Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Thank you for purchasing a Skyhawk device For instructions on how to get started, or to read the full user manual, scan the QR code below with your mobile phone or visit www.skyhawk.ai/get-started. On this site you’ll also find support for the Skyhawk devices your accessories work with, and download links to the Skyhawk mobile apps which control those devices. If you haven’t already, set up your devices before adding any accessories. ©PICA Product Development, LLC. All rights reserved. Skyhawk, Skyhawk Trapmate, Trapmate Kiwi, Skyhawk Oversea, and Skyhawk PRIoT, are trademarks of PICA Product Development, LLC. 80-QUICKSHELE REV A FCC AND COMPLIANCE This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device many not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation RADIATION EXPOSURE STATEMENT: The device has been found to be compliant to the requirements set forth in CFR 47 Sections 2.1091 for an uncontrolled environment. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. RADIO AND TELEVISION INTERFERENCE: This equipment has been tested and found to comply with the limits, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commissions rules. Interference-Causing Equipment Standard IC ES 003 : This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conform e à la norme NMB-003 du Canada. NOTE: If you’re setting up Skyhawk Hubs and Sensors, you must set up at least one Skyhawk Hub before setting up any of your sensors. Skyhawk is committed to providing you with the most reliable and accurate electronic remote monitoring solutions We make a variety of connectors and adapters to help you easily install and protect your Skyhawk devices. Accessories Visit www.skyhawk.ai/shop to see our full line of accessories and add-ons, as well as other Skyhawk products. We also manufacture custom attachments for our customers who request them. Support To request support for your Skyhawk products, visit www.skyhawk.ai/support. We’d love to hear from you! Let us know what you think about your Skyhawk products, and how we can continue to improve them for you. Send your feedback to [email protected] . Skyhawk.ai | +1 800.760.3966 | [email protected] IMPORTANT SAFETY INFORMATION USE RESTRICTIONS AND NOTICES FOR SKYHAWK PRODUCTS SAFETY AND USE RESTRICTIONS DO NOT USE SKYHAWK PRODUCTS: • IN PLACE OF A LIFE SAFETY DEVICE. • FOR MEDICAL MONITORING. • IN A MANNER THAT VIOLATES ANY FEDERAL, STATE, LOCAL, ADMINISTRATIVE OR OTHER LAW, REGULATION, OR ORDINANCE, INCLUDING BUT NOT LIMITED TO GOVERNANCE OF CRIMINAL OR ILLEGAL ACTIVITY, DATA PRIVACY AND SECURITY, HEALTH AND SAFETY, ANIMAL WELFARE AND/OR WILDLIFE TRAPPING. DO NOT ATTACH SKYHAWK PRODUCTS DIRECTLY TO A LIFE SAFETY OR MEDICAL MONITORING DEVICE. DO NOT PLACE OR POSITION SKYHAWK PRODUCTS WHERE THEY COULD INTERFERE WITH SAFE OPERATION AND FUNCTIONALITY OF LIFE SAFETY, MEDICAL MONITORING OR OTHER EQUIPMENT. BATTERIES (if applicable): The Skyhawk device uses hermetically sealed alkaline batteries. Under normal conditions of use, alkaline batteries are non-toxic and are not hazardous waste per the United States Resource Conservation and Recovery Act (RCRA) - 40 CFR Part 261 Subpart C. Dispose of in accordance with all applicable federal, state and local regulations. WARNING: BATTERIES CAN EXPLODE OR LEAK AND CAUSE BURNS IF INSTALLED BACKWARDS, DISASSEMBLED, CHARGED, OR EXPOSED TO WATER, FIRE OR HIGH TEMPERATURE. EXPOSURE TO THE INGREDIENTS CONTAINED WITHIN OR THEIR COMBUSTION PRODUCTS COULD BE HARMFUL. IMPORTANT NOTICE: The Skyhawk device uses a 3rd-party Wireless Service which uses radio technologies and is subject to transmission and service area limitations, which may include interruptions and dropped connections caused by atmospheric, topographical or environmental conditions, cell site availability, cellular network equipment or its installation, governmental regulations, system limitations, maintenance or other conditions or activities affecting the operation of the Wireless Service. The Wireless Service and/or features may not be available in all areas. For more information, visit www.skyhawk.ai LIMITED WARRANTY ON SKYHAWK PRODUCTS THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY BY STATE, PROVINCE, OR JURISDICTION. THE LIMITED WARRANTY CAN ALSO BE FOUND ONLINE AT SKYHAWK.AI/TERMS-AND-CONDITIONS AND IN THE DOCUMENTATION WE PROVIDE WITH THE PRODUCT. WE WARRANT THAT DURING THE WARRANTY PERIOD, THE PRODUCT WILL BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP. W…
Text truncated - open the document above for the full version.
PICA Product Development LLC 4 Ash Street Extension | Derry | NH | 03038 603.425.1096 | 800.344.4685 picapd.com U.S. Agent Designation for Service of Process - Certification Attestation Letter 8/29/2025 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: UOXSKYHAWKVERSEN1 FRN of applicant: 0015599459 Per section 2.911(d)(7) of the FCC rules, [PICA Product Development] (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: PICA Product Development FCC Registration Number (FRN): 0015599459 Physical U.S. Company Address: 4 Ash Street Extension, Derry, NH 03038 USA Contact Person: Scott Stapleford Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different from Applicant): Signed: Printed name: Scott Stapleford Title: CTO Company Name: PICA Product Development Date: 8/29/2025 * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process.
PICA Product Development LLC 4 Ash Street Extension | Derry | NH | 03038 603.425.1096 | 800.344.4685 picapd.com Covered Equipment Certification Attestation Letter 8/29/2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: UOXSKYHAWKVERSEN1 PICA Product Development (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. PICA Product Development (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. PICA Product Development (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Scott Stapleford Title: CTO Company Name: PICA Product Development Date: 8/29/2025
PICA Product Development LLC 4 Ash Street Extension | Derry | NH | 03038 603.425.1096 | 800.344.4685 picapd.com DATE :2025-8-29 Equipment Authorization Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: UOXSKYHAWKVERSEN1 Product Name: Skyhawk Versa Sensor Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: Schematics Block diagram Operation description BOM Tune up These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this 2025-8-29 By: Scott Stapleford Signature Printed Title: CTO On behalf of: PICA Product Development Telephone: 800-334-4685
PICA Product Development LLC 4 Ash Street Extension | Derry | NH | 03038 603.425.1096 | 800.344.4685 picapd.com DATE:8/29/2025 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Jianyan Testing Group Shenzhen Co., Ltd.; No.101, Building 8, Innovation Wisdom Port, No.155 Hongtian Road, Huangpu Community,Xinqiao Street, Bao'anDistrict, Shenzhen, Guangdong,People's Republic of China., to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with 1688 Meridian Av. Suite 700, Miami Beach,FL,US Dated this 8/29/2025 By: Scott Stapleford Signature Printed Title: CTO On behalf of: PICA Product Development Telephone: 800-334-4685
PICA Product Development LLC 4 Ash Street Extension | Derry | NH | 03038 603.425.1096 | 800.344.4685 picapd.com Date:8/29/2025 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Compliance Testing, LLC to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). Sincerely, Dated this: 8/29/2025 By: Scott Stapleford Signature Printed Title: CTO On behalf of: PICA Product Development Telephone: 800-334-4685
Page 1 of 3FCC ID: UOXSKYHAWKVERSEN1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. External Photos Photo 1 Photo 2 Page 2 of 3FCC ID: UOXSKYHAWKVERSEN1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 3 Photo 4 Page 3 of 3FCC ID: UOXSKYHAWKVERSEN1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 5 Photo 6 ------End------
Label: Label location:
Page 1 of 4FCC ID: UOXSKYHAWKVERSEN1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Internal Photos Photo 1 Photo 2 Page 2 of 4FCC ID: UOXSKYHAWKVERSEN1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 3 Photo 4 Page 3 of 4FCC ID: UOXSKYHAWKVERSEN1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 5 Photo 6 Page 4 of 4FCC ID: UOXSKYHAWKVERSEN1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Photo 7 Photo 8 ------End------
Page 1 of 8Report No.: AiTDG-251127006FW2 Note: This device has been tested and found to comply with the standard(s) listed, this test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Dongguan Yaxu (AiT) Technology Limited. If there is a need to alter or revise this document, the right belongs to Dongguan Yaxu (AiT) Technology Limited, and it should give a prior written notice of the revision document. This test report must not be used by the client to claim product endorsement. Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. RF Exposure evaluation Product Name: Skyhawk Versa Sensor Brand Name: N/A Model: SHVERG Series Model: N/A FCCID: UOXSKYHAWKVERSEN1 Applicant: PICA Product Development Address: 4 Ash Street Extension, Derry, NH 03038 USA Manufacturer: PICA Product Development Address: 4 Ash Street Extension, Derry, NH 03038 USA Standard(s): 47CFR §1.1310,47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Date of Receipt: 01 Aug., 2025 Date of Test: 02 Aug., to 28 Aug., 2025 Issued Date: 29 Aug., 2025 Issued By: Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China Tel.: +86-769-8202 0499 Fax.: +86-769-8202 0495 Reviewed by:Approved by: Emiya LinSimba Huang Page 2 of 8 Report No.: AiTDG-251127006FW2 Report Revise Record Report VersionIssued DateNotes V1.029 Aug., 2025Initial Release Page 3 of 8 Report No.: AiTDG-251127006FW2 Contents 1 GENERAL INFORMATION.............................................................................................................................................4 1.1ENVIRONMENTAL CONDITIONS........................................................................................................................................4 1.2GENERALDESCRIPTIONOFEUT...................................................................................................................................... 4 1.3TESTFACILITY...............................................................................................................................................................5 1.4MEASUREMENT UNCERTAINTY........................................................................................................................................ 6 2 METHOD OF MEASUREMENT......................................................................................................................................7 2.1APPLICABLESTANDARD................................................................................................................................................. 7 2.2EVALUATIONMETHOD ANDLIMIT...................................................................................................................................7 2.3MANUFACTURINGTOLERANCE........................................................................................................................................8 2.4EVALUATIONRESULT......................................................................................................................................................8 2.5CONCLUSION................................................................................................................................................................8 Page 4 of 8 Report No.: AiTDG-251127006FW2 1 GENERAL INFORMATION 1.1 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Normal Temperature: 15 °C ~ 35 °C Relative Humidity:20 % ~ 75 % RH Air Pressure:101 kPa 1.2 General Descriptionof EUT Product Name:Skyhawk Versa Sensor Model/Type reference: SHVERG Serial Model:N/A Power Supply:DC 3V(3V CR2450 Battery * 2) Hardware version.:N/A Software version.:N/A Test sample(s) ID:AiTDG-251127006-2 Lora: Modulation:Frequency Hopping Spread Spectrum Operation frequency:906 MHz – 923.5 MHz Channel number:50 Antenna type:PCB Antenna Antenna gain:0 dBi (declare by applicant) Remark:The above DUT's information was declared by manufacturer. For more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Page 5 of 8 Report No.: AiTDG-251127006FW2 1.3 Test Facility TestLaboratory: Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China The test facility is recognized, certified or accredited by the following organizations: CNAS-Registration No: L6177 Dongguan Yaxu (AiT) technology Limited is accredited to ISO/IEC 17025:2017 general Requirements for the competence of testing and calibration laboratories (CNAS-CL01 Accreditation Criteria for the competence of testing and calibration laboratories) on April 18, 2022 FCC-Registration No.: 703111Designation Number: CN1313 Dongguan Yaxu (AiT) Technology Limited has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. IC-Registration No.: 6819ACAB identifier: CN0122 The 3m Semi-anechoic chamber of Dongguan Yaxu (AiT) Technology Limited has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 6819A A2LA-Lab Cert. No.: 6317.01 Dongguan Yaxu (AiT) Technology Limited has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. Page 6 of 8 Report No.: AiTDG-251127006FW2 1.4 Measurement uncertainty The data and results referenced in this document are true and accurate. The rea…
Text truncated - open the document above for the full version.
Page 1 of 57Report No.: AiTDG-251127006FW1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. TEST REPORT Client Information: Applicant: PICA Product Development Applicant add.: 4 Ash Street Extension, Derry, NH 03038 USA Manufacturer: PICA Product Development Manufacturer add.: 4 Ash Street Extension, Derry, NH 03038 USA Product Information: Product Name: Skyhawk Versa Sensor Model No.: SHVERG Brand Name: N/A FCC ID: UOXSKYHAWKVERSEN1 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Prepared By: Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang,Dongguan, Guangdong, China Tel.: +86-769-8202 0499Fax.: +86-769-8202 0495 Date of Receipt: 01 Aug., 2025Date of Test: 02 Aug., to 28 Aug., 2025 Date of Issue:29 Aug., 2025Test Result: Pass This device described above has been tested by Dongguan Yaxu (AiT) Technology Limited and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Note: This report shall not be reproduced except in full, without the written approval of Dongguan Yaxu (AiT) Technology Limited, this document may be altered or revised by Dongguan Yaxu (AiT) Technology Limited, personal only, and shall be noted in the revision of the document. This test report must not be used by the client to claim product endorsement. Reviewed by:Approved by: Emiya LinSimba Huang Page 2 of 57Report No.: AiTDG-251127006FW1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. 1 Contents Page COVER PAGE 1 CONTENTS......................................................................................................................................................................2 2 TEST SUMMARY............................................................................................................................................................4 2.1Statement of the Measurement Uncertainty.........................................................................................4 2.2Measurement Uncertainty.....................................................................................................................4 3 TEST FACILITY..............................................................................................................................................................5 3.1Deviation from standard........................................................................................................................5 3.2Abnormalities from standard conditions............................................................................................... 5 3.3Test Location......................................................................................................................................... 5 4 GENERAL INFORMATION...........................................................................................................................................6 4.1Test frequencies.................................................................................................................................... 7 4.2EUT Peripheral List............................................................................................................................... 8 4.3Test Peripheral List................................................................................................................................8 4.4TEST METHODOLOGY........................................................................................................................9 4.5Description of Test Modes...................................................................................................................10 5 EQUIPMENT USED DURING TEST.........................................................................................................................11 6 TEST RESULTS AND MEASUREMENT DATA.....................................................................................................13 6.1Antenna requirement...........................................................................................................................13 6.2Peak Power Measurement..................................................................................................................14 6.3Frequency Separation and 20 dB Bandwidth.....................................................................................16 6.4Number of Hopping Frequency...........................................................................................................20 6.5Time of Occupancy (Dwell Time)........................................................................................................22 6.6Conducted Spurious Emissions and Band Edges Test......................................................................24 6.7Radiated Emissions Measurement.....................................................................................................27 7 TEST SETUP PHOTOGRAPHS OF EUT.................................................................................................................57 8 EXTERNAL PHOTOGRAPHS OF EUT....................................................................................................................57 9 INTERNAL PHOTOGRAPHS OF EUT.....................................................................................................................57 Page 3 of 57Report No.: AiTDG-251127006FW1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. REPORT REVISE RECORD Report Version Revise TimeIssued DateValid VersionNotes V1.0/29 Aug., 2025ValidInitial release Page 4 of 57Report No.: AiTDG-251127006FW1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, D…
Text truncated - open the document above for the full version.
0 0.025 0.075 0.235 0.285 2.035 2.175 2.200 0 0.025 0.075 0.151 0.163 1.175 1.200 Ground Plane Notes: 915MHZ1. Matched to 50 Ohms2. PCB thickness: .032"3. Etched on top surface only4. AA BB 4 4 3 3 2 2 1 1 Black Silicone Rubber XHG 151 - Shore 70 Etched Antenna Versa Sensor A DO NOT SCALE DRAWING VERSAANT SHEET 1 OF 1 7/14/25 S.S. UNLESS OTHERWISE SPECIFIED: SCALE: 3:1 WEIGHT: REV DWG. NO. B SIZE TITLE: PICA Product Development NAME DATE COMMENTS: Rev A - 7/14/25 - New Q.A. MFG APPR. ENG APPR. CHECKED DRAWN Gloss FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL .01 THREE PLACE DECIMAL .005 APPLICATION USED ON NEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF PICA PRODUCT DEVELOPMENT. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF PICA PRODUCT DEVELOPMENT IS PROHIBITED. Antenna Gain:0dBi
Page 1 of 2 FCC ID: UOXSKYHAWKVERSEN1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. Test Setup Photo Radiated Emission Page 2 of 2 FCC ID: UOXSKYHAWKVERSEN1 Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling 3rd Street, Jitigang, Huangjiang, Dongguan, Guangdong, China. RF Conduction ------End------
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 906 MHz - 923.5 MHz | 20.00 mW |

Skyhawk Duo Sensor
Equipment Class
DTS - Digital Transmission SystemVibration/Magnet sensors for remote monitoring of rodents/wildlife traps
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Mouse Sensor/Transceiver
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
434.0 MHz CUSTOMER SERVICE BUTTON
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
EASY TOUCH BUTTON- 433 MHZ TRANSMITTER
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter