FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ecolink Intelligent Technology, Inc./
  3. XQC-WST232

XQC-WST232WIRELESS SENSOR

Ecolink Intelligent Technology, Inc.

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Feb 22, 2015
Application Purpose
Original Equipment
Date of Application
Feb 22, 2015
Equipment Note
WIRELESS SENSOR
Frequency Range
345.00000000 - 345.00000000
Company
Ecolink Intelligent Technology, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WST-232 Wireless Contact Specifications Frequency: 345MHz Operating Temperature: 32°-120°F (0°-49°C) Battery: 3V lithium CR2032 Operating Humidity: 5-95% RH non condensing Battery life: 5-8 years Compatible with Honeywell receivers Magnet gap: 5/8 th inch max Supervisory signal interval: 60 min(approx.) Enrolling To enroll the sensor, set your panel into program mode, refer to your specific alarm panel manual for details on these menus. When prompted by the panel, trigger the sensor by moving the magnet in and out of range of the sensor. The panel will beep when you have successfully learned in a sensor. Mounting Included with the contact is double sided tape for the contact and the magnet. For reliable bonding ensure the surface is clean and dry. Apply the tape to the sensor and then to the desired location. Apply firm pressure for several seconds. It is not recommended to mount the tape at temperatures below 50°F, although after 24 hours the bond will hold at low temperatures. The WST-232 may also be mounted with screws if desired. One side of the sensor is marked with 3 lines; this indicates the location of the reed switch. The magnet should be mounted facing this side of the sensor, and it must be no further than 5/8 of an inch from the sensor. An external contact may also be connected to the WST-232 with the supplied wiring connector. Interchangeable covers The contact comes from the factory assembled with a white cover, but included are optional brown covers. To change the cover, slide the front cover to disengage it from the sensor then remove. Replace with the brown cover ensuring the Top (as marked on the inside of the cover) points away from the battery. You should hear a click when the cover engages and disengages from the sensor. You do not need to replace the back plastic because once mounted the back is not visible. To replace the magnet cover you will need to gently pry the white cover off with a flat head screw driver and snap the brown cover in place. Replacing the Battery When the battery is low a signal will be sent to the control panel. To replace the battery: 1. Slide the top cover to disengage it from the sensor, then remove it to reveal the battery. 2. Replace with a CR2032 battery ensuring the + side of the battery faces towards you. 3. Re-attached the cover, ensure the Top (as marked on the inside of the cover) points away from the battery. You should hear a click when the cover engages properly. Note: Removing the cover will trigger a zone tamper signal to the control panel FCC Compliance Statement This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment to an outlet on a different circuit from the receiver • Consult the dealer or an experienced radio/TV contractor for help. Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de la dispositif. FCC ID:XQC-WST232 IC: 9863B-WST232 Warranty Ecolink Intelligent Technology Inc. warrants that for a period of 5 years from the date of purchase that this product is free from defects in material and workmanship. This warranty does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications. If there is a defect in materials and workmanship under normal use within the warranty period Ecolink Intelligent Technology Inc. shall, at its option, repair or replace the defective equipment upon return of the equipment to the original point of purchase. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Ecolink Intelligent Technology Inc. neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. The maximum liability for Ecolink Intelligent Technology Inc. under all circumstances for any warranty issue shall be limited to a replacement of the defective product . It is recommended that the customer check their equipment on a regular basis for proper operation. © 2012 Ecolink Intelligent Technology Inc. PN WST212 R1.00 2055 Corte Del Nogal Carlsbad, California 92011 1-855-632-6546 www.discoverecolin…

Text truncated - open the document above for the full version.

Cover Letter(s)

2055 Corte Del Nogal Carlsbad, CA 92011 (760) 431-8804 Date: 2/11/2015 UL Verification Services Inc. 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Verification Services Inc. as our representative, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the product’s compliance with requirements of the relevant standard and to make these records available to the when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Jay Stone Director of Engineering Ecolink Intelligent Technology REMARK: 1. This authorization letter will be sent along with your application when filing with UL Verification Services Inc. 2. Please follow the format and type it on company letterhead and send original to us. 3. Authorized signature must be in agreement with grantee code contact in FCC database and Industry Canada contact information.

Test Report

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS 210 CERTIFICATION TEST REPORT FOR WIRELESS SENSOR MODEL NUMBER: WST-232 FCC ID: XQC-WST232 IC: 9863B-WST232 REPORT NUMBER: 14U19725 REVISION B ISSUE DATE: FEB 19, 2015 Prepared for ECOLINK INTELLIGENT TECHNOLOGY, INC. 2055 CORTE DEL NOGAL CARLSBAD CA, 92011, U.S.A Prepared by UL VERIFICATION SERVICES INC. 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888 REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 2 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. Revision History Rev. Issue Date Revisions Revised By -- 2/10/15 Initial Issue P. ZHANG A 2/18/15 Updated page 22 P. ZHANG B 2/19/15 Updated page 26 average reading calculation P. ZHANG REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 3 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 5 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 5 4.2. SAMPLE CALCULATION ............................................................................................ 5 4.3. MEASUREMENT UNCERTAINTY ............................................................................... 6 5. EQUIPMENT UNDER TEST ............................................................................................... 7 5.1. DESCRIPTION OF EUT .............................................................................................. 7 5.2. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 7 5.3. SOFTWARE AND FIRMWARE .................................................................................... 7 5.4. WORST-CASE CONFIGURATION AND MODE .......................................................... 7 5.5. MODIFICATIONS ........................................................................................................ 7 5.1. DESCRIPTION OF TEST SETUP ................................................................................ 8 6. TEST AND MEASUREMENT EQUIPMENT ......................................................................10 7. ANTENNA PORT TEST RESULTS ...................................................................................11 7.1. 20 dB AND 99% BW ...................................................................................................11 7.2. DUTY CYCLE .............................................................................................................15 7.3. TRANSMISSION TIME ...............................................................................................21 8. RADIATED EMISSION TEST RESULTS...........................................................................22 8.1. TX RADIATED SPURIOUS EMISSION ......................................................................22 9. SETUP PHOTOS ...............................................................................................................30 REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 4 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: ECOLINK INTELLIGENT TECHNOLOGY, INC. 2055 CORTE DEL NOGAL CARLSBAD, CA, 92011, U.S.A EUT DESCRIPTION: WIRELESS SENSOR MODEL: WST-232 SERIAL NUMBER: NON-SERIALIZED PRODUCTION UNIT. DATE TESTED: FEB 2 - 10, 2015 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C Pass INDUSTRY CANADA RSS-210 Issue 8, Annex 1 Pass INDUSTRY CANADA RSS-GEN Issue 4 Pass UL Verification Services Inc tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL Verification Services Inc will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Approved & Released For UL Verification Services Inc By: Tested By: PENG ZHANG CHARLES VERGONIO PROJECT LEAD LAB ENGINEER UL Verification Services Inc. UL Verification Services Inc. REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: …

Text truncated - open the document above for the full version.

Test Setup Photos

REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 30 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. 9. SETUP PHOTOS ANTENNA PORT ANTENNA PORT REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 31 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 32 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 33 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 34 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION BELOW 30 MHz RADIATED EMISSIONS BELOW 30MHz (FRONT) REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 35 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSIONS BELOW 30MHz (BACK) REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 36 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION ABOVE 30 MHz RADIATED EMISSIONS ABOVE 30 MHz (FRONT) REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 37 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSIONS ABOVE 30 MHz (BACK) REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 38 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSIONS ABOVE 1000 MHz (FRONT) REPORT NO: 14U19725B DATE: FEB 19, 2015 FCC ID: XQC-WST232 IC:9863B-WST232 Page 39 of 39 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. END OF REPORT RADIATED EMISSIONS ABOVE 1000 MHz (BACK)

Contact Information

Applicant

Jay Stone
[email protected]760-431-8804Fax: 760-431-8975

Test Firm

UL Verification Services Inc. (formerly UL CCS)Jay Kogoma
[email protected]510-319-4135Fax: 000-000-0000

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231345 MHz - 345 MHz-
Confidentiality
Long Term

Other Applications from Ecolink Intelligent Technology, Inc.

Wearable Action Button - FCC ID XQC-WST132 - Ecolink Intelligent Technology, Inc.
XQC-WST132

Wearable Action Button

Feb 07, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Flood and Freeze Sensor - FCC ID XQC-WST621 - Ecolink Intelligent Technology, Inc.
XQC-WST621

Flood and Freeze Sensor

May 01, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Motion Detector - FCC ID XQC-WST740 - Ecolink Intelligent Technology, Inc.
XQC-WST740

Motion Detector

Jul 04, 2022

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Motion Detector - FCC ID XQC-WST742 - Ecolink Intelligent Technology, Inc.
XQC-WST742

Motion Detector

Feb 17, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Audio Detector - FCC ID XQC-CS602 - Ecolink Intelligent Technology, Inc.
XQC-CS602

Audio Detector

Feb 17, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter