FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Proware Technologies Co Ltd./
  3. WWMDN523V1

WWMDN523V1Wireless N USB Adapter

Proware Technologies Co Ltd.
Wireless N USB Adapter - FCC ID WWMDN523V1 - Proware Technologies Co Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 19, 2010
Application Purpose
Original Equipment
Date of Application
May 13, 2010
Equipment Note
Wireless N USB Adapter
Frequency Range
2422.00000000 - 2452.00000000
Company
Proware Technologies Co Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

M-WN823N Wireless N USB Adapter Rev: 1.0.0 1910020263 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of PROWARE TECHNOLOGIES CO., LTD. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from PROWARE TECHNOLOGIES CO., LTD. Copyright © 2010 PROWARE TECHNOLOGIES CO., LTD. All rights reserved. http://www.proware.com.cn FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC RF Radiation Exposure Statement: This device has been tested for compliance with FCC RF Exposure (SAR) limits in the typical laptop computer configuration and this device can be used in desktop or laptop computers with side mounted PCMCIA slots. This device cannot be used with handheld PDAs (personal digital assistants). This device and its antenna must not be co-located or operated in conjunction with any other antenna or transmitter. CE Mark Warning This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. National restrictions This device is intended for home and office use in all EU countries (and other countries following the EU directive 1999/5/EC) without any limitation except for the countries mentioned below: Country Restriction Reason/remark Bulgaria None General authorization required for outdoor use and public service France Outdoor use limited to 10 mW e.i.r.p. within the band 2454-2483.5 MHz Military Radiolocation use. Refarming of the 2.4 GHz band has been ongoing in recent years to allow current relaxed regulation. Full implementation planned 2012 Italy None If used outside of own premises, general authorization is required Luxembourg None General authorization required for network and service supply(not for spectrum) Norway Implemented This subsection does not apply for the geographical area within a radius of 20 km from the centre of Ny-Ålesund Russian Federation None Only for indoor applications Note: Please don’t use the product outdoors in France. CONTENTS Package Contents .................................................................................................... 1 Chapter 1 Introduction ......................................................................................... 2 1.1 Overview of the Product ........................................................................................ 2 1.2 Features ................................................................................................................ 2 1.3 LED Status ............................................................................................................ 3 Chapter 2 Installation Guide ................................................................................ 4 2.1 Hardware Installation............................................................................................. 4 2.2 Software Installation .............................................................................................. 4 2.2.1 Overview ................................................................................................ 4 2.2.2 Software Installation for Windows XP .................................................... 4 2.2.3 Software Installation for Windows Vista ................................................. 8 Chapter 3 Configuration..................................................................................... 13 3.1 General Status .................................................................................................... 13 3.2 Profile Management............................................................................................ 14 3.2.1 Add or Edit a Configuration Profile ....................................................... 15 3.2.2 Remove a configuration profile............................................................. 20 3.2.3 Duplicate a configuration file ................................................................ 21 3.2.4 Set default configuration profile............................................................ 21 3.3 Available Network................................................................................................ 21 3.4 Status..................................................................................................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

PROWARE TECHNOLOGIES CO., LTD. AGENCY AUTHORIZATION LETTER FCC ID:WWMDN523V1 Date:April,12,2010 To whom it may concern: We, the undersigned, hereby authorize Audix Technology (Shenzhen) Co., Ltd (No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park,Nantou,Shenzhen, Guangdong, China)to act on our behalf, as our agent, in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification. Any act carried out by Audix within the scope of this authorization shall have the same effects as our own. This authorization shall expire 6 months form original date. If you have any Questions regarding the authorization, please don’t hesitate to contact us. Thank you. Sincerely, Name of authorized signer: Yongquan Wang Title of authorized signer: Product Dept. Manager Company Name: PROWARE Technologies Co., Ltd. Tel: 86-755-26525554 Fax: 86-755-26508930 Web site:WWW.PROWARE.COM.CN

Cover Letter(s)

PROWARE TECHNOLOGIES CO., LTD. Date: April,12,2010 Communications Commission Authorization and Evaluation Division FCC ID: WWMDN523V1 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this application as outlined below: 1. Block diagram 2. Schematics 3. Operation Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might to harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the grant for this application. Sincerely, Name of authorized signer: Yongquan Wang Title of authorized signer: Product Dept. Manager Company Name: PROWARE Technologies Co., Ltd. Tel: 86-755-26525554 Fax: 86-755-26508930 Web site: WWW.PROWARE.COM.CN

Cover Letter(s)

PROWARE TECHNOLOGIES CO., LTD. Attestation for FCC Declaration of Conformity FCC ID: WWMDN523V1 Date: 2010-04-23 Please be notified that we, the undersigned, Proware Technologies Co Ltd., LTD declare that the product bears the above FCC ID is also complying with the requirements of FCC DoC. The test report number for FCC DoC is EM-F990340, with is issued by an accredited lab, Audix Technology Corporation, EMC Department located at No. 53-11, Tin-Fu Tsun, Lin-Kou , Taipei Hsien , Taiwan. Which has been accredited in accordance to all of the requirements of 47CFR 2.948(d) and (e) of the FCC rules and KDB349827. Sincerely, Name of authorized signer: Yongquan Wang Title of authorized signer: Product Dept. Manager Company Name: PROWARE Technologies Co., Ltd. Tel: 86-755-26525554 Fax: 86-755-26508930 Web site: WWW.PROWARE.COM.CN

External Photos

FCC ID:WWMDN523V1 Page 13-1 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F10074 13. PHOTOGRAPH OF EUT Figure 1 General Appearance of the EUT Figure 2 General Appearance of the EUT

ID Label/Location Info

白色 PANTONE 426C 白色 王晓锋 1 2 E D C B A 1 2 3 4 5 6 7 8 9 E D C 3 4 5 6 7 8 B A 9 料号: 设 计 审 核 颜 色 名 称 版 本 材 质 模 具 机型版本号 完成日期 logo 底色 文字 其它 记 录 与上一版的区别 MU3-WN823N盒体标贴 第一版 100#合成纸+雾膜 MU3-WN823N\1.0\欧 2009-08-5 认证需求而改的FCC ID M-WN823N FCC ID: WWMDN523V1 M-WN823N FCC ID: WWMDN523V1 白色 PANTONE 426C 白色 王晓锋 1 2 E D C B A 1 2 3 4 5 6 7 8 9 E D C 3 4 5 6 7 8 B A 9 料号: 设 计 审 核 颜 色 名 称 版 本 材 质 模 具 机型版本号 完成日期 logo 底色 文字 其它 记 录 与上一版的区别 PW-DN523盒体标贴 第一版 100#合成纸+雾膜 PW-DN523\1.0\欧 2009-08-5 认证需求而改的FCC ID PW-DN523 FCC ID: WWMDN523V1 PW-DN523 FCC ID: WWMDN523V1 Label Location

Internal Photos

FCC ID:WWMDN523V1 Page 13-2 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F10074 Figure 3 General Appearance of the EUT Figure 4 Inside of the EUT FCC ID:WWMDN523V1 Page 13-3 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F10074 Figure 5 Inside of the EUT Figure 6 Inside of the EUT FCC ID:WWMDN523V1 Page 13-4 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F10074 Figure 7 Inside of the EUT

RF Exposure Info

Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 1/26 Issue: A Date: 2009/10/06 1 COMOSAR E-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 2/26 Issue: A Date: 2009/10/06 2 COMOSAR SEPT ISOTROPIC E-FIELD PROBE CALIBRATION REPORT DATE: 12/02/2009 REFERENCE: SN 37/08 EP80 OBJECT: COMOSAR SEPT ISOTROPIC E-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 37/08 EP80 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 06/10/2009 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 3/26 Issue: A Date: 2009/10/06 3 PRODUCT DESCRIPTION Frequency Range 100 MHz - 30 GHz Probe length 330 mm Length of one dipole 4.5 mm Maximum external diameter 8 mm Probe extremity diameter 6.5 mm Distance between dipoles/probe extremity < 2.7 mm Resistance of the three dipole (at the connector) Dipole 1: R1=1.4382 MΩ Dipole 2: R2=1.4894 MΩ Dipole 3: R3=1.4683 MΩ Connector (HIROSE series SR30) 6 wire male (Hirose SR30series) The probe could be checked by measuring the resistance of the three dipoles. CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Calibration bench CALISAR Multimeter Keithley 2000 Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 4/26 Issue: A Date: 2009/10/06 4 MEASUREMENT PROCEDURE Probe calibration is realized, in compliance with CENELEC EN 50361 and IEEE 1528 std, with CALISAR, Antennessa proprietary calibration system. The calibration is performed with the EN 50361 annexe technique using reference guide at the five frequencies. Where : P fw = Forward Power P bw = Backward Power a and b = Waveguide dimensions  = Skin depth Keithley configuration: Rate = Medium; Filter =ON; RDGS=10; FILTER TYPE =MOVING AVERAGE; RANGE AUTO After each calibration, a SAR measurement is performed on a validation dipole and compared with a NPL calibrated probe, to verify it. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 5/26 Issue: A Date: 2009/10/06 5 PROBE UNCERTAINTIES Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 6/26 Issue: A Date: 2009/10/06 6 1. Calibration at 450.00 MHz A. Calibration parameters. Label GSM450 Epsilon 43.33 Sigma 0.84 S/m Temperature 21°C Antenna gain 2.03 dB Antenna S11 -10.50 dB Low limit detection (CW) 0.72 V/m (0.47 mW/kg) Calibration curves ei=f(V) (i=1,2,3) allow to obtain E-field value using the formula: 2 3 2 2 2 1 **EEEE= The following tables represent the calibration curves linearization by curve segment in CW signal. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 7/26 Issue: A Date: 2009/10/06 7 Calibration coefficients for the three dipoles in CW: v1 e1 v2 e2 v3 e3 0.584004 419.557857 -0.696059 435.622023 0.541191 412.830715 0.467833 339.207465 -0.556278 351.381991 0.469757 336.297240 0.376994 276.348283 -0.452232 288.647980 0.378826 274.224190 0.302778 224.954643 -0.359005 232.397390 0.305842 224.365698 0.241038 182.154071 -0.286978 188.889931 0.246562 183.825274 0.192549 148.484090 -0.230386 154.650994 0.195712 148.993075 0.154033 121.674762 -0.185412 127.378480 0.157543 122.783107 0.123397 100.276479 -0.147311 104.193802 0.125866 100.956090 0.099878 83.770361 -0.118637 86.660489 0.101471 84.063863 0.081165 70.553219 -0.095250 72.263937 0.082289 70.694342 0.065166 59.152028 -0.076788 60.795323 0.066427 59.538957 0.051916 49.592416 -0.061280 51.041514 0.053353 50.232492 0.041968 42.297602 -0.048746 43.022565 0.042906 42.675214 0.033724 36.126757 -0.039149 36.748110 0.034686 36.605243 0.021855 26.962568 -0.024798 27.024723 0.022272 27.149463 0.018405 23.975145 -0.020856 24.085809 0.018755 24.141334 0.015467 21.515985 -0.017534 21.515985 0.015767 21.615299 0.013018 19.309065 -0.014750 19.398191 0.013276 19.487731 0.010938 17.408496 -0.012392 17.529166 0.011157 17.569575 0.009022 15.586953 -0.010228 15.658899 0.009215 15.676938 0.007353 13.956010 -0.008328 13.988181 0.007484 14.020428 0.005989 12.466979 -0.006801 12.495719 0.006111 12.567858 0.004890 11.214019 -0.005573 11.265779 0.005003 11.330818 0.004019 10.133541 -0.004570 10.121882 0.004099 10.168601 0.003279 9.094132 -0.003739 9.157170 0.003352 9.125596 0.002660 8.095827 -0.003041 8.293946 0.002769 8.265350 0.002126 7.324219 -0.002453 7.366500 0.002188 7.358024 0.001685 6.565400 -0.001947 6.580536 0.001724 6.542765 0.001300 5.784440 -0.001511 5.718225 0.001334 5.757862 0.001123 5.245191 -0.001307 5.269400 0.001174 5.275471 0.000891 4.701768 -0.001057 4.723470 0.000924 4.728912 0.000704 4.209798 -0.000850 4.226839 0.000736 4.243862 0.000574 3.790376 -0.000689 3.791428 0.000603 3.830551 0.000457 3.396200 -0.000570 3.434303 0.000483 3.421852 0.000365 3.050686 -0.000463 3.078014 0.000389 3.079630 0.000292 2.745766 -0.000369 2.726866 0.000311 2.759206 0.000236 2.486639 -0.000312 2.489933 0.000246 2.460514 0.0001…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: SZ10040031S01 Page 2 of 145 Contents 1. GENERAL INFORMATION....................................................................................................4 1.1. Notes.........................................................................................................................................4 1.2. Organization item....................................................................................................................4 1.3. Conclusion................................................................................................................................4 2. TESTING LABORATORY.......................................................................................................5 2.1. Identification of the Responsible Testing Laboratory..........................................................5 2.2. Identification of the Responsible Testing Location..............................................................5 2.3. Accreditation Certificate........................................................................................................5 2.4. List of Test Equipments..........................................................................................................5 3. TECHNICAL INFORMATION ...............................................................................................6 3.1. Identification of Applicant......................................................................................................6 3.2. Identification of Manufacturer..............................................................................................6 3.3. Equipment Under Test (EUT)................................................................................................6 3.3.1. Photographs of the EUT..................................................................................................7 3.3.2. Identification of all used EUTs........................................................................................7 4. TEST RESULTS.........................................................................................................................7 4.1. Applied Reference Documents...............................................................................................7 4.2. Test Environment/Conditions................................................................................................8 4.3. Operational Conditions During Test.....................................................................................9 4.3.1. Informations On The Testing..........................................................................................9 4.3.2. The Measurement System.............................................................................................10 4.3.3. Uncertainty Assessment.................................................................................................12 4.3.4. Equipments and results of validation testing...............................................................13 4.3.5. Dielectric Performance..................................................................................................14 4.3.6. Simulant liquids..............................................................................................................15 4.4. SAR Limits.............................................................................................................................15 4.5. Items used in the Test Results List.......................................................................................16 4.6. Test Results List.....................................................................................................................17 ANNEX A ACCREDITATION CERTIFICATE................................................................20 ANNEX B PHOTOGRAPHS OF THE EUT......................................................................21 Report No.: SZ10040031S01 Page 3 of 145 ANNEX C GRAPH TEST RESULTS .................................................................................24 Report No.: SZ10040031S01 Page 5 of 145 2. Testing Laboratory 2.1. Identification of the Responsible Testing Laboratory Company Name: Shenzhen Electronic Product Quality Testing Center Department: Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China Responsible Test Lab Manager: Mr. Shu Luan Telephone: +86 755 86130268 Facsimile: +86 755 86130218 2.2. Identification of the Responsible Testing Location Name: Shenzhen Electronic Product Quality Testing Center Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China 2.3. Accreditation Certificate Accredited Testing Laboratory: No. CNAS L1659 (see Annex A) 2.4. List of Test Equipments No. Instrument Type 1 PC Dell (Pentium IV 2.4GHz, SN:X10-23533) 2 Network Emulator Rohde&Schwarz (CMU200, SN:105894) 3 Voltmeter Keithley (2000, SN:1000572) 4 Synthetizer Rohde&Schwarz (SML_03, SN:101868) 5 Amplifier Nucludes (ALB216, SN:10800) 6 Power Meter Rohde&Schwarz (NRVD, SN:101066) 7 Probe Antennessa (SN:SN_3708_EP80) 8 Phantom Antennessa (SN:SN_36_08_SAM62) 9 Liquid Antennessa (Last Calibration:21 08 04) Report No.: SZ10040031S01 Page 6 of 145 3. Technical Information Note: the following data is based on the information by the applicant. 3.1. Identification of Applicant Company Name: Proware Technologies Co., Ltd. Address: 4/F,Building 7,Section 2, Honghualing Industrial Park, Xili, Nanshan District, Shenzhen, P.R.C. 3.2. Identification of Manufacturer Company Name: Proware Technologies Co., Ltd. Address: 4/F,Building 7,Section 2, Honghualing Industrial Park, Xili, Nanshan District, Shenzhen, P.R.C. 3.3. Equipment Under Test (EUT) Brand Name: PROWARE Type Name: PROWARE Marking Name: WWMDN523V1 Hardware Version: 1.0 Software Version: (n.a) Frequency Bands: WIFI 802.11 b/g/n data rate: 802.11b: 11/ 5.5/ 2/ 1Mbps 802.11g: 54/ 48/ 36/ 24…

Text truncated - open the document above for the full version.

Test Report

FCC ID:WWMDN523V1 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F10074 APPLICATION FOR CERTIFICATION On Behalf of Proware Technologies Co., Ltd. Wireless N USB Adapter Model Number: M-WN823N; PW-DN523 FCC ID: WWMDN523V1 Prepared for : Proware Technologies Co., Ltd. 4/F, Building 7, Section 2, Honghualing Industrial Park, Xili, Nanshan District, Shenzhen, P.R.C. Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park, Nantou, Shenzhen, Guangdong, China Tel: (0755) 26639496 Report Number : ACS-F10074 Date of Test : Mar.27~Apr.03, 2010 Date of Report : Apr.13, 2010 FCC ID:WWMDN523V1 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F10074 TABLE OF CONTENTS Description Page 1. SUMMARY OF STANDARDS AND RESULTS................................................................... 1-1 1.1. Description of Standards and Results ............................................................................................1-1 2. GENERAL INFORMATION .................................................................................................. 2-1 2.1. Description of Device (EUT) .........................................................................................................2-1 2.2. Test information .............................................................................................................................2-2 2.3. Tested Supporting System Details .................................................................................................2-3 2.4. Test Facility ...................................................................................................................................2-3 2.5. Measurement Uncertainty (95% confidence levels, k=2) ..............................................................2-4 3. POWER LINE CONDUCTED EMISSION TEST ................................................................ 3-1 3.1. Test Equipments.............................................................................................................................3-1 3.2. Block Diagram of Test Setup .........................................................................................................3-1 3.3. Power Line Conducted Emission Test Limits................................................................................3-1 3.4. Configuration of EUT on Test .......................................................................................................3-1 3.5. Operating Condition of EUT..........................................................................................................3-2 3.6. Test Procedure................................................................................................................................3-2 3.7. Power Line Conducted Emission Test Results ..............................................................................3-2 4. RADIATED EMISSION TEST ............................................................................................... 4-1 4.1. Test Equipment ..............................................................................................................................4-1 4.2. Block Diagram of Test Setup .........................................................................................................4-1 4.3. Radiated Emission Limit................................................................................................................4-2 4.4. EUT Configuration on Test............................................................................................................4-3 4.5. Operating Condition of EUT..........................................................................................................4-3 4.6. Test Procedure................................................................................................................................4-3 4.7. Radiated Emission Test Results .....................................................................................................4-4 5. CONDUCTED SPURIOUS EMISSIONS............................................................................... 5-1 5.1. Test Equipment ..............................................................................................................................5-1 5.2. Limit...............................................................................................................................................5-1 5.3. Test Procedure................................................................................................................................5-1 5.4. Test result .......................................................................................................................................5-1 6. BAND EDGE COMPLIANCE TEST ..................................................................................... 6-1 6.1. Test Equipment ..............................................................................................................................6-1 6.2. Limit...............................................................................................................................................6-1 6.3. Test Produce ...................................................................................................................................6-1 6.4. Test Results ....................................................................................................................................6-1 7. 6dB Bandwidth Test.................................................................................................................. 7-1 7.1. Test Equipment ..............................................................................................................................7-1 7.2. Limit...............................................................................................................................................7-1 7.3. Test Procedure.............…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: SZ10040031S01 Page 21 of 115 Annex B Photographs of the EUT 1 EUT Horizontal-Up 2 EUT Horizontal-Down Report No.: SZ10040031S01 Page 22 of 115 3 EUT Vertical-Front 4 EUT Vertical-Back Report No.: SZ10040031S01 Page 23 of 115 5 Data line

Test Setup Photos

FCC ID:WWMDN523V1 Page 12-1 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F10074 12. PHOTOGRAPH OF TEST 12.1.Photos of Power Line Conducted Emission Test FCC ID:WWMDN523V1 Page 12-2 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F10074 12.2.Photos of Radiated Emission Test 30-1000MHz FCC ID:WWMDN523V1 Page 12-3 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F10074 (Above 1000MHz)

Contact Information

Applicant

Yongquan Wang(Product Dept. Manager)
[email protected]+86-755-26508263Fax: +86-755-26508930

Technical Contact

AUDIX Technology (Shenzhen) Co., Ltd.Ken Lu
[email protected]86-755-26639497

52 Block Shenzhen Science&Industry · Shenzhen · China

Non-Technical Contact

AUDIX Technology (Shenzhen) Co., Ltd.Kris Zheng
[email protected]86-755-26639497

Test Firm

Audix Technology (Shenzhen) Co.Smart Tsai
[email protected]86-755-663-9495Fax: 86-755-663-2877

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.42 GHz - 2.45 GHz78.00 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is the conducted output power. Device is an 802.11b/g/n USB device as described in this filing. End-users must be provided with operating and installation instructions to ensure RF exposure compliance. End-users must be informed of the operating requirements for satisfying body RF exposure compliance. The highest reported body SAR is: 0.266 W/kg.

Other Applications from Proware Technologies Co Ltd.

150Mbps Wireless N USB Module - FCC ID WWMMN427V3 - Proware Technologies Co Ltd.
WWMMN427V3

150Mbps Wireless N USB Module

Jul 21, 2014

Equipment Class

DTS - Digital Transmission System
Wireless Lite-N USB Module - FCC ID WWMMN421V2 - Proware Technologies Co Ltd.
WWMMN421V2

Wireless Lite-N USB Module

May 07, 2013

Equipment Class

DTS - Digital Transmission System
150Mbps Wireless N USB Module - FCC ID WWMMN42756IV2 - Proware Technologies Co Ltd.
WWMMN42756IV2

150Mbps Wireless N USB Module

May 01, 2013

Equipment Class

DTS - Digital Transmission System
3G Wireless N Nano Router - FCC ID WWM3G401MV1 - Proware Technologies Co Ltd.
WWM3G401MV1

3G Wireless N Nano Router

Dec 28, 2012

Equipment Class

DTS - Digital Transmission System
300Mbps Wireless N USB Module - FCC ID WWMMN527V1 - Proware Technologies Co Ltd.
WWMMN527V1

300Mbps Wireless N USB Module

Nov 20, 2012

Equipment Class

DTS - Digital Transmission System