MHz Antenna Type: ½ Wave Dipole at 915 MHz Antenna Gain: 2.15 dBi (Theoretical maximum) Transmitter Conducted Power: 25.99 dBm Maximum System EIRP: 28.14 dBm Operating Configuration: Fixed mounted Exposure Conditions: Greater than 20 centimeters Technical Information 2400 MHz ZigBee Antenna Type: PCB Inverted F ¼-Wave Monopole Antenna Gain: 5.15 dBi (Theoretical maximum) Transmitter Conducted Power: 20.03 dBm Maximum System EIRP: 25.18 dBm Operating Configuration: Fixed mounted Exposure Conditions: Greater than 20 centimeters MPE Calculation The Power Density (mW/cm 2 ) is calculated as follows: Where: S = power density (in appropriate units, e.g. mW/cm 2 ) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) MPE CALCULATIONS FOR MOBILE EQUIPMENT Transmit Frequency (MHz) Conducted Power (dBm) Conducted Power (mW) Antenna Gain (dBi) Antenna Gain (Linear) Distance (cm) Power Density (mW/cm 2 ) Power Density Limit (mW/cm 2 ) 915 25.99 397.19 2.15 1.641 20 0.130 0.60 2405 20.03 100.69 5.15 3.273 20 0.0656 1.00 Installation Guidelines Exhibit D - Product Ship Sheet contains the following text advising how to install the equipment to maintain compliance with the FCC RF exposure requirements: Endpoint Location To comply with FCC’s RF exposure limits for general population/uncontrolled exposure, the antenna(e) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Conclusion This device complies with the MPE requirements by providing adequate separation between the device, any radiating structure, and the general population.
Test Report FCC ID: TEB-HUNTSU825 Page 1 of 18 Hunt Technologies, LLC 1/6/2010 6436 County Rd. 11 Pequot Lakes, MN 56472 FCC Part 15.247 Transmitter Certification 2.4 GHz ISM Band Direct Sequence Spread Spectrum Transmitter Test Report FCC ID: HUNTSU825 FCC Rule Part: 15.247 Test Begin Date: 11/04/2009 Test End Date: 11/18/2009 Report Issue Date: 1/6/2010 Test Report FCC ID: TEB-HUNTSU825 Page 2 of 18 Hunt Technologies, LLC 1/6/2010 6436 County Rd. 11 Pequot Lakes, MN 56472 Table of Contents 1.0 GENERAL .............................................................................................................................................. 3 1.1 PURPOSE ............................................................................................................................................ 3 1.2 PRODUCT DESCRIPTION ................................................................................................................... 3 1.2.1 General .................................................................................................................................... 3 1.2.2 Intended Use ........................................................................................................................ 3 2.0 STATEMENT OF COMPLIANCE ...................................................................................................... 3 3.0 APPLICABLE STANDARD REFERENCES ..................................................................................... 5 4.0 LIST OF TEST EQUIPMENT ............................................................................................................ 5 5.0 EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ............................................................ 6 6.0 SUMMARY OF TESTS........................................................................................................................ 6 6.1 FREQUENCIES TO BE EXAMINED [§15.31(M)] .............................................................................. 6 6.2 ANTENNA REQUIREMENT [§15.203] ............................................................................................. 6 6.3 ANTENNA CHARACTERISTICS [§15.204] ....................................................................................... 6 6.3.1 Antenna Type ........................................................................................................................ 7 6.3.2 Antenna Manufacturer ...................................................................................................... 7 6.3.3 Antenna Gain ........................................................................................................................ 7 6.4 POWER LINE CONDUCTED EMISSIONS [§15.207] ....................................................................... 7 6.4.1 Test Methodology................................................................................................................ 7 6.4.2 Test Results ........................................................................................................................... 7 6.5 RADIATED EMISSIONS [§15.109] AND RADIATED SPURIOUS EMISSIONS (RESTRICTED BANDS) [§15.205] ................................................................................................................................. 7 6.5.1 Test Methodology................................................................................................................ 7 6.5.2 Calculation of allowed limit for Radiated Spurious Emissions ........................... 8 6.5.3 Test Results ........................................................................................................................... 8 6.6 PEAK OUTPUT POWER – [§15.247(B)(3)] .................................................................................. 9 6.6.1 Test Methodology (Conducted Method) ..................................................................... 9 6.6.2 Test Results ..........................................................................................................................10 6.6.3 De Facto EIRP Limit ..........................................................................................................11 6.6.4 RF Exposure Compliance Requirements ....................................................................11 6.7 6-DB BANDWIDTH [§15.247(A)(2)] ..........................................................................................11 6.7.1 Test Methodology ........................................................................................................ 11 6.7.2 Test Results ................................................................................................................. 11 6.8 PEAK POWER SPECTRAL DENSITY [§15.247(E)] ........................................................................13 6.8.1 Test Methodology ........................................................................................................ 13 6.8.2 Test Results ................................................................................................................. 13 6.9 BAND-EDGE COMPLIANCE AND SPURIOUS EMISSIONS [§15.247(D)] ......................................14 6.9.1 Band-Edge Compliance of RF Emissions ....................................................................14 6.9.1.1 Test Methodology ................................................................................................................. 14 6.9.1.2 Test Results ............................................................................................................................ 14 6.9.2 RF Conducted Spurious Emissions ...............................................................................15 6.9.2.1 Test Methodology ................................................................................................................. 15 6.9.2.2 Test Results ..........................................................................................................…
Text truncated - open the document above for the full version.
CONDUCTED EMISSIONS Test Report #: WC905024 Run 1 Test Area: STS EUT Model #: S4E Date: 6/23/2009 EUT Serial #: N/A EUT Power: 240V/60Hz Temperature: 36.0 °C Test Method: FCC Part 15 Air Pressure: 98.0 kPa Customer: Landis & GYR Rel. Humidity: 40.0 % EUT Description: Electric Meter Notes: Data File Name: 5024.dat Page: 1 of 5 Tested by: Robert J Behringer Printed Signature Reviewed by: Printed Signature List of measurements for run #: 1 FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV) EUT Lead DELTA1 FCC 15.207 CE QP DELTA2 FCC 15.207 CE Avg Start of Conducted Scan 150.0 kHz 52.94 Qp 0.23 / 0.2 / 0.0 / 0.0 53.37 N -12.63 n/a 210.0 kHz 45.18 Qp 0.26 / 0.12 / 0.0 / 0.0 45.56 N -17.64 n/a 350.0 kHz 39.78 Qp 0.32 / 0.1 / 0.0 / 0.0 40.2 N -18.76 n/a 450.0 kHz 38.5 Qp 0.35 / 0.1 / 0.0 / 0.0 38.95 N -17.92 n/a 625.0 kHz 40.2 Qp 0.41 / 0.16 / 0.0 / 0.0 40.77 N -15.23 n/a 875.0 kHz 31.24 Qp 0.47 / 0.2 / 0.0 / 0.0 31.91 N -24.09 n/a 1.54 MHz 23.6 Qp 0.65 / 0.1 / 0.0 / 0.0 24.35 N -31.65 n/a 2.75 MHz 26.36 Qp 0.9 / 0.1 / 0.0 / 0.0 27.36 N -28.64 n/a 4.0 MHz 27.86 Qp 1.12 / 0.1 / 0.0 / 0.0 29.08 N -26.92 n/a 6.825 MHz 26.62 Qp 1.51 / 0.14 / 0.0 / 0.0 28.27 N -31.73 n/a 13.615 MHz 22.44 Qp 2.11 / 0.48 / 0.0 / 0.0 25.03 N -34.97 n/a 17.515 MHz 29.2 Qp 2.44 / 0.68 / 0.0 / 0.0 32.31 N -27.69 n/a 24.165 MHz 15.74 Qp 2.84 / 1.0 / 0.0 / 0.0 19.57 N -40.43 n/a 150.0 kHz 41.21 Av 0.23 / 0.2 / 0.0 / 0.0 41.64 N n/a -14.36 210.0 kHz 36.82 Av 0.26 / 0.12 / 0.0 / 0.0 37.2 N n/a -16.0 350.0 kHz 31.72 Av 0.32 / 0.1 / 0.0 / 0.0 32.14 N n/a -16.82 450.0 kHz 29.01 Av 0.35 / 0.1 / 0.0 / 0.0 29.46 N n/a -17.41 625.0 kHz 34.45 Av 0.41 / 0.16 / 0.0 / 0.0 35.02 N n/a -10.98 875.0 kHz 25.41 Av 0.47 / 0.2 / 0.0 / 0.0 26.08 N n/a -19.92 1.54 MHz 20.13 Av 0.65 / 0.1 / 0.0 / 0.0 20.88 N n/a -25.12 2.75 MHz 19.24 Av 0.9 / 0.1 / 0.0 / 0.0 20.24 N n/a -25.76 4.0 MHz 14.32 Av 1.12 / 0.1 / 0.0 / 0.0 15.54 N n/a -30.46 6.825 MHz 21.43 Av 1.51 / 0.14 / 0.0 / 0.0 23.08 N n/a -26.92 13.615 MHz 21.31 Av 2.11 / 0.48 / 0.0 / 0.0 23.9 N n/a -26.1 17.515 MHz 24.87 Av 2.44 / 0.68 / 0.0 / 0.0 27.98 N n/a -22.02 24.165 MHz 6.13 Av 2.84 / 1.0 / 0.0 / 0.0 9.96 N n/a -40.04 150.0 kHz 52.74 Qp 0.23 / 0.2 / 0.0 / 0.0 53.17 L1 -12.83 n/a CONDUCTED EMISSIONS Test Report #: WC905024 Run 1 Test Area: STS EUT Model #: S4E Date: 6/23/2009 EUT Serial #: N/A EUT Power: 240V/60Hz Temperature: 36.0 °C Test Method: FCC Part 15 Air Pressure: 98.0 kPa Customer: Landis & GYR Rel. Humidity: 40.0 % EUT Description: Electric Meter Notes: Data File Name: 5024.dat Page: 2 of 5 Tested by: Robert J Behringer Printed Signature Reviewed by: Printed Signature List of measurements for run #: 1 FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV) EUT Lead DELTA1 FCC 15.207 CE QP DELTA2 FCC 15.207 CE Avg 210.0 kHz 45.54 Qp 0.26 / 0.12 / 0.0 / 0.0 45.92 L1 -17.28 n/a 350.0 kHz 35.38 Qp 0.32 / 0.1 / 0.0 / 0.0 35.8 L1 -23.16 n/a 450.0 kHz 37.96 Qp 0.35 / 0.1 / 0.0 / 0.0 38.41 L1 -18.46 n/a 625.0 kHz 35.24 Qp 0.41 / 0.16 / 0.0 / 0.0 35.81 L1 -20.19 n/a 875.0 kHz 24.46 Qp 0.47 / 0.2 / 0.0 / 0.0 25.13 L1 -30.87 n/a 1.54 MHz 18.9 Qp 0.65 / 0.1 / 0.0 / 0.0 19.65 L1 -36.35 n/a 2.75 MHz 18.34 Qp 0.9 / 0.1 / 0.0 / 0.0 19.34 L1 -36.66 n/a 4.0 MHz 22.02 Qp 1.12 / 0.1 / 0.0 / 0.0 23.24 L1 -32.76 n/a 6.825 MHz 26.94 Qp 1.51 / 0.14 / 0.0 / 0.0 28.59 L1 -31.41 n/a 13.615 MHz 3.8 Qp 2.11 / 0.48 / 0.0 / 0.0 6.39 L1 -53.61 n/a 17.515 MHz 38.74 Qp 2.44 / 0.68 / 0.0 / 0.0 41.85 L1 -18.15 n/a 24.165 MHz 27.96 Qp 2.84 / 1.0 / 0.0 / 0.0 31.79 L1 -28.21 n/a 150.0 kHz 43.1 Av 0.23 / 0.2 / 0.0 / 0.0 43.53 L1 n/a -12.47 210.0 kHz 31.84 Av 0.26 / 0.12 / 0.0 / 0.0 32.22 L1 n/a -20.98 350.0 kHz 28.43 Av 0.32 / 0.1 / 0.0 / 0.0 28.85 L1 n/a -20.11 450.0 kHz 27.86 Av 0.35 / 0.1 / 0.0 / 0.0 28.31 L1 n/a -18.56 625.0 kHz 26.69 Av 0.41 / 0.16 / 0.0 / 0.0 27.26 L1 n/a -18.74 875.0 kHz 17.25 Av 0.47 / 0.2 / 0.0 / 0.0 17.92 L1 n/a -28.08 1.54 MHz 13.97 Av 0.65 / 0.1 / 0.0 / 0.0 14.72 L1 n/a -31.28 2.75 MHz 11.03 Av 0.9 / 0.1 / 0.0 / 0.0 12.03 L1 n/a -33.97 4.0 MHz 11.84 Av 1.12 / 0.1 / 0.0 / 0.0 13.06 L1 n/a -32.94 6.825 MHz 20.34 Av 1.51 / 0.14 / 0.0 / 0.0 21.99 L1 n/a -28.01 13.615 MHz -1.47 Av 2.11 / 0.48 / 0.0 / 0.0 1.12 L1 n/a -48.88 17.515 MHz 33.65 Av 2.44 / 0.68 / 0.0 / 0.0 36.76 L1 n/a -13.24 24.165 MHz 13.9 Av 2.84 / 1.0 / 0.0 / 0.0 17.73 L1 n/a -32.27 End of Conducted Scan CONDUCTED EMISSIONS Test Report #: WC905024 Run 1 Test Area: STS EUT Model #: S4E Date: 6/23/2009 EUT Serial #: N/A EUT Power: 240V/60Hz Temperature: 36.0 °C Test Method: FCC Part 15 Air Pressure: 98.0 kPa Customer: Landis & GYR Rel. Humidity: 40.0 % EUT Description: Electric Meter Notes: Data File Name: 5024.dat Page: 3 of 5 Tested by: Robert J Behringer Printed Signature Reviewed by: Printed Signature Measurement summary for limit1: FCC 15.207 CE QP (Qp) FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV) EUT Lead DELTA1 FCC 15.207 CE QP 150.0 kHz 52.94 Qp 0.23 / 0.2 / 0.0 / 0.0 53.37 N -12.63 625.0 kHz 40.2 Qp 0.41 / 0.16 / 0.0 / 0.0 40.77 N -15.23 210.0 kHz 45.54 Qp 0.26 / 0.12 / 0.0 / 0.0 45.92 L1 -17.28 450.0 kHz 38.5 Qp 0.35 / 0.1 / 0.0 / 0.0 38.95 N -17.92 17.515 MHz 38.74 Qp 2.44 / 0.68 / 0.0 / 0.0 41.85 L1 -18.15 350.0 kHz 39.78 Qp 0.32 / 0.1 / 0.0 / 0.0 40.2 N -18.76 875.0 kHz 31.24 Qp 0.47 / 0.2 / 0.0 / 0.0 31.91 N -24.09 4.0 MHz 27.86 Qp 1.12 / 0.1 / 0.0 / 0.0 29.08 N -26.92 24.165 MHz 27.96 Qp 2.84 / 1.0 / 0.0 / 0.0 31.79 L1 -28.21 2.75 MHz 26.36 Qp 0.9 / 0.1 / 0.0 / 0.0 27.36 N -28.64 6.825 MHz 26.94 Qp 1.51 / 0.14 / 0.0 / 0.0 28.59 L1 -31.41 1.54 MHz 23.6 Qp 0.65 / 0.1 / 0.0 / 0.0 24.35 N -31.65 13.615 MHz 22.44 Qp 2.11 / 0.48 / 0.0 / 0.0 25.03 N -34.97 CONDUCTED EMISSIONS Test Report #: WC905024 Run 1 Test Area: STS EUT Model #: S4E Date: 6/23/2009 EUT Serial #: N/A EUT Power: 240V/60Hz Temperature: 36.0 °C Test Method: FCC Part 15 Air Pressure: 98.0 kPa Customer: Landis & GYR Rel. Humidity: 40.0 % EUT Description: Electric Meter Notes: Data File Name: 5024.dat Page: 4 of 5 Test…
Text truncated - open the document above for the full version.
RADIATED EMISSIONS Test Report #: WC908471 Run 1 Test Area: LTS EUT Model #: 825 Date: 11/4/2009 EUT Serial #: 186C5 EUT Power: 15 VDC Temperature: 23.0 °C Test Method: FCC Pt 15 C Air Pressure: 99.0 kPa Customer: Landis & Gyr Rel. Humidity: 26.0 % EUT Description: 900 MHz Transmitter Notes: Data File Name: 8471.dat Page: 1 of 2 Tested by: Greg Jakubowski Printed Signature Reviewed by: Printed Signature List of measurements for run #: 1 FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV / m) POL / HGT / AZ (m)(DEG) DELTA1 FCC Pt 15.247 <1GHz 3m DELTA2 Maximized low, mid, and high fundamental carrier channels 902.058 MHz 102.25 Pk 2.55 / 22.46 / 0.0 / 0.0 127.26 V / 1.15 / 120 n/a n/a 914.93 MHz 101.56 Pk 2.61 / 22.85 / 0.0 / 0.0 127.01 V / 1.17 / 124 n/a n/a 927.832 MHz 100.5 Pk 2.67 / 23.23 / 0.0 / 0.0 126.4 V / 1.11 / 135 n/a n/a Begin scan 30 - 1000 MHz in restricted bands high channel No significant emissions detected in restricted bands low channel No significant emissions detected in restricted bands mid channel No significant emissions detected in restricted bands End scan 30 – 1000 MHz RADIATED EMISSIONS Test Report #: WC908471 Run 1 Test Area: LTS EUT Model #: 825 Date: 11/4/2009 EUT Serial #: 186C5 EUT Power: 15 VDC Temperature: 23.0 °C Test Method: FCC Pt 15 C Air Pressure: 99.0 kPa Customer: Landis & Gyr Rel. Humidity: 26.0 % EUT Description: 900 MHz Transmitter Notes: Data File Name: 8471.dat Page: 2 of 2 Tested by: Greg Jakubowski Printed Signature Reviewed by: Printed Signature Graph: 100MHz1GHz 0 10 20 30 40 50 60 FCC Pt 15.247 <1GHz 3m
RADIATED EMISSIONS Test Report #: WC908471 Run 3 Test Area: LTS EUT Model #: 825 Date: 11/4/2009 EUT Serial #: 186C5 EUT Power: 15 VDC Temperature: 23.0 °C Test Method: FCC Pt 15 C Air Pressure: 99.0 kPa Customer: Landis & Gyr Rel. Humidity: 26.0 % EUT Description: 2.4 GHz Zigbee transmitter Notes: Data File Name: 8471.dat Page: 1 of 4 Tested by: Greg Jakubowski Printed Signature Reviewed by: Printed Signature List of measurements for run #: 3 FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV / m) POL / HGT / AZ (m)(DEG) DELTA1 FCC 15.247 >1GHz 3m av. DELTA2 Low channel maximized 2.404 GHz 90.78 Pk 4.19 / 28.71 / 0.0 / 0.0 123.68 H / 1.74 / 47 -26.32* n/a Begin scan for emissions in the restricted bands, 1 - 18 GHz maximized 4.811 GHz 50.15 Av 6.5 / 32.79 / 43.15 / 0.27 46.56 V / 1.00 / 181 -7.44 n/a 4.811 GHz 56.85 Pk 6.5 / 32.79 / 43.15 / 0.27 53.26 V / 1.00 / 181 -0.74* n/a mid channel maximized 2.445 GHz 85.41 Av 4.22 / 28.8 / 0.0 / 0.0 118.43 H / 1.72 / 46 -31.57 n/a 2.445 GHz 88.85 Pk 4.22 / 28.8 / 0.0 / 0.0 121.87 H / 1.72 / 46 -28.13* n/a maximized 4.889 GHz 48.16 Av 6.58 / 32.94 / 43.09 / 0.45 45.04 V / 1.12 / 142 -8.96 n/a 4.889 GHz 55.7 Pk 6.58 / 32.94 / 43.09 / 0.45 52.58 V / 1.12 / 142 -1.42* n/a 7.334 GHz 56.48 Av 7.14 / 36.03 / 42.17 / 1.22 58.7 H / 1.29 / 28 4.7 n/a 7.334 GHz 62.8 Pk 7.14 / 36.03 / 42.17 / 1.22 65.02 H / 1.29 / 28 11.02* n/a high channel maximized 2.48 GHz 83.74 Av 4.24 / 28.88 / 0.0 / 0.0 116.86 H / 1.70 / 46 -33.14 n/a 2.48 GHz 87.55 Pk 4.24 / 28.88 / 0.0 / 0.0 120.67 H / 1.70 / 46 -29.33* n/a output power reduced 2.479 GHz 70.7 Pk 4.24 / 28.88 / 43.49 / 0.0 60.33 H / 1.60 / 40 -89.67* n/a 2.48 GHz 65.7 Pk 4.24 / 28.88 / 43.49 / 0.0 55.33 V / 1.60 / 30 -94.67* n/a RADIATED EMISSIONS Test Report #: WC908471 Run 3 Test Area: LTS EUT Model #: 825 Date: 11/4/2009 EUT Serial #: 186C5 EUT Power: 15 VDC Temperature: 23.0 °C Test Method: FCC Pt 15 C Air Pressure: 99.0 kPa Customer: Landis & Gyr Rel. Humidity: 26.0 % EUT Description: 2.4 GHz Zigbee transmitter Notes: Data File Name: 8471.dat Page: 2 of 4 Tested by: Greg Jakubowski Printed Signature Reviewed by: Printed Signature List of measurements for run #: 3 FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV / m) POL / HGT / AZ (m)(DEG) DELTA1 FCC 15.247 >1GHz 3m av. DELTA2 no spurious detected RADIATED EMISSIONS Test Report #: WC908471 Run 3 Test Area: LTS EUT Model #: 825 Date: 11/4/2009 EUT Serial #: 186C5 EUT Power: 15 VDC Temperature: 23.0 °C Test Method: FCC Pt 15 C Air Pressure: 99.0 kPa Customer: Landis & Gyr Rel. Humidity: 26.0 % EUT Description: 2.4 GHz Zigbee transmitter Notes: Data File Name: 8471.dat Page: 3 of 4 Tested by: Greg Jakubowski Printed Signature Reviewed by: Printed Signature Measurement summary for limit1: FCC 15.247 >1GHz 3m av. (Av) FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV / m) POL / HGT / AZ (m)(DEG) DELTA1 FCC 15.247 >1GHz 3m av. 7.334 GHz 56.48 Av 7.14 / 36.03 / 42.17 / 1.22 58.7 H / 1.29 / 28 4.7 4.811 GHz 50.15 Av 6.5 / 32.79 / 43.15 / 0.27 46.56 V / 1.00 / 181 -7.44 4.889 GHz 48.16 Av 6.58 / 32.94 / 43.09 / 0.45 45.04 V / 1.12 / 142 -8.96 2.445 GHz 85.41 Av 4.22 / 28.8 / 0.0 / 0.0 118.43 H / 1.72 / 46 -31.57 2.48 GHz 83.74 Av 4.24 / 28.88 / 0.0 / 0.0 116.86 H / 1.70 / 46 -33.14 2.404 GHz 90.78 Pk 4.19 / 28.71 / 0.0 / 0.0 123.68 H / 1.74 / 47 -26.32* 4.811 GHz 56.85 Pk 6.5 / 32.79 / 43.15 / 0.27 53.26 V / 1.00 / 181 -0.74* 2.445 GHz 88.85 Pk 4.22 / 28.8 / 0.0 / 0.0 121.87 H / 1.72 / 46 -28.13* 4.889 GHz 55.7 Pk 6.58 / 32.94 / 43.09 / 0.45 52.58 V / 1.12 / 142 -1.42* 7.334 GHz 62.8 Pk 7.14 / 36.03 / 42.17 / 1.22 65.02 H / 1.29 / 28 11.02* 2.48 GHz 87.55 Pk 4.24 / 28.88 / 0.0 / 0.0 120.67 H / 1.70 / 46 -29.33* 2.479 GHz 70.7 Pk 4.24 / 28.88 / 43.49 / 0.0 60.33 H / 1.60 / 40 -89.67* RADIATED EMISSIONS Test Report #: WC908471 Run 3 Test Area: LTS EUT Model #: 825 Date: 11/4/2009 EUT Serial #: 186C5 EUT Power: 15 VDC Temperature: 23.0 °C Test Method: FCC Pt 15 C Air Pressure: 99.0 kPa Customer: Landis & Gyr Rel. Humidity: 26.0 % EUT Description: 2.4 GHz Zigbee transmitter Notes: Data File Name: 8471.dat Page: 4 of 4 Tested by: Greg Jakubowski Printed Signature Reviewed by: Printed Signature Graph: 1GHz10GHz100GHz 40 50 60 70 80 90 100 110 120 130 140 150 FCC 15.247 >1GHz 3m av. Av-measurements Pk-measurements
RADIATED EMISSIONS Test Report #: WC908471 Run 4 Test Area: LTS EUT Model #: 825 Date: 11/4/2009 EUT Serial #: 186C5 EUT Power: 15 VDC Temperature: 23.0 °C Test Method: FCC Pt 15 C Air Pressure: 99.0 kPa Customer: Landis & Gyr Rel. Humidity: 26.0 % EUT Description: 2.4 GHz Zigbee transmitter Notes: 2.4 GHz transmitter - antenna 2 Data File Name: 8471.dat Page: 1 of 3 Tested by: J. T. Schneider Printed Signature Reviewed by: Printed Signature List of measurements for run #: 4 FREQ LEVEL (dBuV) CABLE / ANT / PREAMP / ATTEN (dB) FINAL (dBuV / m) POL / HGT / AZ (m)(DEG) DELTA1 FCC B >1G 3 M peak DELTA2 FCC B >1GHz 3m ave 2.405 GHz 123.3 Pk 4.19 / 28.71 / 43.46 / 0.0 112.74 V / 1.70 / 130 n/a n/a 2.405 GHz 125.5 Pk 4.19 / 28.71 / 43.46 / 0.0 114.94 H / 2.00 / 300 n/a n/a 2.445 GHz 124.9 Pk 4.22 / 28.8 / 43.48 / 0.0 114.44…
Text truncated - open the document above for the full version.
6436 County Road 11 · Pequot Lakes, Minnesota · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 101.00 mW |

Utility Meter Transceiver Module
Equipment Class
DTS - Digital Transmission System
FOCUS AX Modular Gridstream