0 Tablet PA0850 Quick Start Guide 1 Description of the device Starting up Before using your for the first time, please charge the battery completely. Charging the battery Connect the supplied power cable to the Tablet PA08 50 power connector and the wall outlet. a) Please allow a minimum of 4 hours for a full charge of the battery. Power Earphone USB DC 5V input Backspace Micro SD MIC 2 tablet PA0850 interface The device uses a full capacitive touchscreen. All areas of the touchscreen will react when you tap o n it with your finger. 3 Menu bar icons explained Return Returns to the previously viewed screen Home Touch on Home to return to the desktop. This a ction will not close the applications that are open. Recent applications Displays list of recently opene d applications Menu Provides access to Wallpaper, Applications and Settings options Volume Control Increase / Decrease volume Other Messages Shows information such as memory card connected and Wi-Fi connection Time Indicator Shows current time Battery Indicator Shows the charge status of the bat tery. Applications Opens Application / Widgets screen The menu bar will change depending on which screen is being displayed. 4 Finding your way around After the start-up procedure is complete, the table t will show the Home screen, as below. Please note; the wallpaper on your device may differ from that shown within the images in this guide. Slide your finger horizontally on the display to mo ve to the extended screens on the left or right. 5 Customising the Home screen To add a Home screen icon (application, shortcut, w idget, etc), touch the Application icon, , which is located at the top-right corner of the screen. Hold your finger on the desi red app/widget and drag it to the desired location o n the Home screen. You can also customise the wallpaper by touching th e Menu icon, . Here you can choose from pre-loaded ‘Live’ and s tandard wallpaper options. The Menu icon also allows you to manage applications and system settings. To delete an app or widget from the desktop; press, hold and drag the icon to “x Remove” which appears at the top of the page as shown below. 6 The App Drawer The Application drawer can be accessed by pressing t he application icon, on the Home screen. The Application drawer gives access to all pre-loade d and downloaded apps and widgets on the device, inc luding Mail, Music, Video player (Super HD-Player), Clock, Bookmarks, etc. Tap on any application icon to open the correspondi ng application. You can get more Android applications via the Slide Me market, which can be found on the Home screen. 7 Connecting to the internet The Tablet PA0850CA1 connects to the internet over a Wi-Fi network. If you have connected the device to a network previou sly, it will attempt to reconnect to the network. a) To configure a new Wi-Fi connection, go to the Home screen, tap the Menu icon and then select System Settings. b) In the Settings screen, under the Wireless & Network s option, touch the Wi-Fi On/Off button to turn the Wi-Fi on or off. c) With the Wi-Fi turned on, the screen will then show all available wireless networks. d) Tap to select the wireless network name you want to co nnect to. Enter the required pass code, if applica ble and tap Connect. You are now fully connected to your network and to the internet! 8 Transferring media to your Tablet PA0850 The Tablet PA0850 allows for file transfer in three different ways: 1. Via the USB OTG port, When connected to a PC using a USB-A to mini USB-B cable (not supplied), the PC will recognise the int ernal storage of the tablet. It is then possible to transfer files to an d from the Tablet. 2. Via an external drive, When connected, the tablet will recognise a USB driv e (not supplied) which can be attached to the Table t via the supplied USB adapter cable. It is then possible to transfer files to and from the Tablet. 3. Via the MicroSD card slot, Files can be transferred directly to and from a Mic roSD card. a) Remove the MicroSD card with the Tablet PA0850 power ed off or use dismount procedure, see user manual a t www.google.com b) Connect the MicroSD card to your computer and copy the relevant files. c) Replace the card back in the Tablets MicroSD card s lot. The copied files (images, music, video, etc) will ap pear in the relevant app, i.e. music files will app ear in the music app, video files will appear in the Super-HD player, etc. 9 Hereby, SHUOYING INDUSTRIAL(SHENZHEN)CO.,LTD., decl ares that this PA0850is in compliance with the essen tial requirements and other relevant provisions of Directive 1999/5/EC. T he declaration of conformity may be consulted at ww w.shuoying.com/DOC.pdf lithium battery : CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCT IONS TO THE INSTRUCTIONS Headset: To prevent possible hearing damage,do not listen at high volume levels for long periods Correct Disposal of this product. This marking indi cates that this product should not be disposed with other household wastes throughout the EU. To prevent possi ble harm to the environment or human health from un controlled waste disposal, recycle it responsibly to promote the sus tainable reuse of material resources. To return you r used device, please use the return and collection systems or contact the retail er where the product was purchased. They can take thi s product for environmental safe recycling. 10 Warning: Changes or modifications to this unit not expressly approved by the party responsible for co mpliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device , pursuant to Part 15 of the FCC Rules. These limits are designed to provide re asonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio fre quency energy and, if not installed and use…
Text truncated - open the document above for the full version.
SHUOYING INDUSTRIAL(SHENZHEN)CO.,LTD 2013-7-10 FCC ID: XJN-PA0850X We hereby declare that our device with the FCC ID above does not initiate and it can not be configured to initiate any transmission on any non-US frequencies or unauthorized frequencies. This includes probes, beacons, and ad-hoc mode transmissions. Our operation is limited to the following frequencies and modes: 802.11b Channel 1 (2412MHz) – Channel 11(2462MHz) 802.11g Channel 1 (2412MHz) – Channel 11(2462MHz) 802.11n (20MHz) Channel 1 (2412MHz) – Channel 11(2462MHz)
SHUOYING INDUSTRIAL(SHENZHEN)CO.,LTD DATE: 2013-7-1 FCC DECLARATION OF CONFORMITY (DoC) Trade Name(s): Model Number(s): PA0850 Our device above has been tested and found to be compliant with the FCC Part 15 Class B limits as a computer peripheral. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Details of test lab and documentation Test Lab Name: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch FCC Test Site Accreditation Number (as seen on FCC website): TW1050 Test report number and issue date: FD130415C13 R1 July. 01, 2013 SHUOYING INDUSTRIAL(SHENZHEN)CO.,LTD
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Test Report No.: RF130610N001 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Test Report No.: RF130610N001 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Test Report No.: RF130610N001 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Test Report No.: RF130610N001
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Test Report No.: RF130610N001 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Test Report No.: RF130610N001 Antenna Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Test Report No.: RF130610N001
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] No SAR justification for FCC ID : XJN-PA0850X Following FCC KDB 447498 D01 “General SAR test exclusion guidance” The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100MHz to 1500 MHz b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz 3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion. a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm. b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test separation distances ≤ 50 mm. c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be acceptable. Smallest distance from the antenna and radiating structures or outer surface of the device The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] SAR Test Exclusion Thresholds Mode Frequency (GHz) Maximum source-based time averaged conducted output power including tune-up tolerance (mW) Minimum separation distance (mm) Result of Eq. 1 Limit for 1-g SAR Limit for 10-g extremity SAR Verdict 802.11b 2.412 7.551 5 2.35 3.0 7.5 Exempt from SAR 802.11g 2.437 8.337 5 2.60 3.0 7.5 Exempt from SAR 802.11n (HT20) 2.462 7.656 5 2.40 3.0 7.5 Exempt from SAR Conclusion Therefore our device complies with FCC’s RF radiation exposure limits for general population without SAR evaluation.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 47 Report Version 1 Test Report No.: RF130610N001 TEST REPORT Applicant SHUOYING INDUSTRIAL(SHENZHEN)CO.,LTD Address: Shuoying Road,Hebei Industry Area,Dalang,Longhua Town,Baoan,Shenzhen,China. Manufacturer or Supplier SHUOYING INDUSTRIAL(SHENZHEN)CO.,LTD Address: Shuoying Road, Hebei Industry Area, Dalang, Longhua Town, Baoan, Shenzhen, China. Product MID Brand Name N/A Model PA0850 Additional Model & Model Difference N/A Date of tests Jun. 11, 2013 ~ Jun. 20, 2013 The tests have been carried out according to the requirements of the following standard: FCC Part 15, Subpart C (Section 15.247) CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Kent Liu Specialist / EMC Department Approved by Sam Tung Manager / EMC Department This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 47 Report Version 1 Test Report No.: RF130610N001 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................. 4 1 SUMMARY OF TEST RESULTS .................................................................................................... 5 2 MEASUREMENT UNCERTAINTY.................................................................................................. 5 3 GENERAL INFORMATION ............................................................................................................. 6 3.1 GENERAL DESCRIPTION OF EUT........................................................................................... 6 3.2 DESCRIPTION OF TEST MODES............................................................................................. 7 3.2.1 CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 8 3.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL.................................... 8 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS...........................................................11 3.4 DESCRIPTION OF SUPPORT UNITS......................................................................................11 4 TEST TYPES AND RESULTS ...................................................................................................... 12 4.1 CONDUCTED EMISSION MEASUREMENT........................................................................... 12 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................... 12 4.1.2 TEST INSTRUMENTS..................................................................................................... 12 4.1.3 TEST PROCEDURES ..................................................................................................... 13 4.1.4 DEVIATION FROM TEST STANDARD ........................................................................... 13 4.1.5 TEST SETUP................................................................................................................... 14 4.1.6 EUT OPERATING CONDITIONS .................................................................................... 14 4.1.7 TEST RESULTS .............................................................................................................. 15 4.2 RADIATED EMISSION MEASUREMENT ................................................................................ 17 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 17 4.2.2 TEST INSTRUMENTS..................................................................................................... 18 4.2.3 TEST PROCEDURES ..................................................................................................... 19 4.2.4 DEVIATION FROM TEST STANDARD ........................................................................... 19 4.2.5 TEST SETUP................................................................................................................... 20 4.2.6 EUT OPERATING CONDITIONS .................................................................................... 20 4.2.7 TEST RESULTS .............................................................................................................. 21 4.3 6dB BANDWIDTH MEASUREMENT ....................................................................................... 32 4.3.1 LIMITS…
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Test Report No.: RF130610N001 SET-UP FOR CONDUTED EMISSION TEST Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version 1 Test Report No.: RF130610N001 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz~1GHz > Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version 1 Test Report No.: RF130610N001 Frequency Range< ABOVE 1GHz >
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 8.00 mW |

IP Camera
Equipment Class
DTS - Digital Transmission System
Mobile Internet Devices
Equipment Class
JBP - Part 15 Class B Computing Device PeripheralMobile internet device
Equipment Class
DTS - Digital Transmission System
Mobile Internet Devices
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Mobile Internet Device
Equipment Class
DTS - Digital Transmission System