Wireless MIMO LAN Card - Wireless PC Card (CardBus) - Wireless Mini PCI Module - Wireless PCI Adapter IEEE 802.11b/g User Manual Rev. 1.0 Mar. 2007 FCC Information to User FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Guidelines for Human Exposure This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Regulatory Compliance Information This section includes user requirements for operating this product in accordance with National laws for usage of radio spectrum and operation of radio devices. Failure of the end-user to comply with the applicable requirements may result in unlawful operation and adverse action against the end-user by the applicable National regulatory authority. FCC Requirements for Operation in the United States Radio Frequency Interference Warnings & Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following methods: Model: Wireless PC Card FCC ID: Model: Wireless Mini PCI Adapter FCC ID: Model: Wireless PCI Adapter FCC ID: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and the receiver • Connect the equipment into an electrical outlet on a circuit different from that which the radio receiver is connected • Consult the dealer or an experienced radio/TV technician for help. Modifications made to the product could void the user's right to operate the equipment. Europe - EU Declaration of Conformity Note: CE certificate is not applied for module. R&TTE Compliance Statement This equipment complies with all the requirements of DIRECTIVE 1999/5/CE OF THE EUROPEAN PARLIAMENT AND THE COUNCIL of March 9, 1999 on radio equipment and telecommunication terminal Equipment and the mutual recognition of their conformity (R&TTE). The R&TTE Directive repeals and replaces in the directive 98/13/EEC (Telecommunications Terminal Equipment and Satellite Earth Station Equipment) As of April 8, 2000. Safety This equipment is designed with the utmost care for the safety of those who install and use it. However, special attention must be paid to the dangers of electric shock and static electricity when working with electrical equipment. All guidelines of this and of the computer manufacture must therefore be allowed at all times to ensure the safe use of the equipment. Requirements For Operation in the European Community Countries of Operation and Conditions of Use in the European Community The user should run the utility program provided with this product to check the current channel of operation and confirm that the device is operating in conformance with the spectrum usage rules for European Community countries as described in this section. This device is intended to be operated in all countries of the European Community. Operation Using 2.4 GHz Channels in France The following radio channel usage limitations apply in France. The radio spectrum regulator in France, Autorité de regulation des telecommunications (ART), enforces the following rules with respect to use of 2.4GHz spectrum in various locations in France. Please check ART's web site for latest requirements for use of the 2.4GHz band in France: http://www.art-telecom.fr/eng/index.htm. This device is a 2.4 GHz low power RF device intended for home and office use in EU and EFTA member states. In some EU / EFTA member states some restrictions may apply. Please contact local spectrum management authorities for further details before putting this device into operation. When operating in the following metropolitan regions (départements) in France, this device may be operated under the following conditions: • Indoors using any channel in the 2.4-2.4835 GHz band (Channels 1-13) • Outdoors using channels in the 2.4-2.454 GHz band (Channels 1-7) When operating outside of the following regions (départements) in France such as Guadeloupe, Martinique, St Pierre et Miquelon, Mayotte, this product can be operated under the following conditions: • Indoors using any channel in the 2.4-2.4835 GHz band (Channels 1-13) • Outdoors using any channel in the 2.4-2.4835 GHz band (Channels 1-13) When operating outside of the following regions (départements) in France such as Ré union and Guyana, this product can be operated under the following conditions: • Indoors using any channel in the 2.4-2.4835 GHz band (Channels 1-13) • Outdoors using channels in the 2.420-2.4835 GHz band (Channels 3-13) Please refer to the ART web site for further details. Metropolitan Regions: Important Note: A WLAN device operating according to Section 15.247 on Channels 1-11 between 2400-2483.5 MHz must not have any user controls or software to al…
Text truncated - open the document above for the full version.
RT2529 RT2661 40 MHz Mini PCI Interface SST12LP15A
American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 April 20, 2007 RE: E-Top Network Technology FCC ID: U6AWM101M I have a few comments on this Application. Depending on your responses, kindly understand there may be additional comments. 1.) FYI: I see you have just uploaded revised photos. The FCC requires that all documents be separated into specific Exhibits. This means you cannot provide a single photo set. We are required to have separate Exhibits for External Photos, Internal Photos and Test Setup Photos. If any single document exceeds 4MB (the largest single size file accepted by the Commission), we will ask that you divide the photos into multiple files. Please be sure that all photos are clear enough to read the designators off the printed circuit board. Simple orthographic projection is preferred. 2.) The Block Diagram shows a single part RT2529 which contains an unidentified oscillator. Please review and identify by frequency on this Exhibit. 3.) Please indicate the country where the DofC was tested for FCC EMC compliance. 4.) Is the end user able to select a country code? 5.) FYI: Your detail about RF power over different channels and different data rates is perfect – please continue this table in all test reports. One word of caution – please do not depend too much on channel power measurements for accurate RF power measurement. If RF category “Portable” measurements are needed, you will need an absolute accuracy of less than 10% - I believe a spectrum analyzer is not capable of this resolution. 6.) MIMO RF power is expected to be a Composite power, but no details of how that is accomplished are presented. Please review and correct as needed. 7.) Please provide an RF Exposure Estimation (MPE) as a separate Exhibit. 8.) For the Radiated Restricted Bandedge test (15.205), it would be appreciated if a plot of 40MHz span, centered directly on 2400 and 2483.5 MHz be presented. Two plots should be presented for each band edge – one Peak and the second Average – with a 54dBuV limit as appropriate. 9.) Please provide a sample calculation demonstrating that your laboratory’s 3 meter test setup has adequate sensitivity to see to the 54dBuV average levels at 18GHz. Please include noise floor, cable loss, ACF, amplifiers, etc. William H. Graff President and Director of Engineering mailto: [email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.
William Graff From: Hermann Kuo [[email protected]] Sent: Tuesday, May 01, 2007 12:43 PM To: 'William Graff' Cc: [email protected]; [email protected]; [email protected]; [email protected] Subject: RE: www.AmericanTCB.com ATCB004823 | U6AWM101M | | | U6AWM101M_ATCB004823 5/2/2007 Dear Bill, Kindly check the reply below for comments on WM101M application. Thank you. Best Regards, Hermann 1.) FYI: I see you have just uploaded revised photos. The FCC requires that all documents be separated into specific Exhibits. This means you cannot provide a single photo set. We are required to have separate Exhibits for External Photos, Internal Photos and Test Setup Photos. If any single document exceeds 4MB (the largest single size file accepted by the Commission), we will ask that you divide the photos into multiple files. Please be sure that all photos are clear enough to read the designators off the printed circuit board. Simple orthographic projection is preferred. MLT: Noted 2.) The Block Diagram shows a single part RT2529 which contains an unidentified oscillator. Please review and identify by frequency on this Exhibit. MLT: Revised Block Diagram uploaded to “Block Diagram” folder 3.) Please indicate the country where the DofC was tested for FCC EMC compliance. MLT: Taiwan, R.O.C, by Max Light Technology. 4.) Is the end user able to select a country code? MLT: End users are not able to select a country code because the function of country code selections is already disabled by software on the device. 5.) FYI: Your detail about RF power over different channels and different data rates is perfect – please continue this table in all test reports. One word of caution – please do not depend too much on channel power measurements for accurate RF power measurement. If RF category “Portable” measurements are needed, you will need an absolute accuracy of less than 10% - I believe a spectrum analyzer is not capable of this resolution. MLT: Noted 6.) MIMO RF power is expected to be a Composite power, but no details of how that is accomplished are presented. Please review and correct as needed. MLT: This is a 1T2R architecture product. 7.) Please provide an RF Exposure Estimation (MPE) as a separate Exhibit. MLT: MPE uploaded to “Additional Information” folder 8.) For the Radiated Restricted Bandedge test (15.205), it would be appreciated if a plot of 40MHz span, centered directly on 2400 and 2483.5 MHz be presented. Two plots should be presented for each band edge – one Peak and the second Average – with a 54dBuV limit as appropriate. MLT: uploaded related information to “Additional Information” folder 9.) Please provide a sample calculation demonstrating that your laboratory’s 3 meter test setup has adequate sensitivity to see to the 54dBuV average levels at 18GHz. Please include noise floor, cable loss, ACF, amplifiers, etc MLT: uploaded related information to “Additional Information” folder -----Original Message----- From: William Graff [mailto:[email protected]] Sent: Friday, April 20, 2007 3:28 PM To: [email protected]; [email protected]; [email protected] Cc: [email protected]; [email protected]; [email protected]; [email protected] Subject: www.AmericanTCB.com ATCB004823 | U6AWM101M | | | U6AWM101M_ATCB004823 Regarding www.AmericanTCB.com application: ATCB ID: ATCB004823 FCC ID: U6AWM101M IC: TCF: Account name: MLTLAB Please see attached comments on this filing. Best Regards, Bill ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ~ William H. Graff, NARTE Certified ~ President and Director of Engineering ~ AmericanTCB, Inc. ~ 6731 Whittier Ave, ~ McLean, VA 22101 ~ mailto:[email protected] ~ Corporate Phone: (703) 847-4700 ~ Taiwan Office: (703) 310-6868 ~ Taiwan Mobile: +886 920399260 ~ SKYPE: whgraff ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 5/2/2007
Page:5/8 Report Number: MLT0702P15002 PHOTOGRAPHS OF EUT
Report Number: MLT0702P15002 Label Format: Label Position: Equipment Label Rear View
Page:6/8 Report Number: MLT0702P15002 Page:7/8 Report Number: MLT0702P15002 Page:8/8 Report Number: MLT0702P15002
WM101m MIMO Adapter MIMObility™ and 802.11n !""#$% & &' #( #)* $)+, -".// .+! ' ( -".//00 MIMO XR™ 1 2 1 3 4 5 2(35 2(3 1 -".// 6 -".// Understanding MRC-OFDM 7 (')8 + 9*: ; 9*: .""/& 9*: , #2, #3 : 9*: 9*: + : * .""< /= .""!: -- 7> #( * + ? 9*: + 4 8 # ') > @ * ') & A 9*: 0 23 * 2&9*:3 2&*:3 4 +& # ')2 ' 4 ) 3 9*: ') -".// -".// 8 &' 8 2 3 * 4 4 ' /+ @ + ' # 2*#3 B B&' # 4 …
Text truncated - open the document above for the full version.
SPECIFICATION FOR APPROVAL CUSTOMER DATE DESCRIPTION CUSTOMER P/N TOW0006A1 Part No. WANSHIH ELECTRONIC CO., LTD. 723 3F 72 WU KONG 6TH RD., WU KU INDUSTRIAL DISTRICT TAIPEI HSIEN, TAIWAN,R.O.C. TEL(02) 22988066 (5 LINE) FAX(02)22981102 93 03 11 Swivel Type1/4λ Dipole Antenna RP-SMA (M) (Black) 1 Table of Contents Table of Contents ......... 1 Specification ......... 2 Antenna Drawing ......... 3 Connector Drawing ......... 4 Electrical Properties Return Loss ......... 5 V. S . W. R ......... 6 Radiation Pattern ......... 7-8 Material Data Sheet Coaxial Cable ......... 9-11 Housing ......... 12 Hinge ......... 13 2 SPECIFICATION 1. Description The antenna is a Swivel Type Dipole Antenna 2. Customer 3. Model No. WSS002 4. Part No. TOW0006A 5. Standard IEEE 802.11b/g Wireless LAN 6. Antenna Profile 108 mm length (see Drawing) 7. Color : Black 8. Electrical Characteristics Operating Frequency 2.4~2.5Ghz Antenna Type 1/4λ Dipole Sleeve Polarization Type Linear Type of Radiation Toroidal Peak Gain 2.0 dBi Typical Impedance 50 Ohm nominal V.S.W.R. 2.0:1 Max. 9. Mechanical Characteristics Action Swivel Type Connector RP-SMA (M) Core N/A 10. Raw Material Coaxial Cable MIL-C-17 RG-178 B/U Housing TPU Hinge Polycarbonate 3 TOW0006 Black) 4 5 Electrical Properties Return Loss 2.8 GHz 10 dB/ -80 dB 20 dB MAGdB CH110 dB/REF0dB START2 GHzSTOP2.9 GHz100 MHz/ CPL FIL 10k10k FIL 10k10k S11 1 2 3 1: -36.99 dB 2.45 GHz 2: -18.16 dB 2.4 GHz 3: -19.58 dB 2.5 GHz 〈 0 dB 6 Electrical Properties V. S . W. R 2.1 GHz2.8 GHz 1 U/ 1 U 11 U SWRLINCH11 U/REF 1 U START2 GHzSTOP2.9 GHz100 MHz/ FIL 10k10k FIL 10k10k CPL S11 1 2 3 1: 1.048 U 2.45 GHz 2: 1.288 U 2.4 GHz 3: 1.201 U 2.5 GHz 〈 1U 7 Electrical Properties Radiation Pattern – H Plane 8 Electrical Properties Radiation Pattern – E Plane 9 Coaxial Cable Data Sheet RG-178 SPECIFICATION FOR APPROVAL A30178B001 200 30V RG-178B/U SIZE: 7/0.102 SCCS RECOGNIZED: WONDERFUL HI-TECH CO.,LTD OFFICE72WU KONG 6TH ROAD, WU KU IND. DISTRICT TAIPEI HSIEN,TAIWAN TEL(02)22988033 FAX(02)22988031-2 FAC TO RY17 PEI YUAN ROAD, CHUNG-LI IND. PARK TAIWAN, R.O.C. TEL(03)4527777 FAX(03)4517214 10 WONDERFUL HI-TECH CO., LTD SPECIFICATION STYLE 200 30V COAXIAL DOCUMENT NO : A30178B001 SIZE RG-178B/U ESTABLISHED DATE: 2003/02/13 STANDARD : MIL-C-17 Size AWG 30 Material ---- Silver-Coated Copper Clad Steel Conductors No. ---- 7 Conductors Size mm 0.102 Conductor O.D. mm 0.30 Average Thickness mm 0.28 Diameter mm 0.86 Material ---- FEP Insulation Color ---- Clear Material ---- Silver-Coated Copper Construction mm 16 / 3 / 0.10 Braid Coverage % 95 Average Thickness mm 0.25 Diameter mm 1.80 0.05 Material ---- FEP Jacket Color ---- Brown Marking Drawing AK001/210X297/1.0 PAGE : 1 EDITION : 1.1 REVISED DATE : MAKER : C.Y.CHEN CONFIRM : S.N.WONG APPROVAL : W.J.WANG 11 WONDERFUL HI-TECH CO., LTD SPECIFICATION Electrical & Physical Properties Item RG-178B/U Rating Temp Voltage 200 30V Conductor Resistance 838 OHM/KM/20 MAX. Insulation Resistance 3000 MEGA OHM/KM MIN. Dielectric Strength AC 1.0 KV/Minute Spark Test 2.0 KV Tensile Strength 2500 PSI MIN.( 1.76 Kg / ) Unaged Elongation 200% MIN. Tensile StrengthUNAGED MIN 75%(168HRS×232) Insulation Aged Elongation UNAGED MIN 75%(168HRS×232) Tensile Strength 2500 PSI MIN.( 1.76 Kg / ) Unaged Elongation 200% MIN. Tensile StrengthUNAGED MIN.75%(168HRS×232) Jacket Aged Elongation UNAGED MIN.75%(168HRS×232) Nom. Impedance 50 Ohms Nom. Capacitance 95.8 pF/m Nom. Vel. of Prop. 69.5% VSWR (0 – 6 GHZ) UNDER 1.3 100MHz 1GHz 1.8GHz 2.4GHz 5.2GHz 6GHz Attenuation (dB/100m) 46 155 295 340 505 550 AK001/210X297/1.0 PAGE : 2 EDITION : 1.1 REVISED DATE : MAKER : C.Y.CHEN CONFIRM : S.N.WONG APPROVAL : W.J.WANG 12 Housing Material Data Sheet z Housing - TPU 13 z Hinge(Base/Holder)- Polycarbonate(PC)
55 44 33 22 11 D D C C B B A A TRD YBINTABDEVSELBCBE2BC CLKIR D YBCBE1BMRSTBFRAMEBCBE3BPAR AD[0..31] REQB STOPBCBE0BPERRBSERRBID SELGNTBRFTXDIS#LD2P_24GCLKRUNBLD1P_ACT TX_BB_I+R F_PERX_BB0_Q-TX_BB_I-RX_BB0_I+40MIRX_BB0_I-RX_BB0_Q+ TX_BB_Q- TX_BB_Q+ SYNCLK IR EF LD2_YN5 RADIO_PD#RX_BB1_Q+RX_BB1_I-RX_BB1_Q-RX_BB1_I+SYNDAT0RF_LE-0#RFTR_PESYNDAT1RF_LE-1#PA_PE_GTSSI_AG PA_RFINGRFIN G_BRFIN G_A TR_SWN0 TR_SW0 Title Size Document Number R e v Date: Sheet o f MPCI-RT2600-V10ST-X-HP.SCH 1.0 WM101m_V10_20070322 B 1 5 Friday, March 23, 2007 E-TOP NETWORK TECHNOLOGY INC. Mini PCI I/F and Power4-MINIPCI.SCH AD[0..31] CCLK CBE3BCBE2BCBE1BCBE0B PAR FRAMEB IRDYB TRDYB DEVSELB MRSTB INTAB STOPB SERRBPERRB IDSEL RFTXDIS# REQB GNTB LD2P_24G CLKRUNB LD1P_ACT LD2_YN5 MAC RT26613-RT2661-MPCI AD[0..31]CCLKCBE3BPARFRAMEBIRDYBMRSTBINTABREQBSTOPBCLKRUNB TX_BB_Q+ TX_BB_Q- TX_BB_I+ TX_BB_I- RX_BB0_Q+ RX_BB0_I+ RX_BB0_I- RX_BB0_Q- TSSI_AG RF_PE RFTR_PERF_LE-0# SYNDAT0 SYNCLK PA_PE_G RADIO_PD# 40MI CBE2BCBE1BCBE0BTRDYBDEVSELBGNTBSERRBPERRBIDSEL IREF RFTXDIS#LD2P_24GLD1P_ACTLD2_YN5 RX_BB1_Q+ RX_BB1_Q- RX_BB1_I- RX_BB1_I+ RF_LE-1# SYNDAT1 TR_SWN0 TR_SW0 Transceiver RT2529 1-RT2529-XTAL RF_PERFTR_PERF_LE-0#SYNDAT0SYNCLK40MIRADIO_PD#RX_BB0_I-RX_BB0_I+RX_BB0_Q-RX_BB0_Q+TX_BB_I-TX_BB_I+TX_BB_Q-TX_BB_Q+ RFING_B PA_RFING IREFRX_BB1_I+RX_BB1_I-RX_BB1_Q-RX_BB1_Q+RF_LE-1#SYNDAT1 RFING_A TSSI_AGTR_SW0TR_SWN0 PA SST12LP15A and TX/RX 2-PA-SST12LP15A-LNA PA_PE_G RFING_B PA_RFING RFING_A RFTR_PE 55 44 33 22 11 D D C C B B A A R F I N G+ G N D G N DG N D R F OU T G-R F I N G- TXR_VO3 C _ V C C TXR_VO3 V E C _ V C C VC T RL1 R F R C R X_BB0_I+ R X_BB0_I+ R X _BB0_I- R X _BB0_I- G N D R AD I O_PD # R AD I O_PD # TXR_VO2 V C C AV C C B G N D 3. 3VD TX_BB_I+TX_BB_I-TX_BB_Q+TX_BB_Q- TX_BB_Q+TX_BB_I+TX_BB_Q-TX_BB_I- R X_BB0_Q+ R X_BB0_Q+ R X _BB0_Q- R X _BB0_Q- R X_BB1_I+ R X_BB1_I+ R X _BB1_I- R X _BB1_I- R X _BB1_Q- R X _BB1_Q- R X_BB1_Q+ R X_BB1_Q+ G N D R F T R _ PER F _PE R F OU T G+R F I N 2G- G N DG N D R F I N 2G+ V C C B S Y N C LK R F _LE -0#S YN D AT 1 R F _LE -1# R F _LE -1# I R EF S Y N C LKS YN D AT 0 R F _LE -0# S YN D AT 1 S YN D AT 0 I R EF TXR_VO3TO T S SI_AG G N D G N D G N D G N D G N D R F LD OBP R F LD OBP V C C A V C C A V C C A G N D V C C A V C C A G N D V C C B TXR_VO3 1. 8 VA G N D V C C B V C C B TXR_VO2 V C C A V C C A V C C A TXR_VO2 V C C A TXR_VO2 V C C A G N D G N D V C C A3. 3 VAG N D R F _ V C C D G N D G N D 40MX1 F 4 0M G N D 40MX2 TXR-40MO V C C B G N D G N D G N D G N D G N D T R _SW N 0 T R _S W0 R F I N 2_GR F I N _G R F I N G_1 R F I N G_B P A_R F I N G G N D R F I N G_A T R _SW N G N D R F I N G_2 G N D G N D T R A1 T RA G N D T RB T R B1 G N D 4 0MI G N D G N D T R _SW R F I N G_A P A_R F I N G R X_BB0_I+R X_BB0_I- R AD I O_PD # TX_BB_I+TX_BB_I-TX_BB_Q-TX_BB_Q+R X_BB0_Q+R X_BB0_Q-R X_BB1_I-R X_BB1_I+R X_BB1_Q+R X_BB1_Q- R F _PE R F T R _PE R F I N G_B R F _LE-1#S Y N C LKS Y N D AT 1S Y N D AT 0 I R E F R F _LE-0# T SSI_AG T R _SW0T R _SW N0 40MI G N D V C C A G N D G N D V C C A G N D G N D G N D G N D 3. 3VD V C C B G N D G N D G N D G N D G N D G N DG N D V C C A G N D G N D G N D V C C B G N D G N D G N D V C C A G N D G N D 1. 8VA V C C B V C C A V C C B G N D 3. 3VAG N DV C C A G N D G N DG N D G N D G N D GND G N D G N D G N D Title Size D oc um ent N umber R e v D at e: Sheet o f 1-RT2529-XTAL.SCH 1. 0 WM101m_V10_20070322 C 2 5 F riday , M arch 23, 2007 E-TOP NETWORK TECHNOLOGY INC. XTAL: CL=15pF, Co=1.5pF C 245 4. 7uF / 6.3V 12 L65 6. 8nH 1 2 C 491 10uF / 6.3V 1 2 C 461 0. 01uF 1 2 C 15 33pF 1 2 C 446 100pF 12 L 8 2. 7nH 1 2 C 503 100pF 12 C 419 0. 01uF 1 2 C 17 10pF / N I 12 C 511 10pF / N I 12 C 495 1. 5pF 1 2 C 27 33pF / N I 12 L63 0 ohm / N I 1 2 R 282 1K 1 2 C 452 3. 3nF 12 C 426 1 nF 12 C 465 10pF 1 2 R 18 0 ohm / N I 1 2 C 24 1 0pF 1 2 C 499 1. 8pF 1 2 C 413 10uF / 6.3V 1 2 L55 2. 7nH 1 2 C 514 10pF / N I 12 C 340 10pF 1 2 C 504 0. 01uF 12 R 259 68pF 12 C 442 1 nF 12 R 160 2 7 1 2 R 281 1K 1 2 C 515 10pF 1 2 C 414 10uF / 6.3V 1 2 U2 uPG2179TB OUT1 3 GND 2 OUT2 1 VC2 6 IN 5 VC1 4 5x3.2 U 50 XTAL/5x3.2/40MHz 12 43 C 512 10pF / N I 12 C 464 1nF 1 2 L54 1. 8nH 1 2 L10 4. 7nH 1 2 C 513 10pF / N I 12 C 443 27pF 1 2 L26 100nH 1 2 C 417 10pF 12 R 15 3 6 1 2 R 10 0 ohm 1 2 R 260 68pF 12 R 12 3 6 1 2 C 244 0. 1uF 12 U 47 R T 2529 RFinP2 1 RFinM2 2 VCC2 3 RFoutP2 4 RFoutM2 5 VCC3 6 RFinP5 7 RFinM5 8 VCC4 9 RFoutP5 10 RFoutM5 11 RFinP2b 12 RFinM2b 13 VCC5 14 RFinP5b 15 RFinM5b 16 TR_PE 17 RF_PE 18 VCC6 19 NC 20 Temp_Out 21 Bias_VCCb 22 LO_Vcc 23 Core_Vcc 24 LO_Vc 25 VP1 26 VCCa 27 LD_fo 28 I_OutM 42 Base_Vcc2 41 Q_OutP 40 Q_OutM 39 Base_Vcc3 38 I_OutPb 37 I_OutMb 36 Base_Vcc4 35 Q_OutPb 34 Q_OutMb 33 VCCd 32 X1/OSCI 31 X2 30 CLKout 29 Iref 55 Bias_Vcc 56 LE 54 Data 53 CLK 52 Datab 51 LEb 50 DAC_VCC 46 I_InP 48 I_InM 47 Base_Vcc1 49 Q_InP 45 Q_InM 44 I_OutP 43 LDO_Out2 59 LDO_Bypass 58 LDO_Out3 60 LDO_Out1b 61 LDO_In 62 LDO_Out1 63 LDO_PE 57 VCC1 64 GND 65 C 496 10pF 12 C 409 10uF / 6.3V 1 2 C 48 1. 2pF 1 2 C 453 15pF 12 U3 uPG2179TB OUT1 3 GND 2 OUT2 1 VC2 6 IN 5 VC1 4 C 439 4. 7pF 12 R 20 0 ohm 1 2 C 2 8 10uF / 6.3V 1 2 L66 2. 2nH 1 2 C 45 1. 8pF 1 2 C 36 1 nF 12 C 37 1 nF 12 C 428 1 nF 12 C 454 0. 01uF 12 R 267 18K 1 2 C 468 10pF 1 2 C 437 10pF 1 2 R 115 0 ohm 1 2 55 44 33 22 11 D D C C B B A A G N D G N D G N D G N D P A_R F I N G P AF G N DG N D BPF _OG PAI N _G G N D G V C C A 33VD A1 GVLN A LN AI A R F I N GA V C C A R F I N G_A GVLN A G N D 33VD B2G N D T R _PE LN AI B 33VD B1 G N D 33VD A3 R F I N G2 P U GVLN A 33VD B3 R F I N G_B G N D G N D G N D G N D G N D G N D G N D G N D R F T R _ PE G N D 33VD A2 PAO _G VB1VB2 D ET _R EF D E T1 G N D G N D G N DG N D M P AO_G G N D V C C 2 3. 3VD G N D V C C 1 3. 3VD R F I N A_GR F I N B_G PA_P E_G G N D G N D P A_R F I N G PA_PE_G R F I N G_B R F I N G_A R F T R _PE G N DG N D G N DG N D G N D G N D 3 . 3VD G N D G N D G N D G N D G N DG N D G N D G N D G N D G N D V C C A G N D G N D G N D G N D G N D G N D G N D G N D G N D G N D Title Size…
Text truncated - open the document above for the full version.
Page: 1 /61 Report Number: MLT0702P15002-02 (FCC : Part 15 Subpart C (15.247) / ANSI C63.4-2003) Product :IEEE802.11g MIMO Mini PCI Adapter Trade Name :E-TOP(The other see Appendix II) Model No. :WM101m (The other see Appendix II) Applicant :E-Top Network Technology Inc. Applicant Address :No.82, Gongye 2nd Rd., Tainan City 70955, Taiwan, R.O.C. Page: 2 /61 Report Number: MLT0702P15002-02 Report Number MLT0702P15002-02 Applicant E-Top Network Technology Inc. Product IEEE802.11g MIMO Mini PCI Adapter Sample Received Date 2007/02/08 Report Prepared By Jesse Tien Signature Date Prepared 2007/02/09 ~ 2007/03/24 Report Authorized By Roger Chen Signature Date Authorized 2007/03/29 Test By Max Light Technology Co., Ltd. Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan., R.O.C. Office : Tel: 886-2-2363-2447 Fax: 886-2-236…
Text truncated - open the document above for the full version.
Room 5, 8F, Section 3 · Taipei · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 25.00 mW |

11n DUAL-BAND USB DONGLE
Equipment Class
NII - Unlicensed National Information Infrastructure TX
11N DUAL-BAND USB DONGLE
Equipment Class
NII - Unlicensed National Information Infrastructure TX
300+300MBPS GIGABIT SERVER ROUTER
Equipment Class
NII - Unlicensed National Information Infrastructure TX
SMART 300N BROADBAND ROUTER
Equipment Class
NII - Unlicensed National Information Infrastructure TX
11n WALL ROUTER
Equipment Class
DTS - Digital Transmission System