FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GS Instech Co., Ltd./
  3. U88-SMR-IP10-D

U88-SMR-IP10-DIn-Building RF Repeater

GS Instech Co., Ltd.
In-Building RF Repeater - FCC ID U88-SMR-IP10-D - GS Instech Co., Ltd.
Click to zoom

Application Details

Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Date of Grant
May 12, 2015
Application Purpose
Original Equipment
Date of Application
May 12, 2015
Equipment Note
In-Building RF Repeater
Frequency Range
1850.00000000 - 1915.00000000
Company
GS Instech Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Technicians Installation & Operation Guide Model: SMR -IP10-D SMR -IP10-S Version 1.0 GS Teletech Inc. Confidential and proprietary to GS Teletech Inc.Copying, reproduction or distribution this informat ion is strictly prohibited without prior written authorization from GST. SMR -IP10 -D/ -S  Smart Mobile Repeater for 800MHz and 1900MHz Bands  Application: Small Business, Enterprise and Public venues.  Coverage: Up to 5k sq. ft. per unit. SMR -IP10 2 Technician’s Installation & Operation Guide This publication provides instructions for installing the 800MHz and 1900MHz Smart Mobile Repeater. The images for the User Interface in this publication may vary depending on it’s S/W version. Copyright© 2015, GS Teletech, Inc. All Rights ReservedPrinted in the Republic of KoreaVersion History:CertificationUL/FCC: This equipment complies with UL and FCC Date Version Changes 04/2015 1.0 SMR -IP10 3 Technician’s Installation & Operation Guide WARNING! EXPOSURE TO RFWorking with the repeater while in operation, may e xpose the technician to RF electromagnetic fields that exceed FCC rules for human exposure. Visit the FCC website at http://www.fcc.gov/oet/rfsafety to learn more about the effects of exposure to RF e lectromagnetic fields. WARNING! ELECTRIC SHOCKOpening the BDA (bi-directional amplifier) could re sult in electric shock and may cause severe injury. WARNING! DAMAGE TO EQUIPMENTOperating the BDA with antennas in very close proxi mity facing each other could lead to severe damage to the repeater.RF EXPOSURE & ANTENNA PLACEMENTActual separation distance is determined upon gain of antenna used. Please maintain a minimum safe distance of at least 8 inch while operating near the donor and the serve r antennas. Also, the donor antenna needs to be mounted outdoors on a permanent structure. WARRANTYOpening or tampering the BDA will void all warranti es. CAUTION: REPEATER SHOULD BE INSTALLED AS CLOSE AS P OSSIBLE TO POWER SOURCE. CAUTION: THIS REPEATER IS FOR INDOOR USE ONLY AND S HOULD BE LOCATED INSIDE OF BUILDING. CAUTION: RISK OF EXPLOSION IF BATTERY ON CONTROLLER BOARD IS REPLACED WITH AN INCORRECT TYPE. CAUTION: DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. Warnings and Hazards 4 Technician’s Installation & Operation Guide This equipment has been tested and found to comply with the limits for a Class B digital device, pursu ant to part 15 of the FCC Rules. These limits are designed to provide reasonable pro tection against harmful interference in a residenti al installation. This equipment generates, uses and can radiate radio frequency ene rgy and, if not installed and used in accordance wi th the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference w ill not occur in a particular installation. If this equipment does cau se harmful interference to radio or television rece ption, which can be determined by turning the equipment off and on, the user is en couraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connec ted. - Consult the dealer or an experienced radio/TV tech nician for help. FCC Part 15.21 statementAny changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.RF Exposure StatementThe antenna(s) must be installed such that a minimu m separation distance of at least 20 cm is maintained between the radiator (antenna) and all p ersons at all times. This device must not be co-loc ated or operating in conjunction with any other antenna or transmitter.Part 90.635 requirement Antennas must be installed in accordance with FCC 9 0.635. With 9 dBi gain antennas the height of the an tenna above average terrain (HAAT) is permitted over 1372m. For differe nt gain antennas refer to the relevant rules. Warnings and Hazards 5 Technician’s Installation & Operation Guide WARNING. This is NOT a CONSUMER device. It is desig ned for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeitu re penalties, including penalties in excess of $100 ,000 for each continuing violation. Link CableJumper AC Cord DAU Bracket Set AC/DC Adaptor Contents of Box (1/2) 6 Technician’s Installation & Operation Guide SAU Bracket Set DAU SAU No Item Q-ty Picture 1 Donor Antenna Unit(DAU) 1 2 Service Antenna Unit(SAU) 1 3 Link cable (1.5D) 50m 1 4 AC/DC Adaptor 1 5 AC Power Cord 1 6 Quick Installation Guide 1 No Item Q-ty Picture 7 Operation and Troubleshooting Guide 1 8 DAU Bracket Set 1 • Tapping screw (PH(+) Φ5X25) • Anchor bolt 4 9 SAU Bracket Set 1 •Tapping screw (PH(+) Φ5X25) 4 10 Jumper Cable for both 800MHz and 1900Mhz 1 Contents of Box (2/2) 7 Technician’s Installation & Operation Guide Donor Antenna Unit (DAU) Service Antenna Unit (SAU) Repeater Design 8 Technician’s Installation & Operation Guide SMR-IP10-D SMR-IP10-S DAU (SMR-IP10-D) Dimensions 9 Technician’s Installation & Operation Guide 209(W) X 190(H) X 74(D) [mm]8.2(W) X 7.4(H) X 2.9(D) [in] Repeater Design: Donor Antenna Unit (DAU) SAU (SMR-IP10-S) Dimensions 10 Technician’s Installation & Operation Guide 252(W) X 148(H) X 54(D) [mm]9.9(W) X 5.8(H) X 2.1(D) [in] Repeater Design: Service Antenna Unit (SAU) 800MHz & 1900MHz Frequency Bands 11 Technician’s Installation & Operation Guide Service Band Blocks 800MHz Band 1900MHz Band 817 824 869 862 A D B E F C G A D B E F C G 1850 1910 1915 1930 1990 1995 LTE 819 864 CDMA CDMA LTE  Built-in antennas in Donor Antenna Unit (DAU) and S ervice Antenna Unit (SAU).  Link Distance: 50m (from DAU to SAU) using RG174 (1 .5D) cable (Non-Flammable).  Electric DC power feeding from Ser…

Text truncated - open the document above for the full version.

Cover Letter(s)

GS Instruments Co., Ltd. Date: October 15, 2012 Compliance Certification Services Certification Division 561F Monterey Road Morgan Hill, CA 95037 To whom it may concern: We, the undersigned, hereby authorize < HCT CO., LTD.>, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by < HCT CO., LTD.> on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing < HCT CO., LTD.> as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Young-Il Kim, Assistant Manager GS Instruments Co., Ltd. REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us.

Cover Letter(s)

Request for Confidentiality Compliance Certification Services Date: Apr. 22, 2015 Fremont, CA 94538 RE: FCC ID: Certification Application U88-SMR-IP10-D Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: CONFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST ExhibitDescription CONFIDENTIAL 1 Block Diagram 2 Parts Lists and Tune-up Procedure 3 Schematics 4 Operational Description SHORT-TERM CONFIDENTIAL 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 User’s Manual We are also hereby req uest Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give GS Instruments Co., Ltd. temporary confidentiality of commercially sensitive information prior to product release. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457 & 0.459, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : GS Ins truments Co., Ltd. Young-Il Kim, Assistant Ma nager Address: 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200, Korea

ID Label/Location Info

GS Instruments Co., Ltd. 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200, Korea ____________________________________________________________________________ Date: Apr. 22, 2015 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 Subject: Letter for Warning Label Message FCC ID: U88-SMR-IP10-D To Whom It May Concern: Warning label messages will be also shown in online and point-of-sale marketing materials and on outside packaging of device per KDB 935210 D02 in Section IV clause (d). Best Regards Young-Il Kim, Manager GS Instruments Co., Ltd.

Internal Photos

FCC ID : U88-SMR-IP10-D INTERNAL PHOTOGRAPHS HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/ 8 FCC ID : U88-SMR-IP10-D HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/ 8 FCC ID : U88-SMR-IP10-D HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/ 8 FCC ID : U88-SMR-IP10-D HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/ 8 FCC ID : U88-SMR-IP10-D HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/ 8 FCC ID : U88-SMR-IP10-D HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/ 8 FCC ID : U88-SMR-IP10-D HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/ 8 FCC ID : U88-SMR-IP10-D HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 8/ 8

RF Exposure Info

FCC ID: U88-SMR-IP10-D RF EXPOSURE STATEMENT 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34....................................... 1.34 - 30....................................... 30 - 300....................................... 300 - 1500.................................... 1500 - 100.000................................. 614 824/f 27.5 ............... ............... 1.63 2.19/f 0.073 ............... ............... *(100) *(180/ f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz * = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna FCC ID: U88-SMR-IP10-D 2-1 Limit 2-1 -1 800 MHz BAND Max Average output Power at antenna input terminal 10.000 dBm Max Average output Power at antenna input terminal 10.000 mW Prediction distance 20.000 cm Prediction frequency 817.00 MHz Antenna Gain(typical) 7.000 dBi Antenna Gain(numeric) 5.0119 - Power density at prediction frequency( S) 0.00997 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.545 mW/cm 2 2-1 -2 1900 MHz BAND Max Average output Power at antenna input terminal 10.000 dBm Max Average output Power at antenna input terminal 10.000 mW Prediction distance 20.0000 cm Prediction frequency 1850.0000 MHz Antenna Gain(typical) 9.0000 dBi Antenna Gain(numeric) 7.94328 - Power density at prediction frequency( S) 0.015803 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 1.0000 mW/cm 2 2-1 -3 BT BAND Max Peak output Power at antenna input terminal 2.6600 dBm Max Peak output Power at antenna input terminal 1.845 mW Prediction distance 20.0000 cm Prediction frequency 2402.0000 MHz Antenna Gain(typical) 1.99000 dBi Antenna Gain(numeric) 1.58125 - Power density at prediction frequency( S) 0.000580 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 1.0000 mW/cm 2 FCC ID: U88-SMR-IP10-D 3. Multiple radio MPE Factor 1) 800MHz and BT ( 0.00997/0.545)+( 0.000580/1.0000) = 0.018294+ 0.00058 = 0.018874< 1.0 mW 2) 1900MHz and BT ( 0.015803/1.0000)+ ( 0.000580/1.0000) = 0.015803 + 0.00058 = 0.016383 < 1.0 mW  Therefore, the worst-case situation is 0.00997/0.545)+( 0.000580/1.0000) = 0.018874 which is less than “1” This confirmed that the device comply with fcc 1.1310 MPE Limit.

Test Report

Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 2 of 63 Version TEST REPORT NO. DATE DESCRIPTION HCT-R-1504-F029 April 24 , 2015 - First Approval Report F-01P-02-014 (Rev.00) FCC ID: U88-SMR-IP10-D HCT Co.,LTD. Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 3 of 63 Table of Contents 1. CLIENT INFORMATION ................................................................................................................................ 4 2. FACILITIES AND ACCREDITATIONS .......................................................................................................... 5 2.1. FACILITIES ......................................................................................................................................... 5 2.2. EQUIPMENT ....................................................................................................................................... 5 3. TEST SUMMARY .......................................................................................................................................... 6 3.1. STANDARDS ...................................................................................................................................... 6 3.2. MODE OF OPERATION DURING THE TEST .................................................................................... 7 4. STANDARDS ENVIRONMENTAL TEST CONDITIONS .............................................................................. 8 5. TEST EQUIPMENT ....................................................................................................................................... 9 6. RF OUTPUT POWER.................................................................................................................................. 10 7.OCCUPIED BANDWIDTH............................................................................................................................ 18 8. OUT OF BAND REJECTION ...................................................................................................................... 26 9. SPURIOUS AND HARMONIC EMISSION AT ANTENNA TERMINAL ...................................................... 29 10. RADIATED SPURIOUS EMISSIONS ....................................................................................................... 57 11. FREQUENCY STABILITY OVER TEMPERATURE AND VOLTAGE VARIATIONS ................................ 62 F-01P-02-014 (Rev.00) FCC ID: U88-SMR-IP10-D HCT Co.,LTD. Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 4 of 63 1. CLIENT INFORMATION The EUT has been tested by request of Company GS Instruments Co.,Ltd. 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200, Korea Contact Point Attention: Yung-Il Kim Tel./ Fax. : +82-32-870-5621/ +82-32-876-3495 ■ FCC ID: U88-SMR-IP10-D ■ APPLICANT: GS Instruments Co.,Ltd. ■ EUT Type: In-Building RF Repeater ■ Model: SMR-IP10-D ■ Frequency Ranges: 800 MHz: 1900 MHz: Uplink : 817 MHz ~ 824 MHz Uplink : 1 850 MHz ~ 1 915 MHz ■ Conducted Output Power: 0.01 W (10 dBm) ■ Antenna Gain(s) : 800 MHz: 7 dBi, 1900 MHz: 9 dBi ■ FCC Rules Part(s): CFR 47, Part 24, Part 90 ■ Measurement standard(s): ANSI/TIA-603-C-2004, KDB 971168 D01 v02r02, KDB 935210 D03 v02r01 ■ Place of Tests: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, Korea. F-01P-02-014 (Rev.00) FCC ID: U88-SMR-IP10-D HCT Co.,LTD. Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 5 of 63 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea. The site is constructed in conformance with the requirements of ANSI C63.4. (Version :2003) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated February 28, 2014 (Registration Number: 90661). 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of Linearly polarized antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre- selectors and quasi-peak detectors are used to perform radiated measurements. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring Apparatus and Measurement Methods.” F-01P-02-014 (Rev.00) FCC ID: U88-SMR-IP10-D HCT Co.,LTD. Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 6 of 63 3. TEST SUMMARY 3.1. STANDARDS The following tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC Part 24 , Part 90. Description Reference Results RF Output Power §2.1046, §90.635, §24.232 Compliant Occupied Bandwidth §2.1049 Compliant Out of Band Rejection KDB 935210 D03 v02r01 Compliant Spurious Emissions at Antenna Terminals §2.1051, §90.691, §24.238 Compliant Radiated Spurious Emissions §2.1053, §90.691, §24.238 Compliant Frequency Stability §2.1055, §90.213, §24.235 Compliant * Note The EUT was operated in a manner representative of the typical usage of the equipment. During all testing, system components were manipulated within the confines of typical usage to maximize each emission. F-01P-02-014 (Rev.00) FCC ID: U88-SMR-IP10-D HCT Co.,LTD. Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 7 of 63 3.2. MODE OF OPERATION DURING THE TEST SMR-IP10 consists of DAU (Donor Antenna Unit) and SAU (Service Antenna Unit) which are connected via RG174 cable. Both DAU and SAU have built-in antenna and amplifier. Downlink and Uplink signals in DAU are transmitted via 800/1900MHz Dual Built-in antenna from/toward Base Station. If 800MHz and 1900MHz BTS directions are different, installer may connect DAU to 800MHz external antenna for receiving and transmitting signals from 800MHz Base Station. SMR-IP10’s SAU has External Port which allows connecting external anten…

Text truncated - open the document above for the full version.

Test Report

Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 29 of 63 9. SPURIOUS AND HARMONIC EMISSION AT ANTENNA TERMINAL FCC Rules Test Requirement(s): § 2.1051 Measurements required: Spurious emissions at antenna terminals: The radio frequency voltage or powers generated within the equipment and appearing on a spurious frequency shall be checked at the equipment output terminals when properly loaded with a suitable artificial antenna. Curves or equivalent data shall show the magnitude of each harmonic and other spurious emission that can be detected when the equipment is operated under the conditions specified in § 2.1049 as appropriate. The magnitude of spurious emissions which are attenuated more than 20 dB below the permissible value need not be specified. § 24.238 Emission limitations for Broadband PCS equipment. The rules in this section govern the spectral characteristics of emissions in the Broadband Personal Communications Service. (a) Out of band emissions. The power of any emission outside of the authorized operating frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. (b) Measurement procedure. Compliance with these rules is based on the use of measurement instrumentation employing a resolution bandwidth of 1 MHz or greater. However, in the 1 MHz bands immediately outside and adjacent to the frequency block a resolution bandwidth of at least one percent of the emission bandwidth of the fundamental emission of the transmitter may be employed. A narrower resolution bandwidth is permitted in all cases to improve measurement accuracy provided the measured power is integrated over the full required measurement bandwidth ( i.e. 1 MHz or 1 percent of emission bandwidth, as specified). The emission bandwidth is defined as the width of the signal between two points, one below the carrier center frequency and one above the carrier center frequency, outside of which all emissions are attenuated at least 26 dB below the transmitter power. (c) Alternative out of band emission limit. Licensees in this service may establish an alternative out of band emission limit to be used at specified band edge(s) in specified geographical areas, in lieu of that set forth in this section, pursuant to a private contractual arrangement of all affected licensees and applicants. In this event, each party to such contract shall maintain a copy of the contract in their station files and disclose it to prospective assignees or transferees and, upon request, to the FCC. (d) Interference caused by out of band emissions. If any emission from a transmitter operating in this service results in interference to users of another radio service, the FCC may require a greater attenuation of that emission than specified in this section. Test Procedures: A modulated carrier generated by the signal generator carrier was connected to either the Uplink or Downlink RF port at a maximum level as determined by the spectrum analyzer was connected to either the Uplink or Downlink port depending on the circuitry being measured. F-01P-02-014 (Rev.00) FCC ID: U88-SMR-IP10-D HCT Co.,LTD. Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 30 of 63 The spectrum was investigated from 9 kHz to the 26.5 of the carrier. Test Results: The EUT complies with the requirements of this section. There were no Detectable Spurious emissions for this EUT. § 90.691 Emission mask requirements for EA-based systems. (a) Out-of-band emission requirement shall apply only to the “outer” channels included in an EA license and to spectrum adjacent to interior channels used by incumbent licensees. The emission limits are as follows: (1) For any frequency removed from the EA licensee's frequency block by up to and including 37.5 kHz, the power of any emission shall be attenuated below the transmitter power (P) in watts by at least 116 Log 10 (f/6.1) decibels or 50 + 10 Log 10 (P) decibels or 80 decibels, whichever is the lesser attenuation, where f is the frequency removed from the center of the outer channel in the block in kilohertz and where f is greater than 12.5 kHz. (2) For any frequency removed from the EA licensee's frequency block greater than 37.5 kHz, the power of any emission shall be attenuated below the transmitter power (P) in watts by at least 43 + 10Log 10 (P) decibels or 80 decibels, whichever is the lesser attenuation, where f is the frequency removed from the center of the outer channel in the block in kilohertz and where f is greater than 37.5 kHz. (b) When an emission outside of the authorized bandwidth causes harmful interference, the Commission may, at its discretion, require greater attenuation than specified in this section. * Note Test (a)-(1) was replaced by a band edge test. Test Procedures: A modulated carrier generated by the signal generator carrier was connected to either the Uplink or Downlink RF port at a maximum level as determined by the spectrum analyzer was connected to either the Uplink or Downlink port depending on the circuitry being measured. The spectrum was investigated from 9 kHz to the 26.5 GHz of the carrier. Test Results: Input Signal Input Level (dBm) Maximum Amp Gain CDMA CDMA EVDO LTE 5 MHz LTE + CMDA UL : -65 dBm 75 dB F-01P-02-014 (Rev.00) FCC ID: U88-SMR-IP10-D HCT Co.,LTD. Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 31 of 63 1900 MHz band Conducted Spurious Emissions 9 kHz ~ 150 kHz Frequency (MHz) Spurious emission (dBm) Limit (dBm) CDMA 1851.25 -56.15 -13.00 1882.50 -54.73 -13.00 1913.75 -54.29 -13.00 CDMA EVDO 1851.25 -54.50 -13.00 1882.50 -55.85 -13.00 1913.75 -56.47 -13.00 LTE 5 MHz 1852.50 -54.32 -13.00 1882.50 -54.63 -13.00 1912.50 -55.80 -13.00 F-01P-02-014 (Rev.00) FCC ID: U88-SMR-IP10-D HCT Co.,LTD. Report No.: HCT-R-1504-F029 Model: SMR-IP10-D Page 32 of 63 Plots of Spurious Emission 1900 MHz band CDMA Conducted Spurious Emissions (9 kHz – 150 kHz) ▣ TEST Plot for 1900 MHz band CDMA 1900 MHz band (9 kHz – 150 kHz) CDMA Low 1900 MHz band …

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID : U88-SMR-IP10-D TEST SETUP PHOTOGRAPHS HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/ 6 FCC ID : U88-SMR-IP10-D ■ Conducted Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/ 6 FCC ID : U88-SMR-IP10-D ■ Conducted Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/ 6 FCC ID : U88-SMR-IP10-D ■ Radiated Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/ 6 FCC ID : U88-SMR-IP10-D ■ Radiated Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/ 6 FCC ID : U88-SMR-IP10-D ■ Radiated Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/ 6

Contact Information

Applicant

Guanyong Jung
[email protected]+82328705525Fax: +82328705640

Technical Contact

HCT Co., LTDSunHee Kim
[email protected]82-31-645-6451

74, Seoicheon-ro 578beon-gil, Majang-myeon, · New Taipei city · South Korea

Non-Technical Contact

HCT Co., LTDSunHee Kim
[email protected]82-31-645-6451

Test Firm

HCT Co., LTDSang Lee
[email protected]82-31-645-6420Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
424E1.85 GHz - 1.92 GHz10.00 mWG7DAmp
Confidentiality
Long Term
Grant Notes
Booster. Power output listed is conducted. Devices supporting CDMA, EVDO, and LTE will be the intended use. This device is part of a booster system operated with FCC ID U88-SMR-IP10-S. RF Exposure compliance for the device was based on maximum antenna gain 7 dBi for 800 MHz and 9 dBi for 1900 MHz. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements for satisfying RF exposure compliance. RF exposure compliance may need to be addressed at the time of licensing as required by the responsible FCC Bureau(s), including antenna co-location requirements of &sect;1.1307(b) (3) of the rules.

Other Applications from GS Instech Co., Ltd.

Cell Phone Signal Booster - FCC ID U88-HOME7500 - GS Instech Co., Ltd.
U88-HOME7500

Cell Phone Signal Booster

Feb 09, 2020

Equipment Class

B2W - Part 20 Wideband Consumer Booster (CMRS)
In-Building RF Repeater - FCC ID U88-SMR-IP10-S - GS Instech Co., Ltd.
U88-SMR-IP10-S

In-Building RF Repeater

May 12, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
In-Building RF Repeater - FCC ID U88-SMT-I33 - GS Instech Co., Ltd.
U88-SMT-I33

In-Building RF Repeater

May 04, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
CDMA In-Building RF Repeater - FCC ID U88-SMT-C33 - GS Instech Co., Ltd.
U88-SMT-C33

CDMA In-Building RF Repeater

Nov 21, 2012

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
CDMA In-Building RF Repeater - FCC ID U88-SMT-A33 - GS Instech Co., Ltd.
U88-SMT-A33

CDMA In-Building RF Repeater

Nov 21, 2012

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter