Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Smart-Cell Repeater User Manual 33 dBm Febuary, 2015 Version 1.1 Verizon User Manual Smart-Cell Repeater 2 - INDEX - 1. INTRODUCTION .......................................................................................................................... 4 1.1. Warning .................................................................................................................................................................................... 4 1.1.1 FCC Warning Statements ....................................................................................................................................... 4 1.2. GST Smart-Cell Repeater Advantages ........................................................................................................................ 5 1.3. Repeater Operation ............................................................................................................................................................ 5 1.4. Abbreviation ........................................................................................................................................................................... 7 2. SYSTEM CONFIGURATION ........................................................................................................ 8 2.1. Smart-Cell Repeater Service Network Configuration ......................................................................................... 8 2.2. System Design and Operation ...................................................................................................................................... 9 2.2.1. System Design ............................................................................................................................................................ 9 2.2.2. Downlink/ Uplink Path ..........................................................................................................................................10 2.2.3. 700MHz Frequency Selection ............................................................................................................................11 2.2.4. 800MHz Frequency Selection ............................................................................................................................11 2.2.5. 850MHz Frequency Selection ............................................................................................................................12 2.2.6. 1900MHz Frequency Selection ..........................................................................................................................12 2.2.7. 2100MHz Frequency Selection ..........................................................................................................................13 3. SYSTEM SPECIFICATIONS ........................................................................................................ 14 3.1. RF Performance ..................................................................................................................................................................14 3.2. System Specifications.......................................................................................................................................................15 3.3. Electrical and Environmental Specifications ..........................................................................................................16 3.4. Functions ...............................................................................................................................................................................16 4. SETUP .......................................................................................................................................... 18 4.1. Equipment Needed for Repeater Setup .................................................................................................................18 4.1.1. Check points before turning on the Repeater ..........................................................................................18 4.1.2. Open for Service ......................................................................................................................................................19 4.1.3. Signal Strength LED Check .................................................................................................................................20 4.2. Setting up the Repeater .................................................................................................................................................21 Verizon User Manual Smart-Cell Repeater 3 4.2.1. Quick GUI/Configuration .....................................................................................................................................21 4.2.2. Quick Setup ................................................................................................................................................................21 4.3. Web UI Ranges Table.......................................................................................................................................................22 4.4. Troubleshooting..................................................................................................................................................................23 4.4.1. Simple Troubleshooting Method .....................................................................................................................23 4.4.2. Alarm Information ...................................................................................................................................................23 4.4.3. Troubleshooting Guide Related to RF............................................................................................................27 4.4.4. Troubleshooting Guide Related to NMS ......................................................................................................30 Verizon User Manual Smart-Cell R…
Text truncated - open the document above for the full version.
GS Instruments Co., Ltd. 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200, Korea ____________________________________________________________________________ Date: Mar. 27, 2015 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 Subject: Letter for Warning Label Message FCC ID: U88-SMT-I33 To Whom It May Concern: Warning label messages will be also shown in online and point-of-sale marketing materials and on outside packaging of device per KDB 935210 D02 in Section IV clause (d). Best Regards Young-Il Kim, Manager GS Instruments Co., Ltd.
GS Instruments Co., Ltd. Date: October 15, 2012 Compliance Certification Services Certification Division 561F Monterey Road Morgan Hill, CA 95037 To whom it may concern: We, the undersigned, hereby authorize < HCT CO., LTD.>, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by < HCT CO., LTD.> on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing < HCT CO., LTD.> as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Young-Il Kim, Assistant Manager GS Instruments Co., Ltd. REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us.
Request for Confidentiality Compliance Certification Services Date: Mar. 06, 2015 Fremont, CA 94538 RE: FCC ID: Certification Application U88-SMT-I33 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: CONFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST ExhibitDescription CONFIDENTIAL 1 Block Diagram 2 Parts Lists and Tune-up Procedure 3 Schematics 4 Operational Description SHORT-TERM CONFIDENTIAL 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 User’s Manual We ar e also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give GS Instruments Co., Ltd. temporary confidentiality of commercially sensitive information prior to product release. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457 & 0.459, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : GS Ins t ruments Co., Ltd. Young-Il Kim, Assi stant Manager Address: 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200, Korea
FCC ID : U88-SMT-I33 EXTERNAL PHOTOGRAPHS HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/ 13 FCC ID : U88-SMT-I33 (Front) HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/ 13 FCC ID : U88-SMT-I33 (Rear) HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/ 13 FCC ID : U88-SMT-I33 (Left) HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/ 13 FCC ID : U88-SMT-I33 (Right) HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/ 13 FCC ID : U88-SMT-I33 (Top Side) HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/ 13 FCC ID : U88-SMT-I33 (Bottom Side) HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/ 13 FCC ID : U88-SMT-I33 (System) HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 8/ 13 FCC ID : U88-SMT-I33 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 9/ 13 FCC ID : U88-SMT-I33 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 10/13 FCC ID : U88-SMT-I33 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 11/13 FCC ID : U88-SMT-I33 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 12/13 FCC ID : U88-SMT-I33 HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 13/13
FCC ID : U88-SMT-I33 INTERNAL PHOTOGRAPHS HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/ 4 FCC ID : U88-SMT-I33 D RV _ To p HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/ 4 FCC ID : U88-SMT-I33 DRV_Bottom HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/ 4 FCC ID : U88-SMT-I33 PMA HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/ 4
FCC ID: U88-SMT-I33 RF EXPOSURE STATEMENT 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34....................................... 1.34 - 30....................................... 30 - 300....................................... 300 - 1500.................................... 1500 - 100.000................................. 614 824/f 27.5 ............... ............... 1.63 2.19/f 0.073 ............... ............... *(100) *(180/ f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz * = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna FCC ID: U88-SMT-I33 2-1 Limit Max Average output Power at antenna input terminal 33.000 dBm Max Average output Power at antenna input terminal 1955.262 mW Prediction distance 130.000 cm Prediction frequency 806.000 MHz Antenna Gain(typical) 17.000 dBi Antenna Gain(numeric) 50.1 - Power density at prediction frequency( S) 0.47087 mW/cm 2 MPE limit for uncontrolled exposure at prediction frequency 0.537 mW/cm 2 3. RESULTS The power density level at 130 cm is 0.47087 mW/cm², which is below the uncontrolled exposure limit of 0.537 mW/cm² Note: “"RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances."
Report No.: HCT-R-1503-F010-1 Model: SMT-I33 Page 2 of 63 Version TEST REPORT NO. DATE DESCRIPTION HCT-R-1503-F010 March 16, 2015 - First Approval Report HCT-R-1503-F010-1 April 09, 2015 - Modify uplink frequency (1 page, 4 page) - Add test results table (31 page ~ 34 page) F-01P-02-014 (Rev.00) FCC ID: U88-SMT-I33 HCT Co.,LTD. Report No.: HCT-R-1503-F010-1 Model: SMT-I33 Page 3 of 63 Table of Contents 1. CLIENT INFORMATION ................................................................................................................................ 4 2. FACILITIES AND ACCREDITATIONS .......................................................................................................... 5 2.1. FACILITIES ......................................................................................................................................... 5 2.2. EQUIPMENT ....................................................................................................................................... 5 3. TEST SUMMARY .......................................................................................................................................... 6 3.1. STANDARDS ...................................................................................................................................... 6 3.2. MODE OF OPERATION DURING THE TEST .................................................................................... 6 4. STANDARDS ENVIRONMENTAL TEST CONDITIONS .............................................................................. 7 5. TEST EQUIPMENT ....................................................................................................................................... 8 6. RF OUTPUT POWER.................................................................................................................................... 9 7. OCCUPIED BANDWIDTH........................................................................................................................... 16 8. OUT OF BAND REJECTION ...................................................................................................................... 27 9. SPURIOUS AND HARMONIC EMISSION AT ANTENNA TERMINAL ...................................................... 30 10. RADIATED SPURIOUS EMISSIONS ....................................................................................................... 59 11. FREQUENCY STABILITY OVER TEMPERATURE AND VOLTAGE VARIATIONS ................................ 62 F-01P-02-014 (Rev.00) FCC ID: U88-SMT-I33 HCT Co.,LTD. Report No.: HCT-R-1503-F010-1 Model: SMT-I33 Page 4 of 63 1. CLIENT INFORMATION The EUT has been tested by request of Company GS Instruments Co.,Ltd. 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200, Korea Contact Point Attention: Ko Sung Moo Tel./ Fax. : +82-32-870-5566/ +82-32-870-5640 ■ FCC ID: U88-SMT-I33 ■ APPLICANT: GS Instruments Co.,Ltd. ■ EUT Type: In-Building RF Repeater ■ Model: SMT-I33 ■ Frequency Ranges: SMT800: Downlink : 862 MHz ~ 869 MHz Uplink : 817 MHz ~ 824 MHz ■ Conducted Output Power: 2 W (33 dBm) ■ Antenna Gain(s) : Manufacturer does not provide an antenna. ■ FCC Rules Part(s): CFR 47, Part90 ■ Measurement standard(s): ANSI/TIA-603-C-2004, KDB 971168 D01 v02r02, KDB 935210 D03 v02r01 ■ Place of Tests: 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi- do, Korea. (IC Recognition No. : 5944A-3) F-01P-02-014 (Rev.00) FCC ID: U88-SMT-I33 HCT Co.,LTD. Report No.: HCT-R-1503-F010-1 Model: SMT-I33 Page 5 of 63 2. FACILITIES AND ACCREDITATIONS 2.1. FACILITIES The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea. The site is constructed in conformance with the requirements of ANSI C63.4. (Version :2003) and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated February 28, 2014 (Registration Number: 90661). 2.2. EQUIPMENT Radiated emissions are measured with one or more of the following types of Linearly polarized antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with pre- selectors and quasi-peak detectors are used to perform radiated measurements. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring Apparatus and Measurement Methods.” F-01P-02-014 (Rev.00) FCC ID: U88-SMT-I33 HCT Co.,LTD. Report No.: HCT-R-1503-F010-1 Model: SMT-I33 Page 6 of 63 3. TEST SUMMARY 3.1. STANDARDS The following tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC Part90. Description Reference Results RF Output Power §2.1046, §90.635 Compliant Occupied Bandwidth §2.1049 Compliant Out of Band Rejection KDB 935210 D03 v02r01 Compliant Spurious Emissions at Antenna Terminals §2.1051, §90.691 Compliant Radiated Spurious Emissions §2.1053, §90.691 Compliant Frequency Stability §2.1055, §90.213 Compliant 3.2. MODE OF OPERATION DURING THE TEST The EUT was operated in a manner representative of the typical usage of the equipment. During all testing, system components were manipulated within the confines of typical usage to maximize each emission. The device does not supply antenna(s) with the system, so the dummy loads were connected to the RF output ports for radiated spurious emission testing. F-01P-02-014 (Rev.00) FCC ID: U88-SMT-I33 HCT Co.,LTD. Report No.: HCT-R-1503-F010-1 Model: SMT-I33 Page 7 of 63 4. STANDARDS ENVIRONMENTAL TEST CONDITIONS Temperature : + 15 °C to + 35 °C Relative humidity: 30 % to 60 % Air pressure 860 mbar to 1 060 mbar F-01P-02-014 (Rev.00) FCC ID: U88-SMT-I33 HCT Co.,LTD. Report No.: HCT-R-1503-F010-1 Model: SMT-I33 Page 8 of 63 5. TEST EQUIPMENT Manufacturer Model / Equipment Cal Interva…
Text truncated - open the document above for the full version.
FCC ID : U88-SMT-I33 TEST SETUP PHOTOGRAPHS HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/ 7 FCC ID : U88-SMT-I33 ■ Conducted Downlink-1 Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/ 7 FCC ID : U88-SMT-I33 ■ Conducted Downlink-2 Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/ 7 FCC ID : U88-SMT-I33 ■ Conducted Uplink-1 Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/ 7 FCC ID : U88-SMT-I33 ■ Conducted Uplink-2 Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/ 7 FCC ID : U88-SMT-I33 ■ Radiated Downlink Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/ 7 FCC ID : U88-SMT-I33 ■ Radiated Uplink Test Setup Photo HCT CO., LTD. 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si, Gyeonggi-do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/ 7
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 4 | 90S | 817 MHz - 824 MHz | 1.997 W | G7D | Amp |

Cell Phone Signal Booster
Equipment Class
B2W - Part 20 Wideband Consumer Booster (CMRS)
In-Building RF Repeater
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
In-Building RF Repeater
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
CDMA In-Building RF Repeater
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
CDMA In-Building RF Repeater
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter