Microchip Pet Door Instruction Manual 2-27 Gebrauchsanweisung 28-54 Handleiding 55-80 Notice D’utilisation 81-106 Brugervejledning 107-132 Manual De Uso 133-158 Manuale D’Uso 159-184 Bruksanvisning 185-210 GB E DK I F D NL NO 2 Important Notice Please read all these instructions BEFORE fitting the SureFlap Microchip Pet Door. Importantly, please check whether there is metal in the substrate the door is to be fitted into. Please follow the metal mount instructions in section 7.4 if this is the case. Under no circumstances should you cut or drill through the tunnel of the main assembly of the unit as this contains the microchip reader and will prevent the unit from working properly. The SureFlap Microchip Pet Door operates with all 9, 10, and 15-digit microchips that are commonly used for pet identification. Alternatively, you can use the pet door with the SureFlap RFID Collar Tag (one included – packs of two sold separately), please see section 5 for more information. Every effort has been made to ensure that the SureFlap Microchip Pet Door operates with all relevant microchips. However, there are a small number of circumstances relating to the position of your pet’s microchip and the signal strength of the individual chip, which may mean that the pet door does not operate reliably. We therefore strongly advise that the following checks are carried out before permanent changes are made to a door to install the pet door: 1. Insert batteries (for instructions see section 8) and leave for 10 seconds with nothing in the tunnel so the sensors can settle. 2. Follow the learn process as in section 6, encouraging your pet to put its head up to the door in order to learn the microchip’s number. Once a pet’s microchip number has been successfully learnt, the flap reverts to normal operation and the LCD screen will stop flashing. Once your pet moves away from the pet door the locks will close. 3. Finally, test the normal operation of the door. Again persuade your pet to put its head up to the door from the tunnel side. Try to make sure this is similar to how your pet would use it in practice, as shown below. The locks should open. 4. Repeat the learn process for each of your pets. 3 Contents Important Notice 3 1. Box Contents 4 2. User Interface 5 3. Introduction 6 4. Microchip Type 7 5. The SureFlap RFID Collar Tag 7 6. Learn Mode 8 7. Installation 9 8. Batteries and Low Battery Indicator 19 9. Operation 20 10. Locking Modes 20 11. Curfew Mode 21 12. Memory Wipe 22 13. Use As A Non-Selective Pet door 22 14. Custom Modes 22 15. Maintenance 24 16. Troubleshooting 25 17. Warranty & Disclaimer 27 4 1. Box Contents 1. Main Door Assembly (inside house) 2. External Frame (outside house) 3. Battery Compartment (one on each side) 4. Battery Covers x 2 5. Button Cover 6. Buttons (see User Interface for more information) 7. LCD Screen (see User Interface for more information) 8. Indicator Light 9. Double Locking Mechanism 10. Draught Excluder 11. Selection of Screws 12. Screw Caps 13. Collar Tag 8 1 6 5 7 3 4 10 9 2 121113 5 2. User Interface 2.1 Buttons 1. Lock Mode Button 2. Time Set/Current Time Button 3. Lock Time Button 4. Unlock Time Button 5. Learn Button Fn (Function) – See Custom Modes (section 14) 2.2 LCD Screen 1 2 3 4 5 Locking Mode In Locking Mode Out Time DisplayBattery Indicator Microchip Reader Enabled Current Time Lock Time Unlock Time 6 3. Introduction Congratulations on your purchase of the SureFlap Microchip Pet Door. This pet door has been designed to recognise either the microchip already implanted in your pet or the SureFlap RFID Collar Tag (one included – packs of two sold separately), allowing access to your pet whilst keeping out intruder animals. Your home becomes a secure environment for your pet, leading to a happier, more relaxed animal. Operation of the SureFlap Microchip Pet Door couldn’t be simpler. Once the batteries have been inserted, the door can be put into learn mode. The next pet to pass through the door from either direction, or to put its head into the tunnel with its nose up to the door, will have its microchip or collar tag number stored in the memory. Now the pet door is ready to install and will unlock whenever your pet wants to come into the house. Multiple pets are no problem. Up to 32 pets can be programmed into the pet door at the same time – more than enough for most people’s needs! The SureFlap Microchip Pet Door has all the features you would expect from a high quality pet door, including: • Robust and elegant design • Learn mode for programming multiple pets • Double lock mechanism • Curfew mode: program the door to lock and unlock at specified times • Low battery indicator • Typical battery lifetime at least 6 months 1 We wish you years of trouble-free operation with your SureFlap Microchip Pet Door and hope you enjoy the benefits it brings to your home and pet. 1 Based on normal usage. Note that heavy usage by many cats may reduce battery lifetime. 7 4. Microchip Type The SureFlap Microchip Pet Door is compatible with all microchips commonly used for pets. Specifically this includes: • 15-digit microchips (also known as FDXB) • 10-digit microchips (also known as FDXA and Trovan ® Unique) • 9-digit microchips (also known as Avid ® Secure/Encrypted) In addition to this the pet door is also compatible with the SureFlap RFID Collar Tag (one included - packs of two sold separately). Extensive tests have shown that the SureFlap Microchip Pet Door works perfectly with the vast majority of microchips. However a very small percentage of pets have a microchip without the required range for the pet door. In these rare cases please contact our customer service team for further assistance. If permanent changes to a door or wall are required for installation we strongly advise testing the SureFlap Microchip Pet Door with your pet(s) first. In order to test that it works with your pet(s) please carry out both the learn process (see section 6) and then test normal opera…
Text truncated - open the document above for the full version.
SureFlap Ltd 6 & 7 The Irwin Centre Scotland Road, Dry Drayton, Cambridge CB23 8AR UK [email protected] +44 (0)1954 211664 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: XO9-DOOR-1001 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram Schematics Operational Description Parts List SUR101 BlkDia.pdf SUR101 Schem.pdf SUR101 OpDes.pdf SUR101 PartsLst.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, N P R Hill
FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 1 Company No: 6399085 FCC details IC details FRN: 0019054196 IC Company No: 8906A FCC ID: XO9-DOOR-1001 Certification No: 8906A-DOOR1001 Model ID: SUR101 Model No: SUR101 External Photos Front View with Button Cover Back View Front View without Button Cover Top view FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 2 Company No: 6399085 Side View
FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 1 Company No: 6399085 FCC details IC details FRN: 0019054196 IC Company No: 8906A FCC ID: XO9-DOOR-1001 Certification No: 8906A-DOOR1001 Model ID: SUR101 Model No: SUR101 Label Location Figure 1: The compliance label will be moulded onto the plastic in the red box area. Label Artwork: Figure 2: Compliance label artwork. 14.0cm 2.75cm
FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 1 Company No: 6399085 FCC details IC details FRN: 0019054196 IC Company No: 8906A FCC ID: XO9-DOOR-1001 Certification No: 8906A-DOOR1001 Model ID: SUR101 Model No: SUR101 Label Sample Figure 1: The compliance label will be moulded onto the red box area. Label artwork: Figure 2: FCC label artwork. 2.75cm 14.0cm
FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 1 Company No: 6399085 FCC details IC details FRN: 0019054196 IC Company No: 8906A FCC ID: XO9-DOOR-1001 Certification No: 8906A-DOOR1001 Model ID: SUR101 Model No: SUR101 FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 2 Company No: 6399085 Internal Photos Front cover removed PCB cover removed FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 3 Company No: 6399085 FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 4 Company No: 6399085 Integrated Antenna FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 5 Company No: 6399085 Lock Cartridge Removed Motor in lock cartridge Motorised Lock (Back view) FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 6 Company No: 6399085 Display Board Top Display Board Bottom FCC ID: XO9-DOOR-1001 IC No: 8906A-DOOR1001 Sureflap Ltd. No: 6 & 7 The Irwin Centre, Scotland Road, Dry Drayton, Cambridge CB23 8AR, UK 7 Company No: 6399085 Main Board Top Main Board Bottom
|---------- ( Cambridge Ltd. ) ----------| Testing EMCEMC Consultancy EMC Training or : 01223 241140 (accounts) 23, Headington Drive, Cambridge. CB1 9HE Tel : 01954 251974 (test site) Fax : 01954 251907 email: [email protected] web : www.dbtechnology.co.uk REPORT ON ELECTROMAGNETIC COMPATIBILITY TESTS Performed at: TWENTY PENCE TEST SITE Twenty Pence Road, Cottenham, Cambridge U.K. CB24 8PS on Sureflap Ltd Sureflap dated 18th February 2013 Document History Initial release18/02/131 Approved by Revised by Description of modifications Affected page(s) DateIssue Based on report template: v090319 1 of 52 Page: Test Report T4610 Test No: FCC ID: X09-DOOR-1001 IC: 8906A-DOOR1001 R3196 1 Report No: Issue No: This report shall not be reproduced except in full, without the written approval of: dB Technology (Cambridge) Ltd. Equipment Under Test (EUT):Sureflap Test Commissioned by:Sureflap Ltd 7 The Irwin Centre Scotland Road Dry Drayton Cambridgeshire CB23 8AR Representative:Nick Hill Test Started:24th January 2013 Test Completed:5th February 2013 Test Engineer:Peter Barlow Date of Report:18th February 2013 Written by:Dave SmithChecked by:Derek Barlow Signature:Signature: Date:18th February 2013Date:18th February 2013 dB Technology can only report on the specific unit(s) tested at its site. The responsibility for extrapolating this data to a product line lies solely with the manufacturer. Test Standards Applied CFR 47Code of Federal Regulations: Pt 15 Subpart C - Radio Frequency Devices - Intentional Radiators RSS-210Licence-exempt Radio Apparatus (All Frequency Bands): Issue 8Category I Equipment 2 of 52 Page: Test Report T4610 Test No: FCC ID: X09-DOOR-1001 IC: 8906A-DOOR1001 R3196 1 Report No: Issue No: This report shall not be reproduced except in full, without the written approval of: dB Technology (Cambridge) Ltd. Emissions Test Results Summary CFR 47PASS TestPortMethodLimitPASS/FAILNotes Conductedac powerANSI C63.4:2003 15.207N/A#1 Emissions Radiated ANSI C63.4:2003 15.209PASS Emissions specs_fccv100412 #1This test was not applicable because the EUT was powered by an internal battery and has no means of connection to an ac power source. RSS-210PASS TestPortMethodLimitPASS/FAILNotes RadiatedenclosureANSI C63.4:2003 RSS_GENPASS Spurious Tables 5&6radiated Emissions specs_canadav111211 3 of 52 Page: Test Report T4610 Test No: FCC ID: X09-DOOR-1001 IC: 8906A-DOOR1001 R3196 1 Report No: Issue No: This report shall not be reproduced except in full, without the written approval of: dB Technology (Cambridge) Ltd. Contents 52 PLOT 33 Radiated Emissions - Typical Transmission Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 PLOT 32 Radiated Emissions - Bandwidth at 133kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 PLOT 31 Radiated Emissions - Bandwidth at 126kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 PLOT 30 Radiated Emissions - Sample F - 250MHz to 1GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 PLOT 29 Radiated Emissions - Sample F - 25MHz to 275MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 PLOT 28 Radiated Emissions - Sample E - 250MHz to 1GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 PLOT 27 Radiated Emissions - Sample E - 25MHz to 275MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 PLOT 26 Radiated Emissions - Sample D - 250MHz to 1GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 PLOT 25 Radiated Emissions - Sample D - 25MHz to 275MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 PLOT 24 Radiated Emissions - Sample C - 250MHz to 1GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 PLOT 23 Radiated Emissions - Sample C - 25MHz to 275MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 PLOT 22 Radiated Emissions - Sample B - 250MHz to 1GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 PLOT 21 Radiated Emissions - Sample B - 25MHz to 275MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 PLOT 20 Radiated Emissions - Sample A - 250MHz to 1GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 PLOT 19 Radiated Emissions - Sample A - 25MHz to 275MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 PLOT 18 Radiated Emissions - Sample F - 1.705MHz to 30MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 PLOT 17 Radiated Emissions - Sample F - 150kHz to 1.705MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 PLOT 16 Radiated Emissions - Sample F - 9kHz to 150kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 PLOT 15 Radiated Emissions - Sample E - 1.705MHz to 30MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 PLOT 14 Radiated Emissions - Sample E - 150kHz to 1.705MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 PLOT 13 Radiated Emissions - Sample E - 9kHz to 150kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 PLOT 12 Radiated Emissions - Sample D - 1.705MHz to 30MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 PLOT 11 Radiated Emissions - Sample D - 150kHz to 1.705MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 PLOT 10 Radiated Emissions - Sample D - 9kHz to 150kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 PLOT 9 Radiated Emissions - Sample C - 1.705MHz to 30MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 PLOT 8 Radiated Emissions - Sample C - 150kHz to 1.705MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 PLOT 7 Radiated Emissions - Sample C - 9kHz to 150kHz . . . . . . . . . . . . . . . . . . . . . . . . . . …
Text truncated - open the document above for the full version.
|---------- ( Cambridge Ltd. ) ----------| Testing EMCEMC Consultancy EMC Training or : 01223 241140 (accounts) 23, Headington Drive, Cambridge. CB1 9HE Tel : 01954 251974 (test site) Fax : 01954 251907 email: [email protected] web : www.dbtechnology.co.uk REPORT ON ELECTROMAGNETIC COMPATIBILITY TESTS Performed at: TWENTY PENCE TEST SITE Twenty Pence Road, Cottenham, Cambridge U.K. CB24 8PS on Sureflap Ltd Sureflap dated 18th February 2013 Document History Initial release18/02/131 Approved by Revised by Description of modifications Affected page(s) DateIssue Based on report template: v090319 1 of 3 Page: Test Photos T4610 Test No: FCC ID: X09-DOOR-1001 IC: 8906A-DOOR1001 R3196 1 Report No: Issue No: This report shall not be reproduced except in full, without the written approval of: dB Technology (Cambridge) Ltd. Contents 3 Photograph 2 Radiated Emissions - above 30MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Photograph 1 Radiated Emissions - below 30MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 of 3 Page: Test Photos T4610 Test No: FCC ID: X09-DOOR-1001 IC: 8906A-DOOR1001 R3196 1 Report No: Issue No: This report shall not be reproduced except in full, without the written approval of: dB Technology (Cambridge) Ltd. Photograph 1 Radiated Emissions - below 30MHz Photograph 2 Radiated Emissions - above 30MHz 3 of 3 Page: Test Photos T4610 Test No: FCC ID: X09-DOOR-1001 IC: 8906A-DOOR1001 R3196 1 Report No: Issue No: This report shall not be reproduced except in full, without the written approval of: dB Technology (Cambridge) Ltd.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.126 MHz - 0.1328 MHz | - |

A cat flap with an integrated short range RFID reader
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Pet drinking station with RFID microchip reader and 2.4 GHz wireless link
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Microchip Pet Feeder
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
SELECTIVE ENTRY PET DOOR
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz