FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GS Instech Co., Ltd./
  3. U88-SMT-C33

U88-SMT-C33CDMA In-Building RF Repeater

GS Instech Co., Ltd.
CDMA In-Building RF Repeater - FCC ID U88-SMT-C33 - GS Instech Co., Ltd.
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Nov 21, 2012
Application Purpose
Original Equipment
Date of Application
Nov 20, 2012
Equipment Note
CDMA In-Building RF Repeater
Frequency Range
824.00000000 - 849.00000000
Company
GS Instech Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SmartCell Repeater User Manual 33 dBm July, 2012 Version 1.0 User Manual SmartCell Repeater 2 - INDEX - 1. INTRODUCTION ............................................................................................................. 3 1.1 GST SmartCell Repeater Advantages ........................................................................... 5 1.2 Abbreviation ................................................................................................................. 5 2. SYSTEM CONFIGURATION ............................................................................................. 7 2.1 SmartCell Repeater Service Network Configuration .................................................... 7 2.2 System Design and Operation ...................................................................................... 8 2.2.1 System Design ....................................................................................................... 8 2.2.2 Downlink/ Uplink Path ........................................................................................ 10 2.2.3 700MHz Frequency Selection .............................................................................. 11 2.2.4 850MHz Frequency Selection .............................................................................. 11 2.2.5 1900MHz Frequency Selection ............................................................................ 12 2.2.6 2100MHz Frequency Selection ............................................................................ 13 3. SETUP ........................................................................................................................... 14 3.1 Equipment Needed for Repeater Setup ...................................................................... 14 3.1.1 Check points before turning on the Repeater ...................................................... 14 3.1.2 Ready for Service ................................................................................................. 15 3.1.3 Signal Strength LED Check .................................................................................. 15 3.2 Setting up the Repeater ............................................................................................. 15 3.2.1 Quick GUI/Configuration ..................................................................................... 16 3.2.2 Quick Setup ......................................................................................................... 16 3.3 WebUI Ranges Table .................................................................................................. 16 3.4 Troubleshooting ......................................................................................................... 17 3.4.1 Simple Troubleshooting Method .......................................................................... 17 3.4.2 Alarm Information ............................................................................................... 17 3.4.3 Troubleshooting Guide Related to RF .................................................................. 20 3.4.4 Troub leshooting Guide Related to NMS ............................................................... 22 User Manual SmartCell Repeater 3 U.S.A. U.S.FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT INFORMATION TO THE USER NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular Installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encourage to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet of a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for assistance. Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Connecting of peripherals requires the use of grounded shielded signal cables. User Manual SmartCell Repeater 4 IC Warning This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. User Manual SmartCell Repeater 5 1. INTRODUCTION SmartCell is a modular repeate…

Text truncated - open the document above for the full version.

Cover Letter(s)

GS Instruments Co., Ltd. Date: October 15, 2012 Compliance Certification Services Certification Division 561F Monterey Road Morgan Hill, CA 95037 To whom it may concern: We, the undersigned, hereby authorize < HCT CO., LTD.>, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by < HCT CO., LTD.> on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing < HCT CO., LTD.> as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Young-Il Kim, Assistant Manager GS Instruments Co., Ltd. REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us.

Cover Letter(s)

Request for Confidentiality Compliance Certification Services Date:October 15, 2012 Fremont, CA 94538 RE: Certification Application FCC ID: U88-SMT- C3 3 Confid entialit y Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: CONFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description CONFIDENTIAL 1 Block Diagram 2 Parts Lists and Tune-up Procedure 3 Schematics 4 Operational Description SHORT-TERM CONFIDENTIAL 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 User’s Manual We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give GS Instruments Co., Ltd. temporary confidentiality of commercially sensitive information prior to product release. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457 & 0.459, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : GS Instruments Co., Ltd. Young-Il Kim, Assistant Manager Address: 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200, Korea

External Photos

FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/7 - EXTERNAL PHOTOS - FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/7 FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/7 FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/7 FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/7 FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/7 FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/7

ID Label/Location Info

FCC ID : U88-STM-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/2 1.1 ID Label Information Following is a copy of the label that will be placed on the rear side of the cabinet. Both the FCC ID and compliance statement are included in the product label Figure 1.1 PRODUCT LABEL Model Name : SMT-C33 FCC ID : U88-SMT-C33 IC : 8137A-SMTC33 EUT Type : CDMA In-Building RF Repeater Serial No : This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference , and (2) this device must accept any interference received, Including interference that may cause undesired operation. GS Instruments Co.,Ltd. 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200 South Korea MADE IN KOREA FCC ID : U88-STM-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/2 1.2 Label Location Photos Figure 1.2 LABEL LOCATION LABEL LOCATION

Internal Photos

FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/10 - INTERNAL PHOTOS - FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/10 Back Board FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 3/10 DFM FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 4/10 HPA FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 5/10 LED FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 6/10 FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 7/10 SNMP FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 8/10 FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 9/10 FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 10/10

Test Report

FCC PT.22 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1210FR14-1 Date of Issue: October 11, 2012 EUT Type: CDMA In-Building RF Repeater FCC ID: U88-SMT-C33 IC: 8137A-SMT-C33 Page 2 of 47 Revision TEST REPORT NO. DATE DESCRIPTION HCTR1210FR14 October 11, 2012 First Approval Report HCTR1210FR14-1 November 12, 2012 Some comments for KDB935210 were added. FCC PT.22 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1210FR14-1 Date of Issue: October 11, 2012 EUT Type: CDMA In-Building RF Repeater FCC ID: U88-SMT-C33 IC: 8137A-SMT-C33 Page 3 of 47 CONTENTS 1. CLIENT INFORMATION ............................................................................................................................................ 4 2. TEST SPECIFICATIONS ........................................................................................................................................... 5 3. STANDARDS ENVIRONMENTAL TEST CONDITIONS ...................................................................................... 5 4. TEST EQUIPMENT ..................................................................................................................................................... 6 5. RF OUTPUT POWER ................................................................................................................................................. 7 6. OCCUPIED BANDWIDTH ....................................................................................................................................... 16 7. SPURIOUS AND HARMONIC EMISSION AT ANTENNA TERMINAL ........................................................... 27 8. FIELD STRENGTH OF SPURIOUS RADIATION ................................................................................................ 40 9. FREQUENCY STABILITY OVER TEMPERATURE AND VOLTAGE VARIATIONS ...................................... 43 10. RF EXPOSURE STATEMENT .............................................................................................................................. 46 FCC PT.22 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1210FR14-1 Date of Issue: October 11, 2012 EUT Type: CDMA In-Building RF Repeater FCC ID: U88-SMT-C33 IC: 8137A-SMT-C33 Page 4 of 47 1. CLIENT INFORMATION The EUT has been tested by request of Company GS Instrumnets Co.,Ltd. 1385-14, Juan-Dong, Nam-Ku, Incheon, 402-200, Korea Contact Point Attention: Young Il Kim Tel. : +82-32-870-5545 ■ FCC ID: U88-SMT-C33 ■ APPLICANT: GS Instruments Co.,Ltd. ■ EUT Type: CDMA In-Building RF Repeater ■ Model: SMT-C33 ■Frequency Ranges: DL : 869 MHz ~ 894 MHz UL : 824 MHz ~ 849 MHz ■ Conducted Output Power: DL : 30.17 dBm UL : 30.10 dBm ■ Antenna Gain(s): DL : 2 dBi , UL : 9 dBi ■ FCC Rules Part(s): CFR Title 47 Part 22 ■ IC Rules Part(s): RSS-131, RSS-GEN ■ Place of Tests: 105-1, Jangam-ri , Majang-Myeon, Icheon-si, Gyeongggi-Do, 467-811, KOREA. (IC Recognition No. : 5944A-3) FCC PT.22 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1210FR14-1 Date of Issue: October 11, 2012 EUT Type: CDMA In-Building RF Repeater FCC ID: U88-SMT-C33 IC: 8137A-SMT-C33 Page 5 of 47 2. TEST SPECIFICATIONS Description Reference (FCC) Reference (IC) Results RF Power Output §2.1046; §22.913 RSS-131, Section 6.2 Compliant Occupied Bandwidth Passband Gain §2.1049 RSS-131, Section 6.1 RSS-GEN, Section 4.6.1 Compliant Spurious Emissions at Antenna Terminals §2.1053, §22.917 RSS-131, Section 6.3 RSS-131, Section 6.4 Compliant Frequency Stability §2.1055 RSS-131, Section 6.5 Compliant ※ We refered to KDB935210 to test the EUT. ※ According to KDB935210, for spurious emissions and bandwidth both maximum input at the highest gain setting (-57dBm input, 90dB gain) and maximum input level (-27dBm) is checked and the worst case (-57dBm/90dB gain) of the two is contained in the test report 3. STANDARDS ENVIRONMENTAL TEST CONDITIONS Temperature : + 15 °C to + 35 °C Relative humidity: 30 % to 60 % Air pressure 860 mbar to 1 060 mbar FCC PT.22 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1210FR14-1 Date of Issue: October 11, 2012 EUT Type: CDMA In-Building RF Repeater FCC ID: U88-SMT-C33 IC: 8137A-SMT-C33 Page 6 of 47 4. TEST EQUIPMENT Manufacturer Model / Equipment Serial No. Calibration Due Schwarzbeck BBHA 9120D / Double Ridged Horn Antenna 147 05/15/2014 Schwarzbeck BBHA 9120D / Double Ridged Horn Antenna 937 10/17/2013 Schwarzbeck VULB 9168 / TRILOG Antenna 9168-200 02/19/2013 HD MA240 / Antenna Position Tower 556 N/A EMCO 1050 / Turn Table 114 N/A HD GmbH HD 100 / Controller 13 N/A HD GmbH KMS 560 / SlideBar 12 N/A MITEQ AMF-6B-180265-35-10P / POWER AMP 667624 04/16/2013 Agilent N9020A /Signal Analyzer US46220219 05/02/2013 Agilent 6674A / DC Power Supply 3501A00901 05/02/2013 WEINSCHEL 67-30-33 / Attenuator BU5347 11/07/2012 WEINSCHEL AF9003-69-31 / Attenuator 5701 11/07/2012 Nang-Yeoul NY-THR18750 / Temperature Chamber NY-2009012201A 11/08/2012 FCC PT.22 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1210FR14-1 Date of Issue: October 11, 2012 EUT Type: CDMA In-Building RF Repeater FCC ID: U88-SMT-C33 IC: 8137A-SMT-C33 Page 7 of 47 5. RF OUTPUT POWER Test Requirements: § 2.1046 Measurements required: RF power output: § 2.1046 (a) For transmitters other than single sideband, independent sideband and controlled carrier radiotelephone, power output shall be measured at the RF output terminals when the transmitter is adjusted in accordance with the tune-up procedure to give the values of current and voltage on the circuit elements specified in § 2.1033(c)(8).The electrical characteristics of the radio frequency load attached to the output terminals when this test is made shall be stated. § 2.1046 (b) For single sideband, independent sideband, and single channel, controlled carrier radiotelephone transmitters, the procedure specified in paragraph (a) of this section shall be employed and, in additi…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 1/2 - SETUP PHOTO - FCC ID : U88-SMT-C33 / IC: 8137A-SMTC33 HCT CO., LTD. 105-1, JANGAM-RI, MAJANG-MYEON, ICHEON-SI, KYUNGGI-DO,KOREA TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr 2/2

Contact Information

Applicant

Guanyong Jung
[email protected]+82328705525Fax: +82328705640

Technical Contact

HCT CO., LTDEun Mi Kim
[email protected]+82-31-645-6469

105-1, Jangam-ri, Majang-Myeon, Icheon-si · Kyunggi-Do · South Korea

Test Firm

HCT Co., LTDSang Lee
[email protected]82-31-645-6420Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
222824 MHz - 849 MHz2.04 WF9W0.0005 ppm
Confidentiality
Long Term
Grant Notes
RF Cellular Repeater. Power output is composite for multi-channel operation. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 50cm from all persons. In addition antennas used with this device may not exceed gain of 9dBi gain for up-link and 2dBi gain for down-link. End users must be provided with transmitter operation condition for satisfying RF exposure compliance.

Other Applications from GS Instech Co., Ltd.

Cell Phone Signal Booster - FCC ID U88-HOME7500 - GS Instech Co., Ltd.
U88-HOME7500

Cell Phone Signal Booster

Feb 09, 2020

Equipment Class

B2W - Part 20 Wideband Consumer Booster (CMRS)
In-Building RF Repeater - FCC ID U88-SMR-IP10-D - GS Instech Co., Ltd.
U88-SMR-IP10-D

In-Building RF Repeater

May 12, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
In-Building RF Repeater - FCC ID U88-SMR-IP10-S - GS Instech Co., Ltd.
U88-SMR-IP10-S

In-Building RF Repeater

May 12, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
In-Building RF Repeater - FCC ID U88-SMT-I33 - GS Instech Co., Ltd.
U88-SMT-I33

In-Building RF Repeater

May 04, 2015

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
CDMA In-Building RF Repeater - FCC ID U88-SMT-A33 - GS Instech Co., Ltd.
U88-SMT-A33

CDMA In-Building RF Repeater

Nov 21, 2012

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter