
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER MANUAL Contents PREFACE Trademarks FCC Compliance Copyright Statement ID‐A100 Introduction Features Hardware LED Indicators Data Connections Antennas Orientation Environmental Limits CUSTOMER SERVICE airPointe Customer Support USER MANUAL PREFACE Trademarks airPointe of New Hampshire and the airPointe of New Hampshire logo are trademarks of airPointe of New Hampshire. All other product names are copyright and registered trademarks or trade names of their respective owners. Information in this document is provided solely to enable system and software implementers to use the airPointe of New Hampshire system. There are no express or implied copyright licenses granted hereunder to design or fabricate any integrated circuits or integrated circuits based on the information in this document. airPointe of New Hampshire reserves the right to make changes without further notice to any products herein. airPointe of New Hampshire makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does airPointe of New Hampshire assume any liability arising out of the application or use of any product, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. The user of this system is cautioned that any changes or modifications to this system, not expressly approved by airPointe of New Hampshire could void the warranty. FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: ‐‐Reorient or relocate the receiving antenna. ‐‐Increase the separation between the equipment and receiver. ‐‐Connect the equipment into an outlet on a circuit different from that which the receiver is connected. ‐‐Consult the dealer or an experienced radio/TV technician for help. ‐‐Changes or modifications not expressly approved by airPointe of New Hampshire could void the user’s authority to operate the equipment USER MANUAL “WARNING! FCC Radiation Exposure Statement: This portable equipment with its antenna complies with FCC’s RF radiation exposure limits set forth for an uncontrolled environment. To maintain compliance follow the instructions below: 1. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. Avoid direct contact to the antenna, or keep contact to a minimum while using this equipment.” This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. PREFACE COPYRIGHT STATEMENT Copyright © 2009 airPointe of New Hampshire. All Rights Reserved. This document, as well as the hardware and firmware described therein, are furnished under license and may only be used or copied in accordance with the terms of such license. The information in these pages are furnished for informational use only, are subject to change without notice, and should not be construed as a commitment by airPointe of New Hampshire, airPointe of New Hampshire assumes no responsibility or liability for any errors or inaccuracies that may appear in these pages. Every effort has been made to supply complete and accurate information. However, airPointe of New Hampshire assumes no responsibility for its use, or for any infringements of patents or other rights of third parties, which would result. airPointe of New Hampshire 35E Industrial Way Suite 101 Rochester, NH 03867 USER MANUAL ID‐A100 INTRODUCTION airPointe delivers software and hardware solutions that enable healthcare organizations to streamline operations, improve quality‐of‐care, reduce costs and generate additional revenue. airPointe develops an innovative next generation Intelligent Real‐Time Location System (i‐RTLS) which can gather data on high‐value assets within an organization, including medical equipment, clinical staff, patients and visitors. An active tag is placed on an item or person that requires monitoring. The battery powered active tags can transmit and receive information throughout a secure wireless router network. Information, or data, that is intelligently and automatically collected from each tag will identify the asset type, the location, movement timestamp and other desired device attributes. This data allows items to be easily located anywhere within the wireless network, as well as their proximity relationship to each other. FEATURES ‐ Battery life of 4 years ‐ Hermetically sealed ‐ Programmable interface ‐ Auto‐hopping USER MANUAL ‐ Small form factor HARDWARE The tags are incased in a 3 3/16” x 2 5/16” x 5/16 (8cm x 5.8cm x .8cm) UL rated ABS Cellcore plastic housing and contain the internal components of a RF transmitter and battery source. LED Indicators None on this model Data Connections Internal, all programming will be done at airPointe. ID‐A100 Antennas Internal. ORIENTATION When possible, the tags should be placed on assets in the highest least obstructive manner. This will optimize the readers’ ability to receive the most accurate data from the tag. ENVIRONMENTAL LIMITS Humidity: Submersible in water (hermetically sealed) Temperature: 0° C to 70°C If device i…
Text truncated - open the document above for the full version.
1.0 Product Data Makrofol PCVM Description Makrofol PCVM is a clear, translucent polycarbonatefilm with a first surface velvet and a second surface matte. Makrofol PCVM comes in thickness from .005”-.020”. Applications: Automotive Instrument Panels and Displays, Control Panels, Nameplates, Labels, Dials, and Scales. Disclaimer The manner in which you use and the purpose to which you put and utilize our products, technical assistance and information (whether verbal, written or by way of production evaluations), including any suggested formulations and recommendations are beyond our control. Therefore, it is imperative that you test our products, technical assistance and information to determine to your own satisfaction whether they are suitable for your intended uses and applications. This application-specific analysis must at least include testing to determine suitability from a technical as well as health, safety, and environmental standpoint. Such testing has not necessarily been done by us. Unless we otherwise agree in writing, all products are sold strictly pursuant to the terms of our standard conditions of sale. All information and technical assistance is given without warranty or guarantee and is subject to change without notice. It is expressly understood and agreed that you assume and hereby expressly release us from all liability, in tort, contract or otherwise, incurred in connection with the use of our products, technical assistance, and information. Any statement or recommendation not contained herein is unauthorized and shall not bind us. Nothing herein shall be construed as a recommendation to use any product in conflict with patents covering any material or its use. No license is implied or in fact granted under the claims of any patent. Product Data Makrofol PCVM For additional information please call Bayer Films Americas Customer Service at: 866-659-9023 Velvet/Matte ©Copyright, Bayer Films Americas, 2004 Printed in USA MAKROFOL® is a registered trademark of Bayer Corp. 245 New Park Drive Berlin, CT 06037 Phone: 866-659-9023 Fax: 877-229-3702 www.bayerfilms.com [email protected] 1.0 Product Data Makrofol PCVM Description Makrofol PCVM is a clear, translucent polycarbonatefilm with a first surface velvet and a second surface matte. Makrofol PCVM comes in thickness from .005”-.020”. Applications: Automotive Instrument Panels and Displays, Control Panels, Nameplates, Labels, Dials, and Scales. Disclaimer The manner in which you use and the purpose to which you put and utilize our products, technical assistance and information (whether verbal, written or by way of production evaluations), including any suggested formulations and recommendations are beyond our control. Therefore, it is imperative that you test our products, technical assistance and information to determine to your own satisfaction whether they are suitable for your intended uses and applications. This application-specific analysis must at least include testing to determine suitability from a technical as well as health, safety, and environmental standpoint. Such testing has not necessarily been done by us. Unless we otherwise agree in writing, all products are sold strictly pursuant to the terms of our standard conditions of sale. All information and technical assistance is given without warranty or guarantee and is subject to change without notice. It is expressly understood and agreed that you assume and hereby expressly release us from all liability, in tort, contract or otherwise, incurred in connection with the use of our products, technical assistance, and information. Any statement or recommendation not contained herein is unauthorized and shall not bind us. Nothing herein shall be construed as a recommendation to use any product in conflict with patents covering any material or its use. No license is implied or in fact granted under the claims of any patent. Product Data Makrofol PCVM For additional information please call Bayer Films Americas Customer Service at: 866-659-9023 Velvet/Matte ©Copyright, Bayer Films Americas, 2004 Printed in USA MAKROFOL® is a registered trademark of Bayer Corp. 245 New Park Drive Berlin, CT 06037 Phone: 866-659-9023 Fax: 877-229-3702 www.bayerfilms.com [email protected]
Curtis-Straus LLC is accredited to ISO/IEC 17025 by A2LA for the specific scope of accreditation under Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation. Any opinions or interpretations expressed in this report are outside the scope of our A2LA accreditation as A2LA only accredits testing. ____________________________________________________________ Curtis-Straus • •• • 527 Great Road • •• • Littleton, MA • •• • TEL (978) 486-8880 • •• • FAX (978) 486-8828 page 1 of 18 Test Report Report No EI1289-2 Client AirPointe of New Hampshire 35E Industrial Way, Suite 101 Rochester, NH 03867 Phone 603-994-2200 FRN 0018228197 Model ID-A100 FCC ID WUS00022 Equipment Type Equipment Code Part 15 Security/Remote Control Transmitter DSC Results As detailed within this report Prepared by Evan Gould – Compliance Engineer Authorized by Mairaj Hussain – EMC Supervisor Issue Date March 18, 2009 Conditions of Issue This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’ section on page 17 of this report. Test Report for AirPointe of New Hampshire • •• • Report No. EI1289-2 March 18, 2009 ______________________________________________________________________ ____________________________________________________________ Curtis-Straus • •• • 527 Great Road • •• • Littleton, MA • •• • TEL (978) 486-8880 • •• • FAX (978) 486-8828 page 2 of 18 Contents Summary.................................................................................................................................3 Test Methodology ....................................................................................................................3 Product Tested - Configuration Documentation .......................................................................4 Fundamental Emission ............................................................................................................5 Bandwidth ...............................................................................................................................6 Harmonics and Spurious Emissions ........................................................................................8 Duty Cycle Correction Factor...................................................................................................9 Measurement Uncertainty......................................................................................................11 Test Equipment Used ............................................................................................................12 Conditions Of Testing ............................................................................................................17 Test Report for AirPointe of New Hampshire • •• • Report No. EI1289-2 March 18, 2009 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus • •• • 527 Great Road • •• • Littleton, MA • •• • TEL (978) 486-8880 • •• • FAX (978) 486-8828 page 3 of 18 Summary This test report supports an application for certification of a transmitter operating pursuant to 47 CFR 15.231(e). The product is the airPointe Low Profile Asset Tag. It’s operating frequency range is 300.5-346.5MHz. It is coin cell battery powered. The manufacturer is setting the power levels for five different frequency ranges as follows: 300.5 – 302.5MHz -3 dBm setting 303.5 – 307.5MHz -4.3 dBm 308.5 – 311.5MHz -1 dBm 312.5 – 320.5MHz +3.1 dBm 336.5 – 346.5MHz +10 dBm The frequencies between 320.5 and 336.5MHz are not used. Test Methodology Testing was performed according to ANSI C63.4-2003. Radiated emissions were maximized by rotating the device around three orthogonal axes, as well as varying the test antenna’s height and polarity. Fresh batteries were used for testing. Frequency range investigated: 30MHz – 3.5GHz Measurement distance: 0.15-30MHz Conducted 30-3500MHz 3m The receiver portion of this device is subject to the Verification authorization procedure as per 15.101(b). The associated digital circuitry is also subject to the Verification authorization procedure as per 15.101(a). A separate test report has been issued to AirPointe of New Hampshire in order to cover both of these requirements. Test Report for AirPointe of New Hampshire • •• • Report No. EI1289-2 March 18, 2009 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus • •• • 527 Great Road • •• • Littleton, MA • •• • TEL (978) 486-8880 • •• • FAX (978) 486-8828 page 4 of 18 Product Tested - Configuration Documentation EUT Configuration Work Order: I1289 Company: AirPointe of New Hampshire Company Address: 35E Industrial Way Rochester, NH 03867 Contact: Bob Duggan Person Present: Bob Duggan MNPNSN EUT: ID-A100- EUT Description: airPointe Low Profile Asset Tag EUT TX Frequencies: 300.5-346.5MHz Support Equipment: MNSN None EUT Ports: Port LabelPort TypeNo. of ports No. PopulatedCable TypeShieldedFerritesLength Max LengthUnpopulated Reason None Software / Operating Mode Description: EUT operating in either TX mode, or RX mode. Test Report for AirPointe of New Hampshire • •• • Report No. EI1289-2 March 18, 2009 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus • •• • 527 Great Road • •• • Littleton, MA • •• • TEL (978) 486-8880 • •• • FAX (978) 486-8828 page 5 of 18 Fundamental Emission LIMIT Fundamental Frequency Field Strength of Fundamental (microvolts/meter) Field Strength of Spurious Emission (microvolts/meter) 260 - 470 MHz 1,500 to 5,000 150 to 500 [15.231(e)] Average Limit[dBμV/m] = 20log((16.6667(F[in MHz]) – 2833.3333) @ 3m Example Calculation: 20log((16.6667(302.5) – 2833.3333) = 66.8dBμV/m @ 3m MEASUREMENT Radiated Fundamental Emissions Table Curtis-Straus LLC Curtis-Straus LLC Curtis-Straus …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15.231(e) | 336.5 MHz - 346.5 MHz | - |

Security/Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Active RFID Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Active RFID Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Active RFID Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Active RFID Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter