Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 Hearth & Home Technologies • IFT-RC150U User Manual • 2564-981 • 11/20 User Manual IFT-RC150 IFT-RC150 IntelliFire Touch Wireless Wall Switch Model: 2564-100 Introduction The IFT-RC150 is a wall-mounted wireless wall switch that is designed to operate Hearth & Home Technologies appliances equipped with the IntelliFire Touch ® Technology. It has a temperature sensor and can be used to control the ON/OFF and cold-climate func- tion of your appliance as a stand-alone or in combi- nation with a Mobile App. This user manual serves as a quick reference to the wall switch operation. Operation Pairing • The IFT-RC150 must be paired to control the Elec- tronic Control Module (ECM). The pairing button is located underneath the top housing cover. • Remove IFT-RC150 top housing cover. Install 2 AA alkaline batteries. • The pairing button will activate the pairing mode of the wireless wall switch for 15 seconds while the LED indicator blinks once every second. • To pair the IFT-RC150 with the IFT ECM, press the pairing button on the ECM. When the ECM green LED starts blinking, press the pairing button on the IFT-RC150. If pairing is successful, the ECM will respond with a double beep and the green LED will stop blinking. Re-install the IFT-RC150 top housing cover. Flame ON/OFF • To turn the flame ON, press the top of the momentary toggle switch. • To turn the flame OFF, press the bottom of the momentary toggle switch. The appliance has a safety feature that automatically shuts down the appliance after 9 hours of continuous operation. Cold Climate This function turns on a continuous pilot and keeps the air inside the appliance warm while not in use. It is a useful feature in cold weather to minimize condensation on the appliance glass. • To turn the cold climate mode ON/OFF, press the small momentary push button below the momentary toggle switch. Note: This feature is disabled when a Power Vent is installed on the appliance. Note: The continuous pilot will automatically turn OFF after 166 hours if appliance is not actively used. If Flame ON is activated before 166 hours, the automatic timer will re-start. FIRMWAREFIRMWARE PROGRAMMINGPROGRAMMING ACCESS ACCESS Figure 1. IFT-RC150 No Top Cover Figure 1. IFT-RC150 Functions RED/GREEN LEDRED/GREEN LED COLD CLIMATE ON/OFFCOLD CLIMATE ON/OFF FLAME ONFLAME ON FLAME OFFFLAME OFF LEDLED COLD CLIMATECOLD CLIMATE CONTROL BUTTONCONTROL BUTTON PAIRING PAIRING BUTTON HOLE BUTTON HOLE AA AA BATTERYBATTERY HOLDERHOLDER ON/OFF ON/OFF SWITCHSWITCH 2 Hearth & Home Technologies • IFT-RC150U User Manual • 2564-981 • 11/20 CAUTION! Risk of burns! Appliance surfaces are hot when operating and during cool down. Use care and wear gloves when opening the front and accessing compo- nents inside the appliance. Turn off power to the appliance (if back-up batteries are not installed): • If the appliance comes equipped with a wired-wall switch, use that to turn it off. • Alternately, you can also locate the house circuit breaker for appliance and turn it off. • If the appliance is operating with back-up batteries and the batteries are accessible outside the fireplace, remove a battery to shutdown the appliance. Manual Fireplace Shutoff In the unlikely event that the wall switch malfunctions and will not turn off the fireplace, call your dealer for service assistance. In the meantime, turn off your appliance by performing the following actions: DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. IFT Wi-Fi Module (IFT-WFM) Reset If the IFT-ECM is equipped with the IFT-WFM, the IFT- RC150 can be used to reset the IFT-WFM to factory de- fault settings. To reset the IFT-WFM with the IFT-RC150, press and hold the top of the momentary toggle switch and the Cold Climate button for 2 seconds. The IFT-ECM will beep and reset the IFT-WFM. Note: Batteries should only be used as an appliance power source in the event of a power outage. Batteries should not be used as a primary long-term power source. Power Outage In the event of a power outage, the wireless wall switch can continue to operate the appliance if batteries are installed in the appliance’s battery backup system. Refer to the appliance owner’s manual for operation during a power outage. Power Requirements The IFT-RC150 is a battery-operated wireless control switch and requires 2 AA alkaline batteries. The operating voltage is 3VDC. Other battery types such as recharge- able NiMH or disposable Lithium AA batteries may be used to operate the wireless wall switch. LED Indicator • A single two-color LED indicator is located above the momentary toggle switch. The LED indicator identifies to the user the IFT-RC150 status. • GREEN: Blink during normal transmission. • RED: Blinks once every 5 seconds indicating Low Battery. • RED and GREEN: Blinks once every 5 seconds indi- cating of pairing. • It blinks every time it transmits a command. 3 Hearth & Home Technologies • IFT-RC150U User Manual • 2564-981 • 11/20 DANGER SymptomPossible CauseCorrective Action The appliance does not respond to commands from the wireless wall switch and the LED does not blink. Batteries are depleted.Verify batteries are new. Batteries are incorrectly installed. Verify batteries are installed in correct orientation as shown on the battery holder. The appliance does not respond to commands from the wireless wall switch but the LED blinks alternating RED and GREEN. The appliance does not respond to com- mands from the wireless wall switch, but the LED blinks when switch is touched. The wireless wall switch is not paired to or lost communication with the elec- tronic control module. Call dealer for service. The wall switch LED blinks even though no command is given. Communicating with electronic control module. This is normal o…
Text truncated - open the document above for the full version.
Hearth & Home Technologies Agent Authorization Company: Hearth & Home Technologies Address: 800 W. Jefferson Street, Lake, Minnesota 55041, United States Product Name: IFT-RC150 IntelliFire Touch Wireless Wall Switch Model Number(s): 2564-100 Product Description: IFT-RC150 IntelliFire Touch Wireless Wall Switch We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2020-06-12 Name: Davd C Lyons Title: VP R & D HHT Company: Hearth & Home Technologies
< Hearth & Home Technologies > Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD21046 Date: 2020-06-12 Subject; Request for Long Term Confidentiality FCC ID: ULE2564-100 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Davd C Lyons Title: VP R & D HHT
Test Model No.: 2564‐100
PN: 2564-100 39x6mm 30x15mm FCC ID: ULE2564-100 IC: 6732A-2564100 Hearth & Home Technologies PN: 2564-100 Frequency: 912.2~918MHz Made in China SN:YYWWHFMNNNN 0°C to +60°C FCC ID: ULE2564-100 IC: 6732A-2564100 Hearth & Home Technologies PN: 2564-100 Frequency: 912.2~918MHz Made in China SN:YYWWHFMNNNN 0°C to +60°C Size:paster
Test Model No.: 2564‐100
Global United Technology Services Co., Ltd. Report No.: GTS202006000080-01 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 28 Test Report FCC Applicant: Hearth & Home Technologies Address: 800 W. Jefferson Street, Lake, Minnesota 55041, United States IC Applicant: HEARTH & HOME TECHNOLOGIES Address: 800 W. Jefferson Street Lake City MN 55041United States Of America Manufacturer: Hearth & Home Technologies Address: 800 W. Jefferson Street, Lake, Minnesota 55041, United States Factory: Computime Electronics (Shenzhen) CO.,LTD Address: Computime Technology Pk,Dan Zhu Tou Cun Buji,Longgang Region Shenzhen China Equipment Under Test (EUT) Product Name: IFT-RC150 IntelliFire Touch Wireless Wall Switch Model No.: 2564-100 Trade Mark: Intellifire FCC ID: ULE2564-100 IC: 6732A-2564100 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.249 RSS-Gen Issue 5 RSS-210 Issue 10 Date of sample receipt: June 05, 2020 Date of Test: June 05-11, 2020 Date of report issued: June 11, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202006000080-01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 28 2 Version Version No. Date Description 00 June 11, 2020 Original Prepared By: Date: June 11, 2020 Project Engineer Check By: Date: June 11, 2020 Reviewer Report No.: GTS202006000080-01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 28 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 4.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 6 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 6 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 6 5.6 TEST FACILITY .................................................................................................................................... 6 5.7 TEST LOCATION ................................................................................................................................. 6 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 6 6 TEST INSTRUMENTS LIST ..................................................................................................................... 7 7 TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9 7.1 ANTENNA REQUIREMENT ..................................................................................................................... 9 7.2 RADIATED EMISSION METHOD ........................................................................................................... 10 7.2.1 Field Strength of The Fundamental Signal and spurious emissions ......................................... 13 7.2.2 Spurious emissions .................................................................................................................... 14 7.3 20DB OCCUPY BANDWIDTH AND 99% OCCUPIED BANDWIDTH ........................................................... 26 8 TEST SETUP PHOTO ............................................................................................................................ 28 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 28 Report No.: GTS202006000080-01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 28 4 Test Summary Test Item Section Result Antenna requirement 15.203 RSS-Gen Section 6.8 Pass AC Power Line Conducted Emission 15.207 RSS-Gen Section 8.8 N/A Field strength of the fundamental signal 15.249 (a) RSS-210 B10(a) Pass Spurious emissions 15.249 (a) (d)/15.209 RSS-Gen Clau…
Text truncated - open the document above for the full version.
Test Model No.: 2564‐100 Radiated Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 912.2 MHz - 918 MHz | - |

Electric Fireplace
Equipment Class
DTS - Digital Transmission System
IntelliFire Touch Technology -Electronic Control Module(IFT-ECM)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
IFT-RC400IntelliFire Touch Remote Control
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Fireplace system controller (ECM)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Fireplace system controller (Remote)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter