Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Product Manual Felaqua™ Connect Model no. iCWS** 1 Thank you for choosing Felaqua Connect! The system is made up of three elements all working together to keep you connected to your pet and provide more insight into their drinking habits. The Felaqua Connect unit is the main component of the system. It recognises the microchip ID (already implanted in your pet) or the Sure Petcare RFID Collar Tag (purchase separately if required), allowing you to track when your pet drinks. The product has been specially designed to encourage cats to drink, presenting the water in a more natural and visible way. The Hub (sold separately) is the connected element of the system. It connects to your home internet and can talk to both the Felaqua Connect unit and your Sure Petcare App. By using the Sure Petcare App, you’ll be able to monitor the amount of water that your pet has drunk and how frequently they visit the Felaqua Connect unit each day. This will allow you to observe changes in their drinking habits over time. What’s in the box Please make sure you have all these parts* 1 Felaqua Connect unit 2 1 litre/34 fl oz reservoir 3 Drinking bowl * Batteries and Hub are not included EN Welcome to your new Felaqua™ Connect 1 3 2 In order for your Felaqua Connect to work with the Sure Petcare App, you will need to purchase an accompanying Hub. For more information on how to purchase a Hub please visit: surepetcare.com/hub 2 EN Contents Important safety information ..........................................................3 Product overview .............................................................................5 Microchip Felaqua Connect Connect system ..................................6 Hub Set up your Hub ..........................................................................7 Where to put your Hub ...............................................................8 Hub lights ....................................................................................9 Felaqua Connect Batteries .....................................................................................10 Where to put your Felaqua Connect ........................................11 Connect your Felaqua Connect .................................................12 Filling & replacing water ............................................................13 Adding your pet to the Felaqua Connect ..................................14 Introducing a cautious pet to the Felaqua Connect .................14 Cleaning & maintenance ...........................................................15 Help & support - the Hub ...........................................................16 Help & support - the Felaqua Connect......................................17 Warranty & disclaimer ...............................................................19 3 Important safety information WARNING: • Your Felaqua Connect is not a toy. Do not allow children to play with it. • Your Felaqua Connect includes some small components. To avoid the risk of choking take care to keep any loose parts away from young children and pets, or dispose of all packaging appropriately. • This product may be used by children aged from eight years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and user maintenance shall not be undertaken by children without supervision. CHILD PROOFING: In households with young children, you must include the Felaqua Connect in childproofing considerations. Misuse of this product by a child may result in persons coming into contact with potential dangers. Young children should be monitored at all times when in the immediate vicinity of the Felaqua Connect. BATTERIES: This product requires 4 x good quality 1.5 V LR14 alkaline C cells to operate. The product is not designed for use with rechargeable batteries. • Always change all four batteries at the same time and avoid mixing battery types. • To insert or change the batteries, remove the battery cover on the underside of the product to access the battery compartment. Ensure the +/- symbols on the new batteries match the symbols on the Felaqua Connect. • Non-rechargeable batteries are not to be recharged. • To avoid the risk of fire, always take care to ensure batteries are fitted the correct way round as marked on the Felaqua Connect and never short circuit the battery terminals. • If the batteries are exhausted or there is a problem with how they have been inserted, the light to the right of the reservoir will flash red every five seconds as a low battery indication. • There is a risk of explosion if the battery is replaced by an incorrect type. Always use good quality batteries from a reputable battery manufacturer to ensure the best performance. • Exhausted or out-of-date batteries must be removed and disposed of properly in accordance with local legislation. It is your responsibility to exercise discretion and observe all safety measures required by law and common sense. Please read the following information carefully and retain this manual for future reference. Note this product is intended for indoor use by domestic pets only. 4 EN • If the product is to be stored unused for a long period, the batteries must be removed and the water reservoir should be emptied and cleaned. In case of battery leaks, wear appropriate protective equipment (PPE) to protect yourself from any exposure to harmful chemicals before disposing of the batteries and cleaning any spillage. When cleaning up a spillage, avoid contact with skin, eyes or any risk of ingestion. Contact a medical professional immediately if this should occur. IMPORTANT: There are no user serviceable parts in the enclosure. Ensure any spilt water is mopped up in a timely fashion. PETS: To ensure your pet's safety • Do not use this product if parts are mi…
Text truncated - open the document above for the full version.
Quick Start Guide Felaqua™ Connect Model no. iCWS** EN: Quick Start Guide 1-4 DE: Schnellstartanleitung 5-8 FR: Guide de démarrage rapide 9-12 NL: Snelstartgids 13-16 ES: Guía de inicio rápido 17-20 IT: Guida rapida all'utilizzo 21-24 PT: Guia de Início Rápido 25-28 FI: Pika-aloitusopas 29-32 SV: Snabbstartsguide 33-36 PL: Skrócona instrukcja obsługi 37-40 HU: Gyors üzembehelyezési útmutató 41-44 1 2 123 4 E F G A D B C 1234 3 surepetcare.com/support surepetcare.com/pdf 1 EN Welcome to your new Felaqua™ Connect 1 What’s in the box? Please make sure you have all these parts: 1 Felaqua Connect unit 2 Reservoir 3 Drinking bowl Batteries and Hub are not included. For your Sure Petcare Felaqua Connect to work as a connected system you will need an accompanying Hub. For more information on how to purchase a Hub please visit: surepetcare.com/hub Before using the product, please download and read the user instructions available at: surepetcare.com/pdf 2 Download the app and follow the setup instructions Download the Sure Petcare App from the App Store or Google Play and follow the instructions for: • Connecting your Sure Petcare product • Where to locate your Felaqua Connect • Adding your pets to Felaqua Connect Already have the Sure Petcare App? You can add Felaqua Connect to your existing Household by clicking it in the app menu. 3 Fitting the batteries Always use 4 x good quality 1.5 V LR14 alkaline C cell batteries for best performance. For all battery safety information see page 2. Low battery indication: If the batteries are low, or there’s a problem with how they’ve been inserted, the LED to the right of the reservoir will flash red every 5 seconds. 4 Product overview AWater valve BRemovable bowl with improved water presentation CBattery compartment DRemovable reservoir 1 litre/34 fluid ounce ELED FConnect button GWeighing feet 2 EN It is your responsibility to exercise discretion and observe all safety measures required by law and common sense. Please read the following information carefully and retain this manual for future reference. Note this product is intended for indoor use only by domestic pets. WARNING: • Your Felaqua Connect is not a toy. Do not allow children to play with it. • Your Felaqua Connect includes some small components. To avoid the risk of choking take care to keep any loose parts away from young children and pets, or dispose of all packaging appropriately. • This product may be used by children aged from 8 years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and user maintenance shall not be undertaken by children without supervision. CHILD PROOFING: In households with young children, you must include the Felaqua Connect in childproofing considerations. Misuse of this product by a child may result in persons coming into contact with potential dangers. Ensure your Felaqua Connect is located where it will not pose a trip hazzard. Young children should be monitored at all times when in the immediate vicinity of Felaqua Connect. BATTERIES: This product requires 4 x good quality 1.5 V LR14 alkaline C cells to operate. The product is not designed for use with rechargeable batteries. • Always change all 4 batteries at the same time and avoid mixing battery types. • To insert or change the batteries, remove the battery cover on the underside of the product to access the battery compartment. Ensure the +/- symbols on the new batteries match the symbols on Felaqua Connect. • Non-rechargeable batteries are not to be recharged. • To avoid the risk of fire, always take care to ensure batteries are fitted the correct way round as marked on the Felaqua Connect and never short circuit the battery terminals. • If the batteries are exhausted or there is a problem with how they have been inserted, the light to the right of the reservoir will flash red every 5 seconds as a low battery indication. • There is a risk of explosion if the battery is replaced by an incorrect type. Always use good quality batteries from a reputable battery manufacturer to ensure the best performance. • Exhausted or out-of-date batteries must be removed and disposed of properly in accordance with local legislation. • If the appliance is to be stored unused for a long period, the batteries must be removed and the water reservoir should be emptied and cleaned. In case of battery leaks, wear appropriate protective equipment (PPE) to protect yourself from any exposure to harmful chemicals before disposing of the batteries and cleaning any spillage. When cleaning up a spillage, avoid contact with skin, eyes or any risk of ingestion. Contact a medical professional immediately if this should occur. IMPORTANT: There are no user serviceable parts in the enclosure. Only use approved Sure Petcare accessories and spare parts with your iCWS. Ensure any spilt water is mopped up in a timely fashion. Ensure the unit is stable and placed on a horizontal floor. PETS: To ensure your pet’s safety • Do not use this product if parts are missing, damaged or worn. • Wash the reservoir and bowl before first use and before refilling. Important information 12 3 456 3 • Use only tap water in your Felaqua Connect and replace the water with clean tap water daily. Sure Petcare recommends the Felaqua Connect is used with your pet’s implanted microchip, however it may also be operated using the Sure Petcare RFID Collar Tag. If using a collar tag, it must be used with a safety collar which incorporates a breakaway buckle. Sure Petcare cannot accept liability for any injury or death caused by a pet’s collar. The accuracy of the product and application is not intended to match medical, veterinary or scientific measurement devices. Filling and replacing water Cleaning & maintenance It is good practice to change your pet’s water daily to e…
Text truncated - open the document above for the full version.
SureFlap Ltd Ground floor, Building 2020 Cambourne Business Park, Cambourne, Cambridgeshire, UK CB23 6DW 11 th January 2021 FCC Number: XO9-ICWS001 Subject: Authorisation Letter To whom it may concern, This is to certify that SureFlap Ltd hereby authorises TUV SUD to act as the TCB for the application of the Felaqua Connect, FCC ID: XO9-ICWS001 to the FCC. We certify that we are not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 Of the Anti-Drug Abuse Act Of 1988, 21 U.S.C. § 862 because Of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. Yours faithfully, Dr. David Hallas, Managing Director
Federal Communications Commission Authorization and Evaluation Division 21 st April 2021 Subject: Confidentiality Request re application for certification of FCC ID: XO9-ICWS001 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name(s) Block Diagram ICWS block diagram. Part List 01633-EB_03 Poseidon Main PCB eBOM 01759-EB_01 Poseidon flying lead LED eBOM iCWS001WT_02 Poseidon Top Level BOM (Online Version) Mechanical parts list 01645-FG_01 Poseidon Main PCB Gerbers 01645-FG_01 Poseidon Main PCB Gerbers 01675-FG_01 Poseidon Capacitive Proximity Sensor PCB Gerbers ICWS copper images Poseidon Rev 01 Schematics The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Yours faithfully, David Hallas Managing Director
Model No.: iCWS FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Page 1 of 8 Product Images General Product image Shown with bowl and reservoir fitted. Model No.: iCWS FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Page 2 of 8 Front view Base unit only Model No.: iCWS FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Page 3 of 8 Lefthand side view Base unit only Model No.: iCWS FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Page 4 of 8 Righthand side view Base unit only Model No.: iCWS FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Page 5 of 8 Rear view Base unit only Model No.: iCWS FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Page 6 of 8 Top view Base unit only Model No.: iCWS FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Page 7 of 8 Top view with bowl Model No.: iCWS FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Page 8 of 8 Front view with bowl and reservoir Underside view
Page 1 of 2 Model ID: iCWS FCC Details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED Details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Product Compliance Text area Embossed on underside of Unit below the battery compartment. This area includes the FCC and IC Certification numbers Page 2 of 2 Product Compliance Markings Embossed on underside of Unit above the battery compartment. Compliance text area Product compliance Markings
FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 Model ID: iCWS ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Model No.: iCWS Page 1 of 6 SureFlap Ltd. Trading as Sure Petcare • Company No. 06399085 Product Internal Images General Product internals image FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 Model ID: iCWS ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Model No.: iCWS Page 2 of 6 SureFlap Ltd. Trading as Sure Petcare • Company No. 06399085 Internals showing capacitive sensor and PCB location FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 Model ID: iCWS ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Model No.: iCWS Page 3 of 6 SureFlap Ltd. Trading as Sure Petcare • Company No. 06399085 Top side of capacitive sensor Reverse side of the Capacitive sensor FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 Model ID: iCWS ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Model No.: iCWS Page 4 of 6 SureFlap Ltd. Trading as Sure Petcare • Company No. 06399085 Detail of LED location and winding on deck moulding FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 Model ID: iCWS ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Model No.: iCWS Page 5 of 6 SureFlap Ltd. Trading as Sure Petcare • Company No. 06399085 Detail of main PCB location FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 Model ID: iCWS ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Model No.: iCWS Page 6 of 6 SureFlap Ltd. Trading as Sure Petcare • Company No. 06399085 Reverse side of PCB top side of PCB
:,1',1*6,1727$/ :,1',1*621/2:(552: :,1',1*621833(552: 6833257,1*5,%6 72+2/':,5( 75$,/,1*:,5(6 PP PP $663(&,),(',1 3$57'5$:,1* 7$3(29(57+(),567:,1',1*72 6723,7)520)250,1*$*$3 6)+$9(86(''28%/(6,'('7$3( 81'(51($7+:,1',1*$1'6,1*/( 6,'('7$3(29(5 +<72(67$%/,6+:+$7:25.6 :,7+7+(,5:,1',1*0$&+,1(72 .((3:,1',1*$66(0%/<67$%/( 67$57,1*326,7,212)),567:,1',1* 7+(:,5(6+28/'%($66(0%/('$6 6+2:17267$577+(),567:,1',1* 7+(75$,/,1*:,5(:,//1(('72%( 3/$&('2872)7+(:$<:+(1:,1',1* ),567:,1',1*5287( 7+(:,5(6+28/'/,($/21*7+(5,%66+2:1 :,7+5('$552:67+,66+28/'%('21( 81'(57(16,21 7+()2//2:,1*:,1',1*66+28/'5(67 $*$,1677+,6:,5(7,*+7/< :,1',1*'(7$,/21+2235,%6 7+(),567:,1',1*66+28/'/,( %(7:((17+(+2235,%6$1'7+(/$67 :,1',1*66+28/'/,(217+(QG5,% 7+(%/8($552:,1',&$7(67+$77+( *$3&5($7('%<7+(5,%6+28/'127*2 )$53$677+,632,17 ),1,6+(':,1',1*6 $//:,1',1*66+28/'%(7,*+7:,7+12 *$36$1'6+28/'+$9(12 29(5/$33,1*$&52667+($66(0%/< 5HY,QLWLDOUHOHDVHIRUSUHSLORW 5HY(&11R'DWH&KDQJHGE\ -%UXQWRQ ,7(0123$57180%(5 5HYLVLRQ '(6&5,37,2147< '& 'HFN '& $QWHQQDZLQGLQJ 3DUW1XPEHU 'HVFULSWLRQ 0DWHULDO 7\SH )LQLVK &RDWLQJ 'UDZQE\ 6XSHUFHGHV&RORXU 6FDOH 8QLWV )RUPDW3URGXFW 7KLUG$QJOH3URMHFWLRQ &KDQJHV 7HPSODWH6XUH3HWFDUH$ODQGVFDSH 6ROLG:RUNV'UDZLQJ 0RGHO)LOHQDPH 'HFN:LQGLQJ$VVHPEO\ $ 6XUH3HWFDUH 7KH,UZLQ&HQWUH 6FRWODQG5RDG'U\'UD\WRQ &DPEULGJH&%$58. 7HO LQIR#VXUHSHWFDUHFRP ZZZVXUHSHWFDUHFRP PP RI -%UXQWRQ 3RVHLGRQ '$ '$ *UDGH,, 2YHU 0DWHULDO *UDGH 1$ 7ROHUDQFHVXQOHVV RWKHUZLVHVSHFLILHG 6KHHW &21),'(17,$/'21276&$/( &RS\ULJKW6XUHIODS/WGWUDGLQJDV6XUH3HWFDUH 8SWR $QJXODU 0DWHULDO 0DQXIDFWXUHU 1$ 1$ 1$ 1$ 5HYLVLRQ PPñ J 9ROXPH :HLJKW ) ( '' && %% $$
FCC details FRN: 0019054196 FCC ID: XO9-ICWS001 ISED details IC Company No.: 8906A Certification No.: 8906A-ICWS001 Model No.: iCWS Page 1 of 1 iCWS Operational Description The device is a pet water station with integrated scales and an RFID reader that operates at 126 kHz or 133 kHz. The reader is normally used together with a sub-dermal RFID implant in the pet that is not provided with the product. The unit also has a 2.4 GHz 802.15.4 RF transceiver to communicate with a user app via a Sure Petcare iHB internet Hub. Both antennas are integrated into the plastic enclosure and may not be modified by the user. The Hydration station has a bowl and reservoir arrangement with a mechanical valve that presents a puddle of water to the pet for drinking from. The reservoir valve design allows the water level in the “puddle” to be maintained at an appropriate level during the day while water is drunk. The unit also has an integral weight reporting function so the unit can continuously monitor the weight of the water in the unit and record how much water is drunk. The hydration station incorporates a capacitive proximity detector that monitors for the presence of the pet. When the pet’s presence has been determined then the RFID reader tries to read the tag ID number and compares it to a previously stored list. If the ID tag matches one of the stored codes then the units reports the amount of water drunk back to the app along with the pet’s ID. When a Pet’s ID tag is not identified then any water drunk is reported as being by an “unidentified animal”. Weight changes over time when no animal is detected are automatically allowed for. The unit has a single button which can be used to enable the unit to learn RFID tags as required. The feeder has a main LED which is used to indicate various states of the feeder, for example when it has read an ID tag and is opening or when it is in learn mode. The device is battery powered by 4 x LR16 “C” cells and does not have any external connections.
TÜV SÜD, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100 Website: www.tuv-sud.co.uk COMMERCIAL-IN-CONFIDENCE SAR EXCLUSION DOCUMENT Approved by Date 16 April 2021 Ryan Henley Authorised Signatory ©2021 Not to be reproduced, except in its entirety, without the permission of TÜV SÜD Page 1 of 4 Document 75950067-16 Issue 01 126 kHz & 133 kHz Transmitters: FCC Standalone SAR Test Exclusion Considerations (KDB 447498 D01) Section 4.3.1 c) <100 MHz – Separation Distance ≤50 mm or Separation Distance >50 mm and <200 mm The 1g head or body SAR test exclusion thresholds for <100 MHz are determined by the following steps: Step a) Threshold result from Formula in Section 4.3.1 a); [(max power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] [√f (GHz) ] ≤ 3.0 for 1g SAR. • f (GHz) is the RF channel transmit frequency in GHz. • Power and distance are rounded to the nearest mW and mm before calculation. • The result is rounded to one decimal place for comparison • When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied. Step b) requires formula to be re-arranged to give power allowed at numeric threshold at 50 mm test separation distance and Step c) requires f (GHz) to be set to 100 MHz (0.1 GHz) giving: Step a) Power threshold = (3 * 50) / (√0.1) = 474.3 mW Step b) Threshold result from Formula in Section 4.3.1 b) 1); {[Power allowed at numeric threshold for 50 mm {Formula Step A})] + [(test separation distance – 50 mm)·(f (MHz) /150)]} mW • f MHz is the RF channel transmit frequency in MHz. • Power and distance are rounded to the nearest mW and mm before calculation. • The result is rounded to one decimal place for comparison Power threshold = 474.3 mW + [(test separation distance – 50 mm)·(f( MHz )/150)]} mW Step c) requires f (MHz) to be set to 100 MHz giving: Step b) Power threshold = 474.3 mW + [(test separation distance – 50 mm)·(100)/150)] mW ©2021 Not to be reproduced, except in its entirety, without the permission of TÜV SÜD Page 2 of 4 Document Number: 75950067-16 | Issue: 01 COMMERCIAL-IN-CONFIDENCE Step c) 1) Threshold result from Formula in Section 4.3.1 c) 1); >50 mm and <200 mm Threshold result from Formula in Section 4.3.1 b) 1) is multiplied by [1+log(100/f MHz )] Power threshold = [474.3 mW + (test separation distance – 50 mm)· (100)/150)] * [1+log(100/f MHz )] mW • f MHz is the RF channel transmit frequency in MHz. • Power and distance are rounded to the nearest mW and mm before calculation. • The result is rounded to one decimal place for comparison Step c) 2) Threshold result from Formula in Section 4.3.1 c) 2); ≤50 mm Threshold result from the formula in 4.3.1 c) 1) above for >50 mm and <200 mm for 50 mm and 100 MHz is multiplied by 0.5. Power threshold = [474.3 mW + (50 mm – 50 mm)· (100)/150)] * [1+log(100/f MHz )] * 0.5 mW Which simplifies to: Power threshold = 474.3 mW * [1+log(100/f MHz )] * 0.5 mW • f MHz is the RF channel transmit frequency in MHz. • Power and distance are rounded to the nearest mW and mm before calculation. • The result is rounded to one decimal place for comparison>> SAR Exclusion Result (1 g Head or Body) Frequency (MHz) Power Output mW Duty Cycle % Maximum Power (Tune up Value) * (mW) Test Separation Distance (mm) SAR Exclusion Power Threshold Section 4.3.1 c) (mW) SAR Test Exclusion (Yes/No) 0.126 116 100 116 0 924.9 Yes 0.133 95 100 95 0 919.3 Yes SAR Exclusion Result (10 g Extremity) Frequency (MHz) Power Output mW Duty Cycle % Maximum Power (Tune up Value) * (mW) Test Separation Distance (mm) SAR Exclusion Power Threshold Section 4.3.1 c) (mW) SAR Test Exclusion (Yes/No) 0.126 116 100 116 0 2312.2 Yes 0.133 95 100 95 0 2298.3 Yes *Maximum power including tolerance of the time averaged declared conducted output power of the device. Derived from FCC Determination of the Equivalent Isotropically Radiated Power (EIRP) given in the measurement and calculations overleaf. The SAR exclusion threshold has been evaluated using the formula described above from information supplied by the manufacturer below. Based on the calculation above, the EUT is categorically excluded from SAR testing ©2021 Not to be reproduced, except in its entirety, without the permission of TÜV SÜD Page 3 of 4 Document Number: 75950067-16 | Issue: 01 COMMERCIAL-IN-CONFIDENCE FCC Determination of the Equivalent Isotropically Radiated Power (EIRP) of an RF Transmitting System (KDB 412172) Section 2.2 Direct calculation from the DUT power measured in a radiated test configuration Section 2.2. states: When the DUT power is measured using a radiated test configuration, the eirp can be directly determined using the field strength (linear) approach by applying Equation: eirp = p t x g t = (E x d) 2 /30 • Eirp is the equivalent isotropically radiated power in watts. • p t transmitter output power in watts (not required) • g t numeric gain of the transmitting antenna (unitless) (not required) • E electric field strength in V/m • D measurement distance in meters (m) Measure the electric field strength E at test distance d m. If magnetic field strength is measured, convert to electric field strength in accordance with the antenna manufacturers’ conversion factors. Calculate the eirp using the equation above. Increase the eirp to include any declared tune-up tolerance value to give the maximum output power. The result is the Maximum Power (Tune up Value) required in the SAR exclusion assessment. Frequency kHz Magnetic Field Strength 1 (dBμA/m) Conversion Factor H to E Field 2 (dB) Electric Field Strength (dBμV/m) Electric Field Strength (V/m) Test Distance (m) Eirp (W) Eirp (mW) Tune-up Tolerance (%) Maximum Power (Tune up Value) (mW) 126 64.34 51.5 115.8 0.6194411 3 0.11511 115.11 0 115.1 133 63.47 51.5 115.0 0.5604024 3 0.09422 94.22 0 94.2 Note 1: Maximum magnetic field strength measured at 3 m from report 75950067_04. Note 2: Since Electric and magnetic fields …
Text truncated - open the document above for the full version.
TÜV SÜD is a trading name of TUV SUD Ltd Registered in Scotland at East Kilbride, Glasgow G75 0QF, United Kingdom Registered number: SC215164 TUV SUD Ltd is a TÜV SÜD Group Company Phone: +44 (0) 1489 558100 Fax: +44 (0) 1489 558101 www.tuv-sud.co.uk TÜV SÜD Octagon House Concorde Way Fareham Hampshire PO15 5RL United Kingdom TÜV SÜD SIGNATURE NAME JOB TITLE RESPONSIBLE FOR ISSUE DATE Matthew Russell RF Team Leader Authorised Signatory 14 April 2021 Signatures in this approval box have checked this document in line with the requirements of TÜV SÜD document control rules. ENGINEERING STATEMENT The measurements shown in this report were made in accordance with the procedures described on test pages. All reported testing was carried out on a sample equipment to demonstrate limited compliance with FCC 47 CFR Part 15C. The sample tested was found to comply with the requirements defined in the applied rules. RESPONSIBLE FOR NAME DATE SIGNATURE Testing Graeme Lawler 14 April 2021 FCC Accreditation 90987 Octagon House, Fareham Test Laboratory EXECUTIVE SUMMARY A sample of this product was tested and found to be compliant with FCC 47 CFR Part 15C: 2019 for the tests detailed in section 1.3. FCC Test Report SureFlap Ltd Pet Drinking Station, Model: iCWS In accordance with FCC 47 CFR Part 15C (RFiD) Prepared for: SureFlap Ltd Ground floor, Building 2020 Cambourne Business Park, Cambourne, Cambridgeshire, CB23 6DW United Kingdom FCC ID: XO9-ICWS001 COMMERCIAL-IN-CONFIDENCE Document 75950067-07 Issue 02 DISCLAIMER AND COPYRIGHT This non-binding report has been prepared by TÜV SÜD with all reasonable skill and care. The document is confidential to the potential Client and TÜV SÜD. No part of this document may be reproduced without the prior written approval of TÜV SÜD. © 2021 TÜV SÜD. This report relates only to the actual item/items tested. ACCREDITATION Our UKAS Accreditation does not cover opinions and interpretations and any expressed are outside the scope of our UKAS Accreditation. Results of tests not covered by our UKAS Accreditation Schedule are marked NUA (Not UKAS Accredited). Document 75950067-07 Issue 02 COMMERCIAL-IN-CONFIDENCE COMMERCIAL-IN-CONFIDENCE Page 1 of 22 Contents 1 Report Summary .....................................................................................................................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.126 MHz - 0.133 MHz | - |

A cat flap with an integrated short range RFID reader
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Microchip Pet Feeder
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
SELECTIVE ENTRY PET DOOR
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
SELECTIVE ENTRY PET DOOR
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz