Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
W415-4096 / 06.10.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • [email protected] INSTALLATION GUIDE W SC-IS Temperature Sensor Label 1. Label 2. Thermostat If you have a C wire, you will not need the label 2 below. Control board CC RC RC RC RC RH RH RR CC SS GG RR RCRC RHRHY2Y2 Y/Y1Y/Y1 Y/Y1Y/Y1 W/W1W/W1 W/W1W/W1 W2W2 O/BO/B ** GG W415-4096 / 06.10.22 2 ! WARNING • Failure to follow these safety notices could result in fire, electric shock, other injuries, or damage to the thermostat and other property. Read all the safety notices below before using the thermostat. • Avoid high humidity or extreme temperatures. • Avoid long exposure to direct sunlight or strong ultraviolet light. • Do not drop or expose the unit to intense vibration. • Do not disassemble or try to repair the unit on your own. • Do not expose the unit or its accessories to flammable liquids, gases, or other explosives. Product Name Model Number FCC IDIC ID Outdoor Temperature Sensor with Probe WSC-OSVA8-WSC-IS 7114A- WSCIS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) The device may not cause harmful interference; and 2) the device must accept any interference received, including interference that may cause undesired operation. 3 W415-4096 / 06.10.22 Pairing the Thermostat and Outdoor Sensor 1.Click the “+” button at the top-right corner of the interface in “Menu” -> “Sensors” on the thermostat and tap “Next”. 2.Remove the rear cover of the sensor. 3.Press and hold the button on the back of the sensor until the indicator on the front of the sensor flashes red. 4.Wait for sensors to pair automatically. When the pairing is successful, the sensor flashes green 3 times. Outdoor Sensor W415-4096 / 06.10.22 4 5.Place the temperature probe of the sensor outdoors while leaving the main body of the sensor indoors. Make sure the sensor is within 10 meters of the thermostat. 5 W415-4096 / 06.10.22 Notes FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐‐ Reorient or relocate the receiving antenna. ‐‐ Increase the separation between the equipment and receiver. ‐‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐‐ Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IC warning: This device contains licence-exempt tasmittre(s)/receiver(s)/ that comply with Innovation Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: 1) this device may not cause interference and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Déclaration de l'ISED Canada : Cet appareil contient des tasmittre (s) / récepteur (s) sans licence / conformes à l'innovationRSS exemptes de licence de Sciences et Développement économique Canada. L'opération est sous réserve des deux conditions suivantes : 1) cet appareil ne peut pas causer d'interférences et 2) ce dispositif doit accepter toute interférence, y compris peut provoquer le fonctionnement indésirable de l'appareil.
Wolf Steel Ltd. Agent Authorization Company: Wolf Steel Ltd. Address: 24 Napoleon Road Barrie, Ontario, L4M 4Y8 Canada Product Name: Temperature Sensor Model Number(s): WSC-IS, WSC-OS Product Description: Temperature Sensor We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Jun. 16, 2022 Name: Paul Hodges Title: Innovation and Engineering Systems Manager Company: Wolf Steel Ltd.
Wolf Steel Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Jun. 16, 2022 Subject; Request for Confidentiality FCC ID: VA 8-WSC-IS To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Paul Hodges Title: Innovation and Engineering Systems Manager
Model Difference Declaration To Whom It May Concern, We, Wolf Steel Ltd. (Temperature Sensor) Trademark:N/A; Model Number:WSC-IS, WSC-OS; All model’s the function, software and electric c ircuit are the same, only with a product model named different for commercial purpose. Test sample model: WSC-IS. Please contact me if you have any question. Name:Paul Hodges Date: Jun. 16, 2022 Title:Innovation and Engineering Systems Manager Signature of applicant:
Annex A External Photos Test Model No.: WSC-IS Page 1 of 4 Test Model No.: WSC-IS Page 2 of 4 Test Model No.: WSC-IS Page 3 of 4 Test Model No.: WSC-IS Page 4 of 4
FCC ID LABEL: Ca. 5mm x 10mm Label Location FCC ID: VA8-WSC-IS
Annex B Internal Photo Test Model No.: WSC-IS Page 1 of 3 Antenna Antenna Test Model No.: WSC-IS Page 2 of 3 Test Model No.: WSC-IS Page 3 of 3
Page 1 of 23 Report No.: HK2205242169-E FCC TEST REPORT Test report On Behalf of Wolf Steel Ltd. For Temperature Sensor Model No.: WSC-IS, WSC-OS FCC ID: VA8-WSC-IS Prepared For : Wolf Steel Ltd. 24 Napoleon Road Barrie, Ontario, L4M 4Y8 Canada Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: May. 24, 2022~Jun. 10, 2022 Date of Report: Jun. 10, 2022 Report Number: HK2205242169-E Page 2 of 23 Report No.: HK2205242169-E TEST RESULT CERTIFICATION Applicant’s name ................. : Wolf Steel Ltd. Address ................................. : 24 Napoleon Road Barrie, Ontario, L4M 4Y8 Canada Manufacture's Name ............ : Xiamen OWON Technology Co., Ltd Address ................................. : Rm501, Tower C07, Softpark Phase 3, Jimei, Xiamen, Fujian, China Product description Trade Mark: N/A Product name ........................... : Temperature Sensor Model and/or type reference : WSC-IS, WSC-OS Standards ............................. : FCC Rules and Regulations Part 15 Subpart C Section 15.249 ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of performance of tests ............. : May. 24, 2022~Jun. 10, 2022 Date of Issue ........................................... : Jun. 10, 2022 Test Result .............................................. : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 23 Report No.: HK2205242169-E Table of Contents Page 1 . TEST SUMMARY 5 1.1 . Test Procedures and Results 5 1.2 . Information of the Test Laboratory 5 1.3 . Measurement Uncertainty 5 2 . GENERAL INFORMATION 6 2.1 . General Description of EUT 6 2.2. Description of Test Setup 7 2.3. Measurement Instruments List 8 3 . CONDUCTED EMISSIONS TEST 9 3.1. Conducted Power Line Emission Limit 9 3.2. Test Setup 9 3.3. Test Procedure 9 3.4. Test Result 10 4 FIELD STRENGTH OF FUNDAMENTAL 11 4.1. Limit 11 4.2. Test Procedure 11 4.3. Test Result 12 5. RADIATED EMISSION TEST 13 5.1. Radiation Limit 13 5.2. Test Setup 13 5.3. Test Procedure 14 5.4. Test Result 14 6. BAND EDGE 18 6.1. Limits 18 6.2. Test Procedure 18 6.3. Test Result 19 7. OCCUPIED BANDWIDTH MEASUREMENT 20 7.1. Test Setup 20 7.2. Test Procedure 20 7.3. Measurement Equipment Used 20 7.4. Test Result 20 8. ANTENNA REQUIREMENT 21 9. PHOTOGRAPH OF TEST 22 10. PHOTOS OF THE EUT 23 Page 4 of 23 Report No.: HK2205242169-E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release Jun. 10, 2022 Jason Zhou Page 5 of 23 Report No.: HK2205242169-E 1. TEST SUMMARY 1.1. Test Procedures and Results DESCRIPTION OF TEST SECTION NUMBERRESULT CONDUCTED EMISSIONS TEST 15.207 N/A RADIATED EMISSION TEST 15.249(a)/15.209 COMPLIANT BAND EDGE 15.249(d)/15.205 COMPLIANT OCCUPIED BANDWIDTH MEASUREMENT 15.215(c) COMPLIANT ANTENNA REQUIREMENT 15.203 COMPLIANT FIELD STRENGTH OF FUNDAMENTAL 15.249(a) COMPLIANT 1.2. Information of the Test Laboratory Shenzhen HUAK Testing Technology Co., Ltd. Add.: 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Testing Laboratory Authorization: A2LA Accreditation Code is 4781.01. FCC Designation Number is CN1229. Canada IC CAB identifier is CN0045. CNAS Registration Number is L9589. 1.3. Measurement Uncertainty Measurement Uncertainty Conducted Emission Expanded Uncertainty =2.71dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.90dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz)= 3.90dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.28dB, k=2 Page 6 of 23 Report No.: HK2205242169-E 2. GENERAL INFORMATION 2.1. General Description of EUT Equipment: Temperature Sensor Model Name: WSC-IS Series Model: WSC-OS Model Difference: All model’s the function, software and electric circuit are the same, only with a product model named different. Test sample model: WSC-IS. FCC ID: VA8-WSC-IS Antenna Type: Internal Antenna Antenna Gain: 1dBi Operation frequency: 915MHz Modulation Type: GFSK Power Source: DC 3V from battery Power Rating: DC 3V from battery Page 7 of 23 Report No.: HK2205242169-E 2.2. Description of Test Setup Operation of EUT during testing: The sample was placed (0.8m below 1GHz, 1.5m above 1GHz) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages. The worst case is X position. EUT Page 8 of 23 Report No.: HK2205242169-E 2.3. Measurement Instruments List Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. L.I.S.N. Artificial Mains Network R&S ENV216 HKE-002 Feb. 18, 2022 1 Year 2. Receiver R&S ESCI 7 HKE-010 Feb. 18, 2022 1 Year 3. RF automatic control unit Tonscend JS0806-2 HKE-060 Feb. 18, 2022 1 Year 4. Spectrum analyzer R&S FSP40 HKE-025 Feb. 18, 2022 1 Year 5. Spectrum analyzer Agilent N9020A HKE-048 Feb. 18, 2022 1 Year 6. Preamplifier Schwarzbeck BBV 9743 HKE-006 Feb. 18, 2022 1 Year 7. EMI Test Receiver R…
Text truncated - open the document above for the full version.
Radiated Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 915 MHz - 915 MHz | - |
Napoleon Prestige Pro
Equipment Class
DTS - Digital Transmission SystemPrestige
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
WiFi Thermostat
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Communications Receiver
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter