Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RESPONDERS Wärtsilä Guidance Marine Ltd, 5 Tiber Way, Meridian Business Park, Leicester, LE19 1QP, UK T: +44 116 229 2600 E: [email protected] www.guidance.eu.com www.marine.direct www.wartsila.com USER’S GUIDE 294-0649-A Responder User’s Guide Issue Date: 05/03/2020 Document No: 94-0649-A Serial No: Sensor Software Version:Client Software Version: Date of Shipment from UK: Copyright © Wärtsilä Guidance Marine Limited. All Rights Reserved. Copyright in the whole and every part of this document belongs to Wärtsilä Guidance Marine Limited (the “Owner”) and may not be used, sold, transferred, copied or reproduced in whole or in part in any manner or form or in or on any media to any person other than in accordance with the terms of the Owner’s Agreement or otherwise without the prior written consent of the Owner. “RadaScan” is a registered trademark of Wärtsilä Guidance Marine Ltd. All other brand and product names are trademarks of their respective companies or organisations. Wärtsilä Guidance Marine Ltd, 5 Tiber Way, Meridian Business Park, Leicester, LE19 1QP United Kingdom T: +44 116 229 2600 UK Support: +44 116 229 2665 (365 days a year; 08:00 - 20:00 UTC) USA Support: +1 504 305-1120 Asia Support: +65 6734 6365 [email protected] W: www.guidance.eu.com/customer-support Document History 394-0649-A Document NumberChangesIssue Date 94-0649-AFirst release of Responder User’s Guide05/03/2020 Table of Contents 494-0649-A 1. Installing Responders 1.1 Responder Overview 6 1.2 Positioning Responders 8 1.3 Mounting Responders 9 1.4 Charging Responders 11 1.5 Operating Responders 12 2. Additional Information 2.1 International Standards Compliance 14 2.2 System Specifications 15 2.3 Part Numbers 16 Index 17 1.Installing Responders 1.1 1.2 1.3 1.4 1.5 594-0649-A 6 8 9 11 12 Responder Overview Positioning Responders Mounting Responders Charge Responders Operating Responders 1.1 Series 3 and 4 Responders can be used with RadaScan and RadaScan View systems. One or more Responders should be mounted on the target platform or vessel. There are three models of RadaScan Series 3 Responder: • Rechargeable (Part No. 20-0189-2) • Primary Cell Responder (Part No. 20-0194-2) • ISPP Powered (Part No. 20-0195-2) • Primary Cell Pack (Part No. 21-0375-1) The ISPP Powered Responder is used with Series 3 and 4 ISPP Responder Power Supply (Part No. 21-0377-2). There are three models of RadaScan Series 4 Responder: • Rechargeable Responder (Part No. 20-0276) • Primary Cell Pack Responder (Part No. 20-0284) • ISPP Responder (Part No. 20-0286) • Primary Cell Pack (Part No. 21-0505) The Series 3 and Series 4 Primary Cell Responders are powered by different Primary Cell Packs (Part No. 21-0375-1 - Series 3 | Part No. 21-0505 - Series 4). This requires battery replacement as routine maintenance. This should be undertaken by Wärtsilä Guidance Marine, or by a suitably qualified service technician. Installing Responders 1 694-0649-A Responder Overview !Do not open the Responder. It should only be serviced by Wärtsilä Guidance Marine service technician. If you experience any problems with the unit, please contact: Wärtsilä Guidance Marine Ltd, 5 Tiber Way, Meridian Business Park, Leicester, LE19 1QP, United Kingdom Tel: +44 (0)116 229 2665 Email: [email protected] RadaScan Responder This drawing is linked to a scheduled drawing. Please ensure that any changes made to this drawing do not affect the scheduled drawing. Any changes must be approved by Wartsila. Note: Label Material - 3M Type 76759 (UL File MH18072)• Printing Ink - Armor AXR7• 2575 = QAN Notified Body Number• 20-0286-XXX i.e. XXX = colour variant. e.g. 20-0286-YEL (or BLU, RED, GRE) Rev X i.e. 1 wild card. e.g. Rev A meaning Revision A Tom Coggins Paul Betteridge J Morgan REVISIONS ZONEREV.JIRADESCRIPTIONDATEAPPROVED P00Initial Release28/08/2018JM P01CSA modification06/06/2019JM AProduction release15/10/2019JM ALLA01RAD-1050Updated information on label17/12/2019JM ALLA02RAD-1097Further changes required09/01/2020JM D E F C 1234 B A 3215 C D 4678 A B C:\GUIDANCE1\Projects\Low Power Responder\ CHECK'D REV: THIRD ANGLE PROJECTION - A3 SHEET 1 OF 1 SCALE:2:1 DWG NO. TITLE: MATERIAL: DATENAME ALL PARTS TO BE FREE FROM BURRS, SHARP EDGES, FLASHING, AND CORROSION FINISH: UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN MILLIMETERS APPV'D DRAWN SURFACE FINISH (μm) UNLESS OTHERWISE SPECIFIED: 3.2 UNLESS OTHERWISE SPECIFIED, LINEAR AND ANGULAR DIMENSIONS ACCORDING TO ISO 2768-fk Low Power Series 4 Responder ISPP Product Label WEIGHT: 96-0249 See Drawing A02 Information contained on this document is the property of Wartsila and is issued solely for the purpose of the Contract to which it refers.It must not be reproduced, loaned, given, sold or transmitted in any other manner to any other person or company, or used for any other purpose whatsoever except with the express written permission of Wartsila © 2020 Jeff Morgan17/12/2019 - E REV:DWG NO. DO NOT SCALE DRAWING IF IN DOUBT ASK A0296-0249 DRAWING TO BS 8888 SIGNATURE SHEET SIZE STATUS: ATEX Certification Label (for illustration purposes only - actual label may be formatted differently) 1.1 Instructions for Safe Selection, Installation, Use, Maintenance, Repair and Transport User instructions (in compliance with ATEX 94/9/EC Directive) Installing Responders 1 794-0649-A Responder Overview (continued) Use in Hazardous Environments •Series 3 and 4 Responders and primary cell packs may be used in zones 0, 1 or 2 with flammable gases. •All Series 3 and 4 Responders and primary cell packs may be used in the presence of flammable gases and vapours with gas group IIB and with temperature class T4. •The equipment is certified for use in ambient temperatures in the applicable range shown above and should not be used outside this range. Installation and Maintenance •Responders must be installed by suitably trained personnel in accordance with the applicable code of practice (typically IEC EN 60079-14).…
Text truncated - open the document above for the full version.
� WA�TSILA Federal Communications Commission Authorization and Evaluation Division Gentlemen, This equipment meets the requirements of the FCC Rules, Part 90.20 3( e ) and ( g ) , as applicable. Programming of this product's transmit frequencies can be performed ON LY by the manufacturer or by service or maintenance personnel. The operator cannot program transmit frequencies using the equipment's external operation controls. Sincerely, Thomas James C oggins
Job # 325UT20, Guidance Marine Limited. Series 4 Radar Responder External Photographs Overall Device External Photographs Front External Photographs Back External Photographs Top External Photographs Bottom External Photographs Left Side Right Side
Job # 325UT20, Guidance Marine Limited. Series 4 Radar Responder Internal Photographs Antenna PCB, Front Internal Photographs Antenna PCB, Back Internal Photographs Control PCB, Front Internal Photographs Control PCB, Back
849 NW STATE ROAD 45 PHONE: 888.472.2424 OR 352.472.5500 NEWBERRY, FL 32669 USA EMAIL: [email protected] WEB: HTTP://WWW.TIMCOENGR.COM An IIA Company RF Exposure Evaluation Report APPLICANT Guidance Marine Limited ADDRESS 5 Tiber Way, Meridian Business Park Leicester LE19 1RP FCC ID VYMRAD-1100 MODEL NUMBER RAD-1100 PRODUCT DESCRIPTION Series 4 Responder Radar DATE SAMPLE RECEIVED FEB 20 2020 FINAL TEST DATE AUG 10 2020 PREPARED BY Franklin Rose TEST RESULTS PASS FAIL Report Number Report Version Description Issue Date 325UT20 MPE_TestReport_ Rev1 Initial Issue AUG 10 2020 THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC. TA BLE OF CONTENTS GENERAL REMARKS ........................................................................................................ 2 EUT INFORMATION ........................................................................................................ 3 ANTENNA INFORMATION ............................................................................................... 3 FCC MPE SEPARATION .................................................................................................... 4 Applicant: Guidance Marine Limited Report: 325UT20 MPE_TestReport_Rev1 Page 2 of 5 GENERAL REMARKS Summary The device under test does: Fulfill the general approval requirements as identified in this test report and was selected by the customer. Not fulfill the general approval requirements as identified in this test report Attestations This equipment has been tested in accordance with the standards identified in this test report. To the best of my knowledge and belief, these tests were performed using the measurement procedures described in this report. All instrumentation and accessories used to test products for compliance to the indicated standards are calibrated regularly in accordance with ISO 17025 requirements. I attest that the necessary measurements were made at: Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Designation #: US1070 Prepared by: Name and Title Franklin Rose, Project Manager / EMC Specialist Date AUG 10 2020 Applicant: Guidance Marine Limited Report: 325UT20 MPE_TestReport_Rev1 Page 3 of 5 EUT INFORMATION EUT Description Series 4 Responder Radar Model Number RAD-1100 Modified for Testing ☐ Modification Antenna Connector ☐ UHF ☐ BNC ☐ N ☐ TNC ☐ SMA ☒ Other (n/a) EUT Power Source ☐ AC Power (110-120 V) ☒ DC Power ☐ DC Battery (7.4 V) Test Item ☐ Engineering Prototype ☒ Pre-Production ☐ Post-Production Type of Equipment ☒ Fixed ☐ Mobile ☐ Portable ANTENNA INFORMATION Manufacturer Provides Antenna Type Max Gain (dBi) Yes PCB/Integral 11.9 dBi Applicant: Guidance Marine Limited Report: 325UT20 MPE_TestReport_Rev1 Page 4 of 5 FCC MPE SEPARATION ParameterValueUnit EUT Form Factor Lowest Frequency9200.000 MHz Highest Frequency9300.000 MHz Maximum Power4.000 Tune Up Tolerance0.000 Duty Cycle100% % Antenna Gain11.900 Coax Loss0.000 EIRP0.039W EUT Parameters Separation Distance (cm) Pow e r De nsity (mW/cm 2 ) Separation Distance (cm) Pow e r De nsity (mW/cm 2 ) 0.008 mW/cm2 Controlled Occupational RF Exposure/MPE Guideline 20 cm 0.008 mW/cm2 Uncontrolled Public RF Exposure/MPE Guideline 20 cm Applicant: Guidance Marine Limited Report: 325UT20 MPE_TestReport_Rev1 Page 5 of 5 FCC MPE CALCULATION END OF REPORT RF Exposure Field Strength Limits Separation Distance Calculation Method Uncontrolled Sep. Distance @ 1 mW/cm2 Controlled Sep. Distance @ 5 mW/cm2 EUT Power Density at 20 cm Calculation Method EUT Pow er Density @ 20 cm Calculations Public Persons may be exposed up to: Worst-Case RF Field Strength Limit for the General Public (Uncontrolled Environment) 1 mW/cm2 Distance from Radiating Element (cm) = SQRT (P(mW) / 4π S(mW/cm 2 )) 1.76 cm 0.79 cm Power Density (mW/cm 2 ) = P(mW) / 4π R(cm) 2 Occupational Persons may be exposed up to: Worst-Case RF Field Strength Limit for Controlled Use (Controlled Environment) Mandatory distance from radiating element: 0.008 mW/cm2 5 mW/cm2
849 NW STATE ROAD 45 PHONE: 352.472.5500 NEWBERRY, FL 32669 USA EMAIL: [email protected] WEB: HTTP://WWW.TIMCOENGR.COM An IIA Company FCC CFR 47 Part 80 Radar Test Report APPLICANT Guidance Marine Limited ADDRESS 5 Tiber Way, Meridian Business Park Leicester LE19 1RP FCC ID VYMRAD-1100 MODEL NUMBER RAD-1100 PRODUCT DESCRIPTION Series 4 Responder Radar DATE SAMPLE RECEIVED FEB 20 2020 FINAL TEST DATE AUG 10 2020 TESTED BY Franklin Rose APPROVED BY Tim Royer TEST RESULTS ☒ PASS ☐ FAIL Report Number Report Version Description Issue Date 325UT20_PT80 Radar TestReport_ Rev1 Initial Issue AUG 10 2020 325UT20_PT80 Radar TestReport_ Rev2 Clerical Updates SEP 18 2020 THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC. TABLE OF CONTENTS SIGNATURE PAGE .............................................................................................................................................. 2 T ESTING INFORMATION .......................................................................................................................................... 3 SUMMARY OF TESTING ...................................................................................................................................... 4 RF POWER OUTPUT ........................................................................................................................................... 5 T EST DATA: POWER OUTPUT 9.2 GHZ .................................................................................................................. 6 T EST DATA: POWER OUTPUT 9.25 GHZ ................................................................................................................ 7 T EST DATA: POWER OUTPUT 9.3 GHZ .................................................................................................................. 8 T EST DATA: POWER AT THE FINAL AMPLIFIER .......................................................................................................... 9 OCCUPIED BANDWIDTH .................................................................................................................................. 10 T EST DATA: OCCUPIED BANDWIDTH MEASUREMENT TABLE ........................................................................................ 11 T EST DATA: 9.25 GHZ 99% OBW PLOT ............................................................................................................ 12 EMISSION MASK ............................................................................................................................................. 13 T EST DATA: MASK B, 9.2 GHZ ......................................................................................................................... 14 T EST DATA: MASK B, 9.25 GHZ ....................................................................................................................... 15 T EST DATA: MASK B, 9.3 GHZ ......................................................................................................................... 16 SPURIOUS EMISSIONS AT ANTENNA TERMINAL (CONDUCTED) ...................................................................... 17 T EST DATA: 9.2 GHZ, 2 ND HARMONIC................................................................................................................. 18 T EST DATA: 9.2 GHZ, 3 RD HARMONIC ................................................................................................................. 19 T EST DATA: 9.2 GHZ, 4 TH HARMONIC ................................................................................................................. 20 T EST DATA: 9.25 GHZ, 2 ND HARMONIC ............................................................................................................... 21 T EST DATA: 9.25 GHZ, 3 RD HARMONIC ............................................................................................................... 22 T EST DATA: 9.25 GHZ, 4 TH HARMONIC ............................................................................................................... 23 T EST DATA: 9.3 GHZ, 2 ND HARMONIC................................................................................................................. 24 T EST DATA: 9.3 GHZ, 3 RD HARMONIC ................................................................................................................. 25 T EST DATA: 9.3 GHZ, 4 TH HARMONIC ................................................................................................................. 26 FIELD STRENGTH OF SPURIOUS EMISSIONS ................................................................................................... 27 T EST DATA: 9.2 GHZ, RADIATED SPURIOUS EMISSIONS .......................................................................................... 29 T EST DATA: 9.25 GHZ, RADIATED SPURIOUS EMISSIONS ......................................................................................... 30 T EST DATA: 9.3 GHZ, RADIATED SPURIOUS EMISSIONS .......................................................................................... 31 FREQUENCY STABILITY ................................................................................................................................... 29 STATEMENT OF MEASUREMENT UNCERTAINTY ................................................................................................ 33 EMC EQUIPMENT LIST ..................................................................................................................................... 34 Applicant: Guidance Marine Limited FCC ID: VYMRAD-1100 Report: 325UT20_PT80 Radar TestReport_Rev2 Page 2 of 34 SIGNATURE PAGE Timco Engineering, Inc. attests that: ☒ The EUT tested herein fulfills all approval requirements and/or the customer requirements as identified in this test report. ☐ The EUT tested herein does not fulfill all approval requirements and/or the customer requirements as identifi…
Text truncated - open the document above for the full version.
Applicant: Guidance Marine Limited FCC ID: VYMRAD-1100 Conducted Measurements TEST SETUP PHOTOGRAPHS Radiated Measurements: Table Setup TEST SETUP PHOTOGRAPHS Field Strength of Spurious Emissions 30 MHz to 200 MHz (Biconical Antenna) TEST SETUP PHOTOGRAPHS Field Strength of Spurious Emissions 200 MHz to 1 GHz (Log Periodic Antenna) TEST SETUP PHOTOGRAPHS Field Strength of Spurious Emissions 1 – 18 GHz (Dual Ridge Waveguide Antenna) TEST SETUP PHOTOGRAPHS Field Strength of Spurious Emissions > 18 GHz (Double Ridge Horn Antenna)
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 80 | 9.20 GHz - 9.30 GHz | 2.50 mW | 131MP0N | Amp |

RangeGuard Wide Beam 20-0183-1
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
MINI RESPONDER
Equipment Class
MRD - Marine Radar
RADASCAN
Equipment Class
MRD - Marine Radar