FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Microlife Corporation/
  3. U7I-BP3SK1-3B-2

U7I-BP3SK1-3B-2Digital Blood Pressure Monitor

Microlife Corporation
Digital Blood Pressure Monitor - FCC ID U7I-BP3SK1-3B-2 - Microlife Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 15, 2020
Application Purpose
Original Equipment
Date of Application
Nov 15, 2020
Equipment Note
Digital Blood Pressure Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Microlife Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WatchBP Office Professional Automated Office Blood Pressure Monitor Instruction Manual BP 3SK1-3B 4 Indications For Use The Microlife Upper Arm Automatic Digital Blood Pressure Monitor,Model WatchBP Office (BP3SK1-3B) is a non-invasive digital blood pressure device using oscillometric technique and an upper-arm blood pressure cuff to measure systolic and diastolic blood pressures, pulse rate, mean arterial pressure (MAP) for use in adults and pediatrics (but not neonates) with arm cuff circumference sizes ranging from 14 -52 cm. The device can accurately measure blood pressure in pregnant patients including those with known or suspected pre-eclampsia. The device provides aortic blood pressure parameters, includes central systolic blood pressure (cSBP), central pulse pressure (cPP) and central diastolic blood pressure (cDBP), non-invasively through the use of a brachial cuff. The device detects the appearance of atrial fibrillation during measurement and gives a warning signal together with the measured blood pressure value if atrial fibrillation is detected . The memory data can be transferred to the PC (personal computer) running the WatchBP Analyzer software by connecting the monitor via USB cable or Bluetooth. The device is for hospital use only. WatchBP product support: https://www.microlife.com/professional-products WatchBP Software support: https://www.microlife.com/support/software-professional-products Developers support: https://www.microlife.com/developers1 Federal Communications Commission (FCC) Statement changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. EN 5 WatchBP Office Product description ・Contents ...............................................................................................................................6 ・Model Type ............................................................................................................................6 ・Upgrading the version of the device .........................................................................................6 ・Product Overview ..................................................................................................................7 ・Display ..................................................................................................................................7 Initial set up ・Attaching the power plug to the power adapter ........................................................................8 ・Power ON/OFF ......................................................................................................................8 ・Set the date, time and the safeguard pressure .........................................................................8 Before using the device ・Selecting the correct cuff ........................................................................................................9 ・Fitting the cuff properly ............................................................................................................9 Taking measurements in MANUAL and AUTO mode ・Turn on the power .................................................................................................................10 ・Connect the cuff to the device ...............................................................................................10 ・Select an operation mode .....................................................................................................10 ・Settings of AUTO mode ...................................................................................................10-11 ・Taking measurement in AUTO mode .....................................................................................12 ・Viewing stored values ...........................................................................................................12 ・MANUAL mode Settings .......................................................................................................12 ・Taking measurement in MANUAL mode ................................................................................13 Special Functions ・Screening for atrial fibrillation during blood pressure measurement .........................................14 ・About Atrial Fibrillation ..........................................................................................................14 ・Central blood press…

Text truncated - open the document above for the full version.

External Photos

ReportNo.:EED32M00147801Page 53 of 68 PHOTOGRAPHSOFEUTConstructionalDetails TestmodelNo.:BP3SK1-3B ViewofProduct-1 ViewofProduct-2 ReportNo.:EED32M00147801Page 54 of 68 ViewofProduct-3 ViewofProduct-4 ReportNo.:EED32M00147801Page 55 of 68 ViewofProduct-5 ViewofProduct-6 ReportNo.:EED32M00147801Page 56 of 68 ViewofProduct-7 ViewofProduct-8 ReportNo.:EED32M00147801Page 57 of 68 ViewofProduct-9 ViewofProduct-10 ReportNo.:EED32M00147801Page 58 of 68 ViewofProduct-11 ViewofProduct-12

ID Label/Location Info

BPB

Internal Photos

ReportNo.:EED32M00147801Page 58 of 68 ViewofProduct-11 ViewofProduct-12 ReportNo.:EED32M00147801Page 59 of 68 ViewofProduct-13 ViewofProduct-14 ReportNo.:EED32M00147801Page 60 of 68 ViewofProduct-15 ViewofProduct-16 ReportNo.:EED32M00147801Page 61 of 68 ViewofProduct-17 ViewofProduct-18 ReportNo.:EED32M00147801Page 62 of 68 ViewofProduct-19 ViewofProduct-20 ReportNo.:EED32M00147801Page 63 of 68 ViewofProduct-21 ViewofProduct-22 ReportNo.:EED32M00147801Page 64 of 68 ViewofProduct-23 ViewofProduct-24 ReportNo.:EED32M00147801Page 65 of 68 ViewofProduct-25 ViewofProduct-26 ReportNo.:EED32M00147801Page 66 of 68 ViewofProduct-27 ViewofProduct-28 ReportNo.:EED32M00147801Page 67 of 68 ViewofProduct-29 ViewofProduct-30 ReportNo.:EED32M00147801Page 68 of 68 ViewofProduct-31 ***EndofReport*** Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofCTI,thisreportcan’tbereproduced exceptinfull.

RF Exposure Info

ReportNo.:EED32M00147802Page1of8 1COVERPAGE RFExposureEvaluationReport Product:DigitalBloodPressureMonitor Trademark: Model/Typereference:BP3SK1-3B,WatchBPOffice SerialNumber:N/A ReportNumber:EED32M00147802 FCCID: U7I-BP3SK1-3B-2 DateofIssue:Aug.10,2020 TestStandards: 47CFRPart1.1307 47CFRPart2.1093 KDB447498D01GeneralRFExposureGuidancev06 Testresult:PASS Preparedfor: MicrolifeCorporation 9F,431,RuiGuangRoad,NeiHu,Taipei11492,Taiwan Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby: SmileZhongJokYang Approvedby:Date:Aug.10,2020 SamChuang CheckNo.:3970395814 ReportNo.:EED32M00147802Page2of8 2Version VersionNo.DateDescription 00Aug.10,2020Original ReportNo.:EED32M00147802Page3of8 3Contents Page 1COVERPAGE....................................................................................................................................................................1 2VERSION.............................................................................................................................................................................2 3CONTENTS.........................................................................................................................................................................3 4GENERALINFORMATION..............................................................................................................................................4 4.1C LIENT I NFORMATION ...................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD .......................................................................................4 4.4T EST L OCATION ............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS .....................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS .........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER .............................................................................................5 5SAREVALUATION...........................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT ..............................................................................................................6 5.1.1StandardRequirement......................................................................................................................................6 5.1.2Limits....................................................................................................................................................................6 5.1.3EUTRFExposure..............................................................................................................................................7 PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS..........................................................................................8 ReportNo.:EED32M00147802Page4of8 4GeneralInformation 4.1ClientInformation Applicant: MicrolifeCorporation AddressofApplicant: 9F,431,RuiGuangRoad,NeiHu,Taipei11492,Taiwan Manufacturer: ONBOElectronic(Shenzhen)Co.,Ltd. AddressofManufacturer: No.138,HuashengRoad,LangkouCommunity,DalangStreet, LonghuaDistrict,Shenzhen,China Factory: ONBOElectronic(Shenzhen)Co.,Ltd. AddressofFactory: No.138,HuashengRoad,LangkouCommunity,DalangStreet, LonghuaDistrict,Shenzhen,China 4.2GeneralDescriptionofEUT ProductName:DigitalBloodPressureMonitor ModelNo.(EUT): BP3SK1-3B,WatchBPOffice TestModelNo.: BP3SK1-3B TradeMark: EUTSupportsRadios application: 4.2BTSinglemode,2402MHzto2480MHz 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHzto2480MHz ModulationType:GFSK TestPowerGrade:Default TestSoftwareofEUT:NRF AntennaType:CeramicAntenna AntennaGain:0dBi PowerSupply: Adapter MODELNo:UE15WCP1-075150SPA PARTNo:UE140425DGHD03-R INPUT:100-240V~50/60Hz,500mA OUTPUT:7.5V  1.5A Battery GPRHC252C236 GP250AAHC4BMXZ 4.8V2400mAh MaxConductedPeak OutputPower: BT:-8.24dBm TheMaxConductedPeakOutputPowerdatarefertothereport EED32M00147801 SampleReceivedDate: May28,2020 SampletestedDate: May28,2020toJun.28,2020 Thetestedsample(s)andthesampleinformationareprovidedbytheclient. ModelNo.:BP3SK1-3B,WatchBPOffice OnlythemodelBP3SK1-3Bwastested,sincetheTheirelectricalcircuitdesign,layout,components used,internalwiring,softwareandouterdecorationareidentical.Onlythemodelnamesaredifferent. Thetestedproducthastwomodelnames,WatchBPOfficeisthemarketmodelname;BP3SK1-3Bis thefactoryinternalmodelname. ReportNo.:EED32M00147802Page5of8 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32M00147802Page6of8 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheador bodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions,bymeasurementor numericalsimulation,isnotrequiredwhenthec…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32M00147801Page1of68 1 COVERPAGE TESTREPORT Product:DigitalBloodPressureMonitor Trademark: Model/Typereference:BP3SK1-3B,WatchBPOffice SerialNumber:N/A ReportNumber:EED32M00147801 FCCID: U7I-BP3SK1-3B-2 DateofIssue:Aug.10,2020 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: MicrolifeCorporation 9F,431,RuiGuangRoad,NeiHu,Taipei11492,Taiwan Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: SmileZhongJokYang Approvedby:Date:Aug.10,2020 SamChuang CheckNo.:3970395814 ReportNo.:EED32M00147801Page 2 of 68 2Version VersionNo.DateDescription 00Aug.10,2020Original ReportNo.:EED32M00147801Page 3 of 68 3TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) ANSIC63.10-2013PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 ANSIC63.10-2013PASS ConductedPeakOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) ANSIC63.10-2013PASS 6dBOccupiedBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) ANSIC63.10-2013PASS PowerSpectralDensity 47CFRPart15SubpartCSection 15.247(e) ANSIC63.10-2013PASS Band-edgeforRF ConductedEmissions 47CFRPart15SubpartCSection 15.247(d) ANSIC63.10-2013PASS RFConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) ANSIC63.10-2013PASS RadiatedSpurious Emissions 47CFRPart15SubpartCSection 15.205/15.209 ANSIC63.10-2013PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15SubpartCSection 15.205/15.209 ANSIC63.10-2013PASS Remark: TestaccordingtoANSIC63.4-2014&ANSIC63.10-2013. Thetestedsample(s)andthesampleinformationareprovidedbytheclient. ModelNo.:BP3SK1-3B,WatchBPOffice OnlythemodelBP3SK1-3Bwastested,sincetheTheirelectricalcircuitdesign,layout,componentsused, internalwiring,softwareandouterdecorationareidentical.Onlythemodelnamesaredifferent.Thetested producthastwomodelnames,WatchBPOfficeisthemarketmodelname;BP3SK1-3Bisthefactoryinternal modelname. ReportNo.:EED32M00147801Page 4 of 68 4Content 1COVERPAGE.....................................................................................................................................................................1 2VERSION..............................................................................................................................................................................2 3TESTSUMMARY................................................................................................................................................................3 4CONTENT.............................................................................................................................................................................4 5TESTREQUIREMENT.......................................................................................................................................................5 5.1T ESTSETUP ...................................................................................................................................................................5 5.1.1ForConductedtestsetup...................................................................................................................................5 5.1.2ForRadiatedEmissionstestsetup...................................................................................................................5 5.1.3ForConductedEmissionstestsetup...............................................................................................................6 5.2T EST E NVIRONMENT ......................................................................................................................................................6 5.3T EST C ONDITION ............................................................................................................................................................6 6GENERALINFORMATION...............................................................................................................................................7 6.1C LIENT I NFORMATION ....................................................................................................................................................7 6.2G ENERAL D ESCRIPTIONOF EUT..................................................................................................................................7 6.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ........................................................................................7 6.4D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................8 6.5T EST L OCATION .............................................................................................................................................................8 6.6D EVIATIONFROM S TANDARDS ......................................................................................................................................8 6.7A BNORMALITIESFROM S TANDARD C ONDITIONS ..........................................................................................................8 6.8O THER I NFORMATION R EQUESTEDBYTHE C USTOMER ..............................................................................................8 6.9M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2)..............................................................................9 7EQUIPMENTLIST............................................................................................................................................................10 8RADIOTECHNICALREQUIREMENTSSPECIFICATION........................................................................................13 EUTDUTYCYCLE.................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

ReportNo.:EED32M00147801Page 50 of 68 PHOTOGRAPHSOFTESTSETUP TestmodelNo.:BP3SK1-3B RadiatedspuriousemissionTestSetup-1(Below30MHz) RadiatedspuriousemissionTestSetup-2(Below1GHz) ReportNo.:EED32M00147801Page 51 of 68 RadiatedspuriousemissionTestSetup-3(Above1GHz) RadiatedspuriousemissionTestSetup-4(Above1GHz) Thereareabsorbingmaterialsundertheground. ReportNo.:EED32M00147801Page 52 of 68 ConductedEmissionsTestSetup

Contact Information

Applicant

Jimmy Deng(Regulatory Manager)
[email protected]886-2-87971288Fax: 886-2-87971282

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]N/A

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz100.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted.

Other Applications from Microlife Corporation

U7I-EBPHKW2-D

Digital Non-invasive Blood Pressure and Electrocardiogram Monitor

Jul 03, 2026

Equipment Class

DTS - Digital Transmission System
U7I-BP3KV1-5W-2

Blood Pressure Monitor

Jan 16, 2026

Equipment Class

DTS - Digital Transmission System
Digital Blood Pressure Monitor - FCC ID U7I-BP3T01-1B - Microlife Corporation
U7I-BP3T01-1B

Digital Blood Pressure Monitor

Jul 17, 2024

Equipment Class

DTS - Digital Transmission System
Peak flow meter - FCC ID U7I-PF200B - Microlife Corporation
U7I-PF200B

Peak flow meter

Aug 31, 2023

Equipment Class

DTS - Digital Transmission System
Digital Blood Pressure Monitor - FCC ID U7I-BP3MX1-1C - Microlife Corporation
U7I-BP3MX1-1C

Digital Blood Pressure Monitor

Jul 30, 2023

Equipment Class

DTS - Digital Transmission System