Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
GlobalTrak™ Field Setup and Diagnostic Guide System Planning Corporation 1000 Wilson Boulevard Arlington, VA 22209 (703) 351- 8200 GlobalTrak ™ Field Setup and Diagnostic Guide GlobalTrak™ Field Setup and Diagnostic Guide This purpose of the GlobalTrak ™ Field Setup and Diagnostic Guide is to: • Test each module as installed for fielding To complete the Field Setup and Diagnostic procedure, the following are necessary: 1. Completed, Configured GlobalTrak installation 2. Laptop computer with RS232 port 3. CMU Field Test Cable 4. CMU Key switch 5. Quad-band GSM phone with Kore SIM card (Optional) 6. Orbcomm Antenna Analyzer (Optional) * 7. Orbcomm Spectrum Analyzer (Optional) * 8. Orbcomm View Software (Optional) * * Note: Items 6, 7, 8 only needed for installations requiring satellite communication Prepared: R. Straz Date: May 31, 2006 Page 2 of 17 GlobalTrak ™ Field Setup and Diagnostic Guide Table of Contents 1.0 Initial Setup..........................................................................................................................................4 Connect the CMU to HyperTerminal...................................................................................................................4 Capture Diagnostic Information..........................................................................................................................5 Configure Device for Deployment.....................................................................Error! Bookmark not defined. 2.0 Testing Sensor Module Operation.......................................................................................................6 Test Analog Sensor Functionality......................................................................Error! Bookmark not defined. Test Door Switch Functionality.........................................................................Error! Bookmark not defined. Test GPS functionality.........................................................................................................................................8 3.0 Testing Cellular Communication........................................................................................................9 4.0 Testing Satellite Communication......................................................................................................10 5.0 Final Configuration...........................................................................................................................11 Appendix A: Field Test Checklist...........................................................................................................13 Appendix B: Troubleshooting................................................................................................................16 Problems with Sensor Modules.........................................................................................................................16 Problems with GSM Communication................................................................................................................17 Problems with Satellite Communication............................................................................................................17 Prepared: R. Straz Date: May 31, 2006 Page 3 of 17 GlobalTrak ™ Field Setup and Diagnostic Guide 1.0 Initial Setup Connect the CMU to HyperTerminal 1.1. Disconnect the fielded CMU Cable circular connector (if any) and connect the field test cable as shown in figure 1.1. INSERT FIGURE HERE Figure 1.1 1.2. Open a HyperTerminal on the computer. 1.3. Name the connection by the following convention and press ‘OK’. XXXX_MM-DD-YY XXXX = Last four digits of the CMU serial number MM = two digit month DD = two digit day YY = two digit year 1.4. Select the COM port number that the CMU is connected to and press ‘OK’. 1.5. Set the COM port properties using the settings shown in Figure 1.2 and press ‘OK’. Figure 1.2 Prepared: R. Straz Date: May 31, 2006 Page 4 of 17 GlobalTrak ™ Field Setup and Diagnostic Guide Capture Diagnostic Information 1.6. Start log capture by clicking on ‘Capture Text...’ from the ‘Transfer’ menu. 1.7. In the Capture Text dialog box, name the file as shown in Figure 1.3. Use the same convention as in step 1.3. Figure 1.3 1.8. Note the location and filename on the field test checklist in appendix A: 1.9. Click ‘Start’ to begin capturing text. Prepared: R. Straz Date: May 31, 2006 Page 5 of 17 GlobalTrak ™ Field Setup and Diagnostic Guide 2.0 Testing Sensor Module Operation Note: Be sure to complete 1.0 initial setup. Test Sensor Suite functionality 2.1 Configure the installation as follows. Door (If Applicable): Open Mount (If Applicable): Unmounted External Power (If Applicable): Disconnected 2.2 Switch the CMU to the On (Horizontal) position. 2.3 Allow the CMU to run through one complete boot cycle and switch the AMU to the Off position. Completion is indicated by the screenshot shown in Figure 2.1. Figure 2.1 Prepared: R. Straz Date: May 31, 2006 Page 6 of 17 GlobalTrak ™ Field Setup and Diagnostic Guide 2.4 Open the file created in step 1.9 with Notepad. 2.5 Use the ‘Find’ function to search for sensor readings by opening the ‘Find’ dialog box in the ‘Edit’ menu. Search for “LR Creation” as shown below in Figure 2.2. Figure 2.2 2.6 As shown in Figure 2.3, the sensor values are listed below the “LR Creation” line. Figure 2.3 2.7 Record results in Appendix B: Field Test Checklist. The values should be with the ranges listed in Appendix A. If a sensor is out of range, consult Appendix C for troubleshooting. 2.8 Close Notepad Prepared: R. Straz Date: May 31, 2006 Page 7 of 17 GlobalTrak ™ Field Setup and Diagnostic Guide 2.9 Configure the installation as follows. Door (If Applicable): Closed Mount (If Applicable): Mounted External Power (If Applicable): Connected 2.10 Repeat Steps 2.2 through 2.8 Test GPS functionality 2.11 Using the same Notepad window opened in step 2.9, use the ‘Find’ function to find …
Text truncated - open the document above for the full version.
SPC GlobalTrak Product Specification Written by: MobiApps Inc. System Planning Corporation 7315 Wisconsin Ave, 1000 Wilson Blvd. Suite 1050 E Arlington, VA 22201 Bethesda, MD 20814 This document contains confidential and proprietary information of SPC and MobiApps. Disclosure to unauthorized third parties without the expressed, written permission of MobiApps Inc. is prohibited. Version: 2.10 Date: November 14, 2007 SPC & MobiApps Proprietary & Confidential Document © 2006 V3d Product Specification, Version 2.06 Document Approvals Person Signature Date Approved by: Open Issues Date Person Issue SPC & M0biApps Proprietary & Confidential Document © 2006 Page ii V3d Product Specification, Version 2.06 Confidentiality Notice This document contains technical information propriety to MobiApps, Inc. Any and all information contained herein is of a confidential nature, and may only be reviewed by MobiApps employees or authorized personnel. SPC & M0biApps Proprietary & Confidential Document © 2006 Page iii V3d Product Specification, Version 2.06 Revision History Version # Date Description of Changes Author 2.02 20-Aug-06 Shift from V3c/p to V3d. Numerous Changes, all tracked in MS Word. S.Mazur 2.03 28-Aug-06 Added revisions following internal review 2.05 30-Aug-06 Added revisions following SPC review 2.06 14-Sep-06 Added revisions following CDR 2.07 15-Sep-06 More revision following CDR R. Straz 2.10 14-Nov-07 Added Always on Mode Added LED Blink Codes R. Straz SPC & M0biApps Proprietary & Confidential Document © 2006 Page iv V3d Product Specification, Version 2.06 Table of Contents 1.0 SCOPE....................................................................................................................................................1 1.1 PURPOSE AND OVERVIEW....................................................................................................................................1 1.2 AUDIENCE............................................................................................................................................................1 1.3 REVISION CONTROL.............................................................................................................................................1 1.4 CONVENTIONS......................................................................................................................................................1 1.5 PRIORITIES...........................................................................................................................................................1 1.6 DESIGN VERIFICATION.........................................................................................................................................2 1.7 DOCUMENT OVERVIEW........................................................................................................................................2 1.8 REFERENCES........................................................................................................................................................3 2.0 PRODUCT OVERVIEW..........................................................................................................................4 2.1 FEATURE LIST......................................................................................................................................................4 2.2 ASSET TRACKING AND MONITORING...................................................................................................................4 3.0 FUNCTIONAL AND ELECTRICAL REQUIREMENTS..........................................................................5 3.1 SENSORS..............................................................................................................................................................5 3.1.1 Optic Sensor...................................................................................................................................5 3.1.1.1 Performance...........................................................................................................................................................5 3.1.1.2 Function..................................................................................................................................................................5 3.1.1.3 Configuration.........................................................................................................................................................5 3.1.1.4 Mounting................................................................................................................................................................5 3.1.2 Acoustic Sensor..............................................................................................................................5 3.1.2.1 Performance...........................................................................................................................................................5 3.1.2.2 Function..................................................................................................................................................................5 3.1.2.3 Configuration.........................................................................................................................................................6 3.1.2.4 Mounting................................................................................................................................................................6 3.1.3 Door Sensor....................................................................................................................................6 3.1.3.1 Performance...........................................................................................................................................................6 3.1.3.2 Function............................................................................................................…
Text truncated - open the document above for the full version.
Long Term Confidentiality Request Letter June 23, 2010 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR FCC ID: XDY-WEDGEV3 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the following required to be submitted with this application be permanently withheld from public review. V3D Schematic 3V1.pdf 202996-_Unit Assy.pdf Wedge OTA Protocol.pdf The above documents are company proprietary information that should never get into the possession of your competition. Please contact me if there is any information you may need. Sincerely, Drew Boudreau
9G490ASSY202966-07 FCC ID: XDY-WEDGEV3 REV: A SN: 12345
WEDGE OPERATIONAL DESCRIPTION Overview : The Wedge provides local control for remote installations. The device communicates over public GSM networks to internet software. It provides position information via GPS and local wireless control of local networks via ZigBee. Operational : When the device is turned on, it will initialize all external periphery of the main CPU that is located within the GSM module. The device will then monitor these periphery, temperature, motion, and location via GPS receiver. It can also create ad hoc networks utilizing the ZigBee protocol and on-board ZigBee module. At a user defined reporting interval a message will be sent over the GSM network that interfaces with internet software for user view. If the GSM network is not available the unit will try and transmit via satellite using a provided module. All modules are used within the manufacturer’s guidelines and the only added antenna is for the GSM module, we use a PTCRB certified antenna.
Holley Group Co., Ltd. FCC ID: VQMHZME3A Page 1 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F09090 Prepared For : Holley Group Co., Ltd. No.181 Wuchang Avenue, Yuhang District, Hangzhou 310023, P.R.China Prepared By :Audix Technology (Shanghai) Co., Ltd. 3F 34Bldg 680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 Fax: +86-21-64955491 Report No. : ACI-F09090 Date of Test : Oct 09, 2009 Date of Report : Oct 10, 2009 Application for FCC Certification On behalf of Holley Group Co., Ltd. Product Name: 1mW ZigBee Module Model No.: HT-MDL-Z-EM-2400-001-A-V3.0.0 Serial No.: E2009093001 FCC ID: VQMHZME3A (MPE Calculation) Holley Group Co., Ltd. FCC ID: VQMHZME3A Page 2 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F09090 TABLE OF CONTENTS Page 1 GENERAL INFORMATION.............................................................................................. 4 1.1 Description of Equipment Under Test............................................................................ 4 1.2 Description of Test Facility ............................................................................................ 5 1.3 Measurement Uncertainty .............................................................................................. 5 2 SUMMARY OF STANDARDS AND RESULTS .............................................................. 6 2.1 Applicable Standard ....................................................................................................... 6 2.2 Specification Limits .......................................................................................................6 2.3 MPE Calculation Method ............................................................................................... 6 2.4 Calculated Result............................................................................................................ 7 Holley Group Co., Ltd. FCC ID: VQMHZME3A Page 3 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F09090 TEST REPORT FOR FCC CERTIFICATE Applicant : Holley Group Co., Ltd. Manufacturer 1# : Holley Group Co., Ltd. Trademark 1# : Holley Manufacturer 2# : Zhejiang Hornetone Information Technology Co., Ltd. Trademark 2# : Hornetone EUT Description : 1mW ZigBee Module (A) Model No. : HT-MDL-Z-EM-2400-001-A-V3.0.0 (B) Serial No. : E2009093001 (C) Power Supply : DC 3.3V Test Procedure Used: FCC OET Bulletin 65 August 1997 The device described above is tested by Audix Technology (Shanghai) Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC OET Bulletin 65. The test results are contained in this test report and Audix Technology (Shanghai) Co., Ltd. is assumed full responsibility for the accuracy and completeness of these measurements. This report also shows that the EUT (M/N: HT-MDL-Z-EM-2400-001-A -V3.0.0, S/N: E2009093001), which was tested on Oct 09, 2009 is technically compliance with the FCC limits. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of Audix Technology (Shanghai) Co., Ltd. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Date of Test : Oct 09, 2009 Date of Report : Oct 10, 2009 Producer : ZENO GU / Assistant Review : SAMMY CHEN/ Assistant Manager Signatory : BYRON KWO / Manager Holley Group Co., Ltd. FCC ID: VQMHZME3A Page 4 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F09090 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test Description : 1mW ZigBee Module Type of EUT ; Production Pre-product Pro-type Model Number : HT-MDL-Z-EM-2400-001-A-V3.0.0 Serial Number : E2009093001 Applicant : Holley Group Co., Ltd. No.181 Wuchang Avenue, Yuhang District, Hangzhou 310023, P.R.China Manufacturer 1# : Holley Group Co., Ltd. No.181 Wuchang Avenue, Yuhang District, Hangzhou 310023, P.R.China Trademark 1# : Holley Manufacturer 2# : Zhejiang Hornetone Information Technology Co., Ltd. No.181 Wuchang Avenue, Yuhang District, Hangzhou 310023, P.R.China Trademark 2# : Hornetone Power Supply : DC 3.3V (from Carry board) Radio Tech : IEEE 802.15.4 (ZigBee®) Freq. Band : 2405 MHz ~ 2480 MHz In 5 MHz Separation Tested Freq. : 2405 MHz (Channel 11) 2440 MHz (Channel 18) 2480 MHz (Channel 26) Freq. Channel : 16 channels Antenna1 Gain : 1.8dBi Antenna2 Gain : 2.1dBi Holley Group Co., Ltd. FCC ID: VQMHZME3A Page 5 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F09090 1.2 Description of Test Facility Site Description : Sept. 17, 1998 file on (Semi-Anechoic Chamber) Apr 29, 2009 Renewed Federal Communications Commission FCC Engineering Laboratory 7435 Oakland Mills Road Columbia, MD 21046, USA Name of Firm : Audix Technology (Shanghai) Co., Ltd. Site Location : 3 F 34 Bldg 680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai 200233, China FCC registration Number : 91789 Accredited by NVLAP, Lab Code : 200371-0 1.3 Measurement Uncertainty Output Power Expanded Uncertainty : U = 0.30 dB Holley Group Co., Ltd. FCC ID: VQMHZME3A Page 6 of 7 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F09090 2 SUMMARY OF STANDARDS AND RESULTS 2.1 Applicable Standard FCC OET Bulletin 65:1997 2.2 Specification Limits Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 , |H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f2)* 30 30-300 27.5 0.073 0.2 30 300-1500 -- -- f/150 30 1500-100,000 -- -- 1.0 30 f = frequency in MHz *Plane-wave equivalent power density NOTE: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for…
Text truncated - open the document above for the full version.
MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE ! BALTIMORE, MARYLAND 21230-3432 ! PHONE (410) 354-3300 ! FAX (410) 354-3313 33439 WESTERN AVENUE ● UNION CITY, CALIFORNIA 94587 ● PHONE (510) 489-6300 ● FAX (510) 489-6372 3162 BELICK STREET ● SANTA CLARA, CALIFORNIA 95054 ● PHONE (408 748-3585 ● FAX (510) 489-6372 The Nation’s First Licensed Nationally Recognized Testing Laboratory June 28, 2010 System Planning Corporation 3601 Wilson Blvd. Arlington, VA 22201 Dear Drew Boudreau, Enclosed is the EMC Wireless test report for compliance testing of the System Planning Corporation, Wedge as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Part 15, Subpart B for a Class B Digital Device and FCC Part 15 Subpart C for Intentional Radiators. Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or if MET can be of further service to you, please feel free to contact me. Sincerely yours, MET LABORATORIES, INC. Jennifer Warnell Documentation Department Reference: (\System Planning Corporation\EMC29362B-FCC247 Rev 1) Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc. Electromagnetic Compatibility Syste m Planning Corporation Cover Page Wedge CFR Title 47, Part 15B, 15.247 MET Report: EMC29362B-FCC247 Rev 1 © 2010, MET Laboratories, Inc. Page ii of vii DOC-EMC702 2/18/2010 Electromagnetic Compatibility Criteria Test Report for the System Planning Corporation Wedge Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B for Class B Digital Devices & 15.247 Subpart C for Intentional Radiators MET Report: EMC29362B-FCC247 Rev 1 June 28, 2010 Prepared For: System Planning Corporation 3601 Wilson Blvd. Arlington, VA 22201 Prepared By: MET Laboratories, Inc. 914 W. Patapsco Ave. Baltimore, MD 21230 Electromagnetic Compatibility Syste m Planning Corporation Cover Page Wedge CFR Title 47, Part 15B, 15.247 MET Report: EMC29362B-FCC247 Rev 1 © 2010, MET Laboratories, Inc. Page iii of vii DOC-EMC702 2/18/2010 Electromagnetic Compatibility Criteria Test Report for the System Planning Corporation Wedge Tested under the FCC Certification Rules contained in Title 47 of the CFR, Parts 15 Subpart B for Class B Digital Devices & 15.247 Subpart C for Intentional Radiators Ankur Vaseashta, Project Engineer Jennifer Warnell Electromagnetic Compatibility Lab Documentation Department Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules Parts 15B, 15.247 under normal use and maintenance. Shawn McMillen, Wireless Manager, Electromagnetic Compatibility Lab Electromagnetic Compatibility Syste m Planning Corporation Report Status Wedge CFR Title 47, Part 15B, 15.247 MET Report: EMC29362B-FCC247 Rev 1 © 2010, MET Laboratories, Inc. Page iv of vii DOC-EMC702 2/18/2010 Report Status Sheet Revision Report Date Reason for Revision June 21, 2010 Initial Issue. 1 June 28, 2010 Editorial Corrections Electromagnetic Compatibility Syste m Planning Corporation Table of Contents Wedge CFR Title 47, Part 15B, 15.247 MET Report: EMC29362B-FCC247 Rev 1 © 2010, MET Laboratories, Inc. Page v of vii DOC-EMC702 2/18/2010 Table of Contents I. Executive Summary .................................................................................................................................................1 A. Purpose of Test ...................................................................................................................................................2 B. Executive Summary ............................................................................................................................................2 II. Equipment Configuration .......................................................................................................................................3 A. Overview.............................................................................................................................................................4 B. References...........................................................................................................................................................5 C. Test Site ..............................................................................................................................................................5 D. Description of Test Sample.................................................................................................................................6 E. Equipment Configuration....................................................................................................................................8 F. Support Equipment .............................................................................................................................................8 G. Ports and Cabling Information ............................................................................................................................8 H. Mode of Operation..............................................................................................................................................8 I. Method of Monitoring EUT Operation ...............................................................................................................9 J. Modifications .............................................................................................................…
Text truncated - open the document above for the full version.
Holley Group Co., Ltd. FCC ID: VQMHZME3A Page 1 of 51 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F09089 Prepared For : Holley Group Co., Ltd. No.181 Wuchang Avenue, Yuhang District, Hangzhou 310023, P.R.China Prepared By :Audix Technology (Shanghai) Co., Ltd. 3F 34Bldg 680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai 200233, China Tel: +86-21-64955500 Fax: +86-21-64955491 Report No. : ACI-F09089 Date of Test : Sep 30 - Oct 09, 2009 Date of Report : Oct 10, 2009 Application for FCC Certification On behalf of Holley Group Co., Ltd. Product Name: 1mW ZigBee Module Model No.: HT-MDL-Z-EM-2400-001-A-V3.0.0 Serial No.: E2009093001 FCC ID: VQMHZME3A Holley Group Co., Ltd. FCC ID: VQMHZME3A Page 2 of 51 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-F09089 TABLE OF CONTENTS Page 1 SUMMARY OF STANDARDS AND RESULTS ............................................................... 5 1.1 Description of Standards and Results.............................................................................. 5 2 GENERAL INFORMATION............................................................................................... 6 2.1 Description of Equipment Under Test............................................................................. 6 2.2 Peripherals ....................................................................................................................... 7 2.3 Description of Test Facility ............................................................................................. 7 2.4 Measurement Uncertainty ............................................................................................... 7 3 RADIATED EMISSION TEST............................................................................................ 8 3.1 Test Equipment................................................................................................................ 8 3.2 Block Diagram of Test Setup .......................................................................................... 8 3.3 Radiated Emission Limit [FCC Part 15 Subpart C 15.209(a)&15.205(a)(c)]................. 9 3.4 Test Configuration........................................................................................................... 9 3.5 Operating Condition of EUT ......................................................................................... 10 3.6 Test Procedures ............................................................................................................. 10 3.7 Test Results ................................................................................................................... 11 4 6 dB BANDWIDTH MEASUREMENT............................................................................ 36 4.1 Test Equipment.............................................................................................................. 36 4.2 Block Diagram of Test Setup ........................................................................................ 36 4.3 Specification Limits (§15.247(a)(2))............................................................................. 36 4.4 Operating Condition of EUT ......................................................................................... 36 4.5 Test Procedure ............................................................................................................... 36 4.6 Test Results ................................................................................................................... 37 5 MAXIMUM PEAK OUTPUT POWER MEASUREMENT........................................... 40 5.1 Test Equipment.............................................................................................................. 40 5.2 Block Diagram of Test Setup ........................................................................................ 40 5.3 Specification Limits ((§15.247(b)(3)) ........................................................................... 40 5.4 Operating Condition of EUT ......................................................................................... 40 5.5 Test Procedure ............................................................................................................... 40 5.6 Test Re…
Text truncated - open the document above for the full version.
3601 Wilson Blvd · Arlington, Virginia · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.40 mW |

GPS based tracking device with GSM and Globalstar modules
Equipment Class
DTS - Digital Transmission System
Bolt for Wireless Container Security
Equipment Class
DTS - Digital Transmission System
local control for remote installations
Equipment Class
DTS - Digital Transmission System