U7I-FR1DQ1-BInfrared Forehead Thermometer

Microlife Corporation
Infrared Forehead Thermometer - FCC ID U7I-FR1DQ1-B - Microlife Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 25, 2022
Application Purpose
Original Equipment
Date of Application
Sep 25, 2022
Equipment Note
Infrared Forehead Thermometer
Frequency Range
2402.00000000 - 2480.00000000
Company
Microlife Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FR1DQ1-B Infrared Forehead Thermometer Distributed by: Microlife USA, Inc. 1617 Gulf to Bay Blvd.,Floor 2 Clearwater,FL 33755,UNITED STATES Phone: (727)-442-5353 www.microlifeusa.com Made in China ○ 8 ○ 9 ○ 10 ○ 11 ○ 12 ○ 13 ○ 14 ○ 15 ○ 16 ○ 17 ○ 18 ○ 19 ○ 20 ○ 21 ○ 22 ○ 23 ○ 24 ○ 25 ○ 26 ○ 27 ○ 1Measuring sensor ○ 2Tracking light ○ 3Display ○ 4START/IO button ○ 5MEMO button ○ 6MODE ○ 7Battery compartment cover ○ 8 All segments displayed ○ 9Ready for measuring ⑩Start the measurement ⑪Measurement complete ○ 12Body mode ○ 13Object mode ○ 14Low battery indicator ○ 15Changing between Celsius and Fahrenheit ○ 16Recall mode ○ 17Recall the last 30 readings ⑱Measured temperature too high ⑲Measured temperature too low ○ 20Ambient temperature too high ○ 21Ambient temperature too low ○ 22Error function display ○ 23Blank display ○ 24Flat battery ○ 25 Date/Time ○ 26Beeper function setting ○ 27Protective cap Read the instructions carefully before using this device Type BF applied part Overview This Microlife thermometer is a high-quality product incorporating the latest technology and tested in accordance with international standards. With its unique technology, this device can provide a stable, heat-interference-free reading with each measurement. The device performs a self-t est every time it is switched on to always guarantee the specified accuracy of any measurement. This Microlife thermometer is intended for measurement and monitoring not only the temperature of forehead of human body, but also the t emperature of object. This thermometer has been clinically tested and proven to be safe and accurate when used in accordance to the operating instruction manual. Please read through these instructions carefully in order for you to understand all functions and safety information. Indication For Use The Microlife Infrared Forehead Thermometer Model FR1DQ1-B is intended for the intermittent measurement and monitoring of human body temperature. The device is indicated for use by people of all ages in the home. The device can be used in connection with a smart phone running the «Microlife Connected Health +» APP. The memory data can be transferred to the smart phone via Bluetooth. Table of Contents 1.The Advantages of this Thermometer •Measures in a matter of seconds •Measurement with distance control •Multiple uses (wide range of measurement) •Accurate and reliable •Gentle and easy to use •Multiple readings recall •Safe and hygienic •Fever alarm •Guidance system for self-measurement •Bluetooth function 2.Important Safety Instructions 3.How this Thermometer measures Temperature 4.Control Displays and Symbols 5.Setting Date, Time and Beeper Functions 6.Changing measurement mode 7.Directions for Use •Measuring in body mode with distance control •Measuring in object mode without distance control 8.Changing between Celsius and Fahrenheit 9.How to recall & delete 30 readings in Memory Mode 10. Bluetooth® Function - App Quick start guide - Downloading the «Microlife Connected Health+» App - Setup User Profile - Transfer Data - Bluetooth® Icon Indicator - Notes - Wireless communication interference 11.Error Messages 12.Cleaning and Disinfecting 13.Battery Replacement 14.Guarantee 15. Technical Specifications 16. www.microlife.com 1.The Advantages of this Thermometer Measures in a matter of seconds The innovative infrared technology allows the measurement without even touching the object. This guarantees safe and sanitary measurements within seconds. Measurement with distance control The device will show good on display when the device detects the distance is appropriate within 5 cm. Multiple uses (wide range of measurement) This thermometer offers a wide range of measurement from 0.1 – 99.9 °C / 32.2 - 211.8 °F, meaning the unit can be used to measure body temperature or it also has a feature allowing it to be used to measure surface temperature of the following examples: •Milk surface temperature in a baby's bottle •Surface temperature of a baby's bath Accurate and reliable The unique probe assembly construction incorporates an advanced infrared sensor, ensuring that each measurement is accurate and reliable. Gentle and easy to use •The ergonomic design enables simple and easy use of the thermometer. •This thermometer can even be used on a sleeping child without causing any interruption. •This thermometer is quick, t herefore child friendly. Multiple readings recall Users will be able to recall the last 30 readings with a record of both time and date when entering the recall mode, enabling efficient tracking of temperature variations. Safe and hygienic •No direct skin contact •No risk of broken glass or mercury ingestion. •Children should be used under the care of adults to avoid danger caused by accidental ingestion Fever alarm 10 short beeps with a red LCD backlight for 5secs and time and date switch every 1 sec alert the patient that he/ she may have a temperature equal to or higher than 37.5 °C. Guidance system for self-measurement A blue tracking light shows the user that the device is at the right distance and ready to take a measurement. Bluetooth function This device connects to the «Microlife Connected Health+» App by using Bluetooth®4.2 and enables monitoring of temperature 2. Important Safety Instructions • Follow instructions for use. This document provides important product operation and safety information regarding this device. Please read this document thoroughly before using the device and keep for future reference. • This device may only be used for the purposes described in these instructions. The manufacturer cannot be held liable for damage caused by incorrect application. • Never immerse this device in water or other liquids. For cleaning, please follow the instructions in the «Cleaning and Disinfecting» section. • Do not use this device if you think it is damaged or notice anything unusual. • Never open this device. • A basic physiological effect called vasoconstriction can occur in the ea…

Text truncated - open the document above for the full version.

External Photos

ReportNo.:EED32O81190401Page 30 of 39 10PHOTOGRAPHSOFEUTConstructionalDetails TestmodelNo.:FR1DQ1-B ViewofProduct-1 ViewofProduct-2 ReportNo.:EED32O81190401Page 31 of 39 ViewofProduct-3 ViewofProduct-4 ReportNo.:EED32O81190401Page 32 of 39 ViewofProduct-5 ViewofProduct-6

Internal Photos

ReportNo.:EED32O81190401Page 33 of 39 ViewofProduct-7 ViewofProduct-8 ReportNo.:EED32O81190401Page 34 of 39 ViewofProduct-9 ViewofProduct-10 ReportNo.:EED32O81190401Page 35 of 39 ViewofProduct-11 ViewofProduct-12 ReportNo.:EED32O81190401Page 36 of 39 ViewofProduct-13 ViewofProduct-14 ReportNo.:EED32O81190401Page 37 of 39 ViewofProduct-15 ViewofProduct-16 ReportNo.:EED32O81190401Page 38 of 39 ViewofProduct-17 ViewofProduct-18 ReportNo.:EED32O81190401Page 39 of 39 ViewofProduct-19 Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthis reportreferonlytothesample(s)tested.WithoutwrittenapprovalofCTI,thisreportcan’tbereproduced exceptinfull. ***EndofReport***

RF Exposure Info

ReportNo.:EED32O81190402Page1of7 1COVERPAGE RFExposureEvaluationReport Product:InfraredForeheadThermometer Trademark:Microlife Model/Typereference:FR1DQ1-B SerialNumber:N/A ReportNumber: EED32O81190402 FCCID:U7I-FR1DQ1-B DateofIssue:Sep.23,2022 TestStandards: 47CFRPart1.1307 47CFRPart1.1310 47CFRPart2.1093(portabledevices) 447498D04InterimGeneralRF ExposureGuidancev01 Testresult:PASS Preparedfor: MicrolifeCorporation 9F,NO.431,RuiGuangRoad,Nei-Hu,Taipei,11492,Taiwan,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: FrazerLiAaronMa Approvedby:Date:Sep.23,2022 AaronMa CheckNo.:2502050822 ReportNo.:EED32O81190402Page2of7 2Version VersionNo.DateDescription 00Sep.23,2022Original ReportNo.:EED32O81190402Page3of7 3Contents Page 1COVERPAGE....................................................................................................................................................................1 2VERSION.............................................................................................................................................................................2 3CONTENTS.........................................................................................................................................................................3 4GENERALINFORMATION..............................................................................................................................................4 4.1C LIENT I NFORMATION ....................................................................................................................................................4 4.2G ENERAL D ESCRIPTIONOF EUT....................................................................................................................................4 4.3P RODUCT S PECIFICATIONSUBJECTIVETOTHISSTANDARD ...........................................................................................4 4.4T EST L OCATION ..............................................................................................................................................................5 4.5D EVIATIONFROM S TANDARDS .......................................................................................................................................5 4.6A BNORMALITIESFROM S TANDARD C ONDITIONS ...........................................................................................................5 4.7O THER I NFORMATION R EQUESTEDBYTHE C USTOMER .................................................................................................5 5SAREVALUATION...........................................................................................................................................................6 5.1RFE XPOSURE C OMPLIANCE R EQUIREMENT ..................................................................................................................6 5.1.1Limits....................................................................................................................................................................6 5.1.2TestProcedure.....................................................................................................................................................6 5.1.3EUTRFExposureEvaluation..........................................................................................................................7 ReportNo.:EED32O81190402Page4of7 4GeneralInformation 4.1ClientInformation Applicant: MicrolifeCorporation AddressofApplicant: 9F,NO.431,RuiGuangRoad,Nei-Hu,Taipei,11492,Taiwan,China Manufacturer: ONBOElectronic(Shenzhen)Co.,Ltd. AddressofManufacturer: No.138,HuashengRoad,LangkouCommunity,DalangStreet,LonghuaDistrict, Shenzhen,China Factory: ONBOElectronic(Shenzhen)Co.,Ltd. AddressofFactory: No.138,HuashengRoad,LangkouCommunity,DalangStreet,LonghuaDistrict, Shenzhen,China 4.2GeneralDescriptionofEUT ProductName: InfraredForeheadThermometer ModelNo.:FR1DQ1-B TestModelNo.:FR1DQ1-B TradeMark:Microlife 4.3 ProductSpecificationsubjectivetothisstandard FrequencyRange:2402MHz~2480MHz ModulationType:GFSK TestPowerGrade:Default(Powerlevelisbuilt-insetparametersandcannotbechangedand selected) TestSoftwareofEUT:nRF_DTM.exe(manufacturerdeclare) AntennaType: Internalantenna AntennaGain: 0dBi PowerSupply: Battery:DC3.0V TestVoltage:DC3.0V SampleReceivedDate: Aug.05,2022 SampletestedDate: Sep.09,2022toSep.19,2022 Remark: CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwas/wereprovided bytheapplicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32O81190402Page5of7 4.4TestLocation Alltestswereperformedat: CentreTestingInternationalGroupCo.,Ltd BuildingC,HongweiIndustrialParkBlock70,Bao'anDistrict,Shenzhen,China Telephone:+86(0)75533683668Fax:+86(0)75533683385 Notestsweresub-contracted. FCCDesignationNo.:CN1164 4.5DeviationfromStandards None. 4.6AbnormalitiesfromStandardConditions None. 4.7OtherInformationRequestedbytheCustomer None. ReportNo.:EED32O81190402Page6of7 5SAREvaluation 5.1RFExposureComplianceRequirement 5.1.1Limits TheSAR-basedexemptionformulaof§1.1307(b)(3)(i)(B),repeatedhereasFormula(B.2),appliesfor singlefixed,mobile,andportableRFsourceswithavailablemaximumtime-averagedpoweroreffective radiatedpower(ERP),whicheverisgreater,oflessthanorequaltothethresholdPth(mW). Thismethodshallonlybeusedatseparationdistancesfrom0.5cmto40cmandatfrequenciesfrom 0.3GHzto6GHz(inclusive).PthisgivenbyFormula andfisinGHz,distheseparationdistance(cm),andERP20cmisperFormula(B.1). The1mWBlanketExemptionof§1.1307(b)(3)(i)(A)appliesforsinglefixed,mobile,andportableRF sourceswithavailablemaximumtime-averagedpowerofnomorethan1mW,regardlessofseparation distance. 5.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. ReportNo.:EED32O81190402Page7of7…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32O81190401Page1of39 1 COVERPAGE TESTREPORT Product:InfraredForeheadThermometer Trademark:Microlife Model/Typereference:FR1DQ1-B SerialNumber:N/A ReportNumber:EED32O81190401 FCCID:U7I-FR1DQ1-B DateofIssue:Sep.23,2022 TestStandards: 47CFRPart15SubpartC Testresult:PASS Preparedfor: MicrolifeCorporation 9F,NO.431,RuiGuangRoad,Nei-Hu,Taipei,11492,Taiwan,China Preparedby : CentreTestingInternationalGroupCo.,Ltd. HongweiIndustrialZone,Bao’an70District, Shenzhen,Guangdong,China TEL:+86-755-33683668 FAX:+86-755-33683385 Compiledby:Reviewedby: FrazerLiAaronMa Approvedby:Date:Sep.23,2022 AaronMa CheckNo.:2502050822 ReportNo.:EED32O81190401Page 2 of 39 2Content 1COVERPAGE.....................................................................................................................................................................1 2CONTENT.............................................................................................................................................................................2 3VERSION..............................................................................................................................................................................3 4TESTSUMMARY................................................................................................................................................................4 5GENERALINFORMATION...............................................................................................................................................5 5.1C LIENT I NFORMATION ....................................................................................................................................................5 5.2G ENERAL D ESCRIPTIONOF EUT..................................................................................................................................5 5.3T EST C ONFIGURATION ...................................................................................................................................................6 5.4T EST E NVIRONMENT ......................................................................................................................................................7 5.5D ESCRIPTIONOF S UPPORT U NITS ...............................................................................................................................7 5.6T EST L OCATION .............................................................................................................................................................7 5.7M EASUREMENT U NCERTAINTY (95% CONFIDENCELEVELS , K =2)..............................................................................8 6EQUIPMENTLIST..............................................................................................................................................................9 7TESTRESULTSANDMEASUREMENTDATA..........................................................................................................11 7.1A NTENNA R EQUIREMENT .............................................................................................................................................11 7.2M AXIMUM C ONDUCTED O UTPUT P OWER ...................................................................................................................12 7.3DTSB ANDWIDTH .........................................................................................................................................................13 7.4M AXIMUM P OWER S PECTRAL D ENSITY ......................................................................................................................14 7.5B AND E DGEMEASUREMENTSAND C ONDUCTED S PURIOUS E MISSION ....................................................................15 7.6R ADIATED S PURIOUS E MISSION &R ESTRICTEDBANDS ...........................................................................................16 8APPENDIXA......................................................................................................................................................................27 9PHOTOGRAPHSOFTESTSETUP..............................................................................................................................28 10PHOTOGRAPHSOFEUTCONSTRUCTIONALDETAILS....................................................................................30 ReportNo.:EED32O81190401Page 3 of 39 3Version VersionNo.DateDescription 00Sep.23,2022Original ReportNo.:EED32O81190401Page 4 of 39 4TestSummary TestItemTestRequirementResult AntennaRequirement 47CFRPart15SubpartCSection 15.203/15.247(c) PASS ACPowerLineConducted Emission 47CFRPart15SubpartCSection 15.207 N/A DTSBandwidth 47CFRPart15SubpartCSection 15.247(a)(2) PASS MaximumConductedOutput Power 47CFRPart15SubpartCSection 15.247(b)(3) PASS MaximumPowerSpectral Density 47CFRPart15SubpartCSection15.247(e)PASS BandEdgeMeasurements 47CFRPart15SubpartCSection 15.247(d) PASS ConductedSpurious Emissions 47CFRPart15SubpartCSection 15.247(d) PASS RadiatedSpuriousEmission& Restrictedbands 47CFRPart15SubpartCSection 15.205/15.209 PASS Remark: N/A:Theproductispoweredbybattery. CompanyNameandAddressshownonReport,thesample(s)andsampleInformationwereprovidedbythe applicantwhoshouldberesponsiblefortheauthenticitywhichCTIhasn’tverified. ReportNo.:EED32O81190401Page 5 of 39 5GeneralInformation 5.1ClientInformation Applicant:MicrolifeCorporation AddressofApplicant:9F,NO.431,RuiGuangRoad,Nei-Hu,Taipei,11492,Taiwan,China Manufacturer:ONBOElectronic(Shenzhen)Co.,Ltd. AddressofManufacturer:No.138,HuashengRoad,LangkouCommunity,DalangStreet,Longhua District,Shenzhen,China Factory:ONBOElectronic(Shenzhen)Co.,Ltd. AddressofFactory:No.138,HuashengRoad,LangkouCommunity,DalangStreet,Longhua District,Shenzhen,China 5.2GeneralDescriptionofEUT ProductName: InfraredForeheadThermometer ModelNo.: FR1DQ1-B TestModelNo.: FR1DQ1-B Trademark: Microlife ProductType: MobilePortableFixLocation Oper…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:EED32O81190401Page 1 of 24 Appendix:BluetoothLE ReportNo.:EED32O81190401Page 2 of 24 Contents Contents .............................................................................................................................................................................................................................. 2 DutyCycle ........................................................................................................................................................................................................................... 3 MaximumPeakConductedOutputPower ..................................................................................................................................................................... 6 -6dBBandwidth .................................................................................................................................................................................................................. 9 OccupiedChannelBandwidth ....................................................................................................................................................................................... 12 MaximumPowerSpectralDensityLevel ..................................................................................................................................................................... 15 BandEdge ........................................................................................................................................................................................................................ 18 ConductedRFSpuriousEmission ................................................................................................................................................................................ 21 ReportNo.:EED32O81190401Page 3 of 24 DutyCycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTBLE1M2402Ant169.441.582.3 NVNTBLE1M2440Ant169.521.582.3 NVNTBLE1M2480Ant169.521.582.3 ReportNo.:EED32O81190401Page 4 of 24 TestGraphs DutyCycleNVNTBLE1M2402MHzAnt1 DutyCycleNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81190401Page 5 of 24 DutyCycleNVNTBLE1M2480MHzAnt1 ReportNo.:EED32O81190401Page 6 of 24 MaximumPeakConductedOutputPower ConditionMode Frequency (MHz) Antenna ConductedPower (dBm) DutyFactor (dB) TotalPower (dBm) Limit (dBm) Verdict NVNT BLE 1M 2402Ant11.180 1.18 30Pass NVNT BLE 1M 2440Ant1-0.350-0.3530Pass NVNT BLE 1M 2480Ant1-2.710-2.7130Pass ReportNo.:EED32O81190401Page 7 of 24 TestGraphs PeakPowerNVNTBLE1M2402MHzAnt1 PeakPowerNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81190401Page 8 of 24 PeakPowerNVNTBLE1M2480MHzAnt1 ReportNo.:EED32O81190401Page 9 of 24 -6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.7070.5Pass NVNTBLE1M2440Ant10.7170.5Pass NVNTBLE1M2480Ant10.7050.5Pass ReportNo.:EED32O81190401Page 10 of 24 TestGraphs -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81190401Page 11 of 24 -6dBBandwidthNVNTBLE1M2480MHzAnt1 ReportNo.:EED32O81190401Page 12 of 24 OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.181 NVNTBLE1M2440Ant11.288 NVNTBLE1M2480Ant11.176 ReportNo.:EED32O81190401Page 13 of 24 TestGraphs OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81190401Page 14 of 24 OBWNVNTBLE1M2480MHzAnt1 ReportNo.:EED32O81190401Page 15 of 24 MaximumPowerSpectralDensityLevel ConditionMode Frequency (MHz) Antenna ConductedPSD (dBm/3kHz) DutyFactor (dB) TotalPSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT BLE 1M 2402Ant1-13.450-13.458Pass NVNT BLE 1M 2440Ant1-15.650-15.658Pass NVNT BLE 1M 2480Ant1-17.310-17.318Pass ReportNo.:EED32O81190401Page 16 of 24 TestGraphs PSDNVNTBLE1M2402MHzAnt1 PSDNVNTBLE1M2440MHzAnt1 ReportNo.:EED32O81190401Page 17 of 24 PSDNVNTBLE1M2480MHzAnt1 ReportNo.:EED32O81190401Page 18 of 24 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-38.54-20Pass NVNTBLE1M2480Ant1-34.8-20Pass ReportNo.:EED32O81190401Page 19 of 24 TestGraphs BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32O81190401Page 20 of 24 BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:EED32O81190401Page 21 of 24 ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-40.58-20Pass NVNTBLE1M2440Ant1-39.04-20Pass NVNTBLE1M2480Ant1-36.5-20Pass ReportNo.:EED32O81190401Page 22 of 24 TestGraphs Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:EED32O81190401Page 23 of 24 Tx.SpuriousNVNTBLE1M2440MHzAnt1Ref Tx.SpuriousNVNTBLE1M2440MHzAnt1Emission ReportNo.:EED32O81190401Page 24 of 24 Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ***ENDOFREPORT***

Test Setup Photos

ReportNo.:EED32O81190401Page 28 of 39 9PHOTOGRAPHSOFTESTSETUP TestmodelNo.:FR1DQ1-B RadiatedspuriousemissionTestSetup-1 (Below1GHz) RadiatedspuriousemissionTestSetup-2 (Below1GHz)closeupphoto ReportNo.:EED32O81190401Page 29 of 39 RadiatedspuriousemissionTestSetup-3( Above1GHz) RadiatedspuriousemissionTestSetup-4( Above1GHz) Thereareabsorbingmaterialsundertheground.

Contact Information

Applicant

Jimmy Deng(Regulatory Manager)
[email protected]886-2-87971288Fax: 886-2-87971282

Test Firm

Centre Testing International Group Co., LtdVicky Zhou
[email protected]N/A

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.30 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Microlife Corporation

U7I-EBPHKW2-D

Digital Non-invasive Blood Pressure and Electrocardiogram Monitor

Jul 03, 2026

Equipment Class

DTS - Digital Transmission System
U7I-BP3KV1-5W-2

Blood Pressure Monitor

Jan 16, 2026

Equipment Class

DTS - Digital Transmission System
Digital Blood Pressure Monitor - FCC ID U7I-BP3T01-1B - Microlife Corporation
U7I-BP3T01-1B

Digital Blood Pressure Monitor

Jul 17, 2024

Equipment Class

DTS - Digital Transmission System
Peak flow meter - FCC ID U7I-PF200B - Microlife Corporation
U7I-PF200B

Peak flow meter

Aug 31, 2023

Equipment Class

DTS - Digital Transmission System
Digital Blood Pressure Monitor - FCC ID U7I-BP3MX1-1C - Microlife Corporation
U7I-BP3MX1-1C

Digital Blood Pressure Monitor

Jul 30, 2023

Equipment Class

DTS - Digital Transmission System