FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Alltek Marine Electronics Corporation/
  3. WZ7ATON-301-303

WZ7ATON-301-303AIS AtoN (Aids-to-Navigation)

Alltek Marine Electronics Corporation
AIS AtoN (Aids-to-Navigation) - FCC ID WZ7ATON-301-303 - Alltek Marine Electronics Corporation
Click to zoom

Application Details

Equipment Class
AIS - Automatic Identification Systems
Date of Grant
Jun 17, 2012
Application Purpose
Original Equipment
Date of Application
Apr 11, 2012
Equipment Note
AIS AtoN (Aids-to-Navigation)
Frequency Range
156.02500000 - 162.02500000
Company
Alltek Marine Electronics Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

I COPYRIGHT The entire contents of this manual, including any future updates, revisions, and modifications to specifications, shall remain the property of Alltek Marine Electronics Corp. (hereinafter AMEC) at all times. Unauthorized copies or reproductions of this manual, either in part or as a whole, are strictly prohibited. The contents herein can only be used for the purpose subjects to this manual. DISCLAIMER AMEC is devoted in publishing and maintaining this manual. As we continue to improve our Aids to Navigation Automatic Identification System (AIS AtoN) products, information in this manual is subjected to changes without notice. AMEC does not make any representations or warranties (implied or otherwise) regarding the accuracy and completeness of this manual and shall in no event be liable for any loss of profit or any commercial damage, including but not limited to special, incidental, consequential, or other damages. CONTACT US AT: Technical Support: Sales & Marketing: ALLTEK MARINE ELECTRONICS CO., LTD 7F, NO. 605, Ruei-Guang RD., Neihu, Taipei, Taiwan 114 TEL: +886 2 2627 1599 FAX: +886 2 2627 1600 www.alltekmarine.com (Your Local Dealer/Agent Warranty Stamp) Version 1.42 II Please carefully read this manual before start using the AIS AtoN device. This product is an auxiliary monitoring device, and it should not be relied upon as the sole monitoring navigation system. Failure to operate this system in accordance with the operating instructions specified in this manual may result in unreliable or reduced system performance. Improper operation or installation may cause damage to the equipment or injury to personnel. AMEC shall in no event be liable for any loss of profit, personal injury, unpredictable damage arising out of incorrect operation or installation or any kind of product misuse or abuse. WARNING! SAFETY INSTRUCTIONS ELECTRICAL SHOCK HAZARD. Do not open the case of the equipment. Only qualified personnel should work inside the equipment. WARNING TURN OFF THE POWER IMMEDIATELY IF WATER LEAKS INTO THE EQUIPMENT OR OBJECT DROPS INTO THE EQUIPMENT. Continue operating the equipment could cause electrical shock or fire. Contact your nearest distributor for service. DO NOT DISASSEMBLE OR MODIFY THE EQUIPMENT. Improper disassemble or modification could cause electrical shocks, fire, or personal injury. WARNING DO NOT PLACE ANY LIQUID-FILLED CONTAINER ON TOP OF THE EQUIPMENT. Improper disassemble or modification could cause electrical shocks, fire, or personal injury. TURN OFF THE POWER IMMEDIATELY IF THE EQUIPMENT IS EMMITTING SMOKE OR FIRE. Continue operating the equipment could cause electrical shock or fire. Contact your nearest distributor for service. EVEN THOUGH THE EQUIPMENT IS WATERPROOF, PLEASE AVOID DIRECT CONTACT WITH RAIN FALLING OR WATER SPLASH. Electrical shock or fire could be resulted if water leaks into the equipment. AVOID OPERATING THE EQUIPMENT WITH WET HANDS. Electrical shocks could be resulted if operating with wet hands. PLEASE USE THE PROPER FUSE. Damage to the equipment or fire could be resulted if using the wrong fuse. III Table of Contents I. COPY RIGHT & DISCLAIMER II. WARNING & SAFETY INSTRUCTION III. FORWARD Pages 1 INTRODUCTION ................................................................................................ 1 1.1 MANDO-301/303 Overview .................................................................................................. 1 1.2 MANDO-301/303 Features ................................................................................................... 4 1.3 Type of AIS ........................................................................................................................... 5 1.4 AIS AtoN Message ............................................................................................................... 6 1.5 About This Manual .............................................................................................................. 7 2 INSTALLATION.................................................................................................. 8 2.1 General ................................................................................................................................. 8 2.1.1 Safety Instructions ........................................................................................................ 8 2.1.2 Items in the Package .................................................................................................... 9 2.2 Installation Procedure ......................................................................................................... 9 2.3. MANDO-301/303 External Connections .......................................................................... 12 2.4. Installing VHF Antenna .................................................................................................... 13 2.5. Installing GPS Antenna .................................................................................................... 15 3 WIRING DIAGRAM/PIN DEFINITION .............................................................. 17 4 MANDO-301/303 CONFIGURATION ............................................................... 20 4.1 Configuration Start-up ...................................................................................................... 20 4.2 Serial Port Searching ........................................................................................................ 21 4.2.1 Serial Port Setting ....................................................................................................... 21 4.2.2 VDL Setting .................................................................................................................. 25 4.3 AtoN MMSI Setup ............................................................................................................... 26 4.4 Delete Selected MMSI ..........................................................................…

Text truncated - open the document above for the full version.

External Photos

AIS AtoN Mando-301/303 External Photos: Mando-301 and Mando-303 have same external appearances, except the model label. 1) Mando-301/303 Top View 2) Mando-301/303 Rear View 3) Mando-301/303 Side View #1 4) Mando-301/303 Side View #2 5) Mando-301/303 Side View #3

ID Label/Location Info

AIS AtoN Mando-301/303 Product Label: (as of 07-Jun-2012) Mando-301 and Mando-303 use same product label. The model number will be marked during manufacturing. (1) Product Label: (2) Location of Label: 38mm 28mm Model: □ MANDO-301 □ MANDO-303 Power Supply: 12V DC only BSH Approval No.: 46162/4321542/10 FCC ID: WZ7ATON-301-303 Serial Number: Made in Taiwan www.alltekmarine.com AIS AtoN (Aids to Navigation) 0700

Internal Photos

AIS AtoN Mando-301/303 Internal Photos Mando-301 and Mando-303 use same PCBs. Some parts in Mando-301 model are not mounted during manufacturing, and all parts in Mando-303 model are mounited. (1) Mando-301 internal photo #1 (2) Mando-301 internal photo #2 (3) Mando-301 internal photo #3 (4) Mando-301 internal photo #4 (5) Mando-301 internal photo #5 (6) Mando-303 internal photo #1 (7) Mando-303 internal photo #2 (8) Mando-303 internal photo #3 (9) Mando-303 internal photo #4 (10) Mando-303 internal photo #5

Operational Description

1 1 INTRODUCTION 1.1 MANDO-301/303 Overview Aids to Navigation (AtoN) AIS is one of the latest applications of AIS technology. The AIS AtoN transponder can be installed in lighthouse, lantern, buoy, other fixed and floating aids, or offshore platforms to transmit warning, navigational, and meteorological data to approaching vessels and/or to shore stations. AMEC offers two types of AIS AtoN: MANDO-301 (Type 1) and MANDO-303 (Type 3).  Type 1 (MANDO- 301) – It transmits on FATDMA slots given in its configuration and has no receiver. The FATDMA slots must be pre-configured by base station. Figure 1-1-1 AIS AtoN Type 1 Block Diagram VHF Antenna GPS Antenna 2  Type 3 (MANDO-303) – It has AIS receive and transmit capabilities in accordance with Recommendation ITU-R M.1371. Using FATDMA/RATDMA. Figure 1-1-2 AIS AtoN Type 3 Block Diagram A pre-programmed transmitting schedule can be configured to broadcast AtoN messages through FATDMA or RATDMA. The MANDO-301/303 AtoN transponder is designed to broadcast the following messages:  Current position;  AtoN status;  Control information;  Support Synthetic, Virtual and Chaining functions;  Meteorological / hydrological information VHF Antenna GPS Antenna 3 In normal conditions, the unit transmits a report with AIS AtoN position in an ITU-R M.1371 message 21. In addition, the AIS AtoN broadcasts AIS Message 6, which enables the operator to monitor the AtoN device for solar/battery voltage, flash setting and light status. Subject to the fitting of appropriate measuring devices, meteorological/hydrological data and other parameters can be obtained via Message 8. A brief summary of all the messages processed by the AIS AtoN are defined in section 1.4. MANDO-301/303 AIS AtoN are fully IALA and IEC compliant devices, and provide users choices from basic PCB modules to rugged aluminum enclosed unit. The compact PCB module (102mm x 105mm x 49mm) is giving a great flexibility for users to integrate AIS AtoN transceiver into their floating lantern or buoy. The weatherproof anodized aluminum housing (140mm x 155mm x 60mm) offers user the variety of mounting methods. Moreover, AMEC’s MANDO series is one of the most power-saving AtoN transceivers with the low power consumption while offshore power resources are limited. MANDO-303 is also equipped with multiple digital/analog interfaces, which provides user the flexibility to connect other communication devices, hydraulic, and metrological sensors. 4 1.2 MANDO-301/303 Features  Low power consumption Operation condition: 12V DC, reporting interval 3 minutes. - MANDO-301: FATDMA: < 0.288 Ah/day - MANDO-303: FATDMA: < 0.432 Ah/day RATDMA: < 1.656 Ah/day  Multiple interfaces: - Analog input x 4 - Digital output x 1 - Digital input x 1 - RS-232 x 2 - 1 pps from internal GPS output  Support remote configuration (for MANDO-303 only)  Support meteorological & hydrological data  Customer design flexibility upon request 5 1.3 Type of AIS The marine Automatic Identification System (AIS) is a location and vessel information reporting system. Some elements of AIS networks are illustrated in the following table: Table 1-3 Type of AIS elements Class A AIS Transponder ‧ Transmits and receives AIS signal. ‧ Intended for vessels meeting the requirements of IMO AIS carriage requirement. ‧ It is mandatory for all commercial vessels that exceed 300 tons to be equipped with Class A AIS. Class B AIS Transponder ‧ Transmits and receives AIS signal. ‧ Not necessarily in full accord with IMO AIS carriage requirements. ‧ It is not mandatory for vessels to be equipped with Class B AIS. ‧ Suitable for recreational vessel, in enhancing its safety at sea. AIS Receiver ‧ Only receives AIS signal. ‧ Does not have transmitter to send out AIS signal. ‧ Suitable for recreational vessel that does not want to send out its vessel information. AIS AtoN ‧ AIS Aids to Navigation Station ‧ Transmits AIS AtoN signal. ‧ Receives .AIS AtoN signal. (Type 2 and Type 3 only) ‧ Capable of supporting synthetic and virtual AtoN. ‧ Can be installed in lighthouses, lanterns, buoys. ‧ Support lantern monitoring. ‧ Support meteorological and hydrological messages. 6 1.4 AIS AtoN Message Table 1-4 Summary of AIS AtoN Messages supported by Mando Series Message ID Message Type Slot Length Description 6 Addressed Binary Message 1 to 5 (varies) Binary payload that contains the MMSI, usually of a base station, which is designated to receive the message that is sent until it is acknowledged; May contain information about the AtoN equipment, such as meteorological and hydrological information that is obtained from a daughterboard or external sensors. 8 Broadcast Binary Message 1 to 5 (varies) Binary payload that broadcasts to any equipment that can receive it; May contain information about the AtoN equipment, such as meteorological and hydrological information that is obtained from a daughterboard or sensors. 12 Addressed Safety Related Message 1 to 5 (varies) Safety-related text that is addressed to a specific MMSI, usually a base station; Message is sent until it is acknowledged; Warns of an AtoN malfunction. 14 Broadcast Safety Related Message 1 to 5 (varies) Safety-related text for broadcast communication that is received by all units that can receive the message; Warns of an AtoN malfunction. 21 Aids to Navigation Report 2 slots AtoN position report that is usually transmitted every 3 minutes and is meant to be seen by all AIS transponders; Contains information about the AtoN, such as the origination MMSI, name of the AtoN (if applicable), and the type of AtoN (fixed or floating); Sends the Aids to Navigation Report and a warning to approaching vessels. 25 AtoN Position Report 1 to 5 (varies) Intended for short, infrequent data transmissions and is designed to save bandwidth; Used for chaining.

Parts List/Tune Up Info

Page 30 of Test Report NEI-LVD-2-S1105035:

Test Report

RV-1108001 Report No.: NEI-ETSE-1-R1105011 Page 1 of 39 Neutron Engineering Inc. EMC Test Report Issued Date : Aug. 04, 2011 Project No. : R1105011 Equipment : AIS Aids to Navigation (AtoN) Model Name : MANDO-301; MANDO-302; MANDO-303 Applicant : Alltek Marine Electronics Corp. Address : 7F, NO. 605, Ruei Guang Rd., Neihu, Taipei, Taiwan, R.O.C. 114 Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: May 24, 2011 Date of Test: May 24, 2011 ~ Jun. 13, 2011 Testing Engineer : ( Peter Li) Technical Manager : (Jeff Yang) Authorized Signatory : (Andy Chiu) Neutron Engineering Inc. B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan. TEL: +886-2-2657-3299 FAX: +886-2-2657-3331 RV-1108001 Report No.: NEI-ETSE-1-R1105011 Page 2 of 39 Neutron Engineering Inc. Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. RV-1108001 Report No.: NEI-ETSE-1-R1105011 Page 3 of 39 Neutron Engineering Inc. Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 2.3 APPLICABILITY OVERVIEW TABLES 8 3 . GENERAL INFORMATION 10 3.1 GENERAL DESCRIPTION OF EUT 10 3.2 DESCRIPTION OF TEST MODES 11 3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 3.4 DESCRIPTION OF SUPPORT UNITS 13 4 . EMC EMISSION TEST 14 4.1 RADIATED EMISSION MEASUREMENT 14 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT 14 4.1.2 MEASUREMENT INSTRUMENTS LIST 15 4.1.3 TEST PROCEDURE 15 4.1.4 DEVIATION FROM TEST STANDARD 15 4.1.5 TEST SETUP 16 4.1.6 EUT OPERATING CONDITIONS 16 4.1.7 TEST RESULTS-BETWEEN 30MHZ AND 1000MHZ 17 4.1.8 TEST RESULTS-ABOVE 1000MHZ 19 5 . EMC IMMUNITY TEST 21 5.1 STANDARD COMPLIANCE/SERVRITY LEVEL/CRITERIA 21 5.2 GENERAL PERFORMANCE CRITERIA 22 5.3 THE REQUIREMENT OF PERFORMANCE CRITERIA 22 5.4 GENERAL PERFORMANCE CRITERIA TEST SETUP 23 5.5 ESD TESTING 24 5.5.1 TEST SPECIFICATION 24 5.5.2 MEASUREMENT INSTRUMENTS 24 5.5.3 TEST PROCEDURE 24 5.5.4 DEVIATION FROM TEST STANDARD 25 5.5.5 TEST SETUP 25 5.5.6 TEST RESULTS 26 5.5.7 PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED 28 5.6 RS TESTING 29 5.6.1 TEST SPECIFICATION 29 5.6.2 MEASUREMENT INSTRUMENTS 29 5.6.3 TEST PROCEDURE 29 RV-1108001 Report No.: NEI-ETSE-1-R1105011 Page 4 of 39 Neutron Engineering Inc. Table of Contents Page 5.6.4 DEVIATION FROM TEST STANDARD 29 5.6.5 TEST SETUP 30 5.6.6 TEST RESULTS 31 5.7 EFT/BURST TESTING 32 5.7.1 TEST SPECIFICATION 32 5.7.2 MEASUREMENT INSTRUMENTS 32 5.7.3 TEST PROCEDURE 32 5.7.4 DEVIATION FROM TEST STANDARD 32 5.7.5 TEST SETUP 33 5.7.6 TEST RESULTS 34 5.8 INJECTION CURRENT TESTING 35 5.8.1 TEST SPECIFICATION 35 5.8.2 MEASUREMENT INSTRUMENTS 35 5.8.3 TEST PROCEDURE 35 5.8.4 DEVIATION FROM TEST STANDARD 35 5.8.5 TEST SETUP 36 5.8.6 TEST RESULTS 37 6 . EUT TEST PHOTO 38 RV-1108001 Report No.: NEI-ETSE-1-R1105011 Page 5 of 39 Neutron Engineering Inc. 1. CERTIFICATION E q u i p m e n t : AIS Aids to Navigation (AtoN) Brand Name : AMEC Model Name : MANDO-301; MANDO-302; MANDO-303 A p p l i c a n t : Alltek Marine Electronics Corp. Date of Test : May 24, 2011 ~ Jun. 13, 2011 Standards : EN 301 489-1 V1.8.1 (2008-04) EN 301 489-3 V1.4.1 (2002-08) EN 55022: 2006 +A1: 2007 Class B IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 +A1: 2007 +A2: 2010 IEC 61000-4-4: 2004 +A1: 2010 IEC 61000-4-6: 2008 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-ETSE-1-R1105011) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). RV-1108001 Report No.: NEI-ETSE-1-R1105011 Page 6 of 39 Neutron Engineering Inc. 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: Emission Standard Test Item Limit Judgment Remark EN 55022: 2006 +A1: 2007 Conducted Emission Class B N/A Conducted Emission At Telecommunication Ports Class B N/A Radiated Emission Class B PASS Immunity Section Test Item Performance Criteria Judgment Remark IEC 61000-4-2: 2008 Electrostatic Discharge B PASS IEC 61000-4-3: 2006 +A1: 2007 +A2: 2010 RF electromagnetic field A PASS IEC 61000-4-4: 2004 +A1: 2010 Fast transients B PASS IEC 61000-4-6: 2008 Injected Current A PASS NOTE: (1) ” N/A” denotes test is not applicable in this Test Report. RV-1108001 Report No.: NEI-ETSE-1-R1105011 Page 7 of 39 Neutron Engineering Inc. 2.…

Text truncated - open the document above for the full version.

Test Report

RV-1108001 Report No.: NEI-ETSE-2-R1105011 Page 1 of 44 Neutron Engineering Inc. EMC Test Report Issued Date : Aug. 04, 2011 Project No. : R1105011 Equipment : AIS Aids to Navigation (AtoN) Model Name : MANDO-301; MANDO-302; MANDO-303 Applicant : Alltek Marine Electronics Corp. Address : 7F, NO. 605, Ruei Guang Rd., Neihu, Taipei, Taiwan, R.O.C. 114 Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: May 24, 2011 Date of Test: May 24, 2011 ~ Jun. 13, 2011 Testing Engineer : ( Peter Li) Technical Manager : (Jeff Yang) Authorized Signatory : (Andy Chiu) Neutron Engineering Inc. B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan. TEL: +886-2-2657-3299 FAX: +886-2-2657-3331 RV-1108001 Report No.: NEI-ETSE-2-R1105011 Page 2 of 44 Neutron Engineering Inc. Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. RV-1108001 Report No.: NEI-ETSE-2-R1105011 Page 3 of 44 Neutron Engineering Inc. Table of Contents Page 1 . CERTIFICATION 5 2 . SUMMARY OF TEST RESULTS 6 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 DESCRIPTION OF TEST MODES 9 3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 3.4 DESCRIPTION OF SUPPORT UNITS 11 4 . EMC EMISSION TEST 12 4.1 CONDUCTED EMISSION MEASUREMENT 12 4.1.1 POWER LINE CONDUCTED EMISSION 12 4.1.2 MEASUREMENT INSTRUMENTS LIST 12 4.1.3 TEST PROCEDURE 13 4.1.4 DEVIATION FROM TEST STANDARD 13 4.1.5 TEST SETUP 13 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 TEST RESULTS-BETWEEN 0.01MHZ AND 0.15MHZ 15 4.1.8 TEST RESULTS-BETWEEN 0.15MHZ AND 30MHZ 17 4.2 RADIATED EMISSION MEASUREMENT 19 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 19 4.2.2 MEASUREMENT INSTRUMENTS LIST 20 4.2.3 TEST PROCEDURE 20 4.2.4 DEVIATION FROM TEST STANDARD 20 4.2.5 TEST SETUP 21 4.2.6 EUT OPERATING CONDITIONS 21 4.2.7 TEST RESULTS-BETWEEN 0.15MHZ AND 30MHZ 22 4.2.8 TEST RESULTS-BETWEEN 30MHZ AND 1000MHZ 23 4.2.9 TEST RESULTS- ABOVE 1000MHZ 25 5 . EMC IMMUNITY TEST 27 5.1 STANDARD COMPLIANCE/SERVRITY LEVEL/CRITERIA 27 5.2 GENERAL PERFORMANCE CRITERIA TEST SETUP 27 5.3 ESD TESTING 28 5.3.1 TEST SPECIFICATION 28 5.3.2 MEASUREMENT INSTRUMENTS 28 5.3.3 TEST PROCEDURE 28 5.3.4 DEVIATION FROM TEST STANDARD 29 5.3.5 TEST SETUP 29 RV-1108001 Report No.: NEI-ETSE-2-R1105011 Page 4 of 44 Neutron Engineering Inc. Table of Contents Page 5.3.6 TEST RESULTS 30 5.3.7 PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED 32 5.4 RS TESTING 33 5.4.1 TEST SPECIFICATION 33 5.4.2 MEASUREMENT INSTRUMENTS 33 5.4.3 TEST PROCEDURE 33 5.4.4 DEVIATION FROM TEST STANDARD 33 5.4.5 TEST SETUP 34 5.4.6 TEST RESULTS 35 5.5 EFT/BURST TESTING 36 5.5.1 TEST SPECIFICATION 36 5.5.2 MEASUREMENT INSTRUMENTS 36 5.5.3 TEST PROCEDURE 36 5.5.4 DEVIATION FROM TEST STANDARD 36 5.5.5 TEST SETUP 37 5.5.6 TEST RESULTS 38 5.6 INJECTION CURRENT TESTING 39 5.6.1 TEST SPECIFICATION 39 5.6.2 MEASUREMENT INSTRUMENTS 39 5.6.3 TEST PROCEDURE 39 5.6.4 DEVIATION FROM TEST STANDARD 39 5.6.5 TEST SETUP 40 5.6.6 TEST RESULTS 41 6 . EUT TEST PHOTO 42 RV-1108001 Report No.: NEI-ETSE-2-R1105011 Page 5 of 44 Neutron Engineering Inc. 1. CERTIFICATION E q u i p m e n t : AIS Aids to Navigation (AtoN) Brand Name : AMEC Model Name : MANDO-301; MANDO-302; MANDO-303 A p p l i c a n t : Alltek Marine Electronics Corp. Date of Test : May 24, 2011 ~ Jun. 13, 2011 Standards : EN 301 843-1 V1.2.1 (2004-06) EN 301 843-2 V1.2.1 (2004-06) IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 +A1: 2007 +A2: 2010 IEC 61000-4-4: 2004 +A1: 2010 IEC 61000-4-6: 2008 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-ETSE-2-R1105011) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). RV-1108001 Report No.: NEI-ETSE-2-R1105011 Page 6 of 44 Neutron Engineering Inc. 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: Emission EN 301 843-1 ; EN 301 843-2 Standard Test Item Limit Judgment Remark ------ Conducted Emission --- PASS Conducted Emission At Telecommunication Ports --- N/A Radiated Emission --- PASS Immunity EN 301 843-1 ; EN 301 843-2 Section Test Item Performance Criteria Judgment Remark IEC 61000-4-2: 2008 Electrostatic Discharge B PASS IEC 61000-4-3: 2006 +A1: 2007 +A2: 2010 RF electromagnetic field A PASS…

Text truncated - open the document above for the full version.

Test Report

RV-1108001 Report No.: NEI-ETSP-1-R1105011 Page 1 of 21 Neutron Engineering Inc. Radio Test Report Issued Date : Aug. 23, 2011 Project No. : R1105011 Equipment : AIS Aids to Navigation (AtoN) Model Name : MANDO-301; MANDO-302; MANDO-303 Applicant : Alltek Marine Electronics Corp. Address : 7F, NO. 605, Ruei Guang Rd., Neihu, Taipei, Taiwan, R.O.C. 114 Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Jun. 14, 2011 Date of Test: Jun. 14, 2011 ~ Jun. 20, 2011 Testing Engineer : (Gary Chou) Technical Manager : (Jeff Yang) Authorized Signatory : (Andy Chiu) Neutron Engineering Inc. B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan. TEL: +886-2-2657-3299 FAX: +886-2-2657-3331 RV-1108001 Report No.: NEI-ETSP-1-R1105011 Page 2 of 21 Neutron Engineering Inc. Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. RV-1108001 Report No.: NEI-ETSP-1-R1105011 Page 3 of 21 Neutron Engineering Inc. Table of Contents Page 1 . CERTIFICATION 4 2 . RFI EMISSIONS MEASUREMENT 5 2.1 TEST FACILITY 5 2.2 MEASUREMENT UNCERTAINTY 5 2.3 TEST CONDITIONS AND CHANNEL 5 2.4 TEST METHODOLOGY AND RESULTS 7 3 . GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 10 3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 3.4 DESCRIPTION OF SUPPORT UNITS 12 3.5 EUT OPERATING CONDITIONS 12 4 . SPURIOUS EMISSIONS – RECEIVER (30 - 1000MHz) 13 4.1 APPLIED PROCEDURES / LIMIT 13 4.1.1 MEASUREMENT INSTRUMENTS LIST 13 4.1.2 MEASURING INSTRUMENTS AND SETTING 13 4.1.3 TEST PROCEDURE 14 4.1.4 DEVIATION FROM TEST STANDARD 14 4.1.5 TEST SETUP LAYOUT 14 4.1.6 EUT OPERATING CONDITIONS 14 4.1.7 RESULTS OF STANDBY MODE SPURIOUS EMISSIONS 14 4.1.8 TEST RESULTS 15 5 . SPURIOUS EMISSIONS – RECEIVER (ABOVE 1000MHz) 17 5.1 APPLIED PROCEDURES / LIMIT 17 5.1.1 MEASUREMENT INSTRUMENTS LIST 17 5.1.2 MEASURING INSTRUMENTS AND SETTING 17 5.1.3 TEST PROCEDURE 18 5.1.4 DEVIATION FROM TEST STANDARD 18 5.1.5 TEST SETUP LAYOUT 18 5.1.6 EUT OPERATING CONDITIONS 18 5.1.7 RESULTS OF STANDBY MODE SPURIOUS EMISSIONS 18 5.1.8 TEST RESULTS 19 6 . EUT TEST PHOTO 21 RV-1108001 Report No.: NEI-ETSP-1-R1105011 Page 4 of 21 Neutron Engineering Inc. 1. CERTIFICATION E q u i p m e n t : AIS Aids to Navigation (AtoN) Brand Name : AMEC Model Name : MANDO-301; MANDO-302; MANDO-303 A p p l i c a n t : Alltek Marine Electronics Corp. Date of Test : Jun. 14, 2011 ~ Jun. 20, 2011 Standards : EN 300 440-1 V1.6.1 (2010-08) EN 300 440-2 V1.4.1 (2010-08) The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-ETSP-1-R1105011) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). RV-1108001 Report No.: NEI-ETSP-1-R1105011 Page 5 of 21 Neutron Engineering Inc. 2. RFI EMISSIONS MEASUREMENT 2.1 TEST FACILITY The test facilities used to collect the test data in this report: CB07: 1F., No. 61, Ln. 77, Sing-ai Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.) 2.2 MEASUREMENT UNCERTAINTY Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y). The measurement instrumentation uncertainty considerations contained in CISPR 16-4-2. Parameters Uncertainty Radio frequency ±1 x 10-7 RF power (conducted) ±2,5 dB Radia…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Leo Hsieh(QC Specialist)
[email protected]+886-2-8691-8568Fax: +886-2-2627-1600

Technical Contact

Alltek Marine Electronics CorpAlbert Lee
[email protected]+886 2 2627 1599

7F, No.605, Ruei-Guang Rd., Neihu · Taipei · Taiwan

Non-Technical Contact

Alltek Marine Electronics CorpYi-Yuan Chiou
[email protected]+886 2 2627 1599

Test Firm

PHOENIX TESTLAB GmbHHolger Bentje
[email protected]49-5235-9500-24Fax: 49-5235-9500-28

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
180156.025 MHz - 162.025 MHz12.5 W16K0GXW500.0000000000 Hz
Confidentiality
Long Term

Other Applications from Alltek Marine Electronics Corporation

AIS AtoN (Aids to Navigation) - FCC ID WZ7ATON-N321-N323 - Alltek Marine Electronics Corporation
WZ7ATON-N321-N323

AIS AtoN (Aids to Navigation)

Jun 30, 2023

Equipment Class

AIS - Automatic Identification Systems
AIS Class B CSTDMA Transponder with Chartplotter - FCC ID WZ7AIS-P200CS - Alltek Marine Electronics Corporation
WZ7AIS-P200CS

AIS Class B CSTDMA Transponder with Chartplotter

Dec 20, 2020

Equipment Class

AIS - Automatic Identification Systems
AIS Class B SOTDMA Transponder with Chartplotter - FCC ID WZ7AIS-P200SO - Alltek Marine Electronics Corporation
WZ7AIS-P200SO

AIS Class B SOTDMA Transponder with Chartplotter

Dec 20, 2020

Equipment Class

AIS - Automatic Identification Systems
AIS Class B Transponder - FCC ID WZ7AIS-W - Alltek Marine Electronics Corporation
WZ7AIS-W

AIS Class B Transponder

Feb 13, 2014

Equipment Class

AIS - Automatic Identification Systems
AIS Class B Transponder - FCC ID WZ7AIS-B108 - Alltek Marine Electronics Corporation
WZ7AIS-B108

AIS Class B Transponder

Feb 12, 2014

Equipment Class

AIS - Automatic Identification Systems