1 / 15 [GRAND MATE] Version: D05.0 at Dec 19 th , 2019 GM9K SERIES (INCLUDE GM9K1 / GM9K2 / GM9K3): GAS FIRED CONTROL SYSTEM USER MANUAL -FOR OEM USE ONLY FEATURES Fire or explosion hazard. Attempted disassembly or repair of controls can cause property damage, severe injury or death. Do not disassemble the gas valve; it contains no serviceable components. Read these instructions carefully. Failure to follow them could result in a fire or explosion causing property damage, personal injury, or loss of life. The product must be installed and operated according to all local regulations. A. BEFORE OPERATING verify that no gas is in the area around the appliance, including near the floor. WHAT TO DO IF YOU SMELL GAS: ■ Do not light any appliance. ■ Do not touch any electrical switch; do not use any phone in your building. ■ Immediately call the gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. ■ If you cannot reach the gas supplier, call the fire department. B. Use only your hand to push in or turn the gas control knobs. Never use tools. If a knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. C. Do not use this control or any gas appliance if any part has been under water or in contact with water. Immediately call a qualified service technician to replace the control system and any gas control system which has been under water or in contact with water. D. These instructions are to be referenced as a user guide, and do not supersede appliance manufac- turer’s lighting instructions. APPLICATION GM9K series is an electronic ignition control module for gas appliances with pilot burners, ODS systems, remote function, second burner and extra AC/DC output. Control module is a combination of control board and power board. GENERAL NOTES Multiple Remote Control Solutions: ■ GM9K1 for Unidirectional RF (434 MHz) ■ GM9K2 for Bidirectional RF (434 MHz) (Support RevoHome SYS.) ■ GM9K3 for Bluetooth This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Primary source(AC): An AC Main Adapter may be used instead of batteries. (AC source according to CSA and CE.) Secondary source(DC): ■ 4 x 1.5V “AA” Batteries. (quality alkaline recommended) ■ AC to DC 6.5V 1.5A adapter. NOTE: ■ Power board needed AC power to perform all functions, while AC power lost, power board function may lost simultaneously. ■ Electronic ignition control system ■ Ignition by supervised gas-fire pilot burner ■ Support pilot flame sensing: • Ionization flame detection • Thermpcouple flame detection ■ Max 9 hours idle auto shutdown ■ Manual control and Remote control ■ Flame height adjustment ■ Flexible combination of AC/DC output to control FAN, LIGHT, AUX ■ Second burner control ■ Thermostat function H13 2 / 15 GM9K SERIES (INCLUDE GM9K1 / GM9K2 / GM9K3) USER MANUAL - FOR OEM USE ONLY H13 [GRAND MATE] Version: D05.0 at Dec 19 th , 2019 SYSTEM WIRING DIAGRAM NOTE: “The pilot valve flame power must be limited to 250 Thermal Watt” This is mandatory to avoid the test to the pilot valve as safety relevant valve. AC to DC 6.5V Adapter Second Burn er Valve Wires Load 3 Load 2 Load 1 CON3 CON2 CON1 Appliance Grou nd Power in GM9K Series System W iring Dia gram for Flame Ionization Sensor Load s definition please see co mb inatio n diagram S Pilot I M ain Wires Batteries Pack (6V) Appliance Grou nd V1 V2 Stepper Moto r Gas Valve ON/OFF/R EMOTE SWITCH I O II AA/1 .5V AA/1 .5V AA/1 .5V AA/1 .5V External Learn Butto n V Second Burn er Valve Internal Learn Button LPG / NAT AC Power Cord V1 = Pilot Valve V2 = Main Valve Figure 1: GM9K Series system wiring diagram for ionization sensor External Learn Butto n Second Burn er Valve Wires Load 3 Load 2 Load 1 CON3 CON2 CON1 Appliance Grou nd Power in GM9K Series System Wiring Diagram for Thermocouple Sensor AC to DC 6.5V Ad apter Load s definition please see co mb inatio n diagram TC Module S I Pilot (Thermocouple, TC ) TC TC Module Wires Main Wires Batteries Pack (6V) Appliance Grou nd V1V2 Stepper Moto r Gas Valve ON/OFF/REMOTE SWITCH AA/1 .5V AA/1 .5V AA/1 .5V AA/1 .5V V Second Burn er Valve Internal Learn Button LPG / NAT AC Power Cord I O II Optional V1 = Pilot Valve V2 = Main Valve Figure 2: GM9K Series system wiring diagram for thermocouple sensor\ 3 / 15 GM9K SERIES (INCLUDE GM9K1 / GM9K2 / GM9K3) USER MANUAL - FOR OEM USE ONLY H13 [GRAND MATE] Version: D05.0 at Dec 19 th , 2019 ` CONTROL BOARD AND POWER BOARD CONNECTION DIAGRAM Connection of board to board(B to B) Bo ard to board wire Connection of wire to board(W to B) Figure 3: GM9K Series connection diagram of control board and power board 4 / 15 GM9K SERIES (INCLUDE GM9K1 / GM9K2 / GM9K3) USER MANUAL - FOR OEM USE ONLY H13 [GRAND MATE] Version: D05.0 at Dec 19 th , 2019 POWER BOARD COMBINATION DIAGRAM NOTE: Default AC output definitions of power board as below, all AC output load definitions could modified by firmware for variety applications. GM9KXX-A AC - FAN AC - LIGHT CON3 CON2 Power in GM9K Series Power Board Combination Diagram AC - FAN AC - LIGHT AC - AUX CON3 CON2 CON1 Power in GM9KXX-C DC - LIGHT (PWM*2) AC - FAN AC - AUX CON3 CON2 CON1 Power in GM9KXX-G AC FAN AC LIGHT N.A. Label AC FAN AC LIGHT AC AUX Label DC LIGHT AC FAN AC AUX Label DC - AUX (+/- 6 VDC) AC - FAN AC -LIGHT CON3 CON2 CON1 Power in GM9KXX-I DC AUX AC FAN AC LIGHT Label AC - FAN AC - AUX AC - LIGHT CON3 CON2 CON1 Power in GM9KXX-E AC FAN AC AUX AC LIGHT Label Figure 4: GM9K Series power board combination diagram 5 / 15 GM9K SERIES (INCLUDE GM9K1 / GM9K2 / GM9K3) USER MANUA…
Text truncated - open the document above for the full version.
Page 1 of 25 External Photos Model Number: GM9K2A-C-120VAC, GM9K2A-A-120VAC, GM9K2B-A-120VAC, GM9K2C-A-120VAC, GM9K2D-A-120VAC, GM9K2B-C-120VAC, GM9K2C-C-120VAC, GM9K2D-C-120VAC, GM9K2A-E-120VAC, GM9K2B-E-120VAC, GM9K2C-E-120VAC, GM9K2D-E-120VAC, GM9K2A-G-120VAC, GM9K2B-G-120VAC, GM9K2C-G-120VAC, GM9K2D-G-120VAC, GM9K2A-I-120VAC, GM9K2B-I-120VAC, GM9K2C-I-120VAC, GM9K2D-I-120VAC FCC ID: UMPGM9K2 Page 2 of 25 EUT Photo (1) EUT Photo (2) Page 3 of 25 EUT Photo (3) EUT Photo (4) Page 4 of 25 EUT Photo (5) EUT Photo (6) Page 5 of 25 EUT Photo (7) EUT Photo (8) Page 6 of 25 EUT Photo (9) EUT Photo (10) Page 7 of 25 EUT Photo (11) EUT Photo (12) Page 8 of 25 EUT Photo (13) EUT Photo (14) Page 9 of 25 EUT Photo (15) EUT Photo (16) Page 10 of 25 EUT Photo (17) EUT Photo (18) Page 11 of 25 EUT Photo (19) EUT Photo (20) Page 12 of 25 EUT Photo (21) EUT Photo (22) Page 13 of 25 EUT Photo (23) EUT Photo (24) Page 14 of 25 EUT Photo (25) EUT Photo (26) Page 15 of 25 EUT Photo (27) EUT Photo (28) Page 16 of 25 EUT Photo (29) EUT Photo (30) Page 17 of 25 EUT Photo (31) EUT Photo (32) Page 18 of 25 EUT Photo (33) EUT Photo (34) Page 19 of 25 EUT Photo (35) EUT Photo (36) Page 20 of 25 EUT Photo (37) EUT Photo (38) Page 21 of 25 EUT Photo (39) EUT Photo (40) Page 22 of 25 EUT Photo (41) EUT Photo (42) Page 23 of 25 EUT Photo (43) EUT Photo (44) Page 24 of 25 EUT Photo (45) EUT Photo (46) Page 25 of 25 EUT Photo (47) EUT Photo (48)
Page 1 of 18 Internal Photos Model Number: GM9K2A-C-120VAC, GM9K2A-A-120VAC, GM9K2B-A-120VAC, GM9K2C-A-120VAC, GM9K2D-A-120VAC, GM9K2B-C-120VAC, GM9K2C-C-120VAC, GM9K2D-C-120VAC, GM9K2A-E-120VAC, GM9K2B-E-120VAC, GM9K2C-E-120VAC, GM9K2D-E-120VAC, GM9K2A-G-120VAC, GM9K2B-G-120VAC, GM9K2C-G-120VAC, GM9K2D-G-120VAC, GM9K2A-I-120VAC, GM9K2B-I-120VAC, GM9K2C-I-120VAC, GM9K2D-I-120VAC FCC ID: UMPGM9K2 Page 2 of 18 EUT Photo (1) EUT Photo (2) Page 3 of 18 EUT Photo (3) EUT Photo (4) Page 4 of 18 EUT Photo (5) EUT Photo (6) ANT. Page 5 of 18 EUT Photo (7) EUT Photo (8) Page 6 of 18 EUT Photo (9) EUT Photo (10) Page 7 of 18 EUT Photo (11) EUT Photo (12) ANT. Page 8 of 18 EUT Photo (13) EUT Photo (14) Page 9 of 18 EUT Photo (15) EUT Photo (16) Page 10 of 18 EUT Photo (17) EUT Photo (18) Page 11 of 18 EUT Photo (19) EUT Photo (20) ANT. Page 12 of 18 EUT Photo (21) EUT Photo (22) Page 13 of 18 EUT Photo (23) EUT Photo (24) Page 14 of 18 EUT Photo (25) EUT Photo (26) ANT. Page 15 of 18 EUT Photo (27) EUT Photo (28) Page 16 of 18 EUT Photo (29) EUT Photo (30) Page 17 of 18 EUT Photo (31) EUT Photo (32) Page 18 of 18 EUT Photo (33) EUT Photo (34)
Note: 1.The test results are valid only for samples provided by customers and under the test conditions described in this report. 2.This report shall not be reproduced except in full, without the written approval of A Test Lab Technology Corporation. 3.The relevant information is provided by customers in this test report. According to the correctness, appropriateness or completeness of the information provided by the customer, if there is any doubt or error in the information which affects the validity of the test results, the laboratory does not take the responsibility. RF Test Report Applicant : Grand Mate Co., Ltd Product Type : Automatic Burner control Trade Name : GRAND MATE Model Number : GM9K2A-C-120VAC, GM9K2A-A-120VAC, GM9K2B-A-120VAC, GM9K2C-A-120VAC, GM9K2D-A-120VAC, GM9K2B-C-120VAC, GM9K2C-C-120VAC, GM9K2D-C-120VAC, GM9K2A-E-120VAC, GM9K2B-E-120VAC, GM9K2C-E-120VAC, GM9K2D-E-120VAC, GM9K2A-G-120VAC, GM9K2B-G-120VAC, GM9K2C-G-120VAC, GM9K2D-G-120VAC, GM9K2A-I-120VAC, GM9K2B-I-120VAC, GM9K2C-I-120VAC, GM9K2D-I-120VAC Applicable Standard : FCC 47 CFR PART 15 SUBPART C ANSI C63.10:2013 Received Date : Oct. 03, 2019 Test Period : Dec. 25, 2019 ~ Jan. 14, 2020 Issued Date : Mar. 13, 2020 Issued by A Test Lab Techno Corp. No. 140-1, Changan Street, Bade District, Taoyuan City 33465, Taiwan (R.O.C.) Tel:+886-3-2710188 / Fax:+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330 Test Firm MRA designation number: TW0010 Report Number: 2001FR17 Rev.02 Page 1 of 37 Revision History Rev. Issued Date Revisions Revised By 00 Feb. 05, 2020 Initial Issue Tobey Cheng 01 Feb. 19, 2020 Page 6 Add Serial Number. Page 10 Revised Test Instruments. Page 34 & 35 Revised test data. Nina Lin 02 Mar. 13, 2020 Page 7 Revised EUT Test Step. Nina Lin Report Number: 2001FR17 Rev.02 Page 2 of 37 Ve r i f i c a t i o n o f C o m p l i a n c e Issued Date: Mar. 13, 2020 Applicant : Grand Mate Co., Ltd Product Type : Automatic Burner control Trade Name : GRAND MATE Model Number : GM9K2A-C-120VAC, GM9K2A-A-120VAC, GM9K2B-A-120VAC, GM9K2C-A-120VAC, GM9K2D-A-120VAC, GM9K2B-C-120VAC, GM9K2C-C-120VAC, GM9K2D-C-120VAC, GM9K2A-E-120VAC, GM9K2B-E-120VAC, GM9K2C-E-120VAC, GM9K2D-E-120VAC, GM9K2A-G-120VAC, GM9K2B-G-120VAC, GM9K2C-G-120VAC, GM9K2D-G-120VAC, GM9K2A-I-120VAC, GM9K2B-I-120VAC, GM9K2C-I-120VAC, GM9K2D-I-120VAC FCC ID : UMPGM9K2 EUT Rated Voltage : AC 120 V/60 Hz Test Voltage : AC 120 V/60 Hz Applicable Standard : FCC 47 CFR PART 15 SUBPART C ANSI C63.10:2013 Test Result : Complied Performing Lab. : A Test Lab Techno Corp. No. 140-1, Changan Street, Bade District, Taoyuan City 33465, Taiwan (R.O.C.) Tel:+886-3-2710188 / Fax:+886-3-2710190 Taiwan Accreditation Foundation accreditation number: 1330http://www.atl-lab.com.tw/e-index.htm A Test Lab Techno Corp. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by A Test Lab Techno Corp. based on interpretations and/or observations of test results. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Approved By : (Manager) (Fly Lu) Report Number: 2001FR17 Rev.02 Page 3 of 37 TABLE OF CONTENTS 1 General Information ................................................................................................................... 5 1.1. Summary of Test Result .................................................................................................... 5 1.2. Measurement Uncertainty ................................................................................................. 5 2 EUT Description ......................................................................................................................... 6 3 Test Methodology ...................................................................................................................... 7 3.1. Mode of Operation ............................................................................................................ 7 3.2. EUT Test Step ................................................................................................................... 7 3.3. Configuration of Test System Details ................................................................................ 8 3.4. Test Instruments ............................................................................................................. 10 3.5. Test Site Environment ...................................................................................................... 11 4 Measurement Procedure ......................................................................................................... 12 4.1. AC Power Line Conducted Emission Measurement ........................................................ 12 4.2. Radiated Emissions Measurement ................................................................................. 14 4.3. 20 dB Bandwidth Measurement ...................................................................................... 18 4.4. Antenna Requirement ..................................................................................................... 19 5 Test Results .............................................................................................................................. 20 Annex A. Conducted Emission ................................................................................................... 20 Annex B. Conducted Test Results .............................................................................................. 29 Annex C. Radiated Emissions Measurement ............................................................................. 30 Report Number: 2001FR17 Rev.02 Page 4 of 37 1 General Information 1.1. Summary of Test Result Standard Item Results Remark 15.207 AC Power Conducted Emission PASS ---- 15.231(a) Transmitter Deactivation Time PASS ---- 15…
Text truncated - open the document above for the full version.
Test Setup Photographs Conducted Emissions Test Configuration: Front View Rear View Report Number: 2001FR17 Rev.01 Page 1 of 3 Radiated Emissions Test Configuration: Below 1 GHz _ Front View Below 1 GHz _ Rear View Report Number: 2001FR17 Rev.01 Page 2 of 3 Above 1 GHz _ Front View Above 1 GHz _ Rear View Report Number: 2001FR17 Rev.01 Page 3 of 3
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 434 MHz - 434 MHz | - |

Remote controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Automatic Burner control
Equipment Class
DTS - Digital Transmission System
TX-01 Remote controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter