Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RemoteControl OperationManual 1.Productinstruction Thisproductisawirelessremotecontrol,andisgenerousandattractiveinappearance withscientificinternalcircuitdesign.WithSMTchipcomponents,ithasthecharacteristics ofhighstability,lowpowerconsumption,etc. Featuresofremotecontrol: (1)Compactandattractiveinappearance,fullpanelslidecoverdesigntoavoidfalse triggering; (2)WirelessRFtechnology,longtransmissiondistance,non-directional,high transmissionsensitivity,nosignalblocking; (3)Theshellismadeofhigh-qualityABSflameretardantmaterial,beingsafeandreliable touse; (4)WithLEDworkingstateindication. 2.Buttonoperationinstruction 1Exposurecontrol Continuouslypresstheexposurecontrolbuttontoentertheremotecontrolexposure process. 2Beamlimitercontrol Beamlimiterlightfieldlampcontrolbutton. 3Inchingcontrol Presstheforwardcontrolbutton,thenthewholemachinemovesslightlyforwards;press thebackwardcontrolbutton,thenthewholemachinemovesslightlybackwards;whenthe trolleyhandleortheox-headinchingcontrolbuttonisenabled,theremotecontrolinching isdisabled. 3.Technicalparameters Maintechnicalparameters: TechnicalParameters WorkingvoltageDC12V Workingfrequency433.90Mhz±250KHz Size120mm*52mm*18mm Powersupply(drycell)[Model]8LR932 [Voltage]12v [Specification]Diameter10mm*Height28mm [Exp.]Longservicelifeof3years FCCRegulations: FCCID:U72MTMGLM Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothe followingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2) thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay causeundesiredoperation. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassB digitaldevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedto providereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation. Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnot installedandusedinaccordancewiththeinstructions,maycauseharmful interferencetoradiocommunications.However,thereisnoguaranteethat interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescause harmfulinterferencetoradioortelevisionreception,whichcanbedeterminedby turningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreofthefollowingmeasures: —Reorientorrelocatethereceivingantenna. —Increasetheseparationbetweentheequipmentandreceiver. —Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe receiverisconnected. —Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Changesormodificationsnotexpresslyapprovedbythemanufacturercouldvoidthe user’sauthoritytooperatetheequipment. ICNotice ThisdevicecomplieswithIndustryCanadalicense-exemptRSSstandard(s).Operationis subjecttothefollowingtwoconditions: (1)thisdevicemaynotcauseinterference,and (2)thisdevicemustacceptanyinterference,includinginterferencethatmaycause undesiredoperationofthedevice. ThisClassBdigitalapparatuscomplieswithCanadianICES-003. IC:7027A-MTMGLM RemarqueIC CetappareilestconformeauxNormesRSSd'IndustyCanada.Sonutilisationestsoumise àdeuxconditions: (1)Cedispositifnepeutpasprovoquerd'interférences,et (2)Cedispositifdoitacceptertouteslesinterférencesreçues,ycomprislesinterférences susceptiblesdeprovoquerunfonctionnementnonsouhaité. CetappareildeclasseBestconformeàlanormecanadienneICES-003. IC:7027A-MTMGLM
Global R&D Center (Shanghai) Rev 1/26/2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: March 6, 2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID:U72MTMGLM_ Carestream Health, Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Randall Masline, Senior EMC/Wireless Engineer GlobalR&DCenter(Shanghai) Rev1/26/2023 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:March6,2023 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:U72MTMGLM CarestreamHealth,Inc.(“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredListasanentityproducing“covered”equipment. Sincerely, RandallMasline,SeniorEMC/WirelessEngineer
Carestream Health Inc. B1049 Ridge Road West Rochester, NY 14615 USA Date: March 8, 2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: U72MTMGLM US Agent – Attestation Statement / Part 2.911(d)(7) Carestream Health Inc. certifies, that as of March 8, 2023, we have designated Carestream Health Inc. to accept service of process on our behalf for FCC ID: U72MTMGLM Carestream Health Inc. accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. Carestream Health Inc. accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of Carestream Health Inc. for FCC ID: U72MTMGLM Designated Agent Information: Company Name: Carestream Health Inc. FRN: 0016195265 Address: B1049 Ridge Road West, Rochester NY 14615 Contact Person: Randall Masline Phone: 585-627-8907 Email: [email protected] Sincerely, Company: Carestream Health Inc. Designated Agent: Carestream Health Inc. Company Representative: Randall Masline Designated Agent Representative: Randall Masline Signature: Signature:
Global R&D Center (Shanghai) POWER OF ATTORNEY DATE: March 7, 2023 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 We, the undersigned, hereby authorize TA Technology (Shanghai) Co., Ltd./Michelle Qu on our behalf, to apply to FCC on our equipment for FCC ID: U72MTMGLM. Any and all acts carried out by TA Technology (Shanghai) Co., Ltd. on our behalf shall have the same effect as acts of our own. Sincerely, Randall Masline, Senior EMC/Wireless Engineer
Global R&D Center (Shanghai) Request for Confidentiality Date: March 6, 2023 Subject: Confidentiality Request for: _ FCC ID: U72MTMGLM_/ IC:7027A- MTMGLM____ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 1 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Permanent NII Software Security Info Short Term Permanent Test Setup Photos Short Term Permanent* User’s Manual *Note: Carestream Health, Inc. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of _____ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TCB in the event information regarding the product or the product is made available to the public. TCB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, Company: Carestream Health, Inc. Print Name: Randall Masline, Senior EMC/Wireless Engineer Signature:
EUT Appearance Report No.: R2110A0882 TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 1 of 3 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. EUT Appearance EUT Appearance Report No.: R2110A0882 TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 2 of 3 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. EUT Appearance Report No.: R2110A0882 TA Technology (Shanghai) Co., Ltd. TA-MB-01-032E Page 3 of 3 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. a: EUT Picture 1: Constituents of EUT
LabelLocation
Internal photo FCC ID: U72MTMGLM TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 1 of 2 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Internal photo Internal photo FCC ID: U72MTMGLM TA Technology (Shanghai) Co., Ltd. TA-MB-01-033E Page 2 of 2 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.
ReportNo.:RFI-LAB-RF-202303-CC31 QP030-E41 Page1of9 TestingReport CustomerName:ShenzhenLanmageMedicalTechnologyCo.,Ltd. ProductName:Remotecontrol SampleModel:RMT1 ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2023.3.23 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202303-CC31 QP030-E41 Page2of9 Version VersionNo.DateDescriptionFormulateApproval A02023.3.23Forthefirsttime,formulateZkrisEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults......................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................7 3.3.1Typicalfreespaceefficiencyandgain......................................................................7 3.3.2Typicalfreespaceradiationpattern...........................................................................8 (Thefollowingisblank)................................................................................................................9 ReportNo.:RFI-LAB-RF-202303-CC31 QP030-E41 Page3of9 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202303-CC31 QP030-E41 Page4of9 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2023.3.142025.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2022.5.132023.5.12 1.4Testenvironment Temperature 23.4°C Humidity 58%RH Pressure 100.16kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202303-CC31 QP030-E41 Page5of9 2.SampleInformation 2.1Clientinformation Manufacturer ShenzhenLanmageMedicalTechnologyCo.,Ltd. Address LanmageImagingScience&TechnologyPark, TangtouRoad,Shiyan,Shenzhen Contacts / Tel / E-mail / Manufacturer / 2.2DescriptionofEUT(S) ProductName Remotecontrol SampleModel RMT1 AntennaSize / SerialNo. / AntennaType PCBAntenna TestItem Antennagain;Efficiency;Radiationpattern FrequencyRange 428-438MHz ReceivedDate 2023.3.22 TestDate 2023.3.23 Remark ThelengthoftheRFcableis45mm ReportNo.:RFI-LAB-RF-202303-CC31 QP030-E41 Page6of9 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202303-CC31 QP030-E41 Page7of9 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty Antennagain±0.72dB Radiationefficiency±0.72dB 3.3 Testdata 3.3.1Typicalfreespaceefficiencyandgain Frequency/MHz 428429430431432433434435436437438 PeakGain/dBi -8.29-8.04-7.82-7.58-7.35-7.16-6.95-6.76-6.56-6.34-6.18 Efficiency/% 5.115.465.836.166.516.917.257.597.988.408.76 ReportNo.:RFI-LAB-RF-202303-CC31 QP030-E41 Page8of9 3.3.2Typicalfreespaceradiationpattern (1)X-ZPlane(unit:dBi): (2)Y-ZPlane(unit:dBi): ReportNo.:RFI-LAB-RF-202303-CC31 QP030-E41 Page9of9 (3)X-YPlane(unit:dBi): (4)TypicalFreeSpace3DRadiationPatternat438MHz(unit:dBi): -------------------------------------------------End------------------------------------------------ (Thefollowingisblank)
Prepared by: Xu Ying Approved by: Xu Kai TA Technology (Shanghai) Co., Ltd. Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China TEL: +86-021-50791141/2/3 FAX: +86-021-50791141/2/3-8000 RF TEST REPORT Applicant Carestream Health, Inc. FCC ID U72MTMGLM Product Remote control Brand Carestream Model RMT1 Report No. R2110A0882-R1V3 Issue Date April 4, 2023 TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC CFR47 Part 15C (2022). The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. RF Test Report Report No.: R2110A0882-R1V3 TA Technology (Shanghai) Co., Ltd. TA-MB-01-117R Page 2 of 26 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENT 1. Test Laboratory ............................................................................................................................ 5 1.1. Notes of the test report ......................................................................................................... 5 1.2. Test facility ........................................................................................................................... 5 1.3. Testing Location ................................................................................................................... 5 2. General Description of Equipment under Test .............................................................................. 6 2.1. Applicant and Manufacturer Information ............................................................................... 6 2.2. General information .............................................................................................................. 6 3. Applied Standards ........................................................................................................................ 7 4. Test Configuration ........................................................................................................................ 8 5. Test Case Results ........................................................................................................................ 9 5.1. Transmission and Deactivation Time ................................................................................... 9 5.2. Occupied Bandwidth .......................................................................................................... 12 5.3. Unwanted Emission ........................................................................................................... 14 5.4. Conducted Emission .......................................................................................................... 22 6. Main Test Instruments ........................................................................................................ ........ 24 ANNEX A: The EUT Appearance ...................................................................................................... 25 ANNEX B: Test Setup Photos ........................................................................................................... 26 RF Test Report Report No.: R2110A0882-R1V3 TA Technology (Shanghai) Co., Ltd. TA-MB-01-117R Page 3 of 26 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Version Revision description Issue Date Rev.0 Initial issue of report. March 2, 2023 Rev.1 Update Antenna Gain in Page 6. March 28, 2023 Rev.2 Update description and data. March 31, 2023 Rev.3 Update description and data. April 4, 2023 Note: This revised report (Report No.: R2110A0882-R1V3) supersedes and replaces the previously issued report (Report No.: R2110A0882-R1V2). Please discard or destroy the previously issued report and dispose of it accordingly. RF Test Report Report No.: R2110A0882-R1V3 TA Technology (Shanghai) Co., Ltd. TA-MB-01-117R Page 4 of 26 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Summary of measurement results Number Test Case Clause in FCC rules Verdict 1 Transmission and Deactivation Time 15.231(a) PASS 2 Occupied bandwidth 15.231(c) PASS 3 Unwanted Emissions 15.231(b),15.209 PASS 4 Conducted Emissions 15.207 NA Date of Testing: January 12, 2023~ January 13, 2023 and April 3, 2023 Date of Sample Received: October 12, 2021 Note: PASS: The EUT complies with the essential requirements in the standard. FAIL: The EUT does not comply with the essential requirements in the standard. All indications of Pass/Fail in this report are opinions expressed by TA Technology (Shanghai) Co., Ltd. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. RF Test Report Report No.: R2110A0882-R1V3 TA Technology (Shanghai) Co., Ltd. TA-MB-01-117R Page 5 of 26 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the test report This report shall not be reproduced in full or partial, without the written approval of TA Technology (Shanghai) Co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American …
Text truncated - open the document above for the full version.
Pr TA T SA repared by: We Techn Building 3, N AR E Applic FCC ID Produ Brand Model Repo r Issue i Fangying ology No.145, Jinta TEL: +8 FAX: +86-0 xemp cant C D U ct R C R rt No. R Date A y (Shan ang Rd, Pudo 86-021-50791 021-5079114 ption Carestrea U72MTM Remote c Carestrea RMT1 R2110A0 April 4, 20 Approved nghai) ong Shangha 1141/2/3 41/2/3-8000 Eval am Healt MGLM control am 0882-S1V 023 by: Fan Guangc ) Co., L ai, P.R.China luatio h, Inc. V2 chang Ltd. a on SAR exemption evaluation Report No.: R2110A0882-S1V2 TA Technology (Shanghai) Co., Ltd. TA-MB-01-008S Page 2 of 10 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Table of Contents 1 Test Laboratory ............................................................................................................................... 4 1.1 Notes of the Test Report ......................................................................................................... 4 1.2 Test Facility ............................................................................................................................. 4 1.3 Testing Location ...................................................................................................................... 4 1.4 Laboratory Environment .......................................................................................................... 4 2 Description of Equipment Under Test ............................................................................................. 5 3 Test Specification, Methods and Procedures ................................................................................. 7 4 Output Power ................................................................................................................................. 8 5 Standalone SAR Test Exclusion Considerations ............................................................................ 9 ANNEX A: The EUT Appearance ......................................................................................................... 10 SAR exemption evaluation Report No.: R2110A0882-S1V2 TA Technology (Shanghai) Co., Ltd. TA-MB-01-008S Page 3 of 10 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Version Revision description Issue Date Rev.0 Initial issue of report. March 2, 2023 Rev.1 Update Antenna Gain and data. March 28, 2023 Rev.2 Update description and data. April 4, 2023 Note: This revised report (Report No.: R2110A0882-S1V2) supersedes and replaces the previously issued report (Report No.: R2110A0882-S1V1). Please discard or destroy the previously issued report and dispose of it accordingly. SAR exemption evaluation Report No.: R2110A0882-S1V2 TA Technology (Shanghai) Co., Ltd. TA-MB-01-008S Page 4 of 10 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1 Test Laboratory 1.1 Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA Technology (Shanghai) Co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2 Test Facility FCC (Designation number: CN1179, Test Firm Registration Number: 446626) TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform measurements. 1.3 Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: Building 3, No.145, Jintang Rd, Pudong Shanghai, P.R.China City: Shanghai Post code: 201201 Country: P. R. China Contact: Fan Guangchang Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: http://www.ta-shanghai.com E-mail: [email protected] 1.4 Laboratory Environment Temperature Min. = 18°C, Max. = 25 °C Relative humidity Min. = 30%, Max. = 70% Ground system resistance < 0.5 Ω Ambient noise is checked and found very low and in compliance with requirement of standards. Reflection of surrounding objects is minimized and in compliance with requirement of standards. SAR exemption evaluation Report No.: R2110A0882-S1V2 TA Technology (Shanghai) Co., Ltd. TA-MB-01-008S Page 5 of 10 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 2 Description of Equipment Under Test Client Information Applicant Carestream Health, Inc. Applicant address 1049 Ridge Road West, Rochester,New York Manufacturer Carestream Health, Inc. Manufacturer address 1049 Ridge Road West, Rochester,New York General Technologies Application Purpose Original Grant EUT Stage Identical Prototype Model RMT1 Lab internal SN R2110A0882/S01 Hardware Version D Software Version N/A Antenna Type Internal Antenna Date of Testing February 2, 2023 Date of Sample Received October 12, 2021 Note: The EUT is sent from the applicant to TA and the information of the EUT is declared by the applicant. SAR exemption evaluation Report No.: R2110A0882-S1V2 TA Technology (Shanghai) Co., Ltd. TA-MB-01-008S Page 6 of 10 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Wireless Technology and Frequency Range Wireless Technology Modulation Tx (MHz) Rx (MHz) RFID / 433.90MH±250KHz / SAR exemption evaluation Report No.: R2110A0882-S1V2 TA Technology (Shanghai) Co., Ltd. TA-MB-01-008S Page 7 of 10 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 3 Test Specification, Methods and Procedures Reference Standards KDB 447498 D01 General RF Exposure Guidance v06 SAR exemption evaluation Report No.…
Text truncated - open the document above for the full version.
RF Test Setup Report No: R2110A0882 TA Technology (Shanghai) Co., Ltd. TA-MB-01-107R Page 1 of 3 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. Part15C Test Setup RF Test Setup Report No: R2110A0882 TA Technology (Shanghai) Co., Ltd. TA-MB-01-107R Page 2 of 3 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 30MHz-1GHz RF Test Setup Report No: R2110A0882 TA Technology (Shanghai) Co., Ltd. TA-MB-01-107R Page 3 of 3 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1GHz-18GHz Picture 1 Radiated Emission Test Setup
Building 3,No.145,Jintang Rd,Pudong · Shanghai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.9 MHz - 433.9 MHz | - |

X-RAY IMAGING FOR HEATHCARE
Equipment Class
NII - Unlicensed National Information Infrastructure TX
WiFi transmitter
Equipment Class
DTS - Digital Transmission System
Laser Imager
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Film Printer for Medical Images using 13.56 MHz Transmitter RFID
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
DRYVIEW CHROMA Imaging System incorporating RFID
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter