FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Microlife Corporation/
  3. U7I-EBPHKW2-D

U7I-EBPHKW2-DDigital Non-invasive Blood Pressure and Electrocardiogram Monitor

Microlife Corporation

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 03, 2026
Application Purpose
Original Equipment
Equipment Note
Digital Non-invasive Blood Pressure and Electrocardiogram Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Microlife Corporation
Country
Taiwan

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 2/17/2023 Microlife Corporation Fe deral Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Da te: June 4, 2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: U7I-EBPHKW2-D Mic rolife Corporation(“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Microlife Corporation (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sin cerely, Sig nature: Pr inted name: Jimmy Deng 2026.06.04

Attestation Statements

Rev 2/17/2023 Microlife Corporation F ederal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: June 4, 2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: U7I-EBPHKW2-D Microlife Corporation (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Signature: Printed name: Jimmy Deng 2026.06.04

Attestation Statements

Rev 1/26/2023 Microlife Corporation Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: June 11, 2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID : U7I-EBPHKW2-D Applicant FRN: 0016306045 Microlife Corporation (“the applicant”) certifies that, as of the date of the filing of the application, Microlife USA Inc is our designated U.S. agent for service of process for the above referenced FCC ID. Microlife Corporation accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Microlife USA Inc accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Microlife USA Inc. FRN: 0033599390 Address: 1617 Gulf to Bay Blvd., 2 nd Floor Clearwater, FL 33755 Contact Person: Jason Frieders Email: [email protected] Sincerely, Microlife Corporation Microlife USA Inc. printed name: Jimmy Deng printed name: Jason Frieders Signature: Signature: 2026.06.11 June 12, 2026

Cover Letter(s)

Rev 11/20/07 Microlife Corporation Federal Communications Commission Authorization and Evaluation Division Conf identiality Request regarding application for certification of FCC ID: U7I-EBPHKW2-D Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name (Block Diagram, Schematics, Operational Description) (Block Diagram.pdf, Schematics.pdf, Operational Description.pdf) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request that the information attached to this application be temporarily confidential for 180 days as outlined below: Exhibit Type File Name User Manual.pdf External Photos.pdf Internal Photos.pdf Test Setup Photos.pdf User Manual.pdf External Photos.pdf Internal Photos.pdf Test Setup Photos.pdf Sincerely, Signature: printed name: Jimmy Deng Dat e: June 4, 2026 2026.06.04

Cover Letter(s)

Microlife Corporation F ederal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: June 4, 2026 SUBJECT: FCC Application for (FCC ID: U7I-EBPHKW2-D ) To Whom It May Concern: We, the undersigned, hereby authorize Aimee Ai at Centre Testing International Group Co., Ltd / Hongwei Industrial Park, Zone 70, Bao’an District, Shenzhen, Guangdong, China on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Aimee Ai at Centre Testing International Group Co., Ltd / Hongwei Industrial Park, Zone 70, Bao’an District, Shenzhen, Guangdong, China on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section R egards, Signature: pr inted name: Jimmy Deng 2026.06.04

RF Exposure Info

ReportNo.:EED32S80882702Page1of7 RFExposureEvaluationReport Product:DigitalNon-invasiveBloodPressure andElectrocardiogramMonitor Trademark:N/A Model/Typereference:EBPHKW2-D SerialNumber:N/A ReportNumber:EED32S80882702 FCCID:U7I-EBPHKW2-D DateofIssue:Jun.09,2026 TestStandards: 47CFRPart1.1307 47CFRPart1.1310 47CFRPart2.1093 KDB447498D04InterimGeneralRF ExposureGuidancev01 Testresult:PASS Preparedfor: MicrolifeCorporation 9F,No.431,RuiGuangRoad,NeiHu,Taipei,114,Taiwan,China Preparedby: CentreTestingInternationalGroupCo.,Ltd. BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict, Shenzhen,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: WinWeiKevenTan Approvedby:Date:Jun.09,2026 AaronMa CheckNo.:6022220426 ReportNo.:EED32S80882702Page2of7 1Contents Page 1CONTENTS........................................................................................................................................................................2 2GENERALINFORMATION..............................................................................................................................................3 2.1CLIENTINFORMATION...................................................................................................................................................3 2.2GENERALDESCRIPTIONOFEUT...................................................................................................................................3 2.3PRODUCTSPECIFICATIONSUBJECTIVETOTHISSTANDARD...........................................................................................3 2.4TESTLOCATION.............................................................................................................................................................4 2.5DEVIATIONFROMSTANDARDS......................................................................................................................................4 2.6ABNORMALITIESFROMSTANDARDCONDITIONS..........................................................................................................4 2.7OTHERINFORMATIONREQUESTEDBYTHECUSTOMER................................................................................................4 3SAREVALUATION...........................................................................................................................................................5 3.1RFEXPOSURECOMPLIANCEREQUIREMENT.................................................................................................................5 3.1.1Limits....................................................................................................................................................................5 3.1.2TestProcedure....................................................................................................................................................5 3.1.3EUTRFExposureEvaluation..........................................................................................................................6 ReportNo.:EED32S80882702Page3of7 2GeneralInformation 2.1ClientInformation Applicant: MicrolifeCorporation AddressofApplicant: 9F,No.431,RuiGuangRoad,NeiHu,Taipei,114,Taiwan,China Manufacturer: ONBOElectronic(Shenzhen)Co.,Ltd AddressofManufacturer: No.138,HuashengRoad,LangkouCommunity,DalangStreet,LonghuaDistrict, Shenzhen,China Factory: ONBOElectronic(Shenzhen)Co.,Ltd AddressofFactory: No.138,HuashengRoad,LangkouCommunity,DalangStreet,LonghuaDistrict, Shenzhen,China 2.2GeneralDescriptionofEUT ProductName: DigitalNon-invasiveBloodPressureandElectrocardiogramMonitor ModelNo.: EBPHKW2-D TestModelNo.: EBPHKW2-D TradeMark: N/A 2.3ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHz~2480MHz ModulationType:GFSK TestPowerGrade:Default TestSoftwareofEUT:nRFConnect AntennaType: Chipantenna AntennaGain: 3.0dBi PowerSupply: Battery:DC1.5V*4(AA) SampleReceivedDate: Apr.24,2026 SampletestedDate: Apr.24,2026toMay26,2026 ReportNo.:EED32S80882702Page4of7 2.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164,TestFirmRegistrationNo.:260439 2.5DeviationfromStandards None. 2.6AbnormalitiesfromStandardConditions None. 2.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32S80882702Page5of7 3SAREvaluation 3.1RFExposureComplianceRequirement 3.1.1Limits TheSAR-basedexemptionformulaof§1.1307(b)(3)(i)(B),repeatedhereasFormula(B.2),appliesfor singlefixed,mobile,andportableRFsourceswithavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,oflessthanorequaltothethresholdPth(mW). Thismethodshallonlybeusedatseparationdistancesfrom0.5cmto40cmandatfrequenciesfrom 0.3GHzto6GHz(inclusive).PthisgivenbyFormula andfisinGHz,distheseparationdistance(cm),andERP20cmisperFormula(B.1). The1mWBlanketExemptionof§1.1307(b)(3)(i)(A)appliesforsinglefixed,mobile,andportableRF sourceswithavailablemaximumtime-averagedpowerofnomorethan1mW,regardlessofseparation distance. 3.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportNo.:EED32S80882702Page6of7 3.1.3EUTRFExposureEvaluation ForStandalone: Band Freq. (MHz) Estimation distance (cm) Max. Conducted Output power (dBm) Antenna Gain (dBi) ERP (dBm) ERP (mW) Limit (mW) MPE ratio Result BLE24800.5-0.473.00.381.092.7170.4017Pass Note: ①EIRP=conductedpower+antennagain; ②ERP=EIRP-2.15; ③EIRP(dBm)=Fieldstrengthofthefundamentalsignal(dBuV/m@3m)–95.23; ④ERP(mW)=10^(ERP(dBm)/10); ⑤Theestimationdistanceis0.5cm; ⑥ThetestdatapleaserefertothereportofEED32S80882701andonlytheworstcasedatawasrecorded inthereport. ReportNo.:EED32S80882702Page7of7 Statement 1.Thisreportisconsideredinvalidwithoutapprovedsignature,specialsealandthesealontheperforation; 2.TheCompanyNameshownonReportandAddress,thesample(s)andsampleinforma…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32S80882701Page1of34 Appendix:BluetoothLE ReportNo.:EED32S80882701Page2of34 Contents DutyCycle..................................................................................................................................................................................................3 MaximumPeakConductedOutputPower..................................................................................................................................................7 -6dBBandwidth........................................................................................................................................................................................11 OccupiedChannelBandwidth..................................................................................................................................................................15 MaximumPowerSpectralDensityLevel..................................................................................................................................................19 BandEdge................................................................................................................................................................................................23 ConductedRFSpuriousEmission............................................................................................................................................................28 ReportNo.:EED32S80882701Page3of34 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTBLE1M2402Ant163.361.982.53 NVNTBLE1M2440Ant163.0422.54 NVNTBLE1M2480Ant162.882.012.54 NVNTBLE2M2402Ant133.444.764.78 NVNTBLE2M2440Ant133.64.744.76 NVNTBLE2M2480Ant133.64.744.76 ReportNo.:EED32S80882701Page4of34 TestGraphs DutyCycleNVNTBLE1M2402MHzAnt1 DutyCycleNVNTBLE1M2440MHzAnt1 ReportNo.:EED32S80882701Page5of34 DutyCycleNVNTBLE1M2480MHzAnt1 DutyCycleNVNTBLE2M2402MHzAnt1 ReportNo.:EED32S80882701Page6of34 DutyCycleNVNTBLE2M2440MHzAnt1 DutyCycleNVNTBLE2M2480MHzAnt1 ReportNo.:EED32S80882701Page7of34 MaximumPeakConductedOutputPower ConditionModeFrequency (MHz) AntennaConductedPower (dBm) Limit (dBm) Verdict NVNTBLE1M2402Ant1-0.2130Pass NVNTBLE1M2440Ant1-0.5130Pass NVNTBLE1M2480Ant1-1.130Pass NVNTBLE2M2402Ant1-0.1930Pass NVNTBLE2M2440Ant1-0.4730Pass NVNTBLE2M2480Ant1-1.0830Pass ReportNo.:EED32S80882701Page8of34 TestGraphs PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 ReportNo.:EED32S80882701Page9of34 PeakPowerNVNTBLE1M2480MHzAnt1 PeakPowerNVNTBLE2M2402MHzAnt1 ReportNo.:EED32S80882701Page10of34 PeakPowerNVNTBLE2M2440MHzAnt1 PeakPowerNVNTBLE2M2480MHzAnt1 ReportNo.:EED32S80882701Page11of34 -6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.6920.5Pass NVNTBLE1M2440Ant10.7040.5Pass NVNTBLE1M2480Ant10.6950.5Pass NVNTBLE2M2402Ant11.1380.5Pass NVNTBLE2M2440Ant11.140.5Pass NVNTBLE2M2480Ant11.1410.5Pass ReportNo.:EED32S80882701Page12of34 TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 ReportNo.:EED32S80882701Page13of34 -6dBBandwidthNVNTBLE1M2480MHzAnt1 -6dBBandwidthNVNTBLE2M2402MHzAnt1 ReportNo.:EED32S80882701Page14of34 -6dBBandwidthNVNTBLE2M2440MHzAnt1 -6dBBandwidthNVNTBLE2M2480MHzAnt1 ReportNo.:EED32S80882701Page15of34 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.042 NVNTBLE1M2440Ant11.045 NVNTBLE1M2480Ant11.047 NVNTBLE2M2402Ant12.058 NVNTBLE2M2440Ant12.059 NVNTBLE2M2480Ant12.063 ReportNo.:EED32S80882701Page16of34 TestGraphs OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2440MHzAnt1 ReportNo.:EED32S80882701Page17of34 OBWNVNTBLE1M2480MHzAnt1 OBWNVNTBLE2M2402MHzAnt1 ReportNo.:EED32S80882701Page18of34 OBWNVNTBLE2M2440MHzAnt1 OBWNVNTBLE2M2480MHzAnt1 ReportNo.:EED32S80882701Page19of34 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNTBLE1M2402Ant1-15.478Pass NVNTBLE1M2440Ant1-15.78Pass NVNTBLE1M2480Ant1-16.328Pass NVNTBLE2M2402Ant1-18.028Pass NVNTBLE2M2440Ant1-18.328Pass NVNTBLE2M2480Ant1-18.978Pass ReportNo.:EED32S80882701Page20of34 TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 ReportNo.:EED32S80882701Page21of34 PSDNVNTBLE1M2480MHzAnt1 PSDNVNTBLE2M2402MHzAnt1 ReportNo.:EED32S80882701Page22of34 PSDNVNTBLE2M2440MHzAnt1 PSDNVNTBLE2M2480MHzAnt1 ReportNo.:EED32S80882701Page23of34 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-46.19-20Pass NVNTBLE1M2480Ant1-50.22-20Pass NVNTBLE2M2402Ant1-36.01-20Pass NVNTBLE2M2480Ant1-51.49-20Pass ReportNo.:EED32S80882701Page24of34 TestGraphs BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32S80882701Page25of34 BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32S80882701Page26of34 BandEdgeNVNTBLE2M2402MHzAnt1Ref BandEdgeNVNTBLE2M2402MHzAnt1Emission ReportNo.:EED32S80882701Page27of34 BandEdgeNVNTBLE2M2480MHzAnt1Ref BandEdgeNVNTBLE2M2480MHzAnt1Emission ReportNo.:EED32S80882701Page28of34 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-46.1-20Pass NVNTBLE1M2440Ant1-47.66-20Pass NVNTBLE1M2480Ant1-46.28-20Pass NVNTBLE2M2402Ant1-46.18-20Pass NVNTBLE2M2440Ant1-46.63-20Pass NVNTBLE2M2480Ant1-49.5-20Pass ReportNo.:EED32S80882701Page29of34 TestGraphs Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32S80882701Page30of34 Tx.SpuriousNVNTBLE1M2440MHzAnt1Ref Tx.SpuriousNVNTBLE1M2440MHzAnt1Emission ReportNo.:EED32S80882701Page31of34 Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32S80882701Page32of34 Tx.SpuriousNVNTBLE2M2402MHzAnt1Ref Tx.SpuriousNVNTBLE2M2402MHzAnt1Emission ReportNo.:EED32S80882701Page33of34 Tx.SpuriousNVNTBLE2M2440MHzAnt1Ref Tx.SpuriousNVNTBLE2M2440MHzAnt1Emission ReportNo.:EED32S80882701Page34of34 Tx.SpuriousNVNTBLE2M2480MHzAnt1Ref Tx.SpuriousNVNTBLE2M2480MHzAnt1E…

Text truncated - open the document above for the full version.

Test Report

Report No. : EED32S80882701Page 1 of 55 TEST REPORT Product:Digital Non-invasive Blood Pressure and Electrocardiogram Monitor Trade mark:N/A Model/Type reference :EBPHKW2-D Serial Number:N/A Report Number:EED32S80882701 FCC ID:U7I-EBPHKW2-D Date of Issue:Jun. 09, 2026 Test Standards:47 CFR Part 15 Subpart C Test result:PASS Prepared for: Microlife Corporation 9F, No.431, RuiGuang Road, NeiHu, Taipei, 114, Taiwan, China Prepared by: Centre Testing International Group Co., Ltd. Building C, Hongwei Industrial Park Block 70, Bao'an District, Shenzhen, China TEL: +86-755-3368 3668 FAX: +86-755-3368 3385 Compiled by:Reviewed by: Win WeiKeven Tan Approved by:Date:Jun. 09, 2026 Aaron Ma Check No.:6022220426 Report No. : EED32S80882701Page 2 of 55 1 Content 1 CONTENT............................................................................................................................................................................2 2 TEST SUMMARY............................................................................................................................................................... 3 3 GENERAL INFORMATION...............................................................................................................................................4 3.1 CLIENTINFORMATION....................................................................................................................................................4 3.2 GENERALDESCRIPTION OFEUT.................................................................................................................................4 3.3 TESTCONFIGURATION..................................................................................................................................................5 3.4 TESTENVIRONMENT.....................................................................................................................................................6 3.5 DESCRIPTION OFSUPPORTUNITS...............................................................................................................................6 3.6 TESTLOCATION.............................................................................................................................................................6 3.7 MEASUREMENTUNCERTAINTY(95%CONFIDENCE LEVELS,K=2).............................................................................7 4 EQUIPMENT LIST..............................................................................................................................................................8 5 TEST RESULTS AND MEASUREMENT DATA.........................................................................................................11 5.1 ANTENNAREQUIREMENT............................................................................................................................................11 5.2 MAXIMUMCONDUCTEDOUTPUTPOWER.................................................................................................................. 12 5.3 DTS BANDWIDTH........................................................................................................................................................13 5.4 MAXIMUMPOWERSPECTRALDENSITY.....................................................................................................................14 5.5 BANDEDGE MEASUREMENTS ANDCONDUCTEDSPURIOUSEMISSION...................................................................15 5.6 RADIATEDSPURIOUSEMISSION& RESTRICTED BANDS...........................................................................................16 6 APPENDIX A.....................................................................................................................................................................53 7 PHOTOGRAPHS..............................................................................................................................................................54 Report No. : EED32S80882701Page 3 of 55 2 Test Summary Test ItemTest RequirementResult Antenna Requirement 47 CFR Part 15 Subpart C Section 15.203/15.247 (c) PASS AC Power Line Conducted Emission 47 CFR Part 15 Subpart C Section 15.207 N/A DTS Bandwidth 47 CFR Part 15 Subpart C Section 15.247 (a)(2) PASS Maximum Conducted Output Power 47 CFR Part 15 Subpart C Section 15.247 (b)(3) PASS Maximum Power Spectral Density 47 CFR Part 15 Subpart C Section 15.247 (e)PASS Band Edge Measurements 47 CFR Part 15 Subpart C Section 15.247(d) PASS Conducted Spurious Emissions 47 CFR Part 15 Subpart C Section 15.247(d) PASS Radiated Spurious Emission & Restricted bands 47 CFR Part 15 Subpart C Section 15.205/15.209 PASS Report No. : EED32S80882701Page 4 of 55 3 General Information 3.1 Client Information Applicant:Microlife Corporation Address of Applicant:9F, No.431, RuiGuang Road, NeiHu, Taipei, 114, Taiwan, China Manufacturer:ONBO Electronic (Shenzhen) Co., Ltd Address of Manufacturer: No.138, Huasheng Road, Langkou Community, Dalang Street, Longhua District, Shenzhen, China Factory:ONBO Electronic (Shenzhen) Co., Ltd Address of Factory:No.138, Huasheng Road, Langkou Community, Dalang Street, Longhua District, Shenzhen, China 3.2 General Description of EUT Product Name: Digital Non-invasive Blood Pressure and Electrocardiogram Monitor Model No.: EBPHKW2-D Test Model No.: EBPHKW2-D Trade mark: N/A Product Type: MobilePortableFix Location Operation Frequency: 2402MHz~2480MHz Modulation Type: GFSK Transfer Rate:1Mbps, 2Mbps Number of Channel: 40 Antenna Type:Chip antenna Antenna Gain:3.0dBi Power Supply:Battery:DC1.5V*4(AA) Test Voltage:DC 6.0V Sample Received Date: Apr. 24, 2026 Sample tested Date:Apr. 24, 2026 to May 26, 2026 Report No. : EED32S80882701Page 5 of 55 Operation Frequency each of channel Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 02402102422202442302462 12404112424212444312464 22406122426222446322466 32408132428232448332468…

Text truncated - open the document above for the full version.

Test Report

Report No. : EED32S80882701Page 43 of 55 Test_Mode BLE 2M GFSK Transmitting Test_Frequency2480MHz Ant/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 1 18949.6 58 -26.2862.3936.1174.0037.89PASSHorizontalPK 2 19965.2 786 -24.7361.7737.0474.0036.96PASSHorizontalPK 3 21241.3 497 -25.7862.4636.6874.0037.32PASSHorizontalPK 4 22245.0 698 -25.3360.2234.8974.0039.11PASSHorizontalPK 5 23097.4 839 -24.9960.4135.4274.0038.58PASSHorizontalPK 6 24323.9 13 -22.0458.1936.1574.0037.85PASSHorizontalPK Report No. : EED32S80882701Page 44 of 55 Test_Mode BLE 2M GFSK Transmitting Test_Frequency2480MHz Ant/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 1 18770.8 108 -26.3563.1236.7774.0037.23PASSVerticalPK 2 19822.1 329 -25.1761.5736.4074.0037.60PASSVerticalPK 3 21140.3 656 -25.8261.1935.3774.0038.63PASSVerticalPK 4 22113.4 845 -25.5860.9135.3374.0038.67PASSVerticalPK 5 23316.4 527 -23.8559.6235.7774.0038.23PASSVerticalPK 6 24850.2 54 -22.0157.9335.9274.0038.08PASSVerticalPK Remark: 1) The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic equation with a sample calculation is as follows: Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor 2) Scan from 9kHz to 25GHz, the disturbance above 10GHz and below 30MHz was very low. As shown in this section, for frequencies above 1GHz, the field strength limits are based on average limits. However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation.The report records the lowest Peak value. If the Peak value is greater than 54dBμV/m, then the Average value at that time is recorded. Report No. : EED32S80882701Page 45 of 55 Restricted bands: Test plot as follows: Test_Mode BLE 1M GFSK Transmitting Test_Frequency2402MHz Remark:/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 1239015.9635.7251.6874.0022.32PASS Horizont al PK 2239015.9628.2644.2254.009.78PASS Horizont al AV Report No. : EED32S80882701Page 46 of 55 Test_Mode BLE 1M GFSK Transmitting Test_Frequency2402MHz Remark:/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 1239015.9635.6351.5974.0022.41PASSVerticalPK 2239015.9628.8444.8054.009.20PASSVerticalAV Report No. : EED32S80882701Page 47 of 55 Test_Mode BLE 1M GFSK Transmitting Test_Frequency2480MHz Remark:/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 12483.516.2932.7849.0774.0024.93PASS Horizont al PK 22483.516.2924.9441.2354.0012.77PASS Horizont al AV Report No. : EED32S80882701Page 48 of 55 Test_Mode BLE 1M GFSK Transmitting Test_Frequency2480MHz Remark:/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 12483.516.2932.2148.5074.0025.50PASSVerticalPK 22483.516.2924.8241.1154.0012.89PASSVerticalAV Report No. : EED32S80882701Page 49 of 55 Test_Mode BLE 2M GFSK Transmitting Test_Frequency2402MHz Remark:/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 1239015.9636.7552.7174.0021.29PASS Horizont al PK 2239015.9628.1444.1054.009.90PASS Horizont al AV Report No. : EED32S80882701Page 50 of 55 Test_Mode BLE 2M GFSK Transmitting Test_Frequency2402MHz Remark:/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 1239015.9635.9951.9574.0022.05PASSVerticalPK 2239015.9627.4843.4454.0010.56PASSVerticalAV Report No. : EED32S80882701Page 51 of 55 Test_Mode BLE 2M GFSK Transmitting Test_Frequency2402MHz Remark:/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 12483.516.2931.7748.0674.0025.94PASS Horizont al PK 22483.516.2924.3040.5954.0013.41PASS Horizont al AV Report No. : EED32S80882701Page 52 of 55 Test_Mode BLE 2M GFSK Transmitting Test_Frequency2402MHz Remark:/Test_Date2026/5/23 Test Graph Suspected List NO Freq. [MHz] Factor [dB] Reading [dBμV] Level [dBμV/m] Limit [dBμV/m] Margin [dB] ResultPolarityRemark 12483.516.2932.1248.4174.0025.59PASSVerticalPK 22483.516.2925.6841.9754.0012.03PASSVerticalAV Note: The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic equation with a sample calculation is as follows: Final Test Level =Receiver Reading -Correct Factor Correct Factor = Preamplifier Factor– Antenna Factor–Cable Factor Report No. : EED32S80882701Page 53 of 55 6 Appendix A Refer to Appendix: Bluetooth LE of EED32S80882701 Report No. : EED32S80882701Page 54 of 55 7 PHOTOGRAPHS Refer to Appendix Photographs of Report No. EED32S80882701. Report No. : EED32S80882701Page 55 of 55 Statement 1. This report is considered invalid without approved signature, special seal and the seal on the perforation; 2. The Company Name shown on Report and Address, the sample(s) and sample information was/were provided by the applicant who should be responsible for the authenticity which CTI hasn't verified; 3. The result(s) shown in this report refer(s) only to the sample(s) tested; 4. Unless otherwise stated,the decision rule for conformity reporting is based on Binary Statement for Simple Acceptance Rule stated in ILAC-G8:09/2019/CNAS-GL015:2022; 5. Without written approval of CTI, this report can't be reproduced except in full; *** End of Report ***

Contact Information

Applicant

Jimmy Deng(Regulatory Manager)
[email protected]Fax: 886-2-87971282

Technical Contact

Microlife USA Inc.
[email protected]

1617 Gulf to Bay Blvd., 2nd Floor · Clearwater, Florida, 33755 · United States

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz960.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. Device meets SAR Exemption for Portable use.

Other Applications from Microlife Corporation

U7I-BP3KV1-5W-2

Blood Pressure Monitor

Jan 16, 2026

Equipment Class

DTS - Digital Transmission System
Digital Blood Pressure Monitor - FCC ID U7I-BP3T01-1B - Microlife Corporation
U7I-BP3T01-1B

Digital Blood Pressure Monitor

Jul 17, 2024

Equipment Class

DTS - Digital Transmission System
Peak flow meter - FCC ID U7I-PF200B - Microlife Corporation
U7I-PF200B

Peak flow meter

Aug 31, 2023

Equipment Class

DTS - Digital Transmission System
Digital Blood Pressure Monitor - FCC ID U7I-BP3MX1-1C - Microlife Corporation
U7I-BP3MX1-1C

Digital Blood Pressure Monitor

Jul 30, 2023

Equipment Class

DTS - Digital Transmission System
Digital Blood Pressure Monitor - FCC ID U7I-BP3KY1-3B - Microlife Corporation
U7I-BP3KY1-3B

Digital Blood Pressure Monitor

Jul 13, 2023

Equipment Class

DTS - Digital Transmission System