RE101_GE-Compat_DWS_Instructions.doc Page 1 of 3 29 -Jun-11 www.ResolutionProducts.com Wireless Security Solutions RE101 GE-Compatible Standard Door / Window Features • For sensing things that open or separate. • Magnet and Internal reed switch operation. • 2 supplemental hardwire zones. o GE-compatible version reports 2 nd zone to 2 nd ID. • Cover tamper. • Strong, reliable RF signal. • 10-15 year battery life on CR123A battery. • Low Battery indication. Key Instructions • Battery “+” faces towards spring. • No end-of-line resistors on hardwire zones. • Panels assume hardwire zone alarm is state in which contact was enrolled. • Center hardwire terminal is common. • Reed switch and terminal closest to (outer) it are 1 st ID • Inner terminal is 2 nd ID. • Enrolling: 1 st ID: Reed switch and outer terminal zone are enroll ed by tamper switch. 2 nd ID: Inner terminal zone is enrolled by holding dow n tamper while installing battery. Operation • Magnetic and 1 st (outer) hardwire zone (1 st ID) Alarm, when... ... magnet is pulled away from reed switch. ... contact changes to alarm. Tamper, when cover is opened. Supervisories, every hour. • 2 nd (inner) hardwire zone (2 nd ID) Alarm: when contact changes to alarm condition. Tamper: none. Supervisory: every hour. RE101_GE-Compat_DWS_Instructions.doc Page 2 of 3 29 -Jun-11 www.ResolutionProducts.com Specifications Magnet trip distance: 1 inch nominal Mounting hardware: # 4 or #6 screws Replacement Battery: CR123A 1550mAH Temperature Range: 0F to 120F Housing dimensions: 3.3x1.4x1.1 inches Specifications subject to change without notice. Internal Picture Outer Terminal Zone Center Common Terminal Inner Terminal Zone 2 nd ID Magnetic Reed Switch 1 st ID RE101_GE-Compat_DWS_Instructions.doc Page 3 of 3 29 -Jun-11 www.ResolutionProducts.com Notices “GE”, “Honeywell”, and “DSC” are trademarks owned b y General Electric Company, Honeywell International Inc., and Tyco Safety Products Canada LTD, respectively. Resolution Products, Inc. products will function wi th one of either GE, DSC or Honeywell systems. However, no Resolution product is produce d by, endorsed by, nor is officially associated with GE, Honeywell or DSC. Resolution recommends verifying proper enrollment and operation, per control panel installation instr uctions, at installation. Warranty Resolution Products, Inc. will replace products tha t are defective in their first year. FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference that may b e received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user's authority to operate this equipment . FCC ID: U5X-RE101X IC Notice This device complies with Industry Canada license-e xempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, includ ing interference that may cause undesired operation of the device. Cet appareil est conforme avec d’Industrie Canada R SS standard exempts de licence. Son fonctionnement est soumis aux deux conditions s uivantes: 1. Ce dispositif ne peut causer des interférences, et 2. Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dis positif. IC: 8310A-RE101X
June 25, 2011 RE: Confidentiality Request for U5X-RE101X/8310A-RE101X To Whom It May Concern: Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality RequestedExhibit Short Term PermanentBlock Diagrams Short TermExternal Photos Short Term Permanent* 1 Internal Photos Short Term PermanentOperation Description/Theory of Operation Short Term PermanentParts List & Placement/BOM Short Term PermanentTune-Up Procedure Short Term PermanentSchematics Short TermTest Setup Photos Short Term Permanent*User’s Manual *Note: ______(Insert Explanation as Necessary)______ Resolution Products, Inc. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period 1 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.” of ___(specify number of days not to exceed 180) 2 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By:__________________________ Paul Saldin, Vice President (Signature/Title 3 )(Print name) 2 - Please refer to http://atcb.com/publicdocs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
Exhibit A RE101X External Photos
Exhibit B RE101X ID Label Photo
Exhibit C RE101X Internal Photos
Resolution Products, Inc. Security Transmitter FCC ID: U5X-RE101X Certification Test Report June 27, 2011 U5X-RE101X Resolution Products, Inc.06/27/11Page 1 of 8 Test Report 226 Locust Street, Suite 4 Hudson, WI 54016 Contents 1. Introduction.................................................................................................................................................................3 2. Statement of Compliance............................................................................................................................................3 2.1. FCC Part 2 §2.907................................................................................................................................................3 2.2. FCC Part 2 §2.911................................................................................................................................................3 2.3. FCC Part 2 §2.913................................................................................................................................................3 2.4. FCC Part 2 §2.915................................................................................................................................................3 2.5. FCC Part 2 §2.925................................................................................................................................................3 2.6. FCC Part 2 §2.943, 2.945....................................................................................................................................3 2.7. FCC Part 2 §2.947................................................................................................................................................4 2.8. FCC Part 2 §2.948................................................................................................................................................4 2.9. FCC Part 2 §2.1033..............................................................................................................................................4 3. Discussion of Laboratory Measurements and Rules Compliance...............................................................................5 3.1. FCC Part 15 §15.231(a)(1)..................................................................................................................................5 3.2. FCC Part 15 §15.231(a)(3)..................................................................................................................................5 3.3. FCC Part 15 §15.231(a)(4)..................................................................................................................................6 3.4. FCC Part 15 §15.231(a)(5)..................................................................................................................................6 3.5. FCC Part 15 §15.231(b).......................................................................................................................................6 3.5.1. Raw Field Strength Limits............................................................................................................................6 3.5.2. Duty Cycle Correction Factor and Resulting Limits.....................................................................................6 3.5.3. Measured Radiated Field Strength Data.......................................................................................................7 3.6. FCC Part 15 §15.231(c).......................................................................................................................................7 U5X-RE101X Resolution Products, Inc.06/27/11Page 2 of 8 Test Report 226 Locust Street, Suite 4 Hudson, WI 54016 1.Introduction This device is a small sensor for use in a wireless security system. The unit is powered by a 3V lithium battery. The device measures 1 x 1.25 x 3” and weighs approximately 1.8 ounces. The device transmits transmission packets for the purpose of alerting a security system. A microcontroller monitors the inputs for activations and transmits four data packets when valid activations are detected. Inputs for the various models consist of, for example, a reed switch, a tamper switch, a temperature sensor, a tilt detector, and a motion detecting switch. In the absence of external activations, a set of three supervision transmissions is sent once per hour. Certification is requested under FCC Rules, Part 15, Subpart C, Paragraph 15.231. 2.Statement of Compliance Specific sections of FCC Rules Part 2 that require information or listing are given below. 2.1.FCC Part 2 §2.907 This is an application for certification of original equipment 2.2.FCC Part 2 §2.911 a)This application has been filed electronically using form 731. b)All required information has been supplied in this application and its attachments. c)This application has been electronically signed by an officer of Resolution Products, Inc. d)The technical test data has been signed by the agency performing the testing. e)Signature supplied in appropriate block on form 731. f)Processing fee has been paid. g)Signatures have been supplied electronically. 2.3.FCC Part 2 §2.913 a)This application has been filed electronically. b)Appropriate fees have been filed electronically. c)Equipment samples shall be supplied as requested. 2.4.FCC Part 2 §2.915 We are requesting a grant of certification. This application shows compliance with the technical standards. 2.5.FCC Part 2 §2.925 A label shall be affixed to each piece of equipment, showing the FCC identifier. The label shall read “FCC ID: U5X- RE101X”. See Exhibit B for a photograph showing the label and location on the device. 2.6.FCC Part 2 §2.943, 2.945 Sample production equipment shall be submitted to the FCC upon request. 2.7.FCC Part 2 §2.947 a)Measurement procedure follows ANSI C63.4: 2009. b)A description of utilized test equipment is contained in the report. 2.8.FCC Part 2 §2.948 Radiated…
Text truncated - open the document above for the full version.
Engineering Solutions & Electromagnetic Compatibility Services FCC 15.231 Radiated Test Data for Model: RE101 319.5 MHz DWS (RTL barcode: 19906) for Resolution Engineering RTL Project Number 2010199 Test Engineer: Jon Wilson This report may not be reproduced, except in full, without the full written approval of Rhein Tech Laboratories, Inc. and Resolution Engineering. Test results relate only to the item tested. These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANSI-ASQ National Accreditation Board/ACLASS. Refer to certificate and scope of accreditation AT-1445. Rhein Tech Laboratories, Inc. Client: Resolution Engineering 360 Herndon Parkway Model: RE101 Suite 1400 FCC ID: N/A Herndon, VA 20170 Standards: FCC Part 2, 15 http://www.rheintech.com Report #: 2010199 2 of 6 Radiated Emissions Test Data – FCC Limits / 3m Distance Emission Frequency (MHz) Test Detector Antenna Polarity (H/V) Analyzer Reading (dBuV) Site Correction Factor (dB/m) Emission Level (dBuV/m) Limit (dBuV/m) Margin (dB) Pass/ Fail Remarks 319.507 Pk V 62.4 28.5 90.9 95.9 -5.0 Pass 639.012 Pk V 60.0 -6.9 53.1 75.9 -22.8 Pass 958.525 Pk H 61.2 -1.7 59.5 75.9 -16.4 Pass 1,278.027 Pk V 55.0 3.3 58.3 74.0 -15.7 Pass 2 1,597.523 Pk H 47.4 7.0 54.4 74.0 -19.6 Pass 1 1,917.007 Pk H 46.2 11.0 57.2 75.9 -18.7 Pass 2,236.500 Pk H 52.3 -3.7 48.6 74.0 -25.4 Pass 1 2,556.000 Pk V 57.1 6.0 63.1 75.9 -12.8 Pass 2,875.500 Pk H 41.3 20.8 62.1 74.0 -11.9 Pass 1 3,195.000 Pk V 23.8 39.3 63.1 75.9 -12.8 Pass Remarks: 1. FCC/IC Restricted Band Limit 2. IC Restricted Band Limit Test Procedure Radiated emissions of the harmonics were tested at three meters. The EUT was tested in the three orthogonal planes with the receive antenna in both polarities. The emissions were maximized per ANSI C63.4:2003 8.3.1.2; that is, the measurement antenna height was varied between 1 and 4 m, and the EUT was rotated through 360° on a rotating turntable until the maximum emissions were found. Both horizontal and vertical measurement antenna polarizations were used. A resolution bandwidth of 100 kHz was used for frequencies less than 1000 MHz, and a resolution bandwidth of 1 MHz was used for frequencies greater than or equal to 1000 MHz. The video bandwidth was set to a value at least three times greater than the resolution bandwidth. EUT Disposition The EUT was adapted to continuously transmit for testing purposes. Rhein Tech Laboratories, Inc. Client: Resolution Engineering 360 Herndon Parkway Model: RE101 Suite 1400 FCC ID: N/A Herndon, VA 20170 Standards: FCC Part 2, 15 http://www.rheintech.com Report #: 2010199 3 of 6 Radiated Emissions Test Equipment Part Manufacturer Model Serial Number RTL Bar Code Calibration Due Date Amplifier (20 MHz-2 GHz) Rhein Tech Laboratories, Inc. PR-1040 900905 900905 4/10/2011 Bilog Periodic Antenna (25 MHz-2 GHz) Schaffner Chase CBL6112 2099 900791 12/12/2010 EMI Receiver RF Section (9 kHz-6.5 GHz) Hewlett Packard 85462A 3325A00159 900913 6/8/2011 RF Filter Section (100kKHz-6.5 GHz) Hewlett Packard 85460A 3330A00107 900914 6/8/2011 Spectrum Analyzer Hewlett Packard 8596EM 3826A00144 901215 11/23/2010 Amplifier RTL PR-1040 N/A 900811 4/10/2011 Horn Antenna, 2.0- 4.0 GHz EMCO 3161-02 9804-1044 900772 6/13/2011 Emissions Testing Software Rhein Tech Laboratories, Inc. Automated Emission Tester Rev. 14.0.2 N/A N/A Test Personnel: Jon Wilson October 11, 2010 Test Engineer Signature Date of Test Rhein Tech Laboratories, Inc. Client: Resolution Engineering 360 Herndon Parkway Model: RE101 Suite 1400 FCC ID: N/A Herndon, VA 20170 Standards: FCC Part 2, 15 http://www.rheintech.com Report #: 2010199 4 of 6 Test Configuration Photographs X-Axis Rhein Tech Laboratories, Inc. Client: Resolution Engineering 360 Herndon Parkway Model: RE101 Suite 1400 FCC ID: N/A Herndon, VA 20170 Standards: FCC Part 2, 15 http://www.rheintech.com Report #: 2010199 5 of 6 Y-Axis Rhein Tech Laboratories, Inc. Client: Resolution Engineering 360 Herndon Parkway Model: RE101 Suite 1400 FCC ID: N/A Herndon, VA 20170 Standards: FCC Part 2, 15 http://www.rheintech.com Report #: 2010199 6 of 6 Z-Axis
U5X-RE101X 8310A-RE101X Test Setup Photos
226 Locust Street · Hudson, Wisconsin · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 319.5 MHz - 319.5 MHz | - |

Wireless Alarm Panel
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Glass Break Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Glass Break Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Glass Break Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Siren
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter