Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 04, 2013
Application Purpose
Original Equipment
Date of Application
Dec 04, 2013
Equipment Note
Care Pal dongle
Frequency Range
2402.00000000 - 2480.00000000
Company
digiO2 International Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

I/O portUSB 2.0 Storage capacity32 MB for 30-day data storage Bluetooth4.0 class 2 LED indicators2 Rating5Vdc, 100mA Supported OS Operation Environment Storage Environment Windows® 8, Windows® 7, Windows® XP 10~40C (50~104F), 10% to 95% RH -20~50C (-4~122F), 5% to 95% RH (Non-condensing) Care Pal Dongle Thank you for purchasing an digiO2 product! The Care Pal dongle is a Bluetooth dongle that integrates data from compatible Bluetooth-enabled sphygmometers, electr ocardiograms, pulse oximeters, blood glucose meters, weighing scales, and thermometers. Using the Care Pal dongle, data from these compatible medical devices may be sent to a paired PC via wireless and secured transfers. dongle cover USB connector Network LED Bluetooth LED Installing the Care Pal dongle software IMPORTANT! Ensure that your syst em runs .Net Framework 3.5 before installing the Care Pal dongle software. You may download this version via www.microsoft.c om/en-us/download/details.aspx?id=21#overview 1. Turn on your computer or laptop then connect the Care Pal dongle to a USB 2.0 port. 2. Under My Computer, open the Care Pal dongle’s storage driv e then select eHealthSetup. 3. Choose Yes in the succeeding window to begin the installation process. LED status indicators Network LED ColorStatus BlueNetwork is online. Orange Bluetooth LED Color Status Blue Bluetooth is enabled. Orange Bluetooth is disabled. Using your Care Pal dongle 1. Turn on your laptop or computer . Problems LED display does not light upNo powerMake sure that your PC is powered on. Network LED display turns OrangeNetwork is oineCheck your PC network is workable. Bluetooth LED display turns OrangeBluetooth is disableUnplug your dongle and insert it again. CauseSuggested Actions 2. Insert the Care Pal dongle in an available USB 2.0 port on your laptop or computer . 3. Turn on the bluetooth device you would like to pair with your Care Pal dongle. IMPORTANT! Ensure that all the devices are within a 3-meter range from the dongle. 4. The fol lo wing screen appears to prompt you t o i nput y our current data using the compatible bluetooth device. Safety tips when using your Care Pal dongle Marks and Abbreviation Troubleshooting • device. • • is also removed to avoid overwriting it with new data. ISO 7010-M001 ISO 7010-M002 IEC 60417-5031 General mandatory action sign Refer to instruction manual/booklet NOTE: On ME EQUIPMENT “Follow instructions for use” Direct current WARNING – if the enclosure of this device is damaged, please do not use it, electrical shock hazard may occur. WARNING - Do not modify this equipment without authorization of the manufacturer. Accessory equipment connected to the analog and digital interfaces must be in compliance with the respective nationally harmonized IEC standards (i.e. IEC 60950 for data processing equipment, IEC 60065 for video equipment, IEC 61010-1 for laboratory equipment, and IEC 60601-1 for medical equipment.) Furthermore all configurations shall comply with the system standard IEC 60601-1-1. Anyone who connects additional equipment to the signal input part or signal output part is configuring a medical system, and is therefore, responsi¬ble that the system complies with the requirements of the system standard IEC 60601-1-1. The unit is for exclusive interconnection with IEC 60601-1 certified equipment in the patient environment and IEC 60XXX certified equipment out¬side of the patient environment. If in doubt, consult the technical services department or your local representative. Cleaning Instructions • Wipe with a dry cloth Disposing of your old product Within the European Union EU-wide legislation, as implemented in each Member State, requires that waste electrical and electronic products carrying the mark (left) must be disposed of separately from normal household waste. This includes monitors and electrical accessories, such as signal cables or power cords. When you need to dispose of your display products, please follow the guidance of your local authority, or ask the shop where you purchased the product, or if applicable, follow any agreements made between yourself. The mark on electrical and electronic products only applies to the current European Union Member States. Gui dance and manufacturer’s declaration – electromagnetic immunity The model CPW-103 is intended for us e in the electromagnetic environment specified below. The customer or the user of the model CPW-103 should assure that it is used in such an env ironment. Immunity test IEC 60601 test level Compliance level Electromagnetic enviro nment – guid ance Electr ostatic discharge (ESD) IE C 61000-4-2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with s ynthetic material, the relative humidity s hould be at least 30 %. Electr ic al fast tr ansient/burst IE C 61000-4-4 2 kV for power supply l ines 1 kV for i nput/output lines 2 kV for power supply lines 1 kV for input/output lines Mains power quality should be that of a typical commercial or hospital environment. Sur ge IE C 61000-4-5 1 kV line(s) to line(s) 2 kV line(s) to earth 1 kV line(s) to line(s) 2 kV line(s) to earth Mains power quality should be that of a typical commercial or hospital environment. interruptions and voltage variations on power supply input lines IE C 61000-4-11 <5 % UT (>95 % dip in UT) for 0,5 cycle 40 % UT (60 % di p in UT) for 5 cycles 70 % UT (30 % di p in UT) for 25 cycles <5 % UT (>95 % dip in UT) for 5 sec <5 % UT (>95 % dip in UT) for 0,5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles <5 % UT (>95 % dip in UT) for 5 sec Mains power quality should be that of a typical commercial or hospital environment. If the user of the model CPW-103 requires continued operation during power mains interruptions, it is recommended that the model CPW-103 be powered fro m an uninterrupti ble power supply or a battery. Power frequency (50/60 Hz) magneti c field IE C 61000-4-8 3 A/ …

Text truncated - open the document above for the full version.

Cover Letter(s)

For the following information Ref. File No.: C1M1310155 Product : Care Pal dongle Model Number : CPW-103 Applicant : digiO2 International Co., Ltd. Manufacturer : digiO2 International Co., Ltd. Factory : digiO2 International Co., Ltd. Standards : FCC 47 CFR Part 15 Subpart B/Oct. 2012 and CISPR 22/1997 and ICES-003 (Class B Limit) We hereby certify that the above product has been tested by us and complied with the FCC and IC official limits. These products might be marketed at the US accordance to FCC Rule based on the standard 47 CFR Part 2 and Part 15 Class B Equipment Regulations. The test was performed accordance to the procedures from ANSI C63.4-2009. The test data & results are issued on the test report no. EM-F1020773. Signature _____________________________ Ben Cheng/Manager Date: Nov. 08, 2013 Test Laboratory: AUDIX Technology Corporation, EMC Department NVLAP Lab. Code: 200077-0 FCC OET Designation: TW1004 Web Site: www.audixtech.com The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo. NVLAP Lab Code 200077-0

Cover Letter(s)

SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Revised wording (obsolete) 1.0 2.0 Sept–25-2007 Updated company template (current) 2.0 3.0 Jan-31-2012 Authority to Act as Agent Date: Oct. 23, 2013 SIEMIC, INC. 775 Montague Expressway, Milpitas, CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, digiO2 International Co., Ltd. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Name: Care Pal dongle Model Name: CPW-103 We affirm that between SIEMIC and digiO2 International Co., Ltd. , any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Thank you, Agency Agreement Expiration Date: _____ Oct. 09, 2014 _____ By: _ ________ __ Wayne Hsu ______ (Signature) (Print name) Title: _______ Assistant Manager__________ On behalf of: ___ digiO2 International Co., Ltd (Company Name) Telephone: ____+886226985791 _______

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 Request for Confidentiality Date: Oct. 23, 2013 Federal Communications Commission Authorization and Evaluation Division Subject: Confidentiality Request regarding Application for certification of FCC ID: X58-CPW-103 Gentlemen: Pursuant to Section 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: ‹ Functional Block Diagram ‹ Operational Description (theory of operation) ‹ Schematic Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, _______________________________________ Wayne Hsu digiO2 International Co., Ltd.. 4F-13, No. 79, Sec. 1, Hsin Tai Wu Rd., Hsi Chih Dist., New Taipei City 22101, Taiwan

External Photos

digiO2 International Co., Ltd. Care Pal dongle FCC ID : X58-CPW-103 EUT External Photos Photo 1 General Appearance (Front & Side View) Photo 2 General Appearance (Back & Side View) digiO2 International Co., Ltd. Care Pal dongle FCC ID : X58-CPW-103 Photo 3 General Appearance (USB Connector)

ID Label/Location Info

digiO2 International Co., Ltd. Care Pal dongle FCC ID : X58-CPW-103 ID Label Location z Label Placement Location (Back View of EUT) z ID Label Format ID Label Placement Location

Internal Photos

digiO2 International Co., Ltd. Care Pal dongle FCC ID : X58-CPW-103 EUT Internal Photos Photo 4 Internal View (Removed Cover) Photo 5 Internal View (Removed Internal Boards) digiO2 International Co., Ltd. Care Pal dongle FCC ID : X58-CPW-103 Photo 6 Internal View (Main Board, Front View) Photo 7 Internal View (Main Board, Back View) digiO2 International Co., Ltd. Care Pal dongle FCC ID : X58-CPW-103 Photo 8 Internal View (RF Board, Back View) Photo 9 Internal View (RF Board, Front View) digiO2 International Co., Ltd. Care Pal dongle FCC ID : X58-CPW-103 Photo 10 Internal View (RF Board, Front View With Removed Shielded Cover)

RF Exposure Info

Maximum Permissive Exposure FCC ID: X58-CPW-103 Product Name: Care Pal Dongle Model No: CPW-103 [Maximum measured transmitter power] The max output power E.I.R.P=-1.916dBm=0.00064mW Per KDB 447498 clarifies "When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.", this device has output power 0.00064mW < threshold 10 mW thus this device is exempt from SAR test. Sincerely Yours, ____________________________________ Wayne Hsu Assistant Manager digiO2 International Co., Ltd.

Test Report

FCC ID. X58-CPW-103 Page 1 of 59 AUDIX Technology Corporation Report No. EM-F1020772 APPLICATION FOR CERTIFICATION On Behalf of digiO2 International Co., Ltd. Care Pal dongle Models No.CPW-103 FCC IDX58-CPW-103 BranddigiO2 Prepared for : digiO2 International Co., Ltd. 4F-13, No. 79, Sec. 1, Hsin Tai Wu Rd., Hsi-Chih Dist., New Taipei City 221, Taiwan Prepared By : AUDIX Technology Corporation EMC Department No. 53-11, Dingfu, Linkou Dist., New Taipei City 244, Taiwan Tel : (02) 2609-9301, 2609-2133 Fax: (02) 2609-9303 File Number C1M1310155 Report Number EM-F1020772 Date of Test Oct. 28 ~ Nov. 07, 2013 Date of Report Nov. 08, 2013 FCC ID. X58-CPW-103 Page 2 of 59 AUDIX Technology Corporation Report No. EM-F1020772 TABLE OF CONTENTS Description Page TEST REPORT CERTIFICATION .......................................................................................................4 1. GENERAL INFORMATION .......................................................................................................5 1.1. Description of Device (EUT) .................................................................................................................. 5 1.2. Tested Supporting System Details .......................................................................................................... 5 1.3. Description of Test Facility .................................................................................................................... 6 1.4. Measurement Uncertainty ....................................................................................................................... 6 2. POWERLINE CONDUCTED EMISSION MEASUREMENT ................................................7 2.1. Test Equipment ....................................................................................................................................... 7 2.2. Block Diagram of Test Setup.................................................................................................................. 7 2.3. Powerline Conducted Emission Limit (§15.207) .................................................................................... 7 2.4. Operating Condition of EUT .................................................................................................................. 8 2.5. Test Procedure ........................................................................................................................................ 8 2.6. Powerline Conducted Emission Measurement Results ........................................................................... 8 3. RADIATED EMISSION MEASUREMENT ............................................................................11 3.1. Test Equipment ..................................................................................................................................... 11 3.2. Block Diagram of Test Setup................................................................................................................ 11 3.3. Radiated Emission Limits (§15.209) .................................................................................................... 13 3.4. Operating Condition of EUT ................................................................................................................ 13 3.5. Test Procedure ...................................................................................................................................... 14 3.6. Radiated Emission Measurement Results ............................................................................................. 15 4. 20dB BANDWIDTH MEASUREMENT ...................................................................................23 4.1. Test Equipment ..................................................................................................................................... 23 4.2. Block Diagram of Test Setup................................................................................................................ 23 4.3. Specification Limits [§15.247(a)(1)] .................................................................................................... 23 4.4. Operating Condition of EUT ................................................................................................................ 23 4.5. Test Procedure ...................................................................................................................................... 23 4.6. Test Results ........................................................................................................................................... 24 5. CARRIER FREQUENCY SEPARATION MEASUREMENT ..............................................28 5.1. Test Equipment ..................................................................................................................................... 28 5.2. Block Diagram of Test Setup................................................................................................................ 28 5.3. Specification Limits [§15.247(a)(1)] .................................................................................................... 28 5.4. Operating Condition of EUT ................................................................................................................ 28 5.5. Test Procedure ...................................................................................................................................... 28 5.6. Test Results ........................................................................................................................................... 29 6. TIME OF OCCUPANCY MEASUREMENT ..........................................................................34 6.1. Test Equipment ..................................................................................................................................... 34 6.2. Block Diagram of Test Setup....................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID. X58-CPW-103 Page 57 of 59 AUDIX Technology Corporation Report No. EM-F1020772 12. PHOTOGRAPHS 12.1. Photos of Conducted Disturbance Measurement FRONT VIEW OF CONDUCTED MEASUREMENT BACK VIEW OF CONDUCTED MEASUREMENT FCC ID. X58-CPW-103 Page 58 of 59 AUDIX Technology Corporation Report No. EM-F1020772 12.2. Photos of Radiated Emission Measurement at Semi-Anechoic Chamber 12.2.1. Frequency Range 30MHz-1GHz 12.2.2. Frequency Range Above 1GHz FCC ID. X58-CPW-103 Page 59 of 59 AUDIX Technology Corporation Report No. EM-F1020772 12.3. Photo of Section RF Conducted Measurement

Contact Information

Applicant

Amber Dong
[email protected]+886-2-26989999Fax: +886-2-26989216

Test Firm

Audix Technology CorporationLeon Liu
[email protected]822-609-2133Fax: 886 2 26099303

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz640.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.

Other Applications from digiO2 International Co., Ltd.

Non-Contact Thermometer - FCC ID X58-ETH-301 - digiO2 International Co., Ltd.
X58-ETH-301

Non-Contact Thermometer

Dec 04, 2014

Equipment Class

DTS - Digital Transmission System
BT Infrared Ear Thermometer - FCC ID X58-ETH-102 - digiO2 International Co., Ltd.
X58-ETH-102

BT Infrared Ear Thermometer

Nov 05, 2013

Equipment Class

DTS - Digital Transmission System
Cardio Care - FCC ID X58-ECG10X - digiO2 International Co., Ltd.
X58-ECG10X

Cardio Care

Aug 25, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
CARE PAL - FCC ID X58-CPW-101 - digiO2 International Co., Ltd.
X58-CPW-101

CARE PAL

May 18, 2010

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TiltMon - FCC ID X58-TLM101 - digiO2 International Co., Ltd.
X58-TLM101

TiltMon

Mar 21, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter