FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Masimo Corporation/
  3. VKF-RDS7A

VKF-RDS7ARDS7A

Masimo Corporation
RDS7A - FCC ID VKF-RDS7A - Masimo Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 10, 2015
Application Purpose
Original Equipment
Date of Application
Mar 10, 2015
Equipment Note
RDS7A
Frequency Range
5745.00000000 - 5825.00000000
Company
Masimo Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Root® Operator's Manual www.masimo.com 1 Masimo These operating instructions intend to provide the necessary information for proper operation of the Root®. There may be information provided in this manual that is not relevant for your system. Do not operate Root without completely reading and understanding these instructions. NOTICE: Purchase or possession of this device does not carry any express or implied license to use with replacement parts which would, alone or in combination with this device, fall within the scope of one of the relating patents. CAUTION: Federal law restricts this device to sale by or on the order of a physician. For professional use. See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions and adverse events. Wireless Radio IC:7362A-RDS7A IC Model: RDS7A FCC ID: VFK-RDS7A Model - RDS7A www.masimo.com 2 Masimo Masimo Corporation 40 Parker Irvine, CA 92618, USA Tel.: 949-297-7000 Fax.: 949-297-7001 www.masimo.com EU authorized representative for Masimo Corporation: MDSS GmbH Schiffgraben 41 D-30175 Hannover, Germany Medical electrical equipment with respect to electric shock, fire and mechanical hazards only in accordance with UL 60601-1/CAN/CSA C22.2 No. 601.1 Patents: www.masimo.com/patents.htm © 2014 Masimo Corporation Root, SEDLine, Radical-7, rainbow, SET, Signal Extraction Technology, Masimo and , are federally registered trademarks of Masimo Corporation. MOC-9, Iris and ISA are trademarks of Masimo Corporation. The use of the trademark Patient SafetyNet is under license from University HealthSystem Consortium. All other trademarks and registered trademarks are property of their respective owners. www.masimo.com 3 Masimo Contents About this Manual ----------------------------------------------------------------------------- 7 Product Description, Features and Intended Use ------------------------------------------ 9 Product Description and Features -------------------------------------------------------- 9 Intended Use -------------------------------------------------------------------------------- 9 Indications for Use ----------------------------------------------------------------------- 10 Safety Information, Warnings and Cautions --------------------------------------------- 13 Safety Warnings and Cautions ---------------------------------------------------------- 13 Performance Warnings and Cautions -------------------------------------------------- 14 Cleaning and Service Warnings and Cautions ---------------------------------------- 16 Compliance Warnings and Cautions --------------------------------------------------- 17 Chapter 1- Description ---------------------------------------------------------------------- 19 Features ------------------------------------------------------------------------------------ 19 Chapter 2- Setting Up ----------------------------------------------------------------------- 23 Unpacking and Inspection --------------------------------------------------------------- 23 Guidelines for Setting Up --------------------------------------------------------------- 23 Power On ---------------------------------------------------------------------------------- 24 Initial Battery Charging ------------------------------------------------------------------ 25 Radical-7 Connection -------------------------------------------------------------------- 26 Nurse Call Connection ------------------------------------------------------------------- 26 Chapter 3- Operation ------------------------------------------------------------------------ 29 About the Status Bar --------------------------------------------------------------------- 29 About the Main Screen ------------------------------------------------------------------ 31 Using the Touchscreen Interface ------------------------------------------------------- 33 Menu Navigation ------------------------------------------------------------------------- 37 Understanding Windows ---------------------------------------------------------------- 38 Accessing Main Menu Options --------------------------------------------------------- 45 Alarm Interface --------------------------------------------------------------------------- 60 Root Contents www.masimo.com 4 Masimo Trend Download ---------------------------------------------------------------------------63 Lights----------------------------------------------------------------------------------------64 Chapter 4- Radius-7 --------------------------------------------------------------------------66 Chapter 5- O3 Regional Oximetry----------------------------------------------------------67 Chapter 5- MOC-9 ----------------------------------------------------------------------------69 Using MOC-9 Ports -----------------------------------------------------------------------69 Chapter 7- Iris ---------------------------------------------------------------------------------71 Iris Status Screen --------------------------------------------------------------------------72 Using Iris Connectivity Ports ------------------------------------------------------------73 Chapter 8- Messages -------------------------------------------------------------------------75 Messages------------------------------------------------------------------------------------75 Chapter 9- Troubleshooting -----------------------------------------------------------------77 Troubleshooting Radical-7, Radius-7 and MOC-9 Modules ------------------------77 Troubleshooting Root ---------------------------------------------------------------------77 Chapter 10- Specifications-------------------------------------------------------------------81 Electrical ------------------------------------------------------------------------------------81 Environmental -----------------------------------------------------------------------------81 Display --------------------------------------------------------------------------------------…

Text truncated - open the document above for the full version.

Attestation Statements

01-09-2015 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia , Maryland 21046 To Whom it May Concern: We attest to the following:  Per FCC KDB 443999 D01 v01 and RSS 210 Annex 9, this device will not transmit in the 5600 - 5650 MHz band  Per FCC KDB 848637, the device is a client device with no radar detection capability. The client software and associated drivers will not initiate any transmission on DFS frequencies without initiation by a master. This includes restriction on transmissions for beacons and support for ad- hoc peer-to-peer modes.  Per FCC KDB 594280 D01 v01r02, the device complies with the requirements for software configuration control. The device meets the definition of FCC 15.202 client device and does not have the ability to be configured by end users or professional installers to operate outside the authorized bands  Per FCC 15.407(c), the device will automatically discontinue transmission in case of either absence of information to transmit or operational failure. Michael Clark Signature

Cover Letter(s)

WTD 13.4.9 FCC Compliance Opinion MASI0237 Information about the Applicant Grantee (Company Name) Masio Corporation FCC Contact Person Eugene Kim Address 40 Parker City, State, Zip Irvine, CA 92618 Job Number MASI0237 Model RDS7A FCC ID VKF-RDS7A Agent Michael Clark Approval Type Original Equipment Class DTS Digital Transmission System Rule Part unlicensed 15.209 15.247 Overview RDS7A/ROOT V2 is a multi-functional general floor monitoring device designed for use with integrated radio and is described as follows: ・ Provides wireless communication for patient monitoring equipment, communicating simultaneously with multiple patient monitoring devices. ・ Provides wireless communication to store and transfer medical data to Masimo patient safety net or customer-designated servers and electronic medical record systems. The RDS7A/ROOT V2 may be used to provide a unique patient identifier for all records. ・ Supports 802.11 a/b/g wireless/Bluetooth connectivity. Confidentiality requested for allowed files. Request is properly addressed and referenced. Recommendation All items have been resolved and completed to my satisfaction; therefore I recommend this application for approval. Signature Rod Munro, TCB Committee 1/26/2015

ID Label/Location Info

Label, Cerications, Root-RDS-7, new radio, Masimo LAB-8293B CO-017270 09/14 100-240V~47-63 Hz 65VA MAX Model - RDS7A Designed by Masimo in California Masimo Corporation, 40 Parker Irvine, CA 92618 USA IC: 7362A-RDS7A IC Model: RDS7A FCC ID: VKF-RDS7A IC: 7362A-RDS7A IC Model: RDS7A FCC ID: VKF-RDS7A This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Patents: http://www.masimo.com/patents.htm 37193/8293B-0914 5.660 typ outside radius .085 R (this cutout only) .04 R 3.300 IPX1IPX1 MEDICAL ELECTRICAL EQUIPMENT UL 60601-1/CAN/CSA C22.2 No. 601.1 80FK

Operational Description

Ethertronics’ Prestta series of Isolated Magnetic Dipole™ (IMD) trace antennas address the challenges facing today’s product designers. IMD’s high perfor- mance and isolation characteristics offer better con- nectivity and minimal interference. IMD antennas can be used in a variety of devices:  Notebook Computers  Access Points  WiFi enabled Televisions & Monitors PRODUCT: WLAN Prestta TM WLAN Embedded Antenna 2.4/4.9/5.2/5.8 GHz (802.11 a/b/g/n + Japan) Part No. 9000129 & 9000130 TECHNOLOGY ADVANTAGES Prestta WLAN antennas use patented IMD technology in a trace configuration to provide high performance. IMD antennas requires a smaller design keep-out area, carry lower program development risk which yields a quicker time-to-market, without sacrificing RF performance. Stays in Tune IMD antenna technology provides superior RF field containment, resulting in less interaction with surrounding components. Ethertronics IMD antennas resist de-tuning; providing a robust radio link regardless of the usage position. KEY BENEFITS SERVICE AND SUPPORT Extensive RF Experience  Our WLAN antennas are supported by documentation, and when needed, by the expertise of RF engineers who have integrated hundreds of antenna designs into wireless devices. Global Operations & Design Support  Ethertronics’ global operations supports an integrated network of design centers that can take projects from concept to production. END USER ADVANTAGES Unique Form Factors Support Advanced Industrial Designs  Smaller, more efficient IMD embedded antennas break through restrictive design rules and provide new free- dom in component placement. Superior Range & Signal Strength  Better antenna function means longer range and great- er sensitivity to critically precise signals—delivering greater customer satisfaction while building brand loy- alty. DESIGN ADVANTAGES Quicker Time-to-Market  By optimizing antenna size, performance and emis- sions, customer and regulatory specifications are more easily met. Greater Flexibility  Ethertronics’ first-in-class IMD technology enables you to develop concept designs that are more advanced and that deliver superior performance in reception- critical applications.  Multiple cable lengths to fit a variety of devices. RoHS Compliant  Ethertronics’ antennas are fully compliant with the European RoHS Directive 2002/95/EC. ETHERTRONICS 5501 Oberlin Drive, Suite 100, San Diego, CA. 92121, USA www.ethertronics.com Tel +(1) 858.550.3820 | fax +(1) 858.550.3821 | contact: [email protected] PRODUCT: WLAN a/b/g/n + Japan - P/N 9000129 & 9000130 Dimensions 42.0 x 8.0 x 0.8 mm Weight 0.4 g Cable / Connector U.fl Connector, 1.13mm diameter coaxial cable. Cable Length 100mm cable Main Antenna Substrate P/N 9000129: Based on PCB substrate P/N 9000130: Based on FPC substrate Mechanical Specification Ethertronics’ Internal (Embedded) Antenna Specifications. Below are the typical specs for a WLAN application. Electrical Specification Typical Characteristics (In reference device housing made of PC/ABS plastic) WLAN a/b/g/n + Japan Antenna (GHz) 2.390-2.490 b, g 4.900-5.100 Japan 5.150-5.350 a 5.35-5.90 a Peak Gain in dBi 2.0 4.0 5.0 6.0 Efficiency 65% 72% 72% 65% Return Loss in dB < -10.0 < -10.0 < -10.0 < -10.0 Feed Point Impedance 50 Ω unbalanced (other if required) Return Loss in dB Efficiency in % ETHERTRONICS 5501 Oberlin Drive, Suite 100, San Diego, CA. 92121, USA www.ethertronics.com Tel +(1) 858.550.3820 | fax +(1) 858.550.3821 | contact: [email protected] Ethertronics’ Internal (Embedded) Antenna Specifications. Below are the typical specs for a WLAN application. 2.4GHz 5GHz © 2013 Ethertronics. All rights reserved. Ethertronics, the Ethertronics logo, shaping antenna technology, Prestta, Savvi, Tavvel, Isolated Magnetic Dipole and the iMD logo are trademarks of Ethertronics. All other trademarks are the property of their respective owners. Specifications subject to change and are dependent upon actual implementation. 9000129 & 9000130 1May2013 PRODUCT: WLAN a/b/g/n + Japan - P/N 9000129 & 9000130

RF Exposure Info

This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. This Report may only be duplicated in its entirety Masimo Corporation RDS7A/ROOT V2 FCC 2.1091:2014 Maximum Permissible Exposure Report # MASI0237.8 NVLAP Lab Code: 200881-0 WTD 13.9.30 CERTIFICATE OF EVALUATION Product compliance is the responsibility of the client, therefore the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. Evaluation Date: September 25, 2014 Masimo Corporation Model: RDS7A/ROOT V2 Radio Equipment Evaluation Standards Specification Method FCC 2.1091:2014 KDB 447498 D01 v05r02 Results Method Clause Test Description Applied Results Comments 7.1 Maximum Permissible Exposure Yes Pass Deviations From Standards None Approved By: Don Facteau, IT Manager Report No. MASI0237.82/10 REV 2012.08.02 REVISION HISTORY Revision Number Description Date Page Number 00 None Barometric Pressure The recorded barometric pressure has been normalized to sea level. Report No. MASI0237.83/10 REV 2012.05.24 ACCREDITATIONS AND AUTHORIZATIONS United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC Guide 65 as a product certifier. This allows Northwest EMC to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada IC - Recognized by Industry Canada as a Certification Body (CB). Certification chambers and Open Area Test Sites are filed with IC. European Union European Commission – Validated by the European Commission as a Conformity Assessment Body (CAB) under the EMC directive and as a Notified Body under the R&TTE Directive. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea KCC / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Hong Kong OFTA – Recognized by OFTA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. SCOPE For details on the Scopes of our Accreditations, please visit: http://www.nwemc.com/accreditations/ Report No. MASI0237.84/10 REV 2013.06.28 FACILITIES Oregon Labs EV01-12 22975 NW Evergreen Pkwy Hillsboro, OR 97124 (503) 844-4066 California Labs OC01-13 41 Tesla Irvine, CA 92618 (949) 861-8918 New York Labs NY01-04 4939 Jordan Rd. Elbridge, NY 13060 (315) 685-0796 Minnesota Labs MN01-08 9349 W Broadway Ave. Brooklyn Park, MN 55445 (763) 425-2281 Washington Labs NC01-0 5,SU02,SU07 19201 120 th Ave. NE Bothell, WA 98011 (425) 984-6600 VCCI A- 0108 A- 0029 A- 0109 A- 0110 Industry Canada 2834D-1, 2834D-2 2834B-1, 2834B-2, 2834B-3 2834E-1 2834F-1 NVLAP NVLAP Lab Code: 200630-0 NVLAP Lab Code: 200676-0 NVLAP Lab Code: 200761-0 NVLAP Lab Code: 200881-0 NVLAP Lab Code: 200629-0 Report No. MASI0237.85/10 WTD 13.9.30 PRODUCT DESCRIPTION Client and Equipment Under Test (EUT) Information Company Name: Masimo Corporation Address: 40 Parker City, State, Zip: Irvine, CA 92618 Test Requested By: Michael Clark Model: RDS7A/ROOT V2 First Date of Test: September 25, 2014 Last Date of Test: September 25, 2014 Receipt Date of Samples: January 19, 2014 Equipment Design Stage: Production Equipment Condition: No Damage Information Provided by the Party Requesting the Test Functional Description of the EUT: Pulse Co-Oximeter. 802.11(a/b/g) radio module. 1 stream and 1 antenna. Client Justification: The radio contained within Model RAD7A/Radical 7 is Identical to the radio contained within Model RDS7A/ROOT V2 Testing Objective: To demonstrate compliance to FCC 2.1091 Maximum Permissible Exposure requirements. EUT Photo Report No. MASI0237.86/10 WTD 13.9.30 PRODUCT DESCRIPTION Report No. MASI0237.87/10 WD.12.29.11 Maximum Permissible Exposure (MPE) OVERVIEW Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate, since exposures are assumed to occur at distances of 20 cm or more from persons. ANSI C95.1-1992 specifies a minimum separation distance of 20 cm for performing reliable field measurements to determine adherence to MPE limits. If the minimum separation distance between a transmitter and nearby persons is more than 20 cm under normal operating conditions, compliance with MPE limits may be determined at such distance from the transmitter. When applicable, operation instructions and prominent warning labels may be used to alert the exposed persons to maintain a specified distance from the transmitter or to limit their exposure durations and usage conditions to ensure compliance. If the use of warning labels on a transmitter is not effective or desirable, the alternative of performing SAR evaluation with the device at its closest range to persons under normal operating conditions may be used. The field strength and power density limits adopted by the FCC are based on whole-body averaged exposure and the assumption of RF field levels relate most accurately to estimating whole-body averaged SAR. This means some local values of exposures exceeding the stated field strength and power density limits may not necessarily imply non-compliance if the s…

Text truncated - open the document above for the full version.

Test Report

This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. This Report may only be duplicated in its entirety Masimo Corporation RDS7A/ROOT V2 FCC 15.207:2014 FCC 15.407:2014 Report # MASI0237 Rev. 1 NVLAP Lab Code: 200676-0 WTD 13.9.30 CERTIFICATE OF TEST Product compliance is the responsibility of the client; therefore, the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. Last Date of Test: September 16, 2014 Masimo Corporation Model: RDS7A/ROOT V2 Radio Equipment Testing Standards Specification Method FCC 15.207:2014 ANSI C63.10:2009 FCC 15.407:2014 ANSI C63.10:2009 Results Method Clause Test Description Applied Results Comments 6.2 AC Powerline Conducted Emissions Yes Pass 6.5, 6.6 Spurious Radiated Emissions Yes Pass 6.7 Band Edge Compliance No N/A Not required, 5GHz band (ch 100-140) not used 6.8 Frequency Stability Yes Pass 6.9.1 Emission Bandwidth Yes Pass 6.10.3 Peak Transmit Power Yes Pass 6.10.4 Peak Excursion of the Modulation Envelope Yes Pass 6.11.1 Peak Power Spectral Density Yes Pass 7.5 Duty Cycle Yes Pass Deviations From Test Standards None Approved By: Victor Ratinoff, Operations Manager Report No. MASI0237 Rev. 12/59 REVISION HISTORY REV 2014.10.14 Revision Number Description Date Page Number 00 None 01 Revised test description 01/23/2015 16 Report No. MASI0237 Rev. 13/59 ACCREDITATIONS AND AUTHORIZATIONS REV 2014.10.08 United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC Guide 65 as a product certifier. This allows Northwest EMC to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada IC - Recognized by Industry Canada as a Certification Body (CB). Certification chambers and Open Area Test Sites are filed with IC. European Union European Commission – Validated by the European Commission as a Conformity Assessment Body (CAB) under the EMC directive and as a Notified Body under the R&TTE Directive. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea MSIP / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Israel MOC – Recognized by MOC as a CAB for the acceptance of test data. Hong Kong OFTA – Recognized by OFTA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. SCOPE For details on the Scopes of our Accreditations, please visit: http://www.nwemc.com/accreditations/ Report No. MASI0237 Rev. 14/59 REV 2013.03.8 MEASUREMENT UNCERTAINTY Measurement Uncertainty When a measurement is made, the result will be different from the true or theoretically correct value. The difference is the result of tolerances in the measurement system that cannot be completely eliminated. To the extent that technology allows us, it has been our aim to minimize this error. Measurement uncertainty is a statistical expression of measurement error qualified by a probability distribution. A measurement uncertainty estimation has been performed for each test per our internal quality document WP 342. The estimation is used to compare the measured result with its "true" or theoretically correct value. The expanded measurement uncertainty (K=2) for each test is listed below. Our measurement data meets or exceeds the measurement uncertainty requirements of the applicable specification; therefore, the test data can be compared directly to the specification limit to determine compliance. The calculations for estimating measurement uncertainty are based upon ETSI TR 100 028 (or CISPR 16-4-1 as applicable), and are available upon request. The following table represents the Measurement Uncertainty (MU) budgets for each of the tests that may be contained in this report. Test + MU - MU Frequency Accuracy (Hz) 0.12 -0.01 Amplitude Accuracy (dB) 0.49 -0.49 Conducted Power (dB) 0.41 -0.41 Radiated Power via Substitution (dB) 0.69 -0.68 Temperature (degrees C) 0.81 -0.81 Humidity (% RH) 2.89 -2.89 Field Strength (dB) 3.80 -3.80 AC Powerline Conducted Emissions (dB) 2.94 -2.94 Report No. MASI0237 Rev. 15/59 FACILITIES REV 2015.1.05 California Labs OC01-13 41 Tesla Irvine, CA 92618 (949) 861-8918 Minnesota Labs MN01-08, MN10 9349 W Broadway Ave. Brooklyn Park, MN 55445 (612)-638-5136 New York Labs NY01-04 4939 Jordan Rd. Elbridge, NY 13060 (315) 685-0796 Oregon Labs EV01-12 22975 NW Evergreen Pkwy Hillsboro, OR 97124 (503) 844-4066 Texas Labs TX01-09 3801 E Plano Pkwy Plano, TX 75074 (469) 304-5255 Washington Labs NC01-05 19201 120 th Ave NE Bothell, WA 9801 (425)984-6600 NVLAP NVLAP Lab Code: 200676-0 NVLAP Lab Code: 200881-0 NVLAP Lab Code: 200761-0 NVLAP Lab Code: 200630-0 NVLAP Lab Code:201049-0 NVLAP Lab Code: 200629-0 Industry Canada 2834B-1, 2834B-3 2834E-1 N/A 2834D-1, 2834D-2 2834G-1 2834F-1 BSMI SL2-IN-E-1154R SL2-IN-E-1152R N/A SL2-IN-E-1017 SL2-IN-E-1158R SL2-IN-E-1153R VCCI A-0029 A-0109 N/A A-0108 A-0201 A-0110 Report No. MASI0237 Rev. 16/59 WTD 13.9.30 PRODUCT DESCRIPTION Client and Equipment Under Test (EUT) Information Company Name: Masimo Corporation Address: 40 Parker City, State, Zip: Irvine, CA 92618 Test Requested By: Michael Clark Model: RDS…

Text truncated - open the document above for the full version.

Test Report

This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. This Report may only be duplicated in its entirety Masimo Corporation RDS7A/ROOT V2 FCC 15.207:2014 FCC 15.247:2014 Report # MASI0237.1 NVLAP Lab Code: 200676-0 WTD 13.9.30 CERTIFICATE OF TEST Product compliance is the responsibility of the client; therefore, the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. Last Date of Test: September 17, 2014 Masimo Corporation Model: RDS7A/ROOT V2 Radio Equipment Testing Standards Specification Method FCC 15.207:2014 ANSI C63.10:2009 FCC 15.247:2014 ANSI C63.10:2009 Results Method Clause Test Description Applied Results Comments 6.2 AC Powerline Conducted Emissions Yes Pass 6.5, 6.6 Spurious Radiated Emissions Yes Pass 6.7 Spurious Conducted Emissions Yes Pass 6.9.1 Occupied Bandwidth Yes Pass 6.10.1 Output Power Yes Pass 7.7.2 Channel Separation Yes Pass 7.7.3 Number of Hopping Channels Yes Pass 7.7.4 Dwell Time Yes Pass 7.5 Duty Cycle Yes N/A 7.7.9 Band Edge Compliance Yes Pass 7.7.9 Band Edge Compliance- Hopping Mode Yes Pass Deviations From Test Standards None Approved By: Victor Ratinoff, Operations Manager REV 2012.08.02 REVISION HISTORY Revision Number Description Date Page Number 00 None Barometric Pressure The recorded barometric pressure has been normalized to sea level. REV 2014.08.11 ACCREDITATIONS AND AUTHORIZATIONS United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Accredited by A2LA to ISO / IEC Guide 65 as a product certifier. This allows Northwest EMC to certify transmitters to FCC and IC specifications. NVLAP - Each laboratory is accredited by NVLAP to ISO 17025 Canada IC - Recognized by Industry Canada as a Certification Body (CB). Certification chambers and Open Area Test Sites are filed with IC. European Union European Commission – Validated by the European Commission as a Conformity Assessment Body (CAB) under the EMC directive and as a Notified Body under the R&TTE Directive. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea MSIP / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Israel MOC – Recognized by MOC as a CAB for the acceptance of test data. Hong Kong OFTA – Recognized by OFTA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. SCOPE For details on the Scopes of our Accreditations, please visit: http://www.nwemc.com/accreditations/ REV 2013.03.8 MEASUREMENT UNCERTAINTY Measurement Uncertainty When a measurement is made, the result will be different from the true or theoretically correct value. The difference is the result of tolerances in the measurement system that cannot be completely eliminated. To the extent that technology allows us, it has been our aim to minimize this error. Measurement uncertainty is a statistical expression of measurement error qualified by a probability distribution. A measurement uncertainty estimation has been performed for each test per our internal quality document WP 342. The estimation is used to compare the measured result with its "true" or theoretically correct value. The expanded measurement uncertainty (K=2) for each test is listed below. Our measurement data meets or exceeds the measurement uncertainty requirements of the applicable specification; therefore, the test data can be compared directly to the specification limit to determine compliance. The calculations for estimating measurement uncertainty are based upon ETSI TR 100 028 (or CISPR 16-4-1 as applicable), and are available upon request. The following table represents the Measurement Uncertainty (MU) budgets for each of the tests that may be contained in this report. Test + MU - MU Frequency Accuracy (Hz) 0.12 -0.01 Amplitude Accuracy (dB) 0.49 -0.49 Conducted Power (dB) 0.41 -0.41 Radiated Power via Substitution (dB) 0.69 -0.68 Temperature (degrees C) 0.81 -0.81 Humidity (% RH) 2.89 -2.89 Field Strength (dB) 3.80 -3.80 AC Powerline Conducted Emissio…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Anamidevi Joshi(EMC Manager)
[email protected]949-297-7663Fax: 949-297-7199

Test Firm

Northwest EMC, Inc.Greg Kiemel
[email protected]503-844-4066Fax: 503-844-3826

Technical Specifications

#Rule PartsFrequency RangePower Output
215C5.75 GHz - 5.83 GHz101.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. Installers and end-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Masimo Corporation

VKF-MASIFDM1

Masimo Freedom Watch

Mar 16, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Stork - FCC ID VKF-STORKC - Masimo Corporation
VKF-STORKC

Stork

Jul 31, 2023

Equipment Class

DTS - Digital Transmission System
Baby Sensor - FCC ID VKF-STORK - Masimo Corporation
VKF-STORK

Baby Sensor

Mar 01, 2023

Equipment Class

DTS - Digital Transmission System
Masimo W1 - FCC ID VKF-MASIW1 - Masimo Corporation
VKF-MASIW1

Masimo W1

Jun 21, 2022

Equipment Class

DTS - Digital Transmission System
MightySat - FCC ID VKF-MSAT01A - Masimo Corporation
VKF-MSAT01A

MightySat

May 20, 2015

Equipment Class

DTS - Digital Transmission System