FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Thinkify LLC/
  3. XE2C

XE2CUHF RFID Reader Module

Thinkify LLC
UHF RFID Reader Module - FCC ID XE2C - Thinkify LLC
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Feb 02, 2021
Application Purpose
Original Equipment
Date of Application
Feb 02, 2021
Equipment Note
UHF RFID Reader Module
Frequency Range
902.75000000 - 927.25000000
Company
Thinkify LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Thinkify, LLC TR100 RFID Reader Module Setup Guide and Protocol Reference January 2021 1 Notices Notices Copyright ©2020 Thinkify, LLC. All rights reserved. Thinkify, LLC has intellectual property rights relating to technology embodied in the products described in this document, including without limitation certain patents or patent pending applications in the U.S. or other countries. This document and the products to which it pertains are distributed under licenses restricting their use, copying, distribution and decompilation. No part of this product documentation may be reproduced in any form or by any means without the prior written consent of Thinkify, LLC and its licensors, if any. Third party software is copyrighted and licensed from Licensors. Thinkify, the Thinkify logo, Insight and other graphics, logos, and service names used in this document are trademarks of Thinkify, LLC in the U.S. and other countries. All other trademarks are the property of their respective owners. U.S. Government approval required when exporting the product described in this documentation. Federal Acquisitions: Commercial Software -- Government Users Subject to Standard License Terms and Conditions. U.S. Government: If this Software is being acquired by or on behalf of the U.S. Government or by a U.S. Government prime contractor or subcontractor (at any tier), then the Government's rights in the Software and accompanying documentation shall be only as set forth in this license; this is in accordance with 48 C.F.R. 227.7201 through 227.7202-4 (for Department of Defense (DoD) acquisitions) and with 48 C.F.R. 2.101 and 12.212 (for non-DoD acquisitions). DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARANTEES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR APARTICULAR PURPOSE OR NON-INFRINGMENT ARE HEREBY DISCLAIMED, EXCEPT TO THE EXTENT THATSUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Note Regarding RF Exposure This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm in the US or 33cm, (Canada), between the radiator (antenna) and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2 FCC and IC Notice and Cautions: FCC and IC Notice and Cautions: FCC Any changes or modifications to this device not expressly approved by Thinkify, LLC could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio/TV technician for help. IC This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1.This device may not cause interference. 2.This device must accept any interference, including interference that may cause undesired operation of the device. 3 Modular Use, Procedures, and Integration Instructions The Thinkify module must only be used under the following conditions outlined throughout this document. Voltage: The unit should have a stable and lower noise 5 volt supply from either the USB or the serial interface. Noise should be less than 50 mV peak to peak and the 5 Volts supply should var y less than plus or minus 5% under operation. Heat: The unit should be placed in such a manner that heat is allowed to exit the module. It is recommended that the device be placed with at least 200 square cm of heat sink when operating near the upper power, (above 200 mW), of the unit. Antennas: Only patch antennas of 6 dBil or less gain are authorized with this module. In all cases radiated power should be kept to a minimum. All end users shall adhere to all aspects of the integration procedures and instructions outlined in this section. This radio transmitter 9962A-100 has been approved by Innovation, Science and Economic Development Canada to operate with the antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device. Acceptable antennas, US and Canada: Patch antennas only. All patch antennas must have less than 6dBil gain. All must be nominally of 50 Ohm impedance. No other antenna types are approved at this time. Please contact Thinkify in reference to any antennas used. Separation: This equipment should be installed and operated with minimum distance of 20 cm in the US or 33cm, (Canada), between the radiator (antenna) and any part of any human body. The end …

Text truncated - open the document above for the full version.

Attestation Statements

Page #1 Supplier's Declaration of Conformity 47 CFR § 2.1077Compliance Information Unique Identifier: Thinkify TR100 Responsible Party –U.S. Contact Information Thinkify LLC 18450 Technology Drive, Morgan Hill, California 95037 408-782-7111 www.thinkifyit.com FCC Compliance Statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Copyright 2020 Thinkify LLC. All Rights Reserved. Thinkify, LLC, 18450 Technology Drive, Suite E1, Morgan Hill, Ca. 95037, www.thinkifyit.com 408-782-7111

External Photos

PHOTOS - EXTERNAL Company: Thinkify LLC Product Name: TR100 Report No.: THNK16 – External Photos Title: THNK16 External Photos To: Serial #: Issue Date: 01 October 2020 Page: 2 of 4 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com 1. External Photographs 1.1.1. Product - External Top View Title: THNK16 External Photos To: Serial #: Issue Date: 01 October 2020 Page: 3 of 4 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com Bottom View 575 Boulder Court Pleasanton, California 94566, USA Tel: +1 (925) 462 0304 Fax: +1 (925) 462 0306 www.micomlabs.com

ID Label/Location Info

Thinkify, LLC 18450 Technology Drive, Morgan Hill, CA 95037 PH: 408.782.7111, Web: www.thinkifyit.com Company Confidential TR100 This device coplies with part 15 or the FCC rules. Operation is subject to the following two conditions. 1 – This device may NOT cause harmful interference. 2 – This device must accept any interference received, including interference that may cause undesired operation. FCC ID: XE2C IC ID: 9962A-100 Thinkify LLC 18450 Technology Drive, Suite E1 Morgan Hill, Ca. 95037 www.thinkifyit.com 25 mm 33 mm Thinkify, LLC 18450 Technology Drive, Morgan Hill, CA 95037 PH: 408.782.7111, Web: www.thinkifyit.com Company Confidential TR100 This device coplies with part 15 or the FCC rules. Operation is subject to the following two conditions. 1 – This device may NOT cause harmful interference. 2 – This device must accept any interference received, including interference that may cause undesired operation. FCC ID: XE2C IC ID: 9962A-100 Thinkify LLC 18450 Technology Drive, Suite E1 Morgan Hill, Ca. 95037 www.thinkifyit.com

Internal Photos

PHOTOS - INTERNAL Company: Thinkify LLC Product Name: TR100 Report No.: THNK16 – Internal Photos Title: THNK16 Internal Photos To: Serial #: Issue Date: 01 October 2020 Page: 2 of 4 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com 1. Internal Photographs 1.1.1. Product - Internal Bottom View Heatsink Removed Title: THNK16 Internal Photos To: Serial #: Issue Date: 01 October 2020 Page: 3 of 4 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com Top View Shield Removed 575 Boulder Court Pleasanton, California 94566, USA Tel: +1 (925) 462 0304 Fax: +1 (925) 462 0306 www.micomlabs.com

RF Exposure Info

MPE/RF EXPOSURE REPORT FCC CFR 47 Part 1.1310 THNK16-U3 FCC Rev A Company: Thinkify LLC Model: TR100 MPE/RF EXPOSURE REPORT Company: Thinkify LLC Model: TR100 To: FCC CFR 47 Part 1.1310 Report Serial No.: THNK16-U3 FCC Rev A This report supersedes: NONE Applicant: Thinkify LLC 18450 Technology Drive, Suite E1 Morgan Hill, California 95037 USA Issue Date: 1 st October 2020 This Report is Issued Under the Authority of: MiCOM Labs, Inc. 575 Boulder Court Pleasanton California 94566 USA Phone: +1 (925) 462-0304 Fax: +1 (925) 462-0306 www.micomlabs.com MiCOM Labs is an ISO 17025 Accredited Testing Laboratory Title: Thinkify LLC TR100 To: FCC CFR 47 Part 1.1310 Serial #: THNK16-U3 FCC Rev A Issue Date: 1 st October 2020 Page: 3 of 4 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com 1. MAXIMUM PERMISSABLE EXPOSURE Calculations for Maximum Permissible Exposure Levels Power Density = Pd (mW/cm 2 ) = EIRP/(4*π*d 2 ) EIRP = P * G P = Peak output power (mW) G = Antenna numeric gain (numeric) d = Separation distance (cm) Numeric Gain = 10 ^ (G (dBi)/10) Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power density is 1.0 mW/cm 2 These calculations represent worst case in terms of the exposure levels. Freq. Band (MHz) Ant Gain (dBi) Numeric Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Calculated Power Density (mW/cm 2 ) @ 20cm Power Density Limit (mW/cm 2 ) Min Calculated safe distance for Limit (cm) 902 – 928.0 6 3.98 29.70 933.25 0.739 1.00 17.19 Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if calculations indicate the MPE distance to be less. Specification Maximum Permissible Exposure Limits FCC §1.1310 Limit = 1mW / cm 2 from 1.310 Table 1 575 Boulder Court Pleasanton, California 94566, USA Tel: +1 (925) 462 0304 Fax: +1 (925) 462 0306 www.micomlabs.com

Test Report

REGULATORY COMPLIANCE TEST REPORT FCC CFR 47 15.247, RSS-247 Issue 2 Report No.: THNK16-U2 Rev A Company: Thinkify LLC Model Name: TR100 REGULATORY COMPLIANCE TEST REPORT Company: Thinkify LLC Model Name: TR100 To: FCC CFR 47 15.247, RSS-247 Issue 2 Test Report Serial No.: THNK16-U2 Rev A This report supersedes: NONE Applicant: Thinkify LLC 18450 Technology Drive, Suite E1 Morgan Hill, California 95037 USA Issue Date: 1 st October 2020 This Test Report is Issued Under the Authority of: MiCOM Labs, Inc. 575 Boulder Court Pleasanton California 94566 USA Phone: +1 (925) 462-0304 Fax: +1 (925) 462-0306 www.micomlabs.com MiCOM Labs is an ISO 17025 Accredited Testing Laboratory Title: Thinify LLC TR100 To: FCC 15.247 & RSS-247 Serial #: THNK16-U2 Rev A Issue Date: 1 st October 2020 Page: 3 of 63 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com Table of Contents 1. ACCREDITATION, LISTINGS & RECOGNITION ................................................................................ 4 1.1. TESTING ACCREDITATION ........................................................................................................ 4 1.2. RECOGNITION ............................................................................................................................. 5 1.3. PRODUCT CERTIFICATION ........................................................................................................ 6 2. DOCUMENT HISTORY ......................................................................................................................... 7 3. TEST RESULT CERTIFICATE ............................................................................................................. 8 4. REFERENCES AND MEASUREMENT UNCERTAINTY ..................................................................... 9 4.1. Normative References .................................................................................................................. 9 4.2. Test and Uncertainty Procedure ................................................................................................. 10 5. PRODUCT DETAILS AND TEST CONFIGURATIONS ..................................................................... 11 5.1. Technical Details ......................................................................................................................... 11 5.2. Scope Of Test Program .............................................................................................................. 12 5.3. Equipment Model(s) and Serial Number(s) ................................................................................. 13 5.4. Antenna Details ........................................................................................................................... 13 5.5. Cabling and I/O Ports .................................................................................................................. 13 5.6. Test Configurations ..................................................................................................................... 13 5.7. Equipment Modifications ............................................................................................................. 13 5.8. Deviations from the Test Standard ............................................................................................. 13 6. TEST SUMMARY ................................................................................................................................ 14 7. TEST EQUIPMENT CONFIGURATION(S) ......................................................................................... 15 7.1. Conducted ................................................................................................................................... 15 7.2. Radiated Emissions .................................................................................................................... 17 8. MEASUREMENT AND PRESENTATION OF TEST DATA ............................................................... 20 8.1. Peak Transmit Power .................................................................................................................. 21 8.2. 20 dB & 99% Bandwidth ............................................................................................................. 24 8.3. Frequency Hopping Tests ........................................................................................................... 26 8.3.1. Number of Hopping Channels .............................................................................................. 27 8.3.2. Channel Separation .............................................................................................................. 28 8.3.3. Chanel Dwell Time & Occupancy ......................................................................................... 29 8.4. Emissions .................................................................................................................................... 30 8.4.1. Conducted Emissions ........................................................................................................... 30 8.4.1.1. Conducted Unwanted Spurious Emissions ................................................................... 31 8.4.1.2. Conducted Band-Edge Emissions ................................................................................. 32 8.4.2. Radiated Emissions .............................................................................................................. 36 8.4.2.1. TX Spurious & Restricted Band Emissions ................................................................... 39 8.4.2.2. Radiated Emissions (0.03 - 1 GHz) .............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

PHOTOS - TEST SETUP Company: Thinkify LLC Product Name: TR100 Report No.: THNK16 – Test Setup Photos Title: THNK16 Test Setup Photos To: Serial #: Issue Date: 01 October 2020 Page: 2 of 7 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com 1. Test Setup Photographs 1.1.1. Test Setup - RE#1 - Radiated Emissions - 3m Chamber Digital Emissions 1GHz to 18GHz Title: THNK16 Test Setup Photos To: Serial #: Issue Date: 01 October 2020 Page: 3 of 7 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com Digital Emissions 30MHz to 1GHz Title: THNK16 Test Setup Photos To: Serial #: Issue Date: 01 October 2020 Page: 4 of 7 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com Transmitter Spurious Emissions 1GHz to 18GHz Title: THNK16 Test Setup Photos To: Serial #: Issue Date: 01 October 2020 Page: 5 of 7 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com Transmitter Spurious Emissions 30MHz to 1GHz Title: THNK16 Test Setup Photos To: Serial #: Issue Date: 01 October 2020 Page: 6 of 7 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs personnel. All changes will be noted in the Document History section of the report. MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com 1.1.2. Test Setup - RF#1 - Conducted Conducted RF 575 Boulder Court Pleasanton, California 94566, USA Tel: +1 (925) 462 0304 Fax: +1 (925) 462 0306 www.micomlabs.com

Contact Information

Applicant

Curt L Carrender
[email protected]408-782-7111Fax: 408-782-2111

Test Firm

MiCOM LabsGordon Hurst
[email protected]925-462-0304Fax: 925-462-0306

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.75 MHz - 927.25 MHz934.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Single Modular Approval: OEM integrators must be provided with antenna installation instructions. The OEM integrators must be instructed to ensure that the end user has no manual instructions to remove or install the device. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Only the antenna those antennas tested with the device or similar patch type antennas with equal or lesser gain may be used with this transmitter.

Other Applications from Thinkify LLC

XE2TF8

T2000 AEI Reader

Sep 17, 2015

Equipment Class

LMS - Part 90 Location & Monitoring Transmitter
UHF RFID 915 MHz Module - FCC ID XE2TF7 - Thinkify LLC
XE2TF7

UHF RFID 915 MHz Module

Sep 30, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
UHF RFID Reader - FCC ID XE2TF6 - Thinkify LLC
XE2TF6

UHF RFID Reader

Nov 27, 2010

Equipment Class

LMS - Part 90 Location & Monitoring Transmitter
UHF RFID Reader - FCC ID XE2TF4 - Thinkify LLC
XE2TF4

UHF RFID Reader

Nov 18, 2010

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter