FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ecolink Intelligent Technology, Inc./
  3. XQC-WST242

XQC-WST242Wireless Sensor

Ecolink Intelligent Technology, Inc.

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Aug 26, 2015
Application Purpose
Original Equipment
Date of Application
Aug 26, 2015
Equipment Note
Wireless Sensor
Frequency Range
345.00000000 - 345.00000000
Company
Ecolink Intelligent Technology, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WST-242 Outdoor Wireless Contact Specifications Frequency: 345 MHz Operating Temperature: -40°to 60°C Battery: 2X 1.5V AA Lithium Cell Operating Humidity: 5-95% RH non condensing Battery life: up to 10 years Compatible with Honeywell receivers Magnet gap: 3 inch max Supervisory signal interval: 60 min(approx.) Enrolling To enroll the sensor, set your panel into program mode, refer to your specific alarm panel manual for details on these menus. When prompted by the panel, trigger the sensor by moving the magnet in and out of range of the sensor. The panel will beep when you have successfully learned in a sensor. Mounting Use screws or cable ties to secure the contact and the magnet. One side of the sensor is marked with 3 lines; this indicates the location of the reed switch. The magnet should be mounted facing this side of the sensor, and it must be no further than 3 inches from the sensor. An external contact may also be connected to the WST-242 with the supplied wiring connector. Installing covers After installing the batteries, be sure to install the rubber insert and back cover to ensure a weather resistant seal before mounting outside. Replacing the Battery When the battery is low a signal will be sent to the control panel. To replace the battery: 1. Detach the sensor from the back mounting plate and remove it. 2. Remove the rubber insert and replace the Lithium AA batteries with the same type. 3. Re-install the rubber insert and re-fasten the sensor to the back mounting plate. Note: Removing the sensor from the mounting plate will trigger a zone tamper signal to the control panel. FCC Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment to an outlet on a different circuit from the receiver • Consult the dealer or an experienced radio/TV contractor for help. Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de la dispositif. FCC ID:XQC-WST242 IC: 9863B-WST242 Warranty Ecolink Intelligent Technology Inc. warrants that for a period of 5 years from the date of purchase that this product is free from defects in material and workmanship. This warranty does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications. If there is a defect in materials and workmanship under normal use within the warranty period Ecolink Intelligent Technology Inc. shall, at its option, repair or replace the defective equipment upon return of the equipment to the original point of purchase. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Ecolink Intelligent Technology Inc. neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. The maximum liability for Ecolink Intelligent Technology Inc. under all circumstances for any warranty issue shall be limited to a replacement of the defective product . It is recommended that the customer check their equipment on a regular basis for proper operation. © 2015 Ecolink Intelligent Technology Inc. PN WST242 R1.00 2055 Corte Del Nogal Carlsbad, California 92011 1-855-632-6546 www.discoverecolink.com

Cover Letter(s)

Ecolink Intelligent Technology, Inc. Page 1 of 2 2055 Corte Del Nogal Carlsbad, CA 92011 October 27, 2014 UL Verification Services Inc. Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize UL Verification Services Inc. to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Verification Services Inc. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL Verification Services Inc. as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner;

Cover Letter(s)

2055 Corte Del Nogal Carlsbad, CA 92011 (760) 431-8804 August 18, 2015 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: XQC-WST242 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request, for 180 days from date of equipment authorization, on the following attachments: Internal Photos External Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, Jay Stone 8/18/2015 Director of Engineering Ecolink Intelligent Technology, Inc.

ID Label/Location Info

Model #: WST-242 FCC ID: XQC-WST242 IC: 9863B-WST242 Label location on back of WST-242

Test Report

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS 210 CERTIFICATION TEST REPORT FOR WIRELESS SENSOR MODEL NUMBER: WST-242 FCC ID: XQC-WST242 IC: 9863B-WST242 REPORT NUMBER: 15U21470 ISSUE DATE: AUGUST 17, 2015 Prepared for ECOLINK INTELLIGENT TECHNOLOGY, INC. 2055 CORTE DEL NOGAL CARLSBAD CA, 92011, U.S.A Prepared by UL VERIFICATION SERVICES INC. 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888 REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 2 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. Revision History Rev. Issue Date Revisions Revised By - 8/17/15 Initial Issue P. Zhang REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 3 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 6 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 6 4.2. SAMPLE CALCULATION ............................................................................................ 6 4.3. MEASUREMENT UNCERTAINTY ............................................................................... 6 5. EQUIPMENT UNDER TEST ............................................................................................... 7 5.1. DESCRIPTION OF EUT .............................................................................................. 7 5.2. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 7 5.3. SOFTWARE AND FIRMWARE .................................................................................... 7 5.4. WORST-CASE CONFIGURATION AND MODE .......................................................... 7 5.5. MODIFICATIONS ........................................................................................................ 7 5.6. DESCRIPTION OF TEST SETUP ................................................................................ 8 6. TEST AND MEASUREMENT EQUIPMENT ....................................................................... 9 7. ANTENNA PORT TEST RESULTS ...................................................................................10 7.1. 20 dB AND 99% BW ...................................................................................................10 7.2. DUTY CYCLE .............................................................................................................14 7.3. TRANSMISSION TIME ...............................................................................................20 8. RADIATED EMISSION TEST RESULTS...........................................................................21 8.1. TX RADIATED SPURIOUS EMISSION ......................................................................21 9. SETUP PHOTOS ...............................................................................................................29 REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 4 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: ECOLINK INTELLIGENT TECHNOLOGY, INC. 2055 CORTE DEL NOGAL CARLSBAD, CA, 92011, U.S.A EUT DESCRIPTION: WIRELESS SENSOR MODEL: WST-242 SERIAL NUMBER: NON-SERIALIZED PRODUCTION UNIT. DATE TESTED: AUGUST 16-17, 2015 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C Pass INDUSTRY CANADA RSS-210 Issue 8, Annex 1 Pass INDUSTRY CANADA RSS-GEN Issue 4 Pass UL Verification Services Inc tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL Verification Services Inc will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Approved & Released For UL Verification Services Inc By: Tested By: PENG ZHANG R. ALEGRE PROJECT LEAD LAB ENGINEER UL Verification Services Inc. UL Verification Services Inc. REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 5 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENI…

Text truncated - open the document above for the full version.

Test Setup Photos

REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 29 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. 9. SETUP PHOTOS ANTENNA PORT ANTENNA PORT REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 30 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 31 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 32 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 33 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION BELOW 30 MHz RADIATED EMISSIONS BELOW 30MHz (FRONT) REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 34 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSIONS BELOW 30MHz (BACK) REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 35 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSION ABOVE 30 MHz RADIATED EMISSIONS ABOVE 30 MHz (FRONT) REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 36 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. RADIATED EMISSIONS ABOVE 30 MHz (BACK) RADIATED EMISSIONS ABOVE 1000 MHz (BACK) REPORT NO: 15U21470 DATE: AUGUST 17, 2015 FCC ID: XQC-WST242 IC: 9863B-WST242 Page 37 of 37 UL VERIFICATION SERVICES INC FORM NO: CCSUP4701I 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc.. END OF REPORT RADIATED EMISSIONS ABOVE 1000 MHz (FRONT)

Contact Information

Applicant

Jay Stone
[email protected]760-431-8804Fax: 760-431-8975

Test Firm

UL Verification Services Inc. (formerly UL CCS)Jay Kogoma
[email protected]510-319-4135Fax: 000-000-0000

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231345 MHz - 345 MHz-
Confidentiality
Long Term

Other Applications from Ecolink Intelligent Technology, Inc.

Wearable Action Button - FCC ID XQC-WST132 - Ecolink Intelligent Technology, Inc.
XQC-WST132

Wearable Action Button

Feb 07, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Flood and Freeze Sensor - FCC ID XQC-WST621 - Ecolink Intelligent Technology, Inc.
XQC-WST621

Flood and Freeze Sensor

May 01, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Motion Detector - FCC ID XQC-WST740 - Ecolink Intelligent Technology, Inc.
XQC-WST740

Motion Detector

Jul 04, 2022

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Motion Detector - FCC ID XQC-WST742 - Ecolink Intelligent Technology, Inc.
XQC-WST742

Motion Detector

Feb 17, 2021

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Audio Detector - FCC ID XQC-CS602 - Ecolink Intelligent Technology, Inc.
XQC-CS602

Audio Detector

Feb 17, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter