Rev 2/17/2023 Microlife Corporation Fede ral Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: December 5, 2025 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: U7I‐BP3KV1‐5W‐2 Microlife Corporation (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Microlife Corporation (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti‐virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti‐virus software pursuant to DA‐24‐886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end‐user or third parties cannot install additional software on this device. Sincerely, Signature: Printed name: Jimmy Deng 2025.12.08
Rev 2/17/2023 Microlife Corporation Fede ral Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: December 5, 2025 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: U7I‐BP3KV1‐5W‐2 Microlife Corporation (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Signature: Printed name: Jimmy Deng 2025.12.08
Rev 1/26/2023 Microlife Corporation Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: December 5, 2025 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID : U7I‐BP3KV1‐5W‐2 Applicant FRN: 0016306045 Microlife Corporation (“the applicant”) certifies that, as of the date of the filing of the application, Microlife USA Inc is our designated U.S. agent for service of process for the above referenced FCC ID. Microlife Corporation accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission‐related proceeding involving the equipment. Microlife USA Inc accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Microlife USA Inc. FRN: 0033 599390 Address: 1617 Gulf to Bay Blvd., 2 nd Floor Clearwater, FL 33755 Contact Person: Jason Frieders Phone:1‐727‐451‐0484 Email: [email protected] Sincere ly, Mic rolife Corporation Microlife USA Inc. printed name: Jimmy Deng printed name: Jason Frieders Signature: Signature: 2025.12.08 Jan 7, 2026
Rev 11/20/07 Microlife Corporation F ederal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: U7I-BP3KV1-5W-2 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name (Block Diagram, Schematics, Operational Description) (Block Diagram.pdf, Schematics.pdf, Operational Description.pdf) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request that the information attached to this application be temporarily confidential for 180 days as outlined below: Exhibit Type File Name External Photos Internal Photos Test Setup Photos User manual External Photos.pdf Internal Photos.pdf Test Setup Photos.pdf User manual.pdf Sincerely, Signature: printed name: Jimmy Deng 2025.12.08
\\10.20.1.36\安规部\OGA Colleague\Ferry\E盘\2025年\鸿富外测\待签字的FCC ID文件\BP3KV1-5W_FCC 签字文件\FCC POA Letter.docx Microlife Corporation Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: December 5, 2025 SUBJECT: FCC Application for FCC ID: U7I-BP3KV1-5W-2 To Whom It May Concern: We, the undersigned, hereby authorize Liting Nong at Centre Testing International Group Co., Ltd / Building C, Hongwei Industrial Park Block 70, Bao'an District, Shenzhen, China on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Liting Nong at Centre Testing International Group Co., Ltd / Building C, Hongwei Industrial Park Block 70, Bao'an District, Shenzhen, China on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Si gnature: printed name: Jimmy Deng 2025.12.08
1:1 51.4 mm 1 5 . 4 m m 2 . 0 m m Blood Pressure Monitor Model: BP3KV1-5W Distributed by: Microlife USA, Inc. Clearwater, FL 33755 Toll Free: 1-866-289-6611 Batteries: 4 x AA 1.5V AC Adapter 6V DC 600mA FCC ID: U7I-BP3KV1-5W-2 Monitoring Device Assembled In Vietnam; Cuff Made In China IP20 Lot No.: YYMMDDXXXXXV Blood Pressure Monitor Model: BP3KV1-5W Distributed by: Microlife USA, Inc. Clearwater, FL 33755 Toll Free: 1-866-289-6611 Batteries: 4 x AA 1.5V AC Adapter 6V DC 600mA FCC ID: U7I-BP3KV1-5W-2 Monitoring Device Assembled In Vietnam; Cuff Made In China IP20 Lot No.: YYMMDDXXXXXV
ReportNo.:EED32R82156402Page1of7 RFExposureEvaluationReport Product:BloodPressureMonitor Trademark:N/A Model/Typereference:BP3KV1-5W SerialNumber:N/A ReportNumber:EED32R82156402 FCCID:U7I-BP3KV1-5W-2 DateofIssue:Dec.26,2025 TestStandards: 47CFRPart1.1307 47CFRPart1.1310 47CFRPart2.1093 KDB447498D04InterimGeneralRF ExposureGuidancev01 Testresult:PASS Preparedfor: MicrolifeCorporation 9F,No.431,RuiGuangRoad,NeiHu,Taipei,114,Taiwan,China Preparedby: CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialPark,Zone70,Bao’anDistrict, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: LucasLuKevenTan Approvedby:Date:Dec.26,2025 AaronMa CheckNo.:5006111125 ReportNo.:EED32R82156402Page2of7 1Contents Page 1CONTENTS........................................................................................................................................................................2 2GENERALINFORMATION..............................................................................................................................................3 2.1CLIENTINFORMATION...................................................................................................................................................3 2.2GENERALDESCRIPTIONOFEUT...................................................................................................................................3 2.3PRODUCTSPECIFICATIONSUBJECTIVETOTHISSTANDARD...........................................................................................3 2.4TESTLOCATION.............................................................................................................................................................4 2.5DEVIATIONFROMSTANDARDS......................................................................................................................................4 2.6ABNORMALITIESFROMSTANDARDCONDITIONS..........................................................................................................4 2.7OTHERINFORMATIONREQUESTEDBYTHECUSTOMER................................................................................................4 3SAREVALUATION...........................................................................................................................................................5 3.1RFEXPOSURECOMPLIANCEREQUIREMENT.................................................................................................................5 3.1.1Limits....................................................................................................................................................................5 3.1.2TestProcedure....................................................................................................................................................5 3.1.3EUTRFExposureEvaluation..........................................................................................................................6 ReportNo.:EED32R82156402Page3of7 2GeneralInformation 2.1ClientInformation Applicant: MicrolifeCorporation AddressofApplicant: 9F,No.431,RuiGuangRoad,NeiHu,Taipei,114,Taiwan,China Manufacturer: ONFUElectronicsCompanyLimited AddressofManufacturer: StreetNo,3SongMayIndustrialZone,BacSonCommune,TrangBom District,DongNaiProvince,76000,Vietnam Factory: ONFUElectronicsCompanyLimited AddressofFactory: StreetNo,3SongMayIndustrialZone,BacSonCommune,TrangBom District,DongNaiProvince,76000,Vietnam 2.2GeneralDescriptionofEUT ProductName: BloodPressureMonitor ModelNo.(EUT): BP3KV1-5W TradeMark: N/A 2.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHz~2480MHz ModulationType:GFSK TestPowerGrade:Default TestSoftwareofEUT:nRFgoStudio AntennaType: ChipAntenna AntennaGain: 1.08dBi PowerSupply: Adapter: Model:DSA-4PFG-060060 Input:100-240V,50/60Hz,0.3A Ouptut:6V,600mA Battery:RatedVoltage:6V SampleReceivedDate: Nov.12,2025 SampletestedDate: Nov.12,2025toDec.05,2025 ReportNo.:EED32R82156402Page4of7 2.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd HongweiIndustrialPark,Zone70,Bao'anDistrict,Shenzhen,Guangdong,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164,TestFirmRegistrationNo.:260439 2.5DeviationfromStandards None. 2.6AbnormalitiesfromStandardConditions None. 2.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32R82156402Page5of7 3SAREvaluation 3.1RFExposureComplianceRequirement 3.1.1Limits TheSAR-basedexemptionformulaof§1.1307(b)(3)(i)(B),repeatedhereasFormula(B.2),appliesfor singlefixed,mobile,andportableRFsourceswithavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,oflessthanorequaltothethresholdPth(mW). Thismethodshallonlybeusedatseparationdistancesfrom0.5cmto40cmandatfrequenciesfrom 0.3GHzto6GHz(inclusive).PthisgivenbyFormula andfisinGHz,distheseparationdistance(cm),andERP20cmisperFormula(B.1). The1mWBlanketExemptionof§1.1307(b)(3)(i)(A)appliesforsinglefixed,mobile,andportableRF sourceswithavailablemaximumtime-averagedpowerofnomorethan1mW,regardlessofseparation distance. 3.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportNo.:EED32R82156402Page6of7 3.1.3EUTRFExposureEvaluation ForStandalone: Band Freq. (MHz) Estimation distance (cm) Max. Conducted Output power (dBm) Antenna Gain (dBi) ERP (dBm) ERP (mW) Limit (mW) MPE ratio Result BLE24020.5-4.281.08-5.350.292.7880.1047Pass Note: ①EIRP=conductedpower+antennagain; ②ERP=EIRP-2.15; ③EIRP(dBm)=Fieldstrengthofthefundamentalsignal(dBuV/m@3m)–95.23; ④ERP(mW)=10^ (ERP(dBm)/10); ⑤Theestimationdistanceis0.5cm; ⑥ThetestdatapleaserefertothereportofEED32R82156401andonlytheworstcasedatawasrecorded inthereport. ReportNo.:EED32R82156402Page7of7 Statement 1.Thisreportisconsideredinvalidwithoutapprovedsignature,specialsealandthesealontheperforation; 2.TheCompanyNameshownonReportandAddress,thesample(s)andsam…
Text truncated - open the document above for the full version.
2. 4 Ap W Fea S Pa AN (1)S (2) (3) (4) (5)C El e Wo Pea Imp VSW Pol Azi Ope The Dim 4GHz 32 pplication WLAN, 802 atures SMD, high rt numbe T 3216 (1) Size Code Packing Frequency Packing N Code ectrical S orking Freq ak Gain pedance WR arization muth Beam eration Te specification i mension 216 Chi n: 2.11b/g, Blu reliability, er R 240 (2) (3 y Number Specifica quencyRan mwidth mperature s defined on H and Ter p Anten uetooth, et ultra comp 00 3K L ) (4) ( 3.2x1.6m Tape and 2.4GHz 3K L0 ation nge (°C) HEK EVB. minal Co nna: AN tc... pact, Omni- L0 5) mm d reel 2400 1.08 5 2 Omn -4 onfigurat W T D D NT3216R -directiona ~2484 MH 8dBi (Typ.) 50 Ohm .5(Max) Linear i-directiona 40~85°C tion Dimensio L 3.2 W 1.6 T 0.6 D1 0.5 D2 1.3 R24003K al... Hz ) al on (mm) 0+-0.15 0+-0.15 0+-0.10 0+-0.15 0+-0.15 KL0 No. 1 2 Term F G minal Name Feeding Ground 1 / 5 e 2.4GHz 3216 Chip Antenna: ANT3216R24003KL0 2 / 5 Evaluation Board Reference PCB Dimension Antenna Layout Reference Unit : mm 2.4GHz 3216 Chip Antenna: ANT3216R24003KL0 3 / 5 Electrical Characteristics VSWR Radiation Pattern X Y Z 2.4GHz 3216 Chip Antenna: ANT3216R24003KL0 4 / 5 Taping Specifications Reel and Taping Specification Reel Specification TYPE SIZE A ψB ψC ψD W ψM 3216 7” 3K/Reel 2.0±0.5 13.5±1.0 21±1.0 60±1.0 11.5±2.0 178±2.0 Taping Specification Packaging Type A B W E F G H T ψD P Paper Type 3216 1.90±0.20 3.50±0.20 8.0±0.20 1.75±0.10 3.5±0.05 4.0±0.10 2.0±0.05 0.75±0.10 +0.10 1.50 -0 4.0±0.1 2.4GHz 3216 Chip Antenna: ANT3216R24003KL0 5 / 5 Recommended Reflow Profile Pb free solder Soaking Working Soldering Peak Temp. Time Temp. Time Temp. Time Temp. T1 T2 t1 T3 t2 T4 t3 T5 150°C 180°C 60 to 120sec 230°C more than 30sec 247 to 253°C within 10sec 260°C Max. AUG. 2022 Ver.H01
ReportNo.:EED32R82156401Page1of24 Appendix:BluetoothLE ReportNo.:EED32R82156401Page2of24 Contents DutyCycle..................................................................................................................................................................................................3 MaximumPeakConductedOutputPower..................................................................................................................................................6 -6dBBandwidth..........................................................................................................................................................................................9 OccupiedChannelBandwidth..................................................................................................................................................................12 MaximumPowerSpectralDensityLevel..................................................................................................................................................15 BandEdge................................................................................................................................................................................................18 ConductedRFSpuriousEmission............................................................................................................................................................21 ReportNo.:EED32R82156401Page3of24 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTBLE1M2402Ant168.641.632.33 NVNTBLE1M2440Ant169.281.592.31 NVNTBLE1M2480Ant169.281.592.31 ReportNo.:EED32R82156401Page4of24 TestGraphs DutyCycleNVNTBLE1M2402MHzAnt1 DutyCycleNVNTBLE1M2440MHzAnt1 ReportNo.:EED32R82156401Page5of24 DutyCycleNVNTBLE1M2480MHzAnt1 ReportNo.:EED32R82156401Page6of24 MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) Limit (dBm) Verdict NVNTBLE1M2402Ant1-4.2830Pass NVNTBLE1M2440Ant1-5.7430Pass NVNTBLE1M2480Ant1-6.4330Pass ReportNo.:EED32R82156401Page7of24 TestGraphs PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 ReportNo.:EED32R82156401Page8of24 PeakPowerNVNTBLE1M2480MHzAnt1 ReportNo.:EED32R82156401Page9of24 -6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.7050.5Pass NVNTBLE1M2440Ant10.6980.5Pass NVNTBLE1M2480Ant10.7010.5Pass ReportNo.:EED32R82156401Page10of24 TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 ReportNo.:EED32R82156401Page11of24 -6dBBandwidthNVNTBLE1M2480MHzAnt1 ReportNo.:EED32R82156401Page12of24 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.041 NVNTBLE1M2440Ant11.046 NVNTBLE1M2480Ant11.046 ReportNo.:EED32R82156401Page13of24 TestGraphs OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2440MHzAnt1 ReportNo.:EED32R82156401Page14of24 OBWNVNTBLE1M2480MHzAnt1 ReportNo.:EED32R82156401Page15of24 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE1M2402Ant1-18.488Pass NVNTBLE1M2440Ant1-18.868Pass NVNTBLE1M2480Ant1-19.518Pass ReportNo.:EED32R82156401Page16of24 TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 ReportNo.:EED32R82156401Page17of24 PSDNVNTBLE1M2480MHzAnt1 ReportNo.:EED32R82156401Page18of24 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-38.95-20Pass NVNTBLE1M2480Ant1-49.35-20Pass ReportNo.:EED32R82156401Page19of24 TestGraphs BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32R82156401Page20of24 BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32R82156401Page21of24 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-44.77-20Pass NVNTBLE1M2440Ant1-43.83-20Pass NVNTBLE1M2480Ant1-39.95-20Pass ReportNo.:EED32R82156401Page22of24 TestGraphs Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32R82156401Page23of24 Tx.SpuriousNVNTBLE1M2440MHzAnt1Ref Tx.SpuriousNVNTBLE1M2440MHzAnt1Emission ReportNo.:EED32R82156401Page24of24 Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ***EndofReport***
ReportNo.:EED32R82156401Page 1 of 38 TESTREPORT Product:BloodPressureMonitor Trademark:N/A Model/Typereference:BP3KV1-5W SerialNumber:N/A ReportNumber:EED32R82156401 FCCID:U7I-BP3KV1-5W-2 DateofIssue:Dec.26,2025 TestStandards:47CFRPart15SubpartC Testresult:PASS Preparedfor: MicrolifeCorporation 9F,No.431,RuiGuangRoad,NeiHu,Taipei,114,Taiwan,China Preparedby: CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialPark,Zone70,Bao’anDistrict, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: LucasLuKevenTan Approvedby:Date:Dec.26,2025 AaronMa CheckNo.:5006111125 ReportNo.:EED32R82156401Page 2 of 38 1Content 1CONTENT............................................................................................................................................................................2 2TESTSUMMARY...............................................................................................................................................................3 3GENERALINFORMATION...............................................................................................................................................4 3.1CLIENTINFORMATION....................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT.................................................................................................................................4 3.3TESTCONFIGURATION..................................................................................................................................................5 3.4TESTENVIRONMENT.....................................................................................................................................................6 3.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................6 3.6TESTLOCATION.............................................................................................................................................................6 3.7MEASUREMENTUNCERTAINTY(95%CONFIDENCELEVELS,K=2).............................................................................7 4EQUIPMENTLIST..............................................................................................................................................................8 5TESTRESULTSANDMEASUREMENTDATA.........................................................................................................12 5.1ANTENNAREQUIREMENT............................................................................................................................................12 5.2CONDUCTEDEMISSIONS.............................................................................................................................................13 5.3MAXIMUMCONDUCTEDOUTPUTPOWER..................................................................................................................17 5.4DTSBANDWIDTH........................................................................................................................................................18 5.5MAXIMUMPOWERSPECTRALDENSITY.....................................................................................................................19 5.6BANDEDGEMEASUREMENTSANDCONDUCTEDSPURIOUSEMISSION...................................................................20 5.7RADIATEDSPURIOUSEMISSION&RESTRICTEDBANDS...........................................................................................21 6APPENDIXA.....................................................................................................................................................................36 7PHOTOGRAPHS..............................................................................................................................................................37 ReportNo.:EED32R82156401Page 3 of 38 2TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 PASS DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpuriousEmissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS ReportNo.:EED32R82156401Page 4 of 38 3GeneralInformation 3.1ClientInformation Applicant:MicrolifeCorporation AddressofApplicant:9F,No.431,RuiGuangRoad,NeiHu,Taipei,114,Taiwan,China Manufacturer:ONFUElectronicsCompanyLimited AddressofManufacturer:StreetNo,3SongMayIndustrialZone,BacSonCommune,TrangBom District,DongNaiProvince,76000,Vietnam Factory:ONFUElectronicsCompanyLimited AddressofFactory:StreetNo,3SongMayIndustrialZone,BacSonCommune,TrangBom District,DongNaiProvince,76000,Vietnam 3.2GeneralDescriptionofEUT ProductName: BloodPressureMonitor ModelNo.: BP3KV1-5W TestModelNo.: BP3KV1-5W Trademark: N/A ProductType: MobilePortableFixLocation OperationFrequency: 2402MHz~2480MHz ModulationType: GFSK TransferRate:1Mbps NumberofChannel: 40 AntennaType:ChipAntenna AntennaGain:1.08dBi PowerSupply: Adapter: Model:DSA-4PFG-060060 Input:100-240V,50/60Hz,0.3A Ouptut:6V,600mA Battery:RatedVoltage:6V TestVoltage:DC6V SampleReceivedDate:Nov.12,2025 SampletestedDate:Nov.12,2025toDec.05,2025 ReportNo.:EED32R82156401Page 5 of 38 OperationFrequencyeachofchannel Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 02402102422202442302462 12404112424212444312464 22406122426222446322466 32408132428232448332468 42410142430242450342470 52412152432252452352472 62414162434262454362474 72416172436272456372476 8…
Text truncated - open the document above for the full version.
1617 Gulf to Bay Blvd. 2nd Floor · Clearwater, Florida, 33755 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 400.00 µW |
Digital Non-invasive Blood Pressure and Electrocardiogram Monitor
Equipment Class
DTS - Digital Transmission System
Digital Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Peak flow meter
Equipment Class
DTS - Digital Transmission System
Digital Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System
Digital Blood Pressure Monitor
Equipment Class
DTS - Digital Transmission System