  3. TS5-EB300HP

TS5-EB300HPTRANSMITTER BEACON FOR TRACKING OFFENDERS

Sendum Wireless Corp.
TRANSMITTER BEACON FOR TRACKING OFFENDERS - FCC ID TS5-EB300HP - Sendum Wireless Corp.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 30, 2012
Application Purpose
Original Equipment
Date of Application
Jan 30, 2012
Equipment Note
TRANSMITTER BEACON FOR TRACKING OFFENDERS
Frequency Range
314.21000000 - 314.36000000
Company
Sendum Wireless Corp.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

The Beacon Preface BI ExacuTrack ® One Officer’s Reference Guide Copyright © 2009, BI Incorporated All Rights Reserved Printed in USA BI prepared this guide for use by BI customers only. All comments concerning the contents of this guide should be directed to BI’s Marketing Department, 6400 Lookout Road, Boulder, CO 80301, USA. No part of this work covered by copyright may be reproduced in any form either graphically, electronically, mechanically; including photocopying, recording, taping, or storage in an information retrieval system without prior written permission from BI. Trademarks and Patents The following are registered trademarks of BI Incorporated: BI BI logo BI ExacuTrack BI ExacuTrack logo Technical Support For technical support when using BI’s monitoring center, contact the BI GuardCenter: BI GuardCenter 800 Main Street, Suite 501 Anderson, Indiana 46016 1‐800‐666‐3145 FAX 1‐765‐649‐3148 For technical support when using an agency monitoring center, contact BI Incorporated: BI Incorporated 6400 Lookout Road Boulder, CO 80301 1‐800‐241‐9924 Waste Electrical and Electronic Equipment (WEEE) All electrical products that reach the duration of their functioning capabilities must be returned to BI Incorporated for recycling. United States FCC, Part 15 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications made by the user to this equipment that are not expressly approved by BI Incorporated could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and beacon. Connect the equipment into an outlet on a circuit different from that to which the beacon is connected. Consult the dealer or an experienced radio/TV technician for help. Industry Canada Certification The equipment represented herein meets Industry Canada procedural and specification requirements for certification. The certification identification number is displayed on the equipment model identification plate prefixed by the acronym IC. The acronym “IC” only signifies that the Industry Canada technical specifications were met. Operation and EME Exposure The equipment represented herein is designed to comply with the following national and international standards and guidelines regarding exposure of human beings to radio frequency electromagnetic energy (EME): United States Federal Communications Commission, Code of Federal Regulations; 47 CFR part 2 sub‐part J. American National Standards Institute (ANSI)/Institute of Electrical and Electronics Engineers (IEEE). C95. 1‐1992. Institute of Electrical and Electronics Engineers (IEEE). C95. 1‐1999 Edition. International Commission on Non‐Ionizing Radiation Protection (ICNIRP) 1998. Ministry of Health (Canada). Safety Code 6. Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 kHz or 300 GHz, 1999. Australian Communications Authority Radiocommunications (Electromagnetic Radiation ‐ Human Exposure) Standard 2003. ANATEL, Brasil Regulatory Authority, Resolution 303 (July 2, 2002) “Regulation of the limitation of exposure to electrical, magnetic, and electromagnetic fields in the radio frequency range between 9 kHz and 300 GHz.” “Attachment to Resolution 303 from July 2, 2002.” Electromagnetic Interference/Compatibility Nearly every electronic device is susceptible to electromagnetic interference (EMI) if inadequately shielded, designed or otherwise configured for electromagnetic compatibility. Facilities To avoid electromagnetic interference and/or compatibility conflicts, obey all facility posted notices about cellular phones. Hospitals or health care facilities may be using equipment that is sensitive to external RF energy. Aircraft Per FAA regulations cellular phones should be turned off when on board an aircraft. Any use of a radio product must be in accordance with applicable regulations per airline crew instructions. Medical Devices If a person using the ExacuTrack One system also uses any personal medical devices (i.e. pacemaker, hearing aid, etc.), consult the manufacturer of the personal medical device to determine if it is adequately shielded from RF energy. A physician may be able to assist in obtaining this information. Operational Warnings There are certain areas where you want to avoid operation of any radio product. Potentially Explosive Atmospheres Turn off any radio product prior to entering any area with a potentially explosive atmosphere unless it is a radio product type especially qualified for use as “Intrinsically Safe” (for example, Factory Mutual, CSA, or UL ‐approved). Do not remove, install, or charge batteries in such areas. Sparks in a potentially explosive atmosphere can cause an explosion or fire resulting in bodily injury or even death. Note: The areas with potentially explosive atmospheres referred to above include fueling areas, such as below decks on boats, fuel or chemical transfer or storage faci…

Text truncated - open the document above for the full version.

Cover Letter(s)

DATE: Dec. 01, 2011 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: We, Sendum Wireless Corporation, hereby authorize Jonathan Hughes of Celltech Labs Inc. to act on our behalf in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Any and all acts carried out by Jonathan Hughes of Celltech Labs Inc. on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S. C. 853(a). Sincerely, ___________________ Henry Seto Senior RF Engineer/Manager Sendum Wireless Corp. Sendum

Cover Letter(s)

Jan 16, 2012 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: TS5-EB300HP Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram Schematic Diagrams Operational Description Parts List EB300HP Block Diagram (Confidential).pdf EB300HP R2.3-01 Schematic (Confidential).pdf EB300HP Technical Descriptions-Rev1 (Confidential).pdf EB300HP Parts List (Confidential).pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Finally, these devices are going on individuals in the Criminal Justice System. We try to keep only absolutely necessary knowledge about the devices in the hands of the individuals wearing the equipment. The availability of this information and pictures would provide them un-necessary knowledge of the equipment’s functionality. Sincerely, Henry Seto Senior RF Designer Sendum

ID Label/Location Info

Celltech Project No.: 1152 DEVICE LABELING REQUIREMENTS (FCC §2.925, §15.19 & IC RSS-GEN) Celltech Project No.: 1152

Test Report

Test Report Serial No.: 011612TS5-T1152-E15F Report Issue Date: Jan. 27, 2012 Measurement Date(s): January 17-19, 2012 Report Revision No.: 1.1 (2nd Release) FCC Rule Part(s): 47 CFR §2; §15.231a FCC Test Firm Reg. No.: Accredited IC Standard(s): RSS-210 RSS-Gen IC Test Site No.: IC 3874A-1 Test Lab Certificate No. 2470.01 Applicant: Sendum Wireless Corporation FCC ID: TS5-EB300HP IC: 6234A-EB300HP DUT Model: EB300HP DUT Type: Beacon Transmitter for Tracking Offenders Tx Freq.: 315.285 MHz 2012 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc. Page 1 of 16 DECLARATION OF COMPLIANCE RF MEASUREMENT REPORT FCC & IC Name CELLTECH LABS INCORPORATED Test Lab Information Address 21-364 Lougheed Road, Kelowna, British Columbia V1X 7R8 Canada FCC Accredited (ISO 17025 - A2LA Test Lab Certificate No. 2470.01) Test Lab Registration No.(s) IC 3874A-1 Name SENDUM WIRELESS CORPORATION Applicant Information Address 4500 Beedie Street, Burnaby, British Columbia V5J 5L2 Canada FCC 47 CFR Part 2; 15.231(a) IC RSS-210 Issue 8; RSS-Gen Issue 3 Standard(s) & Procedure(s) ANSI C63.4-2003 FCC Part 15 Security / Remote Control Transmitter (DSC) Device Classification(s) IC Low-power Licence-exempt Radiocommunication Device (Category 1) Application Type FCC/IC New Certification FCC ID: TS5-EB300HP Device Identifier(s) IC: 6234A-EB300HP Device Under Test (DUT) Beacon Transmitter for Tracking Offenders Device Model(s) Tested EB300HP Measurement Date(s) January 17-19, 2012 Test Sample Receipt Date January 16, 2012 6300908 (Occ. BW & Emissions Tests) - Identical Prototype Test Sample Serial No.(s) None (Duty Cycle Measurement) - Identical Prototype Transmit Frequency Band 314.21 - 314.36 MHz Transmit Operating Frequency 314.285 MHz Modulation Type(s) FSK Max. Transmit Duty Cycle 0.05 % (9ms on-time / 17-20s off-time) Antenna Type(s) Tested Internal Monopole (Transmit Diversity) Antenna Gain Specification -4 dBi Power Source(s) Tested Alkaline Battery (D-size x2) This wireless device has demonstrated compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in FCC 47 CFR Rule Part 2 and Rule Part 15.231(a); Industry Canada RSS-210 Issue 8 and RSS-Gen Issue 3; and ANSI C63.4-2003. I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. The results and statements contained in this report pertain only to the device(s) evaluated. This report shall not be reproduced partially or in full without the prior written approval of Celltech Labs Inc. Test Report Approved By Sean Johnston Lab Manager Celltech Labs Inc. Test Report Serial No.: 011612TS5-T1152-E15F Report Issue Date: Jan. 27, 2012 Measurement Date(s): January 17-19, 2012 Report Revision No.: 1.1 (2nd Release) FCC Rule Part(s): 47 CFR §2; §15.231a FCC Test Firm Reg. No.: Accredited IC Standard(s): RSS-210 RSS-Gen IC Test Site No.: IC 3874A-1 Test Lab Certificate No. 2470.01 Applicant: Sendum Wireless Corporation FCC ID: TS5-EB300HP IC: 6234A-EB300HP DUT Model: EB300HP DUT Type: Beacon Transmitter for Tracking Offenders Tx Freq.: 315.285 MHz 2012 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc. Page 2 of 16 TABLE OF CONTENTS 1.0 SCOPE ................................................................................................................................................................ 4 2.0 REFERENCES .................................................................................................................................................... 4 2.1 Normative References ......................................................................................................................................... 4 3.0 PASS/FAIL CRITERIA......................................................................................................................................... 4 4.0 FACILITIES AND ACCREDITATIONS ................................................................................................................ 5 5.0 GENERAL INFORMATION ................................................................................................................................. 5 5.1 Applicant Information ........................................................................................................................................... 5 5.2 DUT Description .................................................................................................................................................. 5 5.3 Mode(s) of Operation Tested............................................................................................................................... 5 5.4 Modification(s) ..................................................................................................................................................... 5 Appendix A Transmission Time / Silent Period Between Transmission ............................................................. 6 Appendix B Occupied Bandwidth........................................................................................................................ 8 Appendix C Field Strength of the Fundamental and Spurious Emissions ........................................................ 10 FIGURES Figure A.4 -1 - Setup Drawing – Transmission Time / Silent Period Between Transmission................................... 6 Figure B.4-1 - Setup Drawing – Occupied Bandwidth............................................................................................... 8 Figure C.5-1 - Setup Drawing – Field Strength of the Fu…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SETUP PHOTOGRAPHS DUT Orientation X DUT Orientation X DUT Orientation Y DUT Orientation Z

Contact Information

Applicant

Henry Seto(Engineer)
[email protected]6044543774Fax: 6044375726

Test Firm

Celltech Labs. IncBen Hewson
[email protected]250-765-7650Fax: 250-765-7645

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231314.21 MHz - 314.36 MHz-
Confidentiality
Long Term

Other Applications from Sendum Wireless Corp.

TS5-PTONE

PTOne

Mar 09, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
Ankle Worn Digital Transceiver - FCC ID TS5-OM500A - Sendum Wireless Corp.
TS5-OM500A

Ankle Worn Digital Transceiver

May 23, 2021

Equipment Class

PCB - PCS Licensed Transmitter
GLOBAL ASSET TRACKING DEVICE - FCC ID TS5-6055M-GT300 - Sendum Wireless Corp.
TS5-6055M-GT300

GLOBAL ASSET TRACKING DEVICE

Aug 30, 2012

Equipment Class

PCB - PCS Licensed Transmitter
DUAL-BAND CDMA 1xRTT ASSET TRACKING DEVICE - FCC ID TS5-6055M-PT300 - Sendum Wireless Corp.
TS5-6055M-PT300

DUAL-BAND CDMA 1xRTT ASSET TRACKING DEVICE

Dec 22, 2011

Equipment Class

PCB - PCS Licensed Transmitter
Mobile tracking device - FCC ID TS5-6050M-GT200 - Sendum Wireless Corp.
TS5-6050M-GT200

Mobile tracking device

May 24, 2007

Equipment Class

PCB - PCS Licensed Transmitter