Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
WST-100 Keyfob Remote Rev. A Installation Instructions Product Summary This Keyfob remote provides users with convenient options for the following system operations: _ Arm the system (doors, windows, and motion sensors) _ Arm the system with no entry delay _ Disarm the system _ Activate panic alarms The keyfob is lithium battery-powered and designed to fit on a keychain, in a pocket or purse. Programming For complete programming information, refer to the system installation instructions. Testing keyfob Remote Test the Keyfob Remote by pressing the buttons as described below: _ Unlock Button -disarms the system. Doors, windows, and motion sensors are disarmed. _ Lock Button - arms doors and windows. _ Lock and Unlock Buttons - when pressed simultaneously, activates a panic alarm. 60-659 _ Light Button β operates auxillary function. _ Star Button - performs EXIT button function. Specifications Power source: 3 V, 220 mAh CR2032 lithium battery Frequency: 433.92 MHz. Dimensions: L = 2.50β x W = 1.25β x H =.5β Typical battery life: 5 years Operating temperature range: 0Β° to 49Β° C Notices These devices comply with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. These devices may not cause harmful interference. 2. These devices must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Interactive Technologies, Inc. can void the usersβ authority to operate the equipment
/ Ecolink Intelligent Technology 2055 Corte Del Nogal Carlsbad, CA 92011 (760) 431-8804 Federal Communications Commi ssion 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: XQC-WSTI00 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission's rules (47 CFR $$ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission's policy, in order to comply with the marketing regulations in 47 CFR $2.803 and the importation rules in 47 CFR $2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments: Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and corespondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, Mike Bailey VP of Operations Ecolink Intel I igent technology 912812011
Ecolink Intelligent Technolory, Inc. 2055 Corte Del Nogal Carlsbad, CA 920f 1 (760) 431-8804 September 7,2011 Compliance Certifi cation Services Certification Division 47113 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize Ms. Claire Hoque/Application Examiner of Compliance Engineering Services, lnc., d.b.a. Compliance Certification Services and hereafter referred to as CCS, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Ms. Claire Hoque of CCS on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certifr that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing CCS as our agent, we still recognize that we are lesponsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Ceftification Division may consider misleading or unauthorized; upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; use certification only to indicate the products are certified as being in conformity with specified standards; endeavor to ensure that no certificate or report nor any part thereofis used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Cerlification Division; i)keep a record of all complaints made known to the us relating to the product's compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; document the actions taken. This authorrzatron is valid until further written notice from the applicant. Michael Bailey VP of Operations Ecolink IntelligentTechnology e) 0 s) i) k)
FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR WIRELESS SECURITY REMOTE KEYFOB MODEL NUMBER: WST-100 FCC ID: XQC-WST100 IC: 9863B-WST100 REPORT NUMBER: 11U13988 ISSUE DATE: 2011-08-23 (Revised: 2011-09-23) Prepared for ECOLINK 2055 CARTE DEL NOGAL CARLSBAD CA, 92011, USA Prepared by UNDERWRITERS LABORATORIES INC. 1285 WALT WHITMAN RD. MELVILLE, NY 11747, U.S.A. TEL: (631) 271-6200 FAX: (877) 854-3577 REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 2 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. Revision History Rev. Issue Date Revisions Revised By -- 8/23/11 Initial Issue M. Antola 1 9/23/11 Updated report with IC ID number M. Antola REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 3 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 5 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 5 4.2. SAMPLE CALCULATION ............................................................................................ 5 4.3. MEASUREMENT UNCERTAINTY ............................................................................... 5 5. EQUIPMENT UNDER TEST ............................................................................................... 6 5.1. DESCRIPTION OF EUT .............................................................................................. 6 5.2. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 6 5.3. SOFTWARE AND FIRMWARE .................................................................................... 6 5.4. WORST-CASE CONFIGURATION AND MODE .......................................................... 6 5.5. MODIFICATIONS ........................................................................................................ 6 5.6. DESCRIPTION OF TEST SETUP ................................................................................ 7 6. TEST AND MEASUREMENT EQUIPMENT ....................................................................... 9 7. ANTENNA PORT TEST RESULTS ...................................................................................10 7.1. 20 dB AND 99% BW ...................................................................................................10 7.2. DUTY CYCLE .............................................................................................................14 7.3. TRANSMISSION TIME ...............................................................................................18 8. RADIATED EMISSION TEST RESULTS...........................................................................19 8.1. TX RADIATED SPURIOUS EMISSION ......................................................................19 9. SETUP PHOTOS ...............................................................................................................26 REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 4 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: ECOLINK 2055 CORTE DEL NOGAL CARLSBAD, CA, 92011, USA EUT DESCRIPTION: Wireless Security Remote Key Fob MODEL: WST-100 SERIAL NUMBER: Non-serialized prototype DATE TESTED: 2011-08-17 to 2011-08-18 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C Pass INDUSTRY CANADA RSS-210 Issue 8, Annex 1 Pass INDUSTRY CANADA RSS-GEN Issue 3 Pass Underwriters Laboratories Inc. tested the RF Exposure of the above equipment in accordance with the requirements set forth in the above standards, using test results reported in the test report documents referenced below and/or documentation furnished by the applicant. All indications of Pass/Fail in this report are opinions expressed by Underwriters Laboratories Inc. based on interpretations of these calculations. The results show that the equipment is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation, as described by the referenced documents. This document may not be altered or revised in any way unless done so by Underwriters Laboratories Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by Underwriters Laboratories Inc. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Approved & Released For UL By: Tested By: Bob DeLisi Mike Antola Senior Staff Engineer Senior Project Engineer UL UL REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23β¦
Text truncated - open the document above for the full version.
REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 26 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. 9. SETUP PHOTOS ANTENNA PORT REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 27 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. RADIATED EMISSION FOR PORTABLE CONFIGURATION β X ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION β X ORIENTATION REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 28 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. RADIATED EMISSION FOR PORTABLE CONFIGURATION β Y ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION β Y ORIENTATION REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 29 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. RADIATED EMISSION FOR PORTABLE CONFIGURATION β Z ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION β Z ORIENTATION REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 30 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. RADIATED EMISSION BELOW 1 GHz RADIATED EMISSIONS BELOW 1GHz (FRONT) REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 31 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. RADIATED EMISSIONS BELOW 1GHz (BACK) REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 32 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. RADIATED EMISSION ABOVE 1 GHz RADIATED EMISSIONS ABOVE 1 GHz (FRONT) REPORT NO: 11U13988 DATE: 2011-08-23 (Revised: 2011-09-23) FCC ID: XQC-WST100 IC: 9863B-WST100 Page 33 of 33 UNDERWRITERS LABORATORIES INC. FORM NO: CCSUP4701D 1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA TEL: (631) 271-6200 FAX: (877) 854-3577 This report shall not be reproduced except in full, without the written approval of Underwriters Laboratories Inc. END OF REPORT RADIATED EMISSIONS ABOVE 1 GHz (BACK)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

Wearable Action Button
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Flood and Freeze Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Motion Detector
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Motion Detector
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Audio Detector
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter