U7I-BP3KY1-3BDigital Blood Pressure Monitor

Microlife Corporation
Digital Blood Pressure Monitor - FCC ID U7I-BP3KY1-3B - Microlife Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 13, 2023
Application Purpose
Original Equipment
Date of Application
Jul 13, 2023
Equipment Note
Digital Blood Pressure Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Microlife Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

BP3KY1-3B 8 7 9 10 15-B 11 15-C 16 17 12 13 19 20 22 5 14 15-A 18 21 1 2 6 3 4 BP3KY1-3B 1 ON/OFF button 2 Display 3 M-button (memory) 4 Time Button 5 Battery Compartment 6 Cuff Display 7 Systolic Value 8 Diastolic Value 9 Pulse Rate 10 Date/Time 11 Stored Value 12 Traffic Light Indicator 13 Irregular Heartbeat (IHB) Symbol 14 Cuff Fit OK 15 -A: Cuff Signal Indicator«ERR 1» 16 Pulse Indicator 17 Battery Display 18 User Indicator 19 MAM Mode 20 Wrist Position Indicator 21 Active Bluetooth® 22 Average Indicator «MyCheck» Type BF applied part Keep dry Read the instructions carefully before using this device. Intended use: The module is a device intended to measure the systolic and diastolic blood pressure and pulse rate of an adult individual by using a non-invasive oscillometric technique in which an inflatable cuff is wrapped around the wrist for a circumference range from 13.5 to 21.5cm. The device detects the appearance of irregular heartbeat during measurement and gives a warning signal with the reading once the irregular heartbeat is detected. The device can be used in connection with a smart phone running the APP. The memory data can be transferred to the smart phone via Bluetooth. Dear Customer, This device was developed in collaboration with physicians and clinical tests carried out prove its measurement accuracy to be of a very high standard.* If you have any questions, problems or want to order spare parts please contact your local Microlife-Customer Service. Your dealer or pharmacy will be able to give you the address of the Microlife dealer in your country. Alternatively, visit the internet at www.micro- life.com where you will find a wealth of invaluable information on our products. Stay healthy – Microlife AG! * This device is tested according to the ESH protocol and ISO81060-2:2013. -B: Arm Movement Indicator «ERR 2» -C: Cuff Pressure Check «ERR 3» FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to the product are not approved by Microlife USA and could void the user's authority to operate the equipment under FCC jurisdiction. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1) Reorient or relocate the receiving antenna. 2) Increase the separation between the equipment and receiver. 3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4) Consult the dealer or an experienced radio/TV technician for help. This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. FCC ID: U7I-BP3KY1-3B Table of Contents 1. Using the Device for the First Time • Inserting the batteries • Setting the date and time • Selecting standard or MAM mode • Selecting Wrist Position Indicator • Selecting the user 2. Checklist for Taking a Reliable Measurement 3. Taking a Blood Pressure Measurement • How not to store a reading • How do I evaluate my blood pressure? • Average Indicator «MyCheck» • Appearance of the Irregular Heartbeat (IHB) 4. Data Memory • Viewing the average of the last 28 days • Viewing the stored single values • Memory full • Clearing all values 5. Battery Indicator and Battery change • Low battery • Flat battery – replacement • Which batteries and which procedure? • Using rechargeable batteries 6. Bluetooth® Function 7. Error Messages 8. Safety, Care, Accuracy Test and Disposal • Safety and protection • Device care • Cleaning the cuff • Accuracy test • Disposal 9. Guarantee 10. Technical Specifications 1 Using the Device for the First Time Inserting the batteries After you have unpacked your device, first insert the batteries. The battery compartment 5 is on the bottom of the device. Insert the batteries (2 x 1.5 V, size AAA), thereby observing the indicated polarity. Setting the date and time 1. After the new batteries are fitted, the year number flashes in the display. You can set the year by pressing the M-button3. to confirm and then set the month, press the time button4. 2. Press the M-button to set the month. Press the time button to confirm and then set the day. 3. Follow the instructions above to set the day, hour and minutes. 4. Once you have set the minutes and pressed the time button, the date and time are set and the time is displayed. 5. If you want to change the date and time, press and hold the time button down for approx. 3 seconds to enter setting menu. Press time button twice to skip MAM mode/ Wrist Position Indicator setting until the year number starts to flash. Now you can enter the new values as described above. Selecting standard or MAM mode Before each measurement, select standard (single measurement) or MAM mode (automatic triple measurement). In MAM mode, 3 measurements are automatically taken in succession and the result is then automatically analyzed and displayed. Because the blood pressure constantly fluctuates, a result obtained in this way is more reliable than when a single measurement is …

Text truncated - open the document above for the full version.

External Photos

ReportNo.:EED32P80807401Page 32 of 39 10PHOTOGRAPHSOFEUTConstructionalDetails ViewofProduct-1 ViewofProduct-2 ReportNo.:EED32P80807401Page 33 of 39 ViewofProduct-3 ViewofProduct-4 ReportNo.:EED32P80807401Page 34 of 39 ViewofProduct-5 ViewofProduct-6 ReportNo.:EED32P80807401Page 35 of 39 ViewofProduct-7

ID Label/Location Info

BP3KY1-3BFCClabelandsize Thelabelislocatedintheredboxonthebackoftheproduct

Internal Photos

ReportNo.:EED32P80807401Page 35 of 39 ViewofProduct-7 ViewofProduct-8 ReportNo.:EED32P80807401Page 36 of 39 ViewofProduct-9 ViewofProduct-10 ReportNo.:EED32P80807401Page 37 of 39 ViewofProduct-11 ViewofProduct-12 ReportNo.:EED32P80807401Page 38 of 39 ViewofProduct-13 ViewofProduct-14 ReportNo.:EED32P80807401Page 39 of 39 ViewofProduct-15 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofCTI,thisreportcan’tbereproduced exceptinfull. ***EndofReport***

RF Exposure Info

ReportNo.:EED32P80807402Page1of7 1COVERPAGE RFExposureEvaluationReport Product:DigitalBloodpressureMonitor Trademark:Microlife Model/Typereference:BP3KY1-3B SerialNumber:N/A ReportNumber:EED32P80807402 FCCID : U7I-BP3KY1-3B DateofIssue:Jun.15,2023 TestStandards: 47CFRPart1.1307 47CFRPart1.1310 47CFRPart2.1093 447498D04InterimGeneralRF ExposureGuidancev01 Testresult:PASS Preparedfor: MicrolifeCorporation 9F,431,RuiGuangRoad,NeiHu,Taipei11492,Taiwan,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChenTomChen Approvedby:Date:Jun.15,2023 AaronMa CheckNo.:1649010623 ReportNo.:EED32P80807402Page2of7 2Version VersionNo.DateDescription 00Jun.15,2023Original ReportNo.:EED32P80807402Page3of7 3Contents Page 1COVERPAGE....................................................................................................................................................................1 2VERSION............................................................................................................................................................................2 3CONTENTS........................................................................................................................................................................3 4GENERALINFORMATION..............................................................................................................................................4 4.1C LIENT I NFORMATION ...................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT...................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ...........................................................................................4 4.4T EST L OCATION .............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS ......................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS ..........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ................................................................................................5 5SAREVALUATION...........................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT .................................................................................................................6 5.1.1Limits....................................................................................................................................................................6 5.1.2TestProcedure....................................................................................................................................................6 5.1.3EUTRFExposureEvaluation..........................................................................................................................7 ReportNo.:EED32P80807402Page4of7 4GeneralInformation 4.1ClientInformation Applicant:MicrolifeCorporation AddressofApplicant:9F,431,RuiGuangRoad,NeiHu,Taipei11492,Taiwan,China Manufacturer:ONBOElectronic(Shenzhen)Co.,Ltd. AddressofManufacturer:No.138,HuashengRoad,LangkouCommunity,DalangStreet,LonghuaDistrict, Shenzhen,China Factory:ONBOElectronic(Shenzhen)Co.,Ltd. AddressofFactory:No.138,HuashengRoad,LangkouCommunity,DalangStreet,LonghuaDistrict, Shenzhen,China 4.2GeneralDescriptionofEUT ProductName:DigitalBloodpressureMonitor ModelNo.(EUT): BP3KY1-3B TradeMark: Microlife Devicetype: Portable 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHz~2480MHz ModulationType:GFSK TestPowerGrade:Default TestSoftwareofEUT:nRF_DTM AntennaType: Chipantenna AntennaGain: 3dBi PowerSupply: Battery3.0V SampleReceivedDate: Jun.01,2023 SampletestedDate: Jun.01,2023toJun.06,2023 Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/wereprovided bytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32P80807402Page5of7 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32P80807402Page6of7 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1Limits TheSAR-basedexemptionformulaof§1.1307(b)(3)(i)(B),repeatedhereasFormula(B.2),appliesfor singlefixed,mobile,andportableRFsourceswithavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,oflessthanorequaltothethresholdPth(mW). Thismethodshallonlybeusedatseparationdistancesfrom0.5cmto40cmandatfrequenciesfrom 0.3GHzto6GHz(inclusive).PthisgivenbyFormula andfisinGHz,distheseparationdistance(cm),andERP20cmisperFormula(B.1). The1mWBlanketExemptionof§1.1307(b)(3)(i)(A)appliesforsinglefixed,mobile,andportableRF sourceswithavailablemaximumtime-averagedpowerofnomorethan1mW,regardlessofseparation distance. 5.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportNo.:EED32P80807402Page7of7 5.1.3EUTRFExposureEvaluation ForStandalone: ForBLE Frequency (MHz) Separation distance (cm) Max. Conducted Output power (dBm) Antenna Gain (dBi) EIRP…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32P80807401Page 1 of 25 Appendix:BluetoothLE ReportNo.:EED32P80807401Page 2 of 25 Content AppendixA:DTSBandwidth.......................................................................................................3 TestResult.........................................................................................................................3 TestGraphs.......................................................................................................................4 AppendixB:OccupiedChannelBandwidth................................................................................6 TestResult.........................................................................................................................6 TestGraphs.......................................................................................................................7 AppendixC:Maximumconductedoutputpower......................................................................9 TestResult.........................................................................................................................9 TestGraphs.....................................................................................................................10 AppendixD:Maximumpowerspectraldensity.......................................................................12 TestResult.......................................................................................................................12 TestGraphs.....................................................................................................................13 AppendixE:Bandedgemeasurements...................................................................................15 TestResult.......................................................................................................................15 TestGraphs.....................................................................................................................16 AppendixF:ConductedSpuriousEmission..............................................................................17 TestResult.......................................................................................................................17 TestGraphs.....................................................................................................................18 AppendixG:DutyCycle............................................................................................................23 TestResult.......................................................................................................................23 TestGraphs.....................................................................................................................24 ReportNo.:EED32P80807401Page 3 of 25 AppendixA:DTSBandwidth TestResult TestModeAntennaFrequency[MHz] DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24020.6922401.6602402.3520.5PASS 24400.6962439.6682440.3640.5PASS 24800.6762479.6762480.3520.5PASS ReportNo.:EED32P80807401Page 4 of 25 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:EED32P80807401Page 5 of 25 ReportNo.:EED32P80807401Page 6 of 25 AppendixB:OccupiedChannelBandwidth TestResult TestModeAntennaFrequency[MHz] OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24021.06232401.4830 2402.545 3 ------ 24401.04682439.4919 2440.538 7 ------ 24801.04902479.4951 2480.544 1 ------ ReportNo.:EED32P80807401Page 7 of 25 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:EED32P80807401Page 8 of 25 ReportNo.:EED32P80807401Page 9 of 25 AppendixC:Maximumconductedoutputpower TestResult TestModeAntennaFrequency[MHz] ConductedPeak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1MAnt1 2402-2.99≤30PASS 2440-1.99≤30PASS 2480-3.46≤30PASS ReportNo.:EED32P80807401Page 10 of 25 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:EED32P80807401Page 11 of 25 ReportNo.:EED32P80807401Page 12 of 25 AppendixD:Maximumpowerspectraldensity TestResult TestModeAntennaFrequency[MHz]Result[dBm/3kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt1 2402-17.73≤8.00PASS 2440-15.17≤8.00PASS 2480-16.8≤8.00PASS ReportNo.:EED32P80807401Page 13 of 25 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:EED32P80807401Page 14 of 25 ReportNo.:EED32P80807401Page 15 of 25 AppendixE:Bandedgemeasurements TestResult Test Mode AntennaChName Frequency [MHz] RefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 Low2402-3.62-41.17≤-23.62PASS High2480-3.92-47.5≤-23.92PASS ReportNo.:EED32P80807401Page 16 of 25 TestGraphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 ReportNo.:EED32P80807401Page 17 of 25 AppendixF:ConductedSpuriousEmission TestResult TestModeAntennaFrequency[MHz] FreqRange [MHz] RefLevel [dBm] Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 2402 Reference-3.63-3.63---PASS 30~1000-3.63-58.88≤-23.63PASS 1000~265 00 -3.63-50.48≤-23.63PASS 2440 Reference-2.62-2.62---PASS 30~1000-2.62-57.08≤-22.62PASS 1000~265 00 -2.62-47.91≤-22.62PASS 2480 Reference-4.09-4.09---PASS 30~1000-4.09-57.83≤-24.09PASS 1000~265 00 -4.09-47.67≤-24.09PASS ReportNo.:EED32P80807401Page 18 of 25 TestGraphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 ReportNo.:EED32P80807401Page 19 of 25 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 ReportNo.:EED32P80807401Page 20 of 25 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference ReportNo.:EED32P80807401Page 21 of 25 BLE_1M_Ant1_2480_30~1000 BLE_1M_Ant1_2480_1000~26500 ReportNo.:EED32P80807401Page 22 of 25 ReportNo.:EED32P80807401Page 23 of 25 AppendixG:DutyCycle TestResult TestModeAntennaFrequency[MHz] ONTime [ms] Period [ms] DutyCycle [%] DutyCycle Factor[dB] BLE_1MAnt1 24020.440.6369.841.56 24400.440.6369.841.56 24800.440.6369.841.56 ReportNo.:EED32P80807401Page 24 of 25 TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:EED32P80807401Page 25 of 25 ***EndofReport***

Test Report

ReportNo.:EED32P80807401Page1of39 1 COVERPAGE TESTREPORT Product:DigitalBloodpressureMonitor Trademark:Microlife Model/Typereference:BP3KY1-3B SerialNumber:N/A ReportNumber:EED32P80807401 FCCID : U7I-BP3KY1-3B DateofIssue:Jun.15,2023 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: MicrolifeCorporation 9F,431,RuiGuangRoad,NeiHu,Taipei11492,Taiwan,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: MarkChenTomChen Approvedby:Date:Jun.15,2023 AaronMa CheckNo.:1649010623 ReportNo.:EED32P80807401Page 2 of 39 2Content 1COVERPAGE.....................................................................................................................................................................1 2CONTENT............................................................................................................................................................................2 3VERSION.............................................................................................................................................................................3 4TESTSUMMARY...............................................................................................................................................................4 5GENERALINFORMATION...............................................................................................................................................5 5.1C LIENT I NFORMATION ....................................................................................................................................................5 5.2G ENERAL D ESCRIPTIONOF EUT.................................................................................................................................5 5.3T EST C ONFIGURATION ..................................................................................................................................................6 5.4T EST E NVIRONMENT .....................................................................................................................................................7 5.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 5.6T EST L OCATION .............................................................................................................................................................7 5.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2).............................................................................8 6EQUIPMENTLIST..............................................................................................................................................................9 7TESTRESULTSANDMEASUREMENTDATA.........................................................................................................13 7.1A NTENNA R EQUIREMENT ............................................................................................................................................13 7.2M AXIMUM C ONDUCTED O UTPUT P OWER ..................................................................................................................14 7.3DTSB ANDWIDTH ........................................................................................................................................................15 7.4M AXIMUM P OWER S PECTRAL D ENSITY .....................................................................................................................16 7.5B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ...................................................................17 7.6R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................18 8APPENDIXBLE................................................................................................................................................................29 9PHOTOGRAPHSOFTESTSETUP..............................................................................................................................30 10PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS...................................................................................32 ReportNo.:EED32P80807401Page 3 of 39 3Version VersionNo.DateDescription 00Jun.15,2023Original ReportNo.:EED32P80807401Page 4 of 39 4TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 N/A DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32P80807401Page 5 of 39 5GeneralInformation 5.1ClientInformation Applicant: MicrolifeCorporation AddressofApplicant: 9F,431,RuiGuangRoad,NeiHu,Taipei11492,Taiwan,China Manufacturer: ONBOElectronic(Shenzhen)Co.,Ltd. AddressofManufacturer: No.138,HuashengRoad,LangkouCommunity,DalangStreet,Longhua District,Shenzhen,China Factory: ONBOElectronic(Shenzhen)Co.,Ltd. AddressofFactory: No.138,HuashengRoad,LangkouCommunity,DalangStreet,Longhua District,Shenzhen,China 5.2GeneralDescriptionofEUT ProductName: DigitalBloodpressureMonitor ModelNo.: BP3KY1-3B Trademark: Microlife Devicetype: Portable OperationFrequency:2402MHz~2480MHz ModulationType:GFSK TransferRate: 1Mbps NumberofChannel:40 An…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.:EED32P80807401Page 30 of 39 9PHOTOGRAPHSOFTESTSETUP RadiatedspuriousemissionTestSetup-1 (Below1GHz) RadiatedspuriousemissionTestSetup-2( Above1GHz) ReportNo.:EED32P80807401Page 31 of 39 RadiatedspuriousemissionTestSetup-3( Above1GHz) Thereareabsorbingmaterialsundertheground.

Contact Information

Applicant

Jimmy Deng(Regulatory Manager)
[email protected]886-2-87971288Fax: 886-2-87971282

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]N/A

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz600.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Microlife Corporation

U7I-EBPHKW2-D

Digital Non-invasive Blood Pressure and Electrocardiogram Monitor

Jul 03, 2026

Equipment Class

DTS - Digital Transmission System
U7I-BP3KV1-5W-2

Blood Pressure Monitor

Jan 16, 2026

Equipment Class

DTS - Digital Transmission System
Digital Blood Pressure Monitor - FCC ID U7I-BP3T01-1B - Microlife Corporation
U7I-BP3T01-1B

Digital Blood Pressure Monitor

Jul 17, 2024

Equipment Class

DTS - Digital Transmission System
Peak flow meter - FCC ID U7I-PF200B - Microlife Corporation
U7I-PF200B

Peak flow meter

Aug 31, 2023

Equipment Class

DTS - Digital Transmission System
Digital Blood Pressure Monitor - FCC ID U7I-BP3MX1-1C - Microlife Corporation
U7I-BP3MX1-1C

Digital Blood Pressure Monitor

Jul 30, 2023

Equipment Class

DTS - Digital Transmission System